Application Details

Equipment Class
8CC - Part 18 Consumer Device
Date of Grant
Jan 02, 2020
Application Purpose
Original Equipment
Date of Application
Jan 02, 2020
Equipment Note
AirMount MAG
Frequency Range
0.11000000 - 0.20500000
Company
Piware Technology
Country
China

Documents & Files

Select a file to view

Users Manual

↗

Cover Letter(s)

↗
↗
↗

External Photos

↗

ID Label/Location Info

↗

Internal Photos

↗

RF Exposure Info

↗

Test Report

↗

Test Setup Photos

↗

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

Users Manual

FCC Statement This device complies with part 15 and part 18 of the FCC Rules. Operation is Subject To the following two conditions: (1) This device may not cause harmful interference, and (2) this devicemust accept any interference received, including interference that may cause undesired operation. Changes or modifications not explicitly approved by the partyresponsible for compliance could void the user's authority tooperate this equipment. Note: this equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 and part 18 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and canradiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference toradio or television reception, which can be determined by turning the equipment off and on, the user is encouraged totry to correct the interference by one or more of the following measures: • Reorient or relocate the receiving antenna. • Increase the separation between the equipment and receiver. • Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. • Consult the dealer or an experienced radio/TV technician for help. The equipment complies with FCC radiation exposure limits set forth for an uncontrolled environment. During the operation of device a distance of 15 cm surrounding the device and 20 cm above the top surface of the device must be respected. This device complies with Part 18 of the FCC Rules. This equipment generates uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures: ● Increase the separation between the equipment and any other radio device. ● Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. FOD N S 1 x 2 in 1 Magnetic Mount1 x Suction Cup Car Mount

Cover Letter(s)

CONFIDENTIALITY REQUEST for Certification Service in USA Federal Communication Commission Equipment Authorization Division, Application Processing Branch 7435 Oakland Mills Road Columbia, MD 21046 <2019-12-28> TO WHOM IT MAY CONCERN Pursuant to Paragraphs §0.457 and 0.459 of the Commission’s Rules (47 C.F.R.) and Section §552(b)(4) of the Freedom of Information Act, we requests confidentiality for the following products: FCC ID Model name 2AVGW-M3 M3 For the product stated above, we request that the following information be held confidential; Exhibits Long-Term Confidentiality Short-Term Confidentiality Short-Term Confidentiality Days External Photos Internal Photos Block Diagram Schematics Test Setup Photos User’s Manual Parts List Tune Up Operational Descriptions The long-term confidentiality exhibits contain our trade secrets and proprietary information that could be of benefit to our competitors. The short-term confidentiality on the basis of ensuring that business sensitive information remains confidential until the actual marketing of our new device. If you have any questions, please feel free to contact me at the address shown below. Sincerely, (Signed) Name/Title: Gang Chen / Manager Company: Piware Technology Address: 111 Boyun Rd., 1st Floor, Pu Dong, Shanghai, China Phone: 13817523803 Fax: 0574-83080911 E-Mail: [email protected]

Cover Letter(s)

Piware Technology 111 Boyun Rd., 1st Floor, Pu Dong, Shanghai, China Labeling Declaration Letter FCC ID: 2AVGW-M3 Model Number: M3 DATE: 2019-12-28 Following the KDB 784748 D01 General labeling and Notification, the information related to Labeling implementation for the AirMount MAG, FCC ID: 2AVGW-M3 Information On Product On Product Packaging In Online User Guide In Printed User Guide FCC ID Number Yes Yes No No 15.19 Statement “This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation” No No No Yes Changes or modifications not expressly approved by the party responsible for compliance could void the user's authority to operate the equipment No No No Yes Product Packaging Label is shown below: FCC ID: 2AVGW-M3 This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, The product is packaged individually. Piware Technology 111 Boyun Rd., 1st Floor, Pu Dong, Shanghai, China Should you have any questions or comments regarding this matter, please have my best attention. Sincerely, Best Regards! (Signed) Name / Title: Gang Chen / Manager Company: Piware Technology Address: 111 Boyun Rd., 1st Floor, Pu Dong, Shanghai, China Phone: 13817523803 Fax: 0574-83080911 E-Mail: [email protected]

Cover Letter(s)

Piware Technology 111 Boyun Rd., 1st Floor, Pu Dong, Shanghai, China FCC ID: 2AVGW-M3 Model Number: M3 DATE: 2019-12-28 To: Federal Communication Commission Authorization and Evaluation Division 7435 Oakland Mills Road Columbia, MD 21048 To Whom It May Concern, We, Piware Technology hereby declare that our product (AirMount MAG) Model Number: M3 meet item 5.2 of KDB 680106v02 as follow; Requirements of KDB 680106 D01 Yes / No Description Power transfer frequency is less than 1 MHz Yes The device operate in the frequency range 110.0 KHz - 205.0 KHz Output power from each primary coil is less than 15 watts Yes The maximum output power of the primary coil is 10W. The transfer system includes only single primary and secondary coils. This includes charging systems that may have multiple primary coils and clients that are able to detect and allow coupling only between individual pairs of coils. Yes The transfer system includes only single coil that is able to detect receiver device. Client device is placed directly in contact with the transmitter. Yes Client device is placed directly in contact with the transmitter. Mobile exposure conditions only (portable exposure conditions are not covered by this exclusion). Yes Mobile exposure conditions only The aggregate H-field strengths at 15 cm surrounding the device and 20 cm above the top surface from all simultaneous transmitting coils are demonstrated to be less than 50% of the MPE limit. Yes The aggregate H-field strengths at 15 cm surrounding the device and 20 cm above the top surface from all simultaneous transmitting coils are less than 50% the MPE limit. Per KDB 680106 section 5 c); in all other cases, unless excluded by 5. b) above, an RF exposure evaluation report must be reviewed and accepted through a KDB inquiry to enable authorization of the equipment. When evaluation is required to show compliance; for example, using field strength, power density, SAR measurements or computational modeling etc., the specific authorization requirements will be determined based on the results of the RF exposure evaluation. Please contact me if you have any question. Piware Technology 111 Boyun Rd., 1st Floor, Pu Dong, Shanghai, China Best Regards! (Signed) Name / Title: Gang Chen / Manager Company: Piware Technology Address: 111 Boyun Rd., 1st Floor, Pu Dong, Shanghai, China Phone: 13817523803 Fax: 0574-83080911 E-Mail: [email protected]

External Photos

SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD. FCC ID: 2AVGW-M3 Report No.: LCS191209022BE This report shall not be reproduced except in full, without the written approval of Shenzhen LCS Compliance Testing Laboratory Ltd. Page 1 of 3 External Photographs of the EUT Fig. 1 Fig. 2 SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD. FCC ID: 2AVGW-M3 Report No.: LCS191209022BE This report shall not be reproduced except in full, without the written approval of Shenzhen LCS Compliance Testing Laboratory Ltd. Page 2 of 3 Fig. 3 Fig. 4 SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD. FCC ID: 2AVGW-M3 Report No.: LCS191209022BE This report shall not be reproduced except in full, without the written approval of Shenzhen LCS Compliance Testing Laboratory Ltd. Page 3 of 3 Fig. 5 Fig. 6

ID Label/Location Info

SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD. FCC ID: 2AVGW-M3 Report No.: LCS191209022BE This report shall not be reproduced except in full, without the written approval of Shenzhen LCS Compliance Testing Laboratory Ltd. Page 1 of 1 Label and Location Size: L: 4.0cm*W: 3.0cm AirMount MAG Model No.: M3 FCC ID : 2 AV G W-M33 Made In China Label Location

Internal Photos

SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD. FCC ID: 2AVGW-M3 Report No.: LCS191209022BE This report shall not be reproduced except in full, without the written approval of Shenzhen LCS Compliance Testing Laboratory Ltd. Page 1 of 2 Internal Photographs of the EUT Fig. 1 Fig. 2 Coil SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD. FCC ID: 2AVGW-M3 Report No.: LCS191209022BE This report shall not be reproduced except in full, without the written approval of Shenzhen LCS Compliance Testing Laboratory Ltd. Page 2 of 2 Fig. 3 Fig. 4

RF Exposure Info

SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD. FCC ID: 2 AVG W-M3 Report No.: LCS191209022BE ___________________________________________________________________________ This report shall not be reproduced except in full, without the written approval of Shenzhen LCS Compliance Testing Laboratory Ltd. Page 1 of 9 RF Exposure Evaluation Report 1. Product Information FCC ID: 2AVGW-M3 Product Name AirMount MAG Model Number M3 Power Supply Input: DC 5V/2A OR DC 9V/1.6A Output: DC 9V, 1.12A, 10W (Max.) Modulation Type Continuous Wave Frequency Range 110.0 - 205.0 KHz Operation Frequency 160.0 KHz Rated Power of WPT 10 W Antenna Type Coil Antenna Hardware version / Software version / Accessories iPhone 8 Plus Exposure category General population/uncontrolled environment EUT Type Production Unit Device Type Mobile Device 2. Evaluation Method Per KDB 680106 D01 Section 3. RF Exposure Requirements; 1) Consumer wireless power transfer devices approved under Part 18 in some cases have to demonstrate compliance with RF exposure requirements. The potential for exposure must be assessed according to the operating configurations of the wireless system and the exposure conditions of users and bystanders. RF exposure must be evaluated with the client device(s) being charged by the primary at maximum output power. The RF exposure requirements must be determined in conjunction with the device operating characteristics, according to the mobile and portable exposure requirements in Section 2.1091 and Section 2.1093 of the rules. SAR and MPE limits do not cover the frequency range for wireless power transfer applications which operate below 100 kHz and 300 kHz respectively; therefore, RF exposure compliance needs to be determined with respect to 1.1307 (c) and (d) of the FCC rules. 2) Based on the design and implementation of the power transfer application, it must be clearly identified if mobile or portable RF exposure conditions apply. Devices that are installed to provide separation of at least 20 cm from users and bystanders may qualify for mobile exposure conditions. For some conditions where users and bystanders may be exposed at closer than 20 cm, section 2.1091(d) (4) of the rules may apply. 3) For devices designed for typical desktop applications, such a wireless charging pads, RF exposure evaluation should be conducted assuming a user separation distance of 15 cm. E and H field strength measurements or numerical modeling may be used to demonstrate compliance. Measurements should be made from all sides and the top of the primary/client pair, with the 15 cm measured from the center of the probe(s) to the edge of the device. Emissions between 100 kHz to 300 kHz should be assessed versus the limits at 300 kHz in Table 1 of Section 1.1310: 614 V/m and 1.63 A/m. A KDB inquiry is required to determine the applicable exposure limits below 100 kHz 4) Portable exposure conditions from 100 kHz to 6 GHz are determined with respect to SAR requirements. SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD. FCC ID: 2 AVG W-M3 Report No.: LCS191209022BE ___________________________________________________________________________ This report shall not be reproduced except in full, without the written approval of Shenzhen LCS Compliance Testing Laboratory Ltd. Page 2 of 9 Existing SAR systems and test procedures are generally intended for measurements above 100 MHz. While numerical modeling can be an alternative, the constraints of substantial computational resources at low frequencies could introduce further limitations. Under these circumstances, including operations below 100 kHz, the Commission may consider a combination of analytical analysis, field strength, radiated and conducted power measurements, in conjunction with some limited numerical modeling to assess compliance. 5) Depending on the operating frequency, existing SAR and MPE measurement procedures may be adapted to evaluate wireless power transfer devices for compliance with respect to mobile or portable exposure conditions. If the grantee or its test lab have any questions regarding RF exposure evaluation they should contact the FCC Laboratory with sufficient system operating configuration details to determine if RF exposure evaluation is necessary and, if required, how to apply specific test procedures. Below 100 MHz, when SAR testing is required and the device is operating at close proximity to persons, information on device design, implementation, operating configurations, exposure conditions of users and bystanders are needed to determine the evaluation and testing requirements. In addition, the influence of nearby objects may also need consideration according to the wireless power transfer system implementation; for example, the effects of placing the device, its coils or radiating elements on or near metallic surfaces. 6) According to April 2018 TCB Workshop, No need to report E-field measurements. Only H-field required. 3. Evaluation Limit 3.1 Refer evaluation method ANSI C95.1–1999: IEEE Standard for Safety Levels with Respect to Human Exposure to Radio Frequency Electromagnetic Fields, 3 kHz to 300 GHz. FCC KDB publication 680106 D01 RF Exposure Wireless Charging Apps v03: RF Exposure Considerations for Low Power Consumer Wireless Power Transfer Applications FCC CFR 47 part1 1.1310: Radiofrequency radiation exposure limits. FCC CFR 47 part2 2.1091: Radiofrequency radiation exposure evaluation: mobile devices FCC CFR 47 part 18.107: Indusial, Scientific, and Medical Equipment 3.2 Limit Limits for Maximum Permissible Exposure (MPE)/Controlled Exposure Frequency Range(MHz) Electric Field Strength(V/m) Magnetic Field Strength(A/m) Power Density (mW/cm²) Averaging Time (minute) Limits for Occupational/Controlled Exposure 0.3-3.0 614 1.63 *100 6 3.0-30 1842/f 4.89/f *900/f 2 6 30-300 61.4 0.163 1.0 6 300-1,500 / / f/300 6 1,500-100,000 / / 5 6 SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD. FCC ID: 2 AVG W-M3 Report No.: LCS191209022BE ____________________…

Text truncated - open the document above for the full version.

Test Report

SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD. FCC ID: 2AVGW-M3 Report No.: LCS191209022BE This report shall not be reproduced except in full, without the written approval of Shenzhen LCS Compliance Testing Laboratory Ltd. Page 1 of 25 FCC TEST REPORT FOR Piware Technology AirMount MAG Test Model: M3 Prepared for : Piware Technology Address : 111 Boyun Rd., 1st Floor, Pu Dong, Shanghai, China Prepared by : Shenzhen LCS Compliance Testing Laboratory Ltd. Address : 1/F., Xingyuan Industrial Park, Tongda Road, Bao’an Avenue, Bao’an District, Shenzhen, Guangdong, China Tel : (+86)755-82591330 Fax : (+86)755-82591332 Web : www.LCS-cert.com Mail : [email protected] Date of receipt of test sample : December 09, 2019 Number of tested samples : 1 Serial number : Prototype Date of Test : December 09, 2019 ~ December 26, 2019 Date of Report : December 26, 2019 SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD. FCC ID: 2AVGW-M3 Report No.: LCS191209022BE This report shall not be reproduced except in full, without the written approval of Shenzhen LCS Compliance Testing Laboratory Ltd. Page 2 of 25 FCC TEST REPORT FCC CFR 47 PART 18: 2017 Report Reference No. ................ : LCS191209022BE Date of Issue .................................. : December 26, 2019 Testing Laboratory Name ............ : Shenzhen LCS Compliance Testing Laboratory Ltd. Address .......................................... : 1/F., Xingyuan Industrial Park, Tongda Road, Bao'an Avenue, Bao'an District, Shenzhen, Guangdong, China Testing Location/ Procedure .......... : Full application of Harmonised standards ■ Partial application of Harmonised standards □ Other standard testing method □ Applicant’s Name ......................... : Piware Technology Address .......................................... : 111 Boyun Rd., 1st Floor, Pu Dong, Shanghai, China Test Specification Standard ......................................... : FCC CFR 47 PART 18: 2017 Test Report Form No. .................... : LCSEMC-1.0 TRF Originator................................ : Shenzhen LCS Compliance Testing Laboratory Ltd. Master TRF .................................... : Dated 2011-03 Shenzhen LCS Compliance Testing Laboratory Ltd. All rights reserved. This publication may be reproduced in whole or in part for non-commercial purposes as long as the Shenzhen LCS Compliance Testing Laboratory Ltd. is acknowledged as copyright owner and source of the material. Shenzhen LCS Compliance Testing Laboratory Ltd. takes no responsibility for and will not assume liability for damages resulting from the reader's interpretation of the reproduced material due to its placement and context. Test Item Description. .................. : AirMount MAG Trade Mark ..................................... : N/A Test Model ...................................... : M3 Ratings ........................................... : Input: DC 5V/2A OR DC 9V/1.6A Output: DC 9V, 1.12A, 10W (Max.) Result ........................................... : Positive Compiled by: Supervised by: Approved by: Marry Chen /Administrators Calvin Weng/ Technique principal Gavin Liang/ Manager SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD. FCC ID: 2AVGW-M3 Report No.: LCS191209022BE This report shall not be reproduced except in full, without the written approval of Shenzhen LCS Compliance Testing Laboratory Ltd. Page 3 of 25 FCC -- TEST REPORT Test Result Positive The test report merely corresponds to the test sample. It is not permitted to copy extracts of these test result without the written permission of the test laboratory. Test Report No. : LCS191209022BE December 26, 2019 Date of issue Test Model........................ : M3 EUT.................................... : AirMount MAG Applicant........................... : Piware Technology Address.............................. : 111 Boyun Rd., 1st Floor, Pu Dong, Shanghai, China Telephone.......................... : / Fax..................................... : / Manufacturer..................... : Piware Technology Address.............................. : 111 Boyun Rd., 1st Floor, Pu Dong, Shanghai, China Telephone.......................... : / Fax..................................... : / Factory.............................. : Shenzhen Wintop Electronics Co. Ltd. Address.............................. : HuaGuan Park, No.46 Xinhe Road, Baolai Industrial District, Shang mugu, Pinghu Town Longgang District, Shenzhen City, 518111, China. Telephone.......................... : / Fax..................................... : / SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD. FCC ID: 2AVGW-M3 Report No.: LCS191209022BE This report shall not be reproduced except in full, without the written approval of Shenzhen LCS Compliance Testing Laboratory Ltd. Page 4 of 25 Revision History Revision Issue Date Revisions Revised By 000 December 26, 2019 Initial Issue Gavin Liang SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD. FCC ID: 2AVGW-M3 Report No.: LCS191209022BE This report shall not be reproduced except in full, without the written approval of Shenzhen LCS Compliance Testing Laboratory Ltd. Page 5 of 25 TABLE OF CONTENTS 1. GENERAL INFORMATION ................................................................................................................. 6 1.1 Description of Device (EUT) ....................................................................................................................... 6 1.2 Support equipment List ................................................................................................................................ 6 1.3 External I/O Cable ........................................................................................................................................ 6 1.4 Description of Test Facility .......................................................................................................................... 6 1.5 Statement of the Measurement Uncertainty ...........................................................…

Text truncated - open the document above for the full version.

Test Setup Photos

SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD. FCC ID: 2AVGW-M3 Report No.: LCS191209022BE _______________________________________________________________________________________________ This report shall not be reproduced except in full, without the written approval of Shenzhen LCS Compliance Testing Laboratory Ltd. Page 1 of 1 Photographs of Test Setup Test Setup Photo(s) of Radiated Emissions Measurement Fig. 1 Fig. 2

Contact Information

Applicant

Gang Chen(Manager)
[email protected]86-13817523803Fax: 86-0574-83080911

Test Firm

Shenzhen LCS Compliance Testing Laboratory Ltd.Gavin Liang
[email protected]0755-82591330Fax: 0755-82591132

Technical Specifications

#Rule PartsFrequency RangePower Output
1180.11 MHz - 0.205 MHz-
Confidentiality
Long Term