Application Details

Equipment Class
DXX - Part 15 Low Power Communication Device Transmitter
Date of Grant
Dec 15, 2020
Application Purpose
Original Equipment
Date of Application
Dec 15, 2020
Equipment Note
Electric vehicle charging station
Frequency Range
13.56000000 - 13.56000000
Company
Elinta Charge, UAB
Country
Lithuania

Documents & Files

Select a file to view

Users Manual

↗

Cover Letter(s)

↗
↗

External Photos

↗

ID Label/Location Info

↗
↗

Internal Photos

↗

Test Report

↗

Test Setup Photos

↗

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

Users Manual

To start charging: 1) Connect charging cable to electric vehicle; 2) Connect charging cable to charging station; 3) Put the RFID identification card to the right place. The charging will start after few seconds. LED strips indicates status of charging station: • Blue – ready / charging finished; • Red – station is busy / charging electric vehicle. Charging cable is locked during the vehicle charging. When the vehicle is fully charged the charging stops automatically, or it can be stopped by using RFID identification card. The place to use RFID card. A/B indication is lightning in red during the vehicle charging. A/B indication is lightning in blue when the charging is finished. “READY” indication lights on when the charging is finished. “CHARGING” indication is lightning during the vehicle charging. LED screen CityCharge User manual Elinta Charge, UAB Partizanu g. 63M, Kaunas 50306 Lithuania Tel.: +370 615 71604 [email protected] www.elintacharge.com CityCharge Legal information User changes or modifications not expressly approved by the party responsible for compliance could void the user's authority to operate the equipment.

Cover Letter(s)

{nr ry ELTHTA tdqrnni:i--- ELINTA CHARGE, UAB Code: 304841 472 vAT: LT100011735515. Partizanq g. 63M, Kaunas, LT-50300 Tel.: +370 653 66633, +370 655 OO4jB, faks.: (B 3T) 452180, E-Mail : rnfoGelintacharge. com Date: zozo os 08 UL LLC 12 Laboratory Dr RTP, NC 277O9,USA To whom it may concern: I, the undersigned, hereby authorize UL LLC to act on our behalf in all manners relating to application for equipment authorization, including signing of all documents relating to these matters. Any and all acts carried out by UL LLC on our behalf shall have the same effect as acts of our own. I, the undersigned, hereby certify that we are not subject to a denial of federal benefits, that includes FCC benefits, pursuant to Section 5301 of the Anti-Drug Abuse Act of 1988,21 U.S.C. 853(a). In authorizing UL LLC as our agent, we still recognize that we are responsible to: a) comply with the relevant provisions of the certification program; b) make all necessary arrangements for the conduct of the evaluation, including provision for examining documentation and access to all areas, records (including internal audit reports) and personnel for the purposes of evaluation (e.g. testing, inspection, assessment, surveil lance, reassessment) and resolution of complaints; c) make claims regarding certification only in respect of the scope for which certification has been granted; d) do not use our product certification in such a manner as to bring UL LLC into disrepute and not make any statement regarding our product certification which UL LLC may consider misleading or unauthorized; upon suspension or cancellation of certification, discontinue use of all advertising matter that contains any reference thereto and return any certification documents as required by UL LLC; use certification only to indicate the products are certified as being in conformity with specifi ed standards; endeavor to ensure that no certificate or report nor any part thereof is used in a misleading manner; ensure that any reference to our product certification in communication media such as documents, brochures or advertising, complies with the requirements of UL LLC; keep a record of all complaints made known to the us relating to the product's compliance with requirements of the relevant standard and to make these records available to UL LLC when requested; take appropriate action with respect to such complaints and any deficiencies found in pioducts or services that affect compliance with the requirements for certification: document the actions taken. This authorization is valid until further written notice from the applicant. Sincerelv Yours. CTO Dainius Janulevidius Elinta Charge REMARK: 1. 2. 3. ion letter will be sent along with your application when filing with UL LLC. the format and type it on company letterhead and send original to us. 'signature must be in agreement with grantee code contact in FCC database. e) 0 o) o/ h) i) i) k)

Cover Letter(s)

F W* EUNTA Wl cnnnee ELINTA CHARGE. UAB Code:304847412 VAT: LT100011735515. Partizarr.q g.63M, Kaunas, LT-50300 Tel.: +370 653 66633,+370 655 0047 E-Mail : info@el intacharge.com Federal Communications Comm ission 7435 Oakland Mills Road Columbia MD 21046 Subject: Request for Confidentiality FCC ID: zAVIZ-CCV222COM To Whom It May Concern: Pursuant to the provisions of Sections 0.457 and 0.459 of the Commission's rules (47 CFR $$ 0.457,0.459), we are requesting the Commission to withhold the following attachments as confidential document from public disclosure indefinitely. Schematic Diagram Block Diagram Theory of Operation Antenna Specification Above mentioned document contains detailed system and equipment description are considered as proprietary information in operation of the equipment. The public disclosure of above documents might be harmful to our company and would give competitor an unfair advantage in the market. In additional to above mentioned documents, pursuant to Public Notice DA 04-1705 of the Commission's policy, in order to comply with the marketing regulations in 47 CFR $2.803 and the importation rules in 47 CFR 52.1204, while ensuring that business sensitive information remains confidential until the actual marketing of newly authorized devices. We are requesting the commission to grant short-term confidentiality request on the following attachments until: 1 80 days past the grant date. External Photos Internal Photos Test Setup Photos User Manual It is our understanding that all measurement test reports, FCC ID label format and correspondent during certification review process cannot be granted as confidential documents and those information will be availabie for public review once the grant of equipment authorization is issued.

ID Label/Location Info

1 A 2 3 4 5 678 12 3 4 5 678 B C D E F A B C D E F Dept.Technical referenceCreated byApproved by Document typeDocument status TitleDWG No. Rev.Date of issueSheet 2020-04-17 1/1 CCV22020.04.17.CC016.S1 Rokas Endziulis 46 173

Test Report

NVLAP Lab code: 200246-0 CERTIFICATION TEST REPORT Report Number: R13057024-E1 Applicant : Elinta Charge, UAB Terminalo g. 3, Biruliškių k. LT-54469 Kauno r. Model : CC-V2-22-COM FCC ID : 2AVJZ-CCV222COM IC : 25774-CCV222COM EUT Description : Electric vehicle charging station Test Standard(s) : FCC 47 CFR PART 15 SUBPART C ISED CANADA RSS-210 ISSUE 10 Date Of Issue: 2020-03-31 Prepared by: UL LLC 12 Laboratory Dr. Research Triangle Park, NC 27709 U.S.A. TEL: (919) 549-1400 REPORT NO: R13057024-E1 DATE: 2020-03-31 FCC ID: 2AVJZ-CCV222COM IC: 25774-CCV222COM Page 2 of 38 UL LLC FORM NO: CCSUP4701I 12 Laboratory Dr., RTP, NC 27709; USA TEL:(919) 549-1400 This report shall not be reproduced except in full, without the written approval of UL LLC REVISION HISTORY Rev. Issue Date Revisions Revised By 1 2020-03-31 Initial Revision Brian T. Kiewra REPORT NO: R13057024-E1 DATE: 2020-03-31 FCC ID: 2AVJZ-CCV222COM IC: 25774-CCV222COM Page 3 of 38 UL LLC FORM NO: CCSUP4701I 12 Laboratory Dr., RTP, NC 27709; USA TEL:(919) 549-1400 This report shall not be reproduced except in full, without the written approval of UL LLC TABLE OF CONTENTS REVISION HISTORY ..................................................................................................................2 TABLE OF CONTENTS .............................................................................................................3 1. ATTESTATION OF TEST RESULTS ..................................................................................4 2. TEST METHODOLOGY ......................................................................................................5 3. FACILITIES AND ACCREDITATION ..................................................................................5 4. CALIBRATION AND UNCERTAINTY .................................................................................6 MEASURING INSTRUMENT CALIBRATION ...............................................................6 SAMPLE CALCULATION .............................................................................................6 MEASUREMENT UNCERTAINTY ................................................................................6 5. EQUIPMENT UNDER TEST ................................................................................................7 DESCRIPTION OF EUT ...............................................................................................7 MAXIMUM ELECTRIC FIELD STRENGTH ..................................................................7 SOFTWARE AND FIRMWARE .....................................................................................7 WORST-CASE CONFIGURATION AND MODE ...........................................................7 DESCRIPTION OF TEST SETUP .................................................................................8 6. TEST AND MEASUREMENT EQUIPMENT ........................................................................9 7. OCCUPIED BANDWIDTH .................................................................................................11 8. RADIATED EMISSION TEST RESULTS...........................................................................13 LIMITS AND PROCEDURE ........................................................................................13 FUNDAMENTAL AND SPURIOUS EMISSIONS (0.15 - 30 MHz) ...............................15 WITHOUT TAG ....................................................................................................15 WITH TAG ...........................................................................................................19 TX SPURIOUS EMISSION 30 TO 1000 MHz .............................................................23 WITHOUT TAG ....................................................................................................23 WITH TAG ...........................................................................................................25 NO RADIO ON .....................................................................................................27 9. FREQUENCY STABILITY .................................................................................................29 WITHOUT TAG ...........................................................................................................29 WITH TAG ..................................................................................................................30 10. AC MAINS LINE CONDUCTED EMISSIONS ....................................................................31 WITHOUT TAG .......................................................................................................32 NORMAL OPERATION ....................................................................................32 WITH TAG ...............................................................................................................34 NORMAL OPERATION ....................................................................................34 ANTENNA PORT TERMINATED WITH DUMMY LOAD..........................................36 11. SETUP PHOTOS ...............................................................................................................38 END OF TEST REPORT ..........................................................................................................38 REPORT NO: R13057024-E1 DATE: 2020-03-31 FCC ID: 2AVJZ-CCV222COM IC: 25774-CCV222COM Page 4 of 38 UL LLC FORM NO: CCSUP4701I 12 Laboratory Dr., RTP, NC 27709; USA TEL:(919) 549-1400 This report shall not be reproduced except in full, without the written approval of UL LLC 1. ATTESTATION OF TEST RESULTS COMPANY NAME: Elinta Charge, UAB Terminalo g. 3, Biruliškių k. LT-54469 Kauno r. EUT DESCRIPTION: Electric vehicle charging station MODEL: CC-V2-22-COM SERIAL NUMBER: 19v2-17-08 DATE TESTED: 2019-12-12 to 2020-03-30 APPLICABLE STANDARDS STANDARD TEST RESULTS FCC PART 15 SUBPART C Complies ISED RSS-210 Issue 10, Annex B.6 Complies ISED RSS-GEN Issue 5 Complie…

Text truncated - open the document above for the full version.

Test Setup Photos

NVLAP Lab code: 200246-0 SETUP PHOTOS EXHIBIT Report Number: R13057024-EP1 Applicant : Elinta Charge, UAB Terminalo g. 3, Biruliškių k. LT-54469 Kauno r. Model : CC-V2-22-COM FCC ID : 2AVJZ-CCV222COM IC : 25774-CCV222COM EUT Description : Electric vehicle charging station Test Standard(s) : FCC 47 CFR PART 15 SUBPART C ISED CANADA RSS-210 ISSUE 10 Date Of Issue: 2020-03-31 Prepared by: UL LLC 12 Laboratory Dr. Research Triangle Park, NC 27709 U.S.A. TEL: (919) 549-1400 REPORT NO: R13057024-EP1 DATE: 2020-03-31 FCC ID: 2AVJZ-CCV222COM IC: 25774-CCV222COM Page 2 of 10 UL LLC FORM NO: CCSUP4701I 12 Laboratory Dr., RTP, NC 27709; USA TEL:(919) 549-1400 This report shall not be reproduced except in full, without the written approval of UL LLC REVISION HISTORY Rev. Issue Date Revisions Revised By 1 2020-03-31 Initial Revision Brian T. Kiewra REPORT NO: R13057024-EP1 DATE: 2020-03-31 FCC ID: 2AVJZ-CCV222COM IC: 25774-CCV222COM Page 3 of 10 UL LLC FORM NO: CCSUP4701I 12 Laboratory Dr., RTP, NC 27709; USA TEL:(919) 549-1400 This report shall not be reproduced except in full, without the written approval of UL LLC TABLE OF CONTENTS REVISION HISTORY ..................................................................................................................2 TABLE OF CONTENTS .............................................................................................................3 1. SETUP DIAGRAM FOR TESTS ..........................................................................................4 2. SETUP PHOTOS .................................................................................................................5 END OF TEST REPORT ..........................................................................................................10 REPORT NO: R13057024-EP1 DATE: 2020-03-31 FCC ID: 2AVJZ-CCV222COM IC: 25774-CCV222COM Page 4 of 10 UL LLC FORM NO: CCSUP4701I 12 Laboratory Dr., RTP, NC 27709; USA TEL:(919) 549-1400 This report shall not be reproduced except in full, without the written approval of UL LLC 1. SETUP DIAGRAM FOR TESTS REPORT NO: R13057024-EP1 DATE: 2020-03-31 FCC ID: 2AVJZ-CCV222COM IC: 25774-CCV222COM Page 5 of 10 UL LLC FORM NO: CCSUP4701I 12 Laboratory Dr., RTP, NC 27709; USA TEL:(919) 549-1400 This report shall not be reproduced except in full, without the written approval of UL LLC 2. SETUP PHOTOS RADIATED EMISSION BELOW 30 MHz RADIATED EMISSIONS BELOW 30MHz (WITHOUT TAG) REPORT NO: R13057024-EP1 DATE: 2020-03-31 FCC ID: 2AVJZ-CCV222COM IC: 25774-CCV222COM Page 6 of 10 UL LLC FORM NO: CCSUP4701I 12 Laboratory Dr., RTP, NC 27709; USA TEL:(919) 549-1400 This report shall not be reproduced except in full, without the written approval of UL LLC RADIATED EMISSIONS BELOW 30MHz (WITH TAG) REPORT NO: R13057024-EP1 DATE: 2020-03-31 FCC ID: 2AVJZ-CCV222COM IC: 25774-CCV222COM Page 7 of 10 UL LLC FORM NO: CCSUP4701I 12 Laboratory Dr., RTP, NC 27709; USA TEL:(919) 549-1400 This report shall not be reproduced except in full, without the written approval of UL LLC AC MAINS LINE CONDUCTED EMISSION LINE CONDUCTED EMISSION (WITHOUT TAG) REPORT NO: R13057024-EP1 DATE: 2020-03-31 FCC ID: 2AVJZ-CCV222COM IC: 25774-CCV222COM Page 8 of 10 UL LLC FORM NO: CCSUP4701I 12 Laboratory Dr., RTP, NC 27709; USA TEL:(919) 549-1400 This report shall not be reproduced except in full, without the written approval of UL LLC LINE CONDUCTED EMISSION (WITH TAG) REPORT NO: R13057024-EP1 DATE: 2020-03-31 FCC ID: 2AVJZ-CCV222COM IC: 25774-CCV222COM Page 9 of 10 UL LLC FORM NO: CCSUP4701I 12 Laboratory Dr., RTP, NC 27709; USA TEL:(919) 549-1400 This report shall not be reproduced except in full, without the written approval of UL LLC LINE CONDUCTED EMISSION (WITH DUMMY LOAD) REPORT NO: R13057024-EP1 DATE: 2020-03-31 FCC ID: 2AVJZ-CCV222COM IC: 25774-CCV222COM Page 10 of 10 UL LLC FORM NO: CCSUP4701I 12 Laboratory Dr., RTP, NC 27709; USA TEL:(919) 549-1400 This report shall not be reproduced except in full, without the written approval of UL LLC FREQUENCY TOLERANCE OVER EXTREME CONDITIONS END OF TEST REPORT FREQUENCY TOLERANCE OVER EXTREME CONDITIONS

Contact Information

Applicant

Dainius Janulevicius(CTO)
[email protected]+37065366633Fax: +37037452780

Test Firm

UL LLCRick Titus
[email protected]847-272-8800Fax: 847-313-3281

Technical Specifications

#Rule PartsFrequency RangePower Output
115C13.56 MHz - 13.56 MHz-
Confidentiality
Long Term