  3. 2AVRVCTP100LG01

2AVRVCTP100LG01PROFESSIONAL WIRELESS THERMAL PRINTER

DP AUDIO VIDEO LLC
PROFESSIONAL WIRELESS THERMAL PRINTER - FCC ID 2AVRVCTP100LG01 - DP AUDIO VIDEO LLC
Click to zoom

Application Details

Equipment Class
DTS - Digital Transmission System
Date of Grant
Sep 16, 2025
Application Purpose
Original Equipment
Equipment Note
PROFESSIONAL WIRELESS THERMAL PRINTER
Frequency Range
2402.00000000 - 2480.00000000
Company
DP AUDIO VIDEO LLC
Country
United States

Documents & Files

Select a file to view

Users Manual

↗

Attestation Statements

↗
↗

Cover Letter(s)

↗
↗

External Photos

↗

ID Label/Location Info

↗

Internal Photos

↗

RF Exposure Info

↗

Test Report

↗
↗
↗

Test Setup Photos

↗

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

Attestation Statements

DP AUDIO VIDEO LLC Covered Equipment Certification Attestation Letter 8/25/2025 Federal Communications Commission Authorization and Evaluation Division 7435 Oakland Mills Road Columbia, MD 21046 USA ATTN.: Reviewing Engineer FCC ID: 2AVRVCTP100LG01 DP AUDIO VIDEO LLC certifies that the equipment for which authorization is sought is not “covered” equipment prohibited from receiving an equipment authorization pursuant to section 2.903 of the FCC rules. Note: If the equipment for which the applicant seeks authorization is produced by any of the entities identified on the current Covered List, the applicant should include an explanation on why the equipment is not “covered” equipment. DP AUDIO VIDEO LLC certifies that, as of the date of the filing of the application, the applicant is not identified on the Covered List (as a specifically named entity or any of its subsidiaries or affiliates)as an entity producing “covered” equipment. DP AUDIO VIDEO LLC certifies that the equipment for which authorization is sought does not include cybersecurity or anti-virus software produced or provided by Kaspersky Lab, Inc. or any of its successors and assignees, including equipment with integrated Kaspersky Lab, Inc. (or any of its successors and assignees) cybersecurity or anti-virus software pursuant to DA-24-886 and KDB 986446 D01 Covered Equipment Guidance section B(2a). Signed: Printed name: Roy Ryan Title: Manager Company Name: DP AUDIO VIDEO LLC Date: 8/25/2025

Attestation Statements

DP AUDIO VIDEO LLC * the applicant must designate a contact located in the United States for purposes of acting as the applicant’s agent for service of process, regardless of whether the applicant is a domestic or foreign entity. An applicant located in the United States may designate itself as the agent for service of process. U.S. Agent Designation for Service of Process - Certification Attestation Letter Federal Communications Commission Authorization and Evaluation Division 7435 Oakland Mills Road Columbia, MD 21046 USA ATTN.: Reviewing Engineer FCC ID: 2AVRVCTP100LG01 FRN of applicant: 0029264256 Per section 2.911(d)(7) of the FCC rules, DP AUDIO VIDEO LLC certifies that the equipment for which authorization is sought is designated to the following U.S. agent* for service of process: Company Name: DP AUDIO VIDEO LLC FCC Registration Number (FRN): 0029264256 Physical U.S. Company Address: 1001 Gayley Avenue P.O. Box 24857, Los Angeles, California 90024, United States Contact Person: Roy Ryan Agent Email Address: [email protected] Telephone No: 001-3109661133 The above contact person accepts the obligation for service of process. The applicant accepts to maintain an agent for no less than one year after the grantee has terminated all marketing and importation or the conclusion of any Commission-related proceeding involving the equipment. Applicant Signed: Signed: Printed name: Roy Ryan Title: Manager Company Name: DP AUDIO VIDEO LLC Date: 8/25/2025 Agent Signed: Signed: Printed name: Roy Ryan Title: Manager Company Name: DP AUDIO VIDEO LLC Date: 8/25/2025

Cover Letter(s)

DATE : 2025-08-25 Federal Communications Commission Authorization & Evaluation Division 7345 Oakland Mills Road Columbia, Maryland 21046 Authority to Act as Agent On our behalf, I appoint Jason Wu of Global United Technology Services Co., Ltd.and No. 123-128, Tower A, Jinyuan Business Building, No.2, Laodong Industrial Zone, Xixiang Road, Baoan District, Shenzhen, Guangdong, China to act as our agent in the preparation of this application for equipment certification. I certify that submitted documents properly describe the device or system for which equipment certification is sought. I also certify that each unit manufactured, imported or marketed, as defined in the Federal Communications Commission’s regulations will have affixed to it a label identical to that submitted for approval with this application. For instances where our authorized agent signs the application for certification on our behalf, I acknowledge that all responsibility for complying with the terms and conditions for certification, still resides with DP AUDIO VIDEO LLC and 1001 Gayley Avenue P.O. Box 24857, Los Angeles, California 90024, United States Signature: Name: Roy Ryan Title: Manager Company: DP AUDIO VIDEO LLC

Cover Letter(s)

DP AUDIO VIDEO LLC DATE : 2025-08-25 Equipment Autorisation Division Federal Communications Commission 7435 Oakland Mills Road Columbia, MD 21046 FCC ID: 2AVRVCTP100LG01 Product Name: PROFESSIONAL WIRELESS THERMAL PRINTER Request for Confidentiality To Whom It May Concern, Pursuant to the provisions of the Commission’s rules Title 47 Sections §0.457 and §0.459, we are requesting the Commission to withhold the following attachment(s) as confidential documents from public disclosure indefinitely. These documents contain detailed system and equipment descriptions and are considered as proprietary information in operation of the equipment. The public disclosure of these documents might be harmful to our company and would give competitors an unfair advantage in the market. Schematic Diagram Block Diagram Operational Description It is our understanding that all measurement test reports, FCC ID label format and correspondence during the certification review process cannot be granted as confidential documents and this information will be available for public review once the grant of equipment authorization is issued. Signature: Name: Roy Ryan Title: Manager Company: DP AUDIO VIDEO LLC

External Photos

Page 1 of 3 Test Model No.: CTP100LG Page 2 of 3 Page 3 of 3

ID Label/Location Info

Label location

Internal Photos

Page 1 of 3 Test Model No.: CTP100LG Page 2 of 3 Page 3 of 3

RF Exposure Info

FCC ID: 2AVRVCTP100LG01 RF Exposure evaluation According to 447498 D04 Interim General RF Exposure Guidance v01 ERP/EIRP = P T +G T −L C ERP/EIRP is the equivalent (or effective) radiated power [in same units as P T , typically dBW, dBm, or power spectral density (psd)], relative to either a dipole antenna (ERP) or an isotropic antenna (EIRP). P T is the transmitter output power, in dBW, dBm, or psd (power over a specified reference bandwidth). G T is the gain of the transmitting antenna, in dBd (ERP) or dBi (EIRP). L C is the signal attenuation in the connecting cable between the transmitter and the antenna, in dB. Band Frequency (MHz) Output power (dBm) Ant gain (dBi) EIRP (dBm) EIRP (mW) ERP (dBm) ERP (mw) Distance (cm) P th (mW) BLE 2402 -2.252.81 0.561.14 -1.590.69 0.5 2.79 BT EDR 2402 1.60 2.81 4.412.76 2.261.68 0.5 2.79 Remark: ERP = EIRP −2.15 dB Then SAR evaluation is not required

Test Report

MVSILICON 上海山景集成电路股份有限公司 Shanghai Mountain View Silicon Co., Ltd 1 Inverted F Antenna Specification MANUFACTURE :SHANGHAI MOUNTAIN VIEW SILICON CO,. LTD PRODUCT NAME :MV_BP10xx PCB Antenna DATE:2019-10-30 MVSILICON 上海山景集成电路股份有限公司 Shanghai Mountain View Silicon Co., Ltd 2 1. Antenna describe Antenna plate : Inverted F Antenna Frequency range : 2.4GHz-2.48GHz ITEM Name Inverted F Antenna Specification Model Name2.4GHz Antenna PolarizationHorizontal and Vertical Azimuth Beam PattemOmni-directional Impedance50 Ohm Antenna Lengh14.4mm Gain(Max) 2.81(±1 dBi ) 2. Antenna Photo& Lengh ( mm ) MVSILICON 上海山景集成电路股份有限公司 Shanghai Mountain View Silicon Co., Ltd 3 3. Gain Frequency Gain ( dBi ) 2400MHz2.81 2410MHz2.74 2420MHz2.70 2430MHz2.73 2440MHz1.01 2450MHz1.26 2460MHz1.50 2470MHz1.49 2480MHz1.42 2490MHz0.36 2500MHz0.33 4. Return Loss/VSWR/Input Impedance Frequency Return Loss (dB)VSWR Input Impedance( Ω) 2400MHz-7.232.5325.37 2400MHz-6.472.8017.99 2450MHz-6.222.9017.18 2480MHz-5.183.4415.55 2500MHz-4.563.8915.48 MVSILICON 上海山景集成电路股份有限公司 Shanghai Mountain View Silicon Co., Ltd 4 Annex A Photographs 1. Test Setup Annex B Figures 1.2D Radiation Pattern Phi=0° MVSILICON 上海山景集成电路股份有限公司 Shanghai Mountain View Silicon Co., Ltd 5 Phi=90° Theta=90° MVSILICON 上海山景集成电路股份有限公司 Shanghai Mountain View Silicon Co., Ltd 6 2.3D Radiation Pattern 2400MHz 2450MHz MVSILICON 上海山景集成电路股份有限公司 Shanghai Mountain View Silicon Co., Ltd 7 2500MH 3.Return Loss MVSILICON 上海山景集成电路股份有限公司 Shanghai Mountain View Silicon Co., Ltd 8 4.VSWR END

Test Report

Global United Technology Services Co., Ltd. Report No.: GTS2025080304F01 Authorized Signature: Robinson Luo Laboratory Manager This results shown in this test report refer only to the sample(s) tested, this test report cannot be reproduced, except in full, without prior written permission of the company. The report would be invalid without specific stamp of test institute and the signatures of compiler and approver. Page 1 of 27 TEST REPORT Applicant: DP AUDIO VIDEO LLC Address of Applicant: 1001 Gayley Avenue P.O. Box 24857, Los Angeles, California 90024, United States Manufacturer/Factory: SOBETTER BINH DUONG TRADING MANUFACTURE COMPANY LIMITED Address of Manufacturer/Factory: LOT E,ROAD D6,PHU CHANH INDUSTRIAL,BINH DUONG WARD,HO CHI MINH CITY,VIETNAM Equipment Under Test (EUT) Product Name: PROFESSIONAL WIRELESS THERMAL PRINTER Model No.: CTP100LG Trade Mark: CORE INNOVATIONS TM FCC ID: 2AVRVCTP100LG01 Applicable standards: FCC CFR Title 47 Part 15 Subpart C Section 15.247 Date of sample receipt: July 30, 2025 Date of Test: July 30-August 15, 2025 Date of report issued: August 15, 2025 Test Result : PASS * * In the configuration tested, the EUT complied with the standards specified above. Report No.: GTS2025080304F01 Global United Technology Services Co., Ltd. No. 123- 128, Tower A, Jinyuan Business Building, No.2, Laodong Industrial Zone, Xixiang Road, Baoan District, Shenzhen, Guangdong, China 518102 Telephone: +86 (0) 755 2779 8480 Fax: +86 (0) 755 2779 8960 Page 2 of 27 2 Version Version No. Date Description 00 August 15, 2025 Original Tested By: Date: August 15, 2025 Test Engineer Prepared By: Date: August 15, 2025 Project Engineer Check By: Date: August 15, 2025 Reviewer Report No.: GTS2025080304F01 Global United Technology Services Co., Ltd. No. 123- 128, Tower A, Jinyuan Business Building, No.2, Laodong Industrial Zone, Xixiang Road, Baoan District, Shenzhen, Guangdong, China 518102 Telephone: +86 (0) 755 2779 8480 Fax: +86 (0) 755 2779 8960 Page 3 of 27 3 Contents Page 1 COVER PAGE ........................................................................................................................................... 1 2 VERSION .................................................................................................................................................. 2 3 CONTENTS .............................................................................................................................................. 3 4 TEST SUMMARY ..................................................................................................................................... 4 5 GENERAL INFORMATION ...................................................................................................................... 5 5.1 GENERAL DESCRIPTION OF EUT ......................................................................................................... 5 5.2 TEST MODE ........................................................................................................................................ 7 5.3 DESCRIPTION OF SUPPORT UNITS ....................................................................................................... 7 5.4 DEVIATION FROM STANDARDS ............................................................................................................. 7 5.5 ABNORMALITIES FROM STANDARD CONDITIONS ................................................................................... 7 5.6 TEST FACILITY .................................................................................................................................... 7 5.7 TEST LOCATION ................................................................................................................................. 7 5.8 ADDITIONAL INSTRUCTIONS ................................................................................................................. 7 6 TEST INSTRUMENTS LIST ..................................................................................................................... 8 7 TEST RESULTS AND MEASUREMENT DATA .................................................................................... 10 7.1 ANTENNA REQUIREMENT ................................................................................................................... 10 7.2 CONDUCTED EMISSIONS ................................................................................................................... 11 7.3 CONDUCTED PEAK OUTPUT POWER .................................................................................................. 14 7.4 CHANNEL BANDWIDTH ...................................................................................................................... 15 7.5 POWER SPECTRAL DENSITY ............................................................................................................. 16 7.6 SPURIOUS EMISSION IN NON-RESTRICTED & RESTRICTED BANDS ....................................................... 17 7.6.1 Conducted Emission Method ..................................................................................................... 17 7.6.2 Radiated Emission Method ........................................................................................................ 18 8 TEST SETUP PHOTO ............................................................................................................................ 27 9 EUT CONSTRUCTIONAL DETAILS ..................................................................................................... 27 Report No.: GTS2025080304F01 Global United Technology Services Co., Ltd. No. 123- 128, Tower A, Jinyuan Business Building, No.2, Laodong Industrial Zone, Xixiang Road, Baoan District, Shenzhen, Guangdong, China 518102 Telephone: +86 (0) 755 2779 8480 Fax: +86 (0) 755 2779 8960 Page 4 of 27 4 Test Summary Test Item Section in CFR 47 Result Antenna requirement 15.203/15.247 (c) Pass AC Power Line Conducted Emission 15.207 P…

Text truncated - open the document above for the full version.

Test Report

Report No.: GTS2025080304F01 Global United Technology Services Co., Ltd. No. 123- 128, Tower A, Jinyuan Business Building, No.2, Laodong Industrial Zone, Xixiang Road, Baoan District, Shenzhen, Guangdong, China 518102 Telephone: +86 (0) 755 2779 8480 Fax: +86 (0) 755 2779 8960 Page 1 of 20 1. Duty Cycle 1.1 Test Result Ant1 Mode TX Type Frequency (MHz) T_on (ms) Period (ms) Duty Cycle (%) Duty Cycle Correction Factor (dB) Max. DC Variation (%) 1M SISO 2402 0.395 0.625 63.20 1.99 0.03 2440 0.394 0.625 63.04 2.00 0.03 2480 0.395 0.625 63.20 1.99 0.02 Report No.: GTS2025080304F01 Global United Technology Services Co., Ltd. No. 123- 128, Tower A, Jinyuan Business Building, No.2, Laodong Industrial Zone, Xixiang Road, Baoan District, Shenzhen, Guangdong, China 518102 Telephone: +86 (0) 755 2779 8480 Fax: +86 (0) 755 2779 8960 Page 2 of 20 1.2 Test Graph 1M_LCH_2402MHz_Ant1_NTNV 1M_MCH_2440MHz_Ant1_NTNV Report No.: GTS2025080304F01 Global United Technology Services Co., Ltd. No. 123- 128, Tower A, Jinyuan Business Building, No.2, Laodong Industrial Zone, Xixiang Road, Baoan District, Shenzhen, Guangdong, China 518102 Telephone: +86 (0) 755 2779 8480 Fax: +86 (0) 755 2779 8960 Page 3 of 20 1M_HCH_2480MHz_Ant1_NTNV Report No.: GTS2025080304F01 Global United Technology Services Co., Ltd. No. 123- 128, Tower A, Jinyuan Business Building, No.2, Laodong Industrial Zone, Xixiang Road, Baoan District, Shenzhen, Guangdong, China 518102 Telephone: +86 (0) 755 2779 8480 Fax: +86 (0) 755 2779 8960 Page 4 of 20 2. Bandwidth 2.1 Test Result 2.1.1 OBW Mode TX Type Frequency (MHz) ANT 99% Occupied Bandwidth (MHz) Verdict Result Limit 1M SISO 2402 1 1.022 / Pass 2440 1 1.021 / Pass 2480 1 1.021 / Pass 2.1.2 6dB BW Mode TX Type Frequency (MHz) ANT 6dB Bandwidth (MHz) Verdict Result Limit 1M SISO 2402 1 0.690 >=0.5 Pass 2440 1 0.688 >=0.5 Pass 2480 1 0.693 >=0.5 Pass Report No.: GTS2025080304F01 Global United Technology Services Co., Ltd. No. 123- 128, Tower A, Jinyuan Business Building, No.2, Laodong Industrial Zone, Xixiang Road, Baoan District, Shenzhen, Guangdong, China 518102 Telephone: +86 (0) 755 2779 8480 Fax: +86 (0) 755 2779 8960 Page 5 of 20 2.2 Test Graph 2.2.1 OBW 1M_LCH_2402MHz_Ant1_NTNV 1M_MCH_2440MHz_Ant1_NTNV Report No.: GTS2025080304F01 Global United Technology Services Co., Ltd. No. 123- 128, Tower A, Jinyuan Business Building, No.2, Laodong Industrial Zone, Xixiang Road, Baoan District, Shenzhen, Guangdong, China 518102 Telephone: +86 (0) 755 2779 8480 Fax: +86 (0) 755 2779 8960 Page 6 of 20 1M_HCH_2480MHz_Ant1_NTNV Report No.: GTS2025080304F01 Global United Technology Services Co., Ltd. No. 123- 128, Tower A, Jinyuan Business Building, No.2, Laodong Industrial Zone, Xixiang Road, Baoan District, Shenzhen, Guangdong, China 518102 Telephone: +86 (0) 755 2779 8480 Fax: +86 (0) 755 2779 8960 Page 7 of 20 2.2.2 6dB BW 1M_LCH_2402MHz_Ant1_NTNV 1M_MCH_2440MHz_Ant1_NTNV Report No.: GTS2025080304F01 Global United Technology Services Co., Ltd. No. 123- 128, Tower A, Jinyuan Business Building, No.2, Laodong Industrial Zone, Xixiang Road, Baoan District, Shenzhen, Guangdong, China 518102 Telephone: +86 (0) 755 2779 8480 Fax: +86 (0) 755 2779 8960 Page 8 of 20 1M_HCH_2480MHz_Ant1_NTNV Report No.: GTS2025080304F01 Global United Technology Services Co., Ltd. No. 123- 128, Tower A, Jinyuan Business Building, No.2, Laodong Industrial Zone, Xixiang Road, Baoan District, Shenzhen, Guangdong, China 518102 Telephone: +86 (0) 755 2779 8480 Fax: +86 (0) 755 2779 8960 Page 9 of 20 3. Maximum Conducted Output Power 3.1 Test Result Mode TX Type Frequency (MHz) Maximum Peak Conducted Output Power (dBm) Verdict ANT1 Limit 1M SISO 2402 -2.25 <=30 Pass 2440 -2.41 <=30 Pass 2480 -3.29 <=30 Pass Report No.: GTS2025080304F01 Global United Technology Services Co., Ltd. No. 123- 128, Tower A, Jinyuan Business Building, No.2, Laodong Industrial Zone, Xixiang Road, Baoan District, Shenzhen, Guangdong, China 518102 Telephone: +86 (0) 755 2779 8480 Fax: +86 (0) 755 2779 8960 Page 10 of 20 3.2 Test Graph 1M_LCH_2402MHz_Ant1_NTNV 1M_MCH_2440MHz_Ant1_NTNV Report No.: GTS2025080304F01 Global United Technology Services Co., Ltd. No. 123- 128, Tower A, Jinyuan Business Building, No.2, Laodong Industrial Zone, Xixiang Road, Baoan District, Shenzhen, Guangdong, China 518102 Telephone: +86 (0) 755 2779 8480 Fax: +86 (0) 755 2779 8960 Page 11 of 20 1M_HCH_2480MHz_Ant1_NTNV Report No.: GTS2025080304F01 Global United Technology Services Co., Ltd. No. 123- 128, Tower A, Jinyuan Business Building, No.2, Laodong Industrial Zone, Xixiang Road, Baoan District, Shenzhen, Guangdong, China 518102 Telephone: +86 (0) 755 2779 8480 Fax: +86 (0) 755 2779 8960 Page 12 of 20 4. Maximum Power Spectral Density 4.1 Test Result Mode TX Type Frequency (MHz) Maximum PSD (dBm/3kHz) Verdict ANT1 Limit 1M SISO 2402 -17.59 <=8 Pass 2440 -17.77 <=8 Pass 2480 -18.59 <=8 Pass Report No.: GTS2025080304F01 Global United Technology Services Co., Ltd. No. 123- 128, Tower A, Jinyuan Business Building, No.2, Laodong Industrial Zone, Xixiang Road, Baoan District, Shenzhen, Guangdong, China 518102 Telephone: +86 (0) 755 2779 8480 Fax: +86 (0) 755 2779 8960 Page 13 of 20 4.2 Test Graph 1M_LCH_2402MHz_Ant1_NTNV 1M_MCH_2440MHz_Ant1_NTNV Report No.: GTS2025080304F01 Global United Technology Services Co., Ltd. No. 123- 128, Tower A, Jinyuan Business Building, No.2, Laodong Industrial Zone, Xixiang Road, Baoan District, Shenzhen, Guangdong, China 518102 Telephone: +86 (0) 755 2779 8480 Fax: +86 (0) 755 2779 8960 Page 14 of 20 1M_HCH_2480MHz_Ant1_NTNV Report No.: GTS2025080304F01 Global United Technology Services Co., Ltd. No. 123- 128, Tower A, Jinyuan Business Building, No.2, Laodong Industrial Zone, Xixiang Road, Baoan District, Shenzhen, Guangdong, China 518102 Telephone: +86 (0) 755 2779 8480 Fax: +86 (0) 755 2779 8960 Page 15 of 20 5. Unwanted Emissions In Non-restricted Frequency Bands 5.1 Test Result 5.1.1 Ref Mode TX Type Frequency (MHz) ANT Level of Reference (dBm) 1M SISO…

Text truncated - open the document above for the full version.

Test Setup Photos

Page 1 of 2 Test Model No.: CTP100LG Radiated Emission Page 2 of 2 Conducted Emissions RF Conducted Test

Contact Information

Applicant

Roy Ryan
[email protected]Fax: 001-310-966-1134

Test Firm

Global United Technology Services Co. Ltd.Robinson Lo
[email protected]Fax: 86-0-755-27798960

Technical Specifications

#Rule PartsFrequency RangePower Output
115C2.40 GHz - 2.48 GHz595.70 µW
Confidentiality
Long Term
Grant Notes
Power output listed is conducted.