FCCID.CO- FCC ID Database
HomeCompaniesEquipment ClassesSearch

© 2026 FCC ID Database. All rights reserved.

AboutContactData sourced from FCC public records
  1. Home/
  2. PS TEC Co., Ltd./
  3. 2AVSN-PSM-NGC-P01

2AVSN-PSM-NGC-P01Autonomous Counter

PS TEC Co., Ltd.
Autonomous Counter - FCC ID 2AVSN-PSM-NGC-P01 - PS TEC Co., Ltd.
Click to zoom

Application Details

Equipment Class
DTS - Digital Transmission System
Date of Grant
Jul 12, 2020
Application Purpose
Original Equipment
Date of Application
Jul 12, 2020
Equipment Note
Autonomous Counter
Frequency Range
2402.00000000 - 2480.00000000
Company
PS TEC Co., Ltd.
Country
South Korea

Documents & Files

Select a file to view

Users Manual

↗

Cover Letter(s)

↗

External Photos

↗

ID Label/Location Info

↗

Internal Photos

↗

RF Exposure Info

↗

Test Report

↗

Test Setup Photos

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

Users Manual

 FCC Information to User This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one of the following measures: •Reorient or relocate the receiving antenna. •Increase the separation between the equipment and receiver. •Connect the equipment into an outlet on a circuit different from that to which the receiver is con-nected. •Consult the dealer or an experienced radio/TV technician for help. Caution Modifications not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment. FCC Compliance Information : This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. This equipment complies with FCC RF radiation exposure limits set forth for an uncontrolled environment. This equipment should be installed and operated with a minimum distance of 20 centimeters between the radiator and your body. This transmitter must not be co-located or operating in conjunction with any other antenna or transmitter.

Cover Letter(s)

SCS-F19: Confidentiality Request Letter Page 1 of 3 Rev 6.0 775 Montague Expressway Milpitas, CA 95035 Tel: 408-526-1188 Fax: 408-526-1088 Email: [email protected] Confidentiality Request Letter Reason for Amendment (current / obsolete) Revision History Approved Date From To Initial Release (obsolete) 1.0 1.0 Nov-14-2006 Adding CFR 2.459 (obsolete) 1.0 2.0 August – 11 - 2008 Updated company template & Added text box (obsolete) 2.0 3.0 Jan-31-2012 Added IC confidentiality letter form (obsolete) 3.0 4.0 March-26-2015 Corrections to STC form. Added reference to KDB (obsolete) 4.0 5.0 Nov-19-2015 Updated company logo (current) 5.0 6.0 Jun-26-2019 SCS-F19: Confidentiality Request Letter Page 2 of 3 Rev 6.0 PS TEC Co., Ltd. (July 03, 2020) To: Federal Communications Commission Authorization and Evaluation Division 7435 Oakland Mills Road Columbia, MD Subject: Permanent Confidentiality Request for FCC ID: 2AVSN-PSM-NGC-P01 Pursuant to sections 0.457 and 0.459 of CFR 47, we respectfully request permanent confidential treatment of the following Exhibits accompanying this application as: Block Diagram Schematics Operational Description The above materials contain trade secrets and proprietary information not customarily released to the public. The public disclosure of these materials may be harmful to the applicant and provide unjustified benefits to its competitors. The applicant understands that disclosure of this application and all accompanying documentation will not be made before the date of the Grant for this application. Sincerely, _____________________________ Client’s signature Client’s name / title : Bo Young Hwang/General Manager Contact information / address : 80, HWANGGEUM 3-RO 7BEON-GIL, YANGCHON-EUP, GIMPO-SI, GYEONGGI-DO, KOREA Telephone: +82-2-3408-1750 Fax No.: +82-2-3408-1740 E-mail: [email protected] SCS-F19: Confidentiality Request Letter Page 3 of 3 Rev 6.0 PS TEC Co., Ltd. (July 03, 2020) To: Federal Communications Commission Office of Engineering and Technology Equipment Authorization Division 7345 Oakland Mills Road Columbia, Maryland 21046 Subject: Short Term Confidentiality Request for FCC ID: 2AVSN-PSM-NGC-P01 To Whom It May Concern: Pursuant to sections 0.457 and 0.459 of CFR 47, and to avoid premature release of sensitive information prior to marketing or release of the product to the public, the applicant requests the following documents contained in this certification application be temporarily withheld from public disclosure for an initial period of 45 or 180 days; or for a specified date of / / not to exceed 180 days from the Grant Date. See KDB 726920. User Manual Internal Photos Test Setup photos External Photos The above materials contain trade secrets and proprietary information not customarily released to the public. The public disclosure of these materials may be harmful to the applicant and provide unjustified benefits to its competitors. Sincerely, _____________________________ Client’s signature Client’s name / title : Bo Young Hwang/General Manager Contact information / address : 80, HWANGGEUM 3-RO 7BEON-GIL, YANGCHON-EUP, GIMPO-SI, GYEONGGI-DO, KOREA Telephone: +82-2-3408-1750 Fax No.: +82-2-3408-1740 E-mail: [email protected]

ID Label/Location Info

FCC ID LABEL LOCATION 1. FCC ID label drawing 2. FCC ID label location FCC ID: 2AVSN-PSM-NGC-P01 Made in Korea

Internal Photos

Chip Antenna

RF Exposure Info

Page 1 of 7 Report No. : OT-204-RWD-078 It should not be reproduced except in full, without the written approval of ONETECH Corp. EMC-003 (Rev.2) ONETECH Corp.: 43-14, Jinsaegol-gil, Chowol-eup, Gwangju-si, Gyeonggi-do, 12735, Korea (TEL: 82-31-799-9500, FAX: 82-31-799-9599) EMF TEST REPORT Test Report No. : OT-204-RWD-078 AGR No. : A201A-395 Applicant : PS TEC Co., Ltd. Address : 80, HWANGGEUM 3-RO 7BEON-GIL, YANGCHON-EUP, GIMPO-SI, GYEONGGI-DO, KOREA Manufacturer : PS TEC Co., Ltd. Address : 80, HWANGGEUM 3-RO 7BEON-GIL, YANGCHON-EUP, GIMPO-SI, GYEONGGI-DO, KOREA Type of Equipment : Autonomous Counter FCC ID. : 2AVSN-PSM-NGC-P01 Model Name : PSM-NGC-P01 Multiple Model Name : N/A Serial number : N/A Total page of Report : 7 pages (including this page) Date of Incoming : February 05, 2020 Date of issue : April 24, 2020 SUMMARY The equipment complies with the regulation; FCC PART 15 SUBPART C Section 15.247 This test report only contains the result of a single test of the sample supplied for the examination. It is not a generally valid assessment of the features of the respective products of the mass-production. Reviewed by: Approved by: Ha-Ram Lee / Manager Jae-Ho Lee / General Manager ONETECH Corp. ONETECH Corp. Page 2 of 7 Report No. : OT-204-RWD-078 It should not be reproduced except in full, without the written approval of ONETECH Corp. EMC-003 (Rev.2) ONETECH Corp.: 43-14, Jinsaegol-gil, Chowol-eup, Gwangju-si, Gyeonggi-do, 12735, Korea (TEL: 82-31-799-9500, FAX: 82-31-799-9599) CONTENTS PAGE 1. VERIFICATION OF COMPLIANCE ............................................................................................................................. 4 2. GENERAL INFORMATION ............................................................................................................................................ 5 2.1 PRODUCT DESCRIPTION ................................................................................................................................................. 5 2.2 ALTERNATIVE TYPE(S)/MODEL(S); ALSO COVERED BY THIS TEST REPORT. ................................................................ 5 3. EUT MODIFICATIONS .................................................................................................................................................... 5 4. RF EXPOSURE EVALUATION ...................................................................................................................................... 6 4.1 RF EXPOSURE CALCULATION ....................................................................................................................................... 6 4.2 EUT DESCRIPTION ......................................................................................................................................................... 6 4.3 TEST RESULT OF SAR EXCLUSION ............................................................................................................................... 7 Page 3 of 7 Report No. : OT-204-RWD-078 It should not be reproduced except in full, without the written approval of ONETECH Corp. EMC-003 (Rev.2) ONETECH Corp.: 43-14, Jinsaegol-gil, Chowol-eup, Gwangju-si, Gyeonggi-do, 12735, Korea (TEL: 82-31-799-9500, FAX: 82-31-799-9599) Revision History Rev. No. Issue Report No. Issued Date Revisions Section Affected 0 OT-204-RWD-078 April 24, 2020 Initial Issue All Page 4 of 7 Report No. : OT-204-RWD-078 It should not be reproduced except in full, without the written approval of ONETECH Corp. EMC-003 (Rev.2) ONETECH Corp.: 43-14, Jinsaegol-gil, Chowol-eup, Gwangju-si, Gyeonggi-do, 12735, Korea (TEL: 82-31-799-9500, FAX: 82-31-799-9599) 1. VERIFICATION OF COMPLIANCE Applicant : PS TEC Co., Ltd. Address : 80, HWANGGEUM 3-RO 7BEON-GIL, YANGCHON-EUP, GIMPO-SI, GYEONGGI-DO, KOREA Contact Person : Bo Young Hwang/General Manager Telephone No. : +82-2-3408-1750 FCC ID : 2AVSN-PSM-NGC-P01 Model Name : PSM-NGC-P01 Brand Name : N/A Serial Number : N/A Date : April 24, 2020 EQUIPMENT CLASS DTS – DIGITAL TRNSMISSION SYSTEM E.U.T. DESCRIPTION Autonomous Counter THIS REPORT CONCERNS Original Grant MEASUREMENT PROCEDURES ANSI C63.10: 2013 TYPE OF EQUIPMENT TESTED Pre-Production KIND OF EQUIPMENT AUTHORIZATION REQUESTED Certification EQUIPMENT WILL BE OPERATED UNDER FCC RULES PART(S) FCC PART 15 SUBPART C Section 15.247 Modifications on the Equipment to Achieve Compliance None Final Test was Conducted On 3 m, Semi Anechoic Chamber -. The above equipment was tested by ONETECH Corp. for compliance with the requirement set forth in the FCC Rules and Regulations. This said equipment in the configuration described in this report, shows the maximum emission levels emanating from equipment are within the compliance requirements. Page 5 of 7 Report No. : OT-204-RWD-078 It should not be reproduced except in full, without the written approval of ONETECH Corp. EMC-003 (Rev.2) ONETECH Corp.: 43-14, Jinsaegol-gil, Chowol-eup, Gwangju-si, Gyeonggi-do, 12735, Korea (TEL: 82-31-799-9500, FAX: 82-31-799-9599) 2. GENERAL INFORMATION 2.1 Product Description The PS TEC Co., Ltd., Model PSM-NGC-P01 (referred to as the EUT in this report) is an Autonomous Counter. The product specification described herein was obtained from product data sheet or user’s manual. DEVICE TYPE Autonomous Counter OPERATING FREQUENCY 2 402 MHz ~ 2 480 MHz RF OUTPUT POWER -1.56 dBm NUMBER OF CHANNEL 40 Channels MODULATION TYPE GFSK(Bluetooth LE) ANTENNA TYPE Chip Antenna ANTENNA GAIN 2.31 dBi LIST OF EACH OSC. OR CRYSTAL. FREQ.(FREQ.>=1 MHz) 32 MHz 2.2 Alternative type(s)/model(s); also covered by this test report. -. None 3. EUT MODIFICATIONS -. None Page 6 of 7 Report No. : OT-204-RWD-078 It should not be reproduced except in full, without the written approval of ONETECH Corp. EMC-003 (Rev.2) ONETECH Corp.: 43-14, Jinsaegol-gil, Chowol-eup, Gwangju-si, Gyeonggi-do, 12735, Korea (TEL: 82-31-799-9500, FAX: 82-31-799-9599) 4. RF EXPOSURE EVALUATION 4.1 RF Exposure Calculation …

Text truncated - open the document above for the full version.

Test Report

Page 1 of 33 Report No. : OT-204-RWD-079 It should not be reproduced except in full, without the written approval of ONETECH Corp. EMC-003 (Rev.2) ONETECH Corp.: 43-14, Jinsaegol-gil, Chowol-eup, Gwangju-si, Gyeonggi-do, 12735, Korea (TEL: 82-31-799-9500, FAX: 82-31-799-9599) RADIO PERFORMANCE TEST REPORT Test Report No. : OT-204-RWD-079 AGR No. : A201A-395 Applicant : PS TEC Co., Ltd. Address : 80, HWANGGEUM 3-RO 7BEON-GIL, YANGCHON-EUP, GIMPO-SI, GYEONGGI-DO, KOREA Manufacturer : PS TEC Co., Ltd. Address : 80, HWANGGEUM 3-RO 7BEON-GIL, YANGCHON-EUP, GIMPO-SI, GYEONGGI-DO, KOREA Type of Equipment : Autonomous Counter FCC ID. : 2AVSN-PSM-NGC-P01 Model Name : PSM-NGC-P01 Multiple Model Name : N/A Serial number : N/A Total page of Report : 33 pages (including this page) Date of Incoming : February 05, 2020 Date of issue : April 24, 2020 SUMMARY The equipment complies with the regulation; FCC PART 15 SUBPART C Section 15.247 This test report only contains the result of a single test of the sample supplied for the examination. It is not a generally valid assessment of the features of the respective products of the mass-production. Reviewed by: Approved by: Ha-Ram Lee / Manager Jae-Ho Lee / General Manager ONETECH Corp. ONETECH Corp. Page 2 of 33 Report No. : OT-204-RWD-079 It should not be reproduced except in full, without the written approval of ONETECH Corp. EMC-003 (Rev.2) ONETECH Corp.: 43-14, Jinsaegol-gil, Chowol-eup, Gwangju-si, Gyeonggi-do, 12735, Korea (TEL: 82-31-799-9500, FAX: 82-31-799-9599) CONTENTS PAGE 1. VERIFICATION OF COMPLIANCE ............................................................................................................................. 5 2. TEST SUMMARY .............................................................................................................................................................. 6 2.1 TEST ITEMS AND RESULTS ............................................................................................................................................. 6 2.2 ADDITIONS, DEVIATIONS, EXCLUSIONS FROM STANDARDS ........................................................................................... 6 2.3 RELATED SUBMITTAL(S) / GRANT(S) ............................................................................................................................ 6 2.4 PURPOSE OF THE TEST ................................................................................................................................................... 6 2.5 TEST METHODOLOGY .................................................................................................................................................... 6 2.6 TEST FACILITY ............................................................................................................................................................... 6 3. GENERAL INFORMATION ............................................................................................................................................ 7 3.1 PRODUCT DESCRIPTION ................................................................................................................................................. 7 4. EUT MODIFICATIONS .................................................................................................................................................... 7 5. SYSTEM TEST CONFIGURATION ............................................................................................................................... 8 5.1 JUSTIFICATION ............................................................................................................................................................... 8 5.2 PERIPHERAL EQUIPMENT .............................................................................................................................................. 8 5.3 MODE OF OPERATION DURING THE TEST ...................................................................................................................... 8 5.4 CONFIGURATION OF TEST SYSTEM ............................................................................................................................. 10 5.5 ANTENNA REQUIREMENT ............................................................................................................................................ 10 6. PRELIMINARY TEST .................................................................................................................................................... 10 6.1 AC POWER LINE CONDUCTED EMISSIONS TESTS ....................................................................................................... 10 6.2 GENERAL RADIATED EMISSIONS TESTS ..................................................................................................................... 10 7. MIMIMUM 6 DB BANDWIDTH ................................................................................................................................... 11 7.1 OPERATING ENVIRONMENT ......................................................................................................................................... 11 7.2 TEST SET-UP ................................................................................................................................................................. 11 7.3 TEST EQUIPMENT USED ................................................................................................................................................ 11 7.4 TEST DATA .................................................................................................................................................................... 12 8. MAXIMUM PEAK OUTPUT POWER ......................................................................................................................... 14 8.1 OPERATING ENVIRONMENT ......................................................................................…

Text truncated - open the document above for the full version.

Contact Information

Applicant

Bo Young Hwang(General Manager)
[email protected]+82-2-3408-1750Fax: +82-2-3408-1740

Test Firm

ONETECH Corp.Ki Hong Nam
[email protected]82-31-799-9580Fax: 82-31-799-9599

Technical Specifications

#Rule PartsFrequency RangePower Output
115C2.40 GHz - 2.48 GHz600.00 µW
Confidentiality
Long Term
Grant Notes
The output power listed is conducted. This device must be installed to provide a separation distance of at least 20 cm from all persons and must not be co-located or operating in conjunction with any other antenna or transmitter, except in accordance with FCC multi-transmitter product procedures. End-users must be informed of the operating requirements for satisfying RF exposure compliance.

Other Applications from PS TEC Co., Ltd.

Autonomous Terminal - FCC ID 2AVSN-PSM-NGT-G01 - PS TEC Co., Ltd.
2AVSN-PSM-NGT-G01

Autonomous Terminal

Apr 27, 2021

Equipment Class

DTS - Digital Transmission System
Autonomous Counter - FCC ID 2AVSN-PSM-NGC-NP01 - PS TEC Co., Ltd.
2AVSN-PSM-NGC-NP01

Autonomous Counter

May 13, 2020

Equipment Class

DTS - Digital Transmission System