FCCID.CO- FCC ID Database
HomeCompaniesEquipment ClassesSearch

© 2026 FCC ID Database. All rights reserved.

AboutContactData sourced from FCC public records
  1. Home/
  2. Ergotron Inc./
  3. 2AVU2MP100B

2AVU2MP100BMP100-B Pack

Ergotron Inc.

Application Details

Equipment Class
DTS - Digital Transmission System
Date of Grant
Feb 13, 2026
Application Purpose
Original Equipment
Equipment Note
MP100-B Pack
Frequency Range
2402.00000000 - 2480.00000000
Company
Ergotron Inc.
Country
United States

Documents & Files

Select a file to view

Attestation Statements

↗
↗
↗

Cover Letter(s)

↗
↗

ID Label/Location Info

↗

RF Exposure Info

↗

Test Report

↗
↗

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

Attestation Statements

Ergotron Inc. 2.911 (d)(5)(i) Equipment Type Attestation v1.2 Section 2.911(d)(5)(i) Certification – EquipmentType Company name: Ergotron Inc. Address: 1181 Trapp Rd, Saint Paul, Minnesota 55121, United States Product Name: MP100-B Pack FCC ID: 2AVU2MP100B Model(s): MP100-B 2.911(d)(5)(i) EquipmentType We, [ Ergotron Inc.] ( “the applicant”) certify that the equipment for which authorization is sought through certification is not: •P rohibited from receiving an equipment authorization pursuant to § 2.903; of the FCC rules. •Identified as an equipment type in the “Covered List” NOTE 1 Y ours sincerely, Name: Cameron Boone Date: 2026-02-05 Ti tle and Company name: Manager /Ergotron Inc. NOTE 1 “Covered List ”; is the List of Equipment and Services Covered By Section 2 of The Secure Networks Act, available at https://www.fcc.gov/supplychain/coveredlist R eferences; 1)986446 D01 Covered Equipment v01 https://apps.fcc.gov/oetcf/kdb/forms/FTSSearchResultPage.cfm?switch=P&id=325672 2) F ederal Register document 2022-28263 published on 02/06/23 https://www.federalregister.gov/documents/2023/02/06/2022-28263/protecting-against-national-security-threats-to-the-com munications-supply-chain-through-the

Attestation Statements

2.911 (d)(5)(ii) Applicant Attestation v1.3 Ergotron Inc. Section 2.911(d)(5)(ii) Certification – Applicant (Covered List ) Company name: Ergotron Inc. Address: 1181 Trapp Rd, Saint Paul, Minnesota 55121, United States Product Name: MP100-B Pack FCC ID: 2AVU2MP100B Model(s): MP100-B 2.911(d)(5)(ii) Applicant filing We, [ Ergotron Inc.] ( “the applicant”) certify that, as of t he date of t he filing of the application, the applicant is not identified NOTE 1 on the “Covered List” NOTE 2 ,established pursuant to §1.50002 of this chapter,as an entity producing coveredcommunications equipment. Yours sincerely , Name: Cameron Boone Date: 2026-02-05 Ti tle and Company name: Manager /Ergotron Inc. NOTE 1 Delete option not applicable to this application. NOTE 2 “Covered List ”; is the List of Equipment and Services Covered By Section 2 of The Secure Networks Act, available at https://www.fcc.gov/supplychain/coveredlist References; 1)986446 D01 Covered Equipment v01 https://apps.fcc.gov/oetcf/kdb/forms/FTSSearchResultPage.cfm?switch=P&id=325672 2) F ederal Register document 2022-28263 published on 02/06/23 https://www.federalregister.gov/documents/2023/02/06/2022-28263/protecting-against-national-security-threats-to-the-com munications-supply-chain-through-the

Attestation Statements

Ergotron Inc. 2.911 (d)(7)USA Agent v1.5 Section 2.911(d)(7) USA Agent for Service of Process Company name: Ergotron Inc. Address: 1181 Trapp Rd, Saint Paul, Minnesota 55121, United States Product Name: MP100-B Pack FCCID: 2AVU2MP100B Model(s): MP100-B 2.911(d)(7) USA Designated Agent for Service of Process We, [ Ergotron Inc.] (“the applicant”) designate [Ergotron Inc.] NOTE1 for the purpose of accepting service of process on behalf of the applicant. Applicant consent:We acknowledgeour consent to accept service of process in the United States for matters related to the applicable equipment, and at the physical U.S. address and email address of the designated agent and acknowledgeour acceptance of our obligation to maintain an agent for service of process in the United States for no less than one year after either we the grantee have permanently terminated all marketing and importation of the applicable equipment within the U.S., or at the conclusion of any Commission-related administrative or judicial proceeding involving the equipment, whichever is later. Agent obligation:We acknowledgeourobligation to accept service of process in the United States for matters related to the applicable equipment at our physical U.S. address and email addressfor no less than one year after either the grantee has permanently terminated all marketing and importation of the applicable equipment within the U.S., or at the conclusion of any Commission-related administrative or judicial proceeding involving the equipment, whichever is later. USA Agent Company name: Ergotron Inc. USA Address: 1181 Trapp Rd, Saint Paul, Minnesota 55121, United States FRN Number: 0029266434 Contact Name: Cameron Boone Telephone No: 615-896-1652 Email: [email protected] Applicant Company name: Ergotron Inc. Address: 1181 Trapp Rd, Saint Paul, Minnesota 55121, United States Grantee FRN Number: 0029266434 FCC Grantee Code: 2AVU2 Contact Name: Cameron Boone Telephone No: 615-896-1652 Email: [email protected] Signature: Title: Manager Signature: Title: Manager Date:2026-02-05 Date: 2026-02-05 Ergotron Inc. 2.911 (d)(7)USA Agent v1.5 NOTE 1: An applicant located in the United States may designate itself as the agent for service of process. Reference; Federal Register document 2022-28263 published on 02/06/23 https://www.federalregister.gov/documents/2023/02/06/2022-28263/protecting-against-nation al-security-threats-to-the-communications-supply-chain-through-the

Cover Letter(s)

Ergotron Inc. 1181 Trapp Rd, Saint Paul, Minnesota 55121, United States Agent Authorization Company: Ergotron Inc. Address: 1181 Trapp Rd, Saint Paul, Minnesota 55121, United States Product Name: MP100-B Pack Model Number(s): MP100-B Product Description: MP100-B Pack We authorize MiCOM Labs Inc., 575 Boulder Court, Pleasanton, California 94566, USA, to act on our behalf on all matters concerning the certification of above named equipment. We declare that MiCOM Labs Inc. is allowed to forward all information related to the approval and certification of equipment to the regulatory agencies as required and to discuss any issues concerning the approval application. Any and all acts carried out by MiCOM Labs on our behalf shall have the same effect as acts of our own. Signature: Date: 2026-02-05 Name: Cameron Boone Title: Manager Company: Ergotron Inc.

Cover Letter(s)

O ffice of Engineering Technology Federal Communications Commission 7435 Oakland Mills Road Columbia, MD 21046 USA Date: 02-05-2026 Subject; Request for Confidentiality FCC ID: 2AVU2MP100B T o Whom It May Concern, Pursuant to the provisions of the Commission’s rules Title 47 Sections §0.457 and §0.459, we are requesting the Commission to withhold the following attachment(s) as confidential documents from public disclosure indefinitely. T hese documents contain detailed system and equipment descriptions and are considered as proprietary information in operation of the equipment. The public disclosure of these documents might be harmful to our company and would give competitors an unfair advantage in the market. Schematic Diagram Block Diagram Operational Description Tune-up Procedure I n additional to above mentioned documents, in order to comply with the marketing regulations in Title 47 CFR §2.803 and the importation rules in Title 47 CFR §2.1204, while ensuring that business sensitive information remains confidential until the actual marketing of newly authorized devices, we request Short Term Confidentiality of the following attachment(s); External Photos Test Setup Photos Internal Photos User Manual For 45 days, pursuant to Public Notice DA 04-1705. OR For 180 days pursuantto KDB 726920 D01. I t is our understanding that all measurement test reports, FCC ID label format and correspondence during the certification review process cannot be granted as confidential documents and this information will be available for public review once the grant of equipment authorization is issued. S incerely, Signature: N ame: Cameron Boone Title: Manager

ID Label/Location Info

9mm61mm 30mm 10mm 71mm 30mm 19.5mm 40mm Label Artwork and Location Model: MP100-B Label and size: Location

RF Exposure Info

Hotline: 400-6611-140 Tel: 86-755-27673339 Fax: 86-755-27673332 http://www.tct-lab.com TEST REPORT FCC ID. ............................ : 2AVU2MP100B Test Report No. ............... : TCT260126E015 Date of issue ................... : Feb. 03, 2026 Testing laboratory .......... : SHENZHEN TONGCE TESTING LAB Testing location/ address: 2101 & 2201, Zhenchang Factory, Renshan Industrial Zone, Fuhai Subdistrict, Bao'an District, Shenzhen, Guangdong, 518103, People's Republic of China Applicant's name ............ : Ergotron Inc. Address ........................... : 1181 Trapp Rd, Saint Paul, Minnesota 55121, United States Manufacturer's name ... : Hetai Electronics (Jiangxi) Co., Ltd. Address ........................... : Building 3, Binjiang Road, Songshan District, Quannan County Industrial Park, Ganzhou City, Jiangxi Province, China Standard(s) ..................... : KDB 447498 D01 General RF Exposure Guidance v06 FCC CFR Title 47 Part 2.1093 Product Name ................. : MP100-B Pack Trade Mark ...................... : N/A Model/Type reference..... : MP100-B Rating(s).......................... : Rechargeable Li-ion Battery DC 14.6V Date of receipt of test item ......................................... : Jan. 26, 2026 Date (s) of performance of test ................................... : Jan. 26, 2026 ~ Feb. 03, 2026 Tested by (+signature) ... : Yannie ZHONG Check by (+signature) .... : Beryl ZHAO Approved by (+signature): Tomsin General disclaimer: This report shall not be reproduced except in full, without the written approval of SHENZHEN TONGCE TESTING LAB. This document may be altered or revised by SHENZHEN TONGCE TESTING LAB personnel only, and shall be noted in the revision section of the document. The test results in the report only apply to the tested sample. Report No.: TCT260126E015 Page 2 of 6 Hotline: 400-6611-140 Tel: 86-755-27673339 Fax: 86-755-27673332 http://www.tct-lab.com Table of Contents 1. General Product Information .................................................................. 3 1.1. EUT description ..................................................................................................... 3 1.2. Model(s) list ............................................................................................................ 3 2. General Information ................................................................................. 4 2.1. Test environment and mode ................................................................................. 4 2.2. Description of Support Units ................................................................................ 4 3. Facilities and Accreditations .................................................................. 5 3.1. Facilities ................................................................................................................. 5 3.2. Location ................................................................................................................. 5 4. Test Results and Measurement Data ..................................................... 6 Report No.: TCT260126E015 Page 3 of 6 Hotline: 400-6611-140 Tel: 86-755-27673339 Fax: 86-755-27673332 http://www.tct-lab.com 1. General Product Information 1.1. EUT description Product Name ....................... : MP100-B Pack Model/Type reference........... : MP100-B Sample Number....................: TCT260126E014-0101 Operation Frequency ........... : 2402MHz~2480MHz Modulation Type ................... : GFSK Antenna Type ........................ : FPC Antenna Antenna Gain ........................ : 2.81dBi Rating(s)................................ : Rechargeable Li-ion Battery DC 14.6V Note: The antenna gain listed in this report is provided by applicant, and the test laboratory is not responsible for this parameter. 1.2. Model(s) list None. Report No.: TCT260126E015 Page 4 of 6 Hotline: 400-6611-140 Tel: 86-755-27673339 Fax: 86-755-27673332 http://www.tct-lab.com 2. General Information 2.1. Test environment and mode Item Normal condition Temperature +25ºC Voltage DC 14.6V Humidity 56% Atmospheric Pressure: 1008 mbar Test Mode: Engineering mode: Keep the EUT in continuous transmitting by select channel 2.2. Description of Support Units The EUT has been tested as an independent unit together with other necessary accessories or support units. The following support units or accessories were used to form a representative test configuration during the tests. Equipment Model No. Serial No. FCC ID Trade Name / / / / / Note: 1. All the equipment/cables were placed in the worst-case configuration to maximize the emission during the test. 2. Grounding was established in accordance with the manufacturer’s requirements and conditions for the intended use. 3. For conducted measurements (Output Power, 20dB Occupied Bandwidth, Carrier Frequencies Separation, Hopping Channel Number, Dwell Time, Spurious Emissions), the antenna of EUT is connected to the test equipment via temporary antenna connector, the antenna connector is soldered on the antenna port of EUT, and the temporary antenna connector is listed in the Test Instruments. Report No.: TCT260126E015 Page 5 of 6 Hotline: 400-6611-140 Tel: 86-755-27673339 Fax: 86-755-27673332 http://www.tct-lab.com 3. Facilities and Accreditations 3.1. Facilities The test facility is recognized, certified, or accredited by the following organizations: ● FCC - Registration No.: 645098 SHENZHEN TONGCE TESTING LAB Designation Number: CN1205 The testing lab has been registered and fully described in a report with the (FCC) Federal Communications Commission. The acceptance letter from the FCC is maintained in our files. ● A2LA-No.: 4320.01 SHENZHEN TONGCE TESTING LAB The testing lab has been accredited in accordance with the recognized International Standard ISO/IEC 17025:2017 General requirements for the competence of testing and calibration laboratories. 3.2. Location SHENZHEN TONGCE TESTING LAB Address: 2101 & 2201, Zhenchang F…

Text truncated - open the document above for the full version.

Test Report

深圳祥博一科技有限公司 电话Telephone:0755-29369912传真Portraiture:0755-61624200 研发中心:深圳市龙华区油松路95号油松文创园文成楼一楼101R&DCenter:101,1stfloor,Wencheng Building,YousongCulturalInnovationPark,No.95YousongRoad,LonghuaDistrict,Shenzhen 生产基地:东莞市塘厦镇138工业区裕华街7号华智创谷B栋5楼 Productionbase:5thfloor,BuildingB,HuazhiChuangValley,No.7,YuhuaStreet,138Industrial Zone,TangxiaTown,DongguanCity -1- / 10 客户名称 customername 鑫颖智能 项目名称/料号 Projectname HP1080 供方料号 Suppliermaterialnumber XBY250220 深圳祥博一科技有限公司 ShenzhenXiangboyiTechnologyCo.Ltd 规格承认书 Anacknowledgementofspecifications 深圳祥博一科技有限公司 电话Telephone:0755-29369912传真Portraiture:0755-61624200 研发中心:深圳市龙华区油松路95号油松文创园文成楼一楼101R&DCenter:101,1stfloor,Wencheng Building,YousongCulturalInnovationPark,No.95YousongRoad,LonghuaDistrict,Shenzhen 生产基地:东莞市塘厦镇138工业区裕华街7号华智创谷B栋5楼 Productionbase:5thfloor,BuildingB,HuazhiChuangValley,No.7,YuhuaStreet,138Industrial Zone,TangxiaTown,DongguanCity -2- / 10 客户确认Customerconfirmation 工程Engineer项目Project品质Quality批准Ratify 供方确认Confirmbythesupplier 结构Structure射频RadioFrequency批准Ratify 深圳祥博一科技有限公司 电话Telephone:0755-29369912传真Portraiture:0755-61624200 研发中心:深圳市龙华区油松路95号油松文创园文成楼一楼101R&DCenter:101,1stfloor,Wencheng Building,YousongCulturalInnovationPark,No.95YousongRoad,LonghuaDistrict,Shenzhen 生产基地:东莞市塘厦镇138工业区裕华街7号华智创谷B栋5楼 Productionbase:5thfloor,BuildingB,HuazhiChuangValley,No.7,YuhuaStreet,138Industrial Zone,TangxiaTown,DongguanCity -3- / 10 目录Catalogue 一.测试系统及设备TestSystemandEquipment........-4- 二.产品细节描述ProductDescription........................-5- 三.设备描述DeviceDescription.................................-6- 四.匹配电路MatchingCircuits..................................-6- 五.测试数据TestTata................................错误!未定义书签。 六.工程图EngineeringDrawing..................................-9- 七.组装方式/Assemblymethod......................................-10- 深圳祥博一科技有限公司 电话Telephone:0755-29369912传真Portraiture:0755-61624200 研发中心:深圳市龙华区油松路95号油松文创园文成楼一楼101R&DCenter:101,1stfloor,Wencheng Building,YousongCulturalInnovationPark,No.95YousongRoad,LonghuaDistrict,Shenzhen 生产基地:东莞市塘厦镇138工业区裕华街7号华智创谷B栋5楼 Productionbase:5thfloor,BuildingB,HuazhiChuangValley,No.7,YuhuaStreet,138Industrial Zone,TangxiaTown,DongguanCity -4- / 10 一.测试系统及设备TestSystemandEquipment 测试项目Testproject设备Equipment 1:S参数 parameters 1. 1. 回波损耗 回波损耗 S S mith mith roundabout roundabout 2. 2. 驻波比 驻波比 VSWR VSWR 网络分析仪 网络分析仪 N N etwork etwork analyzer analyzer : : A338/A333 A338/A333 HP8753D HP8753D 2:有源测试 activetest 综合测试仪 综合测试仪 C C omprehensive omprehensive test test instrument instrument : : Agilent Agilent 8960/ 8960/ CMW500 CMW500 3:无源测试 passivetest 1. 1. 天线效率 天线效率 Antenna Antenna efficiency efficiency 2. 2. 天线增 天线增 益 益 Antenna Antenna staff staff augmentation augmentation 1. 1. 暗室 暗室 D D arkroom arkroom : : 5x3x3 5x3x3 m m (ETS-3D) (ETS-3D) 2. 2. 网络分析仪 网络分析仪 N N etwork etwork analyzer analyzer : : HP HP 8753D 8753D 深圳祥博一科技有限公司 电话Telephone:0755-29369912传真Portraiture:0755-61624200 研发中心:深圳市龙华区油松路95号油松文创园文成楼一楼101R&DCenter:101,1stfloor,Wencheng Building,YousongCulturalInnovationPark,No.95YousongRoad,LonghuaDistrict,Shenzhen 生产基地:东莞市塘厦镇138工业区裕华街7号华智创谷B栋5楼 Productionbase:5thfloor,BuildingB,HuazhiChuangValley,No.7,YuhuaStreet,138Industrial Zone,TangxiaTown,DongguanCity -5- / 10 二.产品细节描述ProductDescription 技术要求 Technicalrequirements 技术指标 Technicalindex 备注comments onaform 工作频段 Band BT 频率范围 RangeOfFrequency 2400-2500Mhz 驻波比 VSWR <2.0 中心频率 CenterFrequency 输出阻抗 Impendance 50Ω 极化方式 Polarization 垂直极化 verticalpolarization 工作温度 operatingtemperature -20°C/+70°C 存储温度 storagetemperature 25°C±5°C 盐雾 SaltFog 24小时(24小时干湿交替) 24h(24halterningwet&dry) 无铅认证 RoHSCompliant 是 yes 深圳祥博一科技有限公司 电话Telephone:0755-29369912传真Portraiture:0755-61624200 研发中心:深圳市龙华区油松路95号油松文创园文成楼一楼101R&DCenter:101,1stfloor,Wencheng Building,YousongCulturalInnovationPark,No.95YousongRoad,LonghuaDistrict,Shenzhen 生产基地:东莞市塘厦镇138工业区裕华街7号华智创谷B栋5楼 Productionbase:5thfloor,BuildingB,HuazhiChuangValley,No.7,YuhuaStreet,138Industrial Zone,TangxiaTown,DongguanCity -6- / 10 三.设备描述DeviceDescription 整机图片 Fullmachineimage 四.匹配电路MatchingCircuits 匹配电路没有任何修改Thematchingcircuitremainsunchanged。 深圳祥博一科技有限公司 电话Telephone:0755-29369912传真Portraiture:0755-61624200 研发中心:深圳市龙华区油松路95号油松文创园文成楼一楼101R&DCenter:101,1stfloor,Wencheng Building,YousongCulturalInnovationPark,No.95YousongRoad,LonghuaDistrict,Shenzhen 生产基地:东莞市塘厦镇138工业区裕华街7号华智创谷B栋5楼 Productionbase:5thfloor,BuildingB,HuazhiChuangValley,No.7,YuhuaStreet,138Industrial Zone,TangxiaTown,DongguanCity -7- / 10 五.测试数据TestTata 深圳祥博一科技有限公司 电话Telephone:0755-29369912传真Portraiture:0755-61624200 研发中心:深圳市龙华区油松路95号油松文创园文成楼一楼101R&DCenter:101,1stfloor,Wencheng Building,YousongCulturalInnovationPark,No.95YousongRoad,LonghuaDistrict,Shenzhen 生产基地:东莞市塘厦镇138工业区裕华街7号华智创谷B栋5楼 Productionbase:5thfloor,BuildingB,HuazhiChuangValley,No.7,YuhuaStreet,138Industrial Zone,TangxiaTown,DongguanCity -8- / 10 深圳祥博一科技有限公司 电话Telephone:0755-29369912传真Portraiture:0755-61624200 研发中心:深圳市龙华区油松路95号油松文创园文成楼一楼101R&DCenter:101,1stfloor,Wencheng Building,YousongCulturalInnovationPark,No.95YousongRoad,LonghuaDistrict,Shenzhen 生产基地:东莞市塘厦镇138工业区裕华街7号华智创谷B栋5楼 Productionbase:5thfloor,BuildingB,HuazhiChuangValley,No.7,YuhuaStreet,138Industrial Zone,TangxiaTown,DongguanCity -9- / 10 六.工程图EngineeringDrawing 深圳祥博一科技有限公司 电话Telephone:0755-29369912传真Portraiture:0755-61624200 研发中心:深圳市龙华区油松路95号油松文创园文成楼一楼101R&DCenter:101,1stfloor,Wencheng Building,YousongCulturalInnovationPark,No.95YousongRoad,LonghuaDistrict,Shenzhen 生产基地:东莞市塘厦镇138工业区裕华街7号华智创谷B栋5楼 Productionbase:5thfloor,BuildingB,HuazhiChuangValley,No.7,YuhuaStreet,138Industrial Zone,TangxiaTown,DongguanCity -10- / 10 七.组装方式/Assemblymethod

Test Report

Hotline: 400-6611-140 Tel: 86-755-27673339 Fax: 86-755-27673332 http://www.tct-lab.com TEST REPORT FCC ID. ............................ : 2AVU2MP100B Test Report No. ............... : TCT260126E014 Date of issue ................... : Feb. 03, 2026 Testing laboratory .......... : SHENZHEN TONGCE TESTING LAB Testing location/ address: 2101 & 2201, Zhenchang Factory, Renshan Industrial Zone, Fuhai Subdistrict, Bao'an District, Shenzhen, Guangdong, 518103, People's Republic of China Applicant's name ............ : Ergotron Inc. Address ........................... : 1181 Trapp Rd, Saint Paul, Minnesota 55121, United States Manufacturer's name ... : Hetai Electronics (Jiangxi) Co., Ltd. Address ........................... : Building 3, Binjiang Road, Songshan District, Quannan County Industrial Park, Ganzhou City, Jiangxi Province, China Standard(s) ..................... : FCC CFR Title 47 Part 15 Subpart C Section 15.247 FCC KDB 558074 D01 15.247 Meas Guidance v05r02 ANSI C63.10:2020 Product Name ................. : MP100-B Pack Trade Mark ...................... : N/A Model/Type reference..... : MP100-B Rating(s).......................... : Rechargeable Li-ion Battery DC 14.6V Date of receipt of test item ......................................... : Jan. 26, 2026 Date (s) of performance of test ................................... : Jan. 26, 2026 ~ Feb. 03, 2026 Tested by (+signature) ... : Yannie ZHONG Check by (+signature) .... : Beryl ZHAO Approved by (+signature): Tomsin General disclaimer: This report shall not be reproduced except in full, without the written approval of SHENZHEN TONGCE TESTING LAB. This document may be altered or revised by SHENZHEN TONGCE TESTING LAB personnel only, and shall be noted in the revision section of the document. The test results in the report only apply to the tested sample. Report No.: TCT260126E014 Page 2 of 56 Hotline: 400-6611-140 Tel: 86-755-27673339 Fax: 86-755-27673332 http://www.tct-lab.com Table of Contents 1. General Product Information .................................................................. 3 1.1. EUT description ..................................................................................................... 3 1.2. Model(s) list ............................................................................................................ 3 1.3. Operation Frequency ............................................................................................ 3 2. Test Result Summary .............................................................................. 4 3. General Information ................................................................................. 5 3.1. Test environment and mode ................................................................................. 5 3.2. Description of Support Units ................................................................................ 5 4. Facilities and Accreditations .................................................................. 6 4.1. Facilities ................................................................................................................. 6 4.2. Location ................................................................................................................. 6 5. Measurement Uncertainty ....................................................................... 6 6. Test Results and Measurement Data ..................................................... 7 6.1. Antenna requirement ............................................................................................ 7 6.2. Conducted Emission ............................................................................................. 8 6.3. Conducted Output Power ................................................................................... 12 6.4. Emission Bandwidth ........................................................................................... 13 6.5. Power Spectral Density ....................................................................................... 14 6.6. Conducted Band Edge and Spurious Emission Measurement ....................... 15 6.7. Radiated Spurious Emission Measurement ...................................................... 17 Appendix A: Test Result of Conducted Test Appendix B: Photographs of Test Setup Appendix C: Photographs of EUT Report No.: TCT260126E014 Page 3 of 56 Hotline: 400-6611-140 Tel: 86-755-27673339 Fax: 86-755-27673332 http://www.tct-lab.com 1. General Product Information 1.1. EUT description Product Name ....................... : MP100-B Pack Model/Type reference........... : MP100-B Sample Number....................: TCT260126E014-0101 Bluetooth Version ................ : V5.0 Operation Frequency ........... : 2402MHz~2480MHz Channel Separation .............. : 2MHz Data Rate ............................... : LE 1M PHY, LE 2M PHY Number of Channel .............. : 40 Modulation Type ................... : GFSK Antenna Type ........................ : FPC Antenna Antenna Gain ........................ : 2.81dBi Rating(s)................................ : Rechargeable Li-ion Battery DC 14.6V Note: The antenna gain listed in this report is provided by applicant, and the test laboratory is not responsible for this parameter. 1.2. Model(s) list None. 1.3. Operation Frequency Channel Frequency Channel Frequency Channel Frequency Channel Frequency 0 2402MHz 10 2422MHz 20 2442MHz 30 2462MHz 1 2404MHz 11 2424MHz 21 2444MHz 31 2464MHz ... ... ... ... ... ... ... ... 8 2418MHz 18 2438MHz 28 2458MHz 38 2478MHz 9 2420MHz 19 2440MHz 29 2460MHz 39 2480MHz Remark: Channel 0, 19 & 39 have been tested. Report No.: TCT260126E014 Page 4 of 56 Hotline: 400-6611-140 Tel: 86-755-27673339 Fax: 86-755-27673332 http://www.tct-lab.com 2. Test Result Summary Requirement CFR 47 Section Result Antenna requirement §15.203/§15.247 (b)(4) PASS AC Power Line Conducted Emission §15.207 PASS Conducted Peak Output Power §15.247 (b)(3) PASS 6dB Emission Bandwidth §15.247 (a)(…

Text truncated - open the document above for the full version.

Contact Information

Applicant

Cameron Boone
[email protected]Fax: 651-681-7710

Technical Contact

Ergotron Inc.Cameron Boone
[email protected]

1181 Trapp Rd · Saint Paul, Minnesota, 55121 · United States

Test Firm

SHENZHEN TONGCE TESTING LABBeryl Zhao
[email protected]

Technical Specifications

#Rule PartsFrequency RangePower Output
115C2.40 GHz - 2.48 GHz500.00 µW
Confidentiality
Long Term
Grant Notes
Power listed is the maximum conducted output power.