2AVVT-AD00A10057CU-304-0503

Bosch Global Software Technologies Private Limited
CU-304-0503 - FCC ID 2AVVT-AD00A10057 - Bosch Global Software Technologies Private Limited
Click to zoom

Application Details

Equipment Class
DTS - Digital Transmission System
Date of Grant
Jul 23, 2020
Application Purpose
Original Equipment
Date of Application
Jul 23, 2020
Equipment Note
CU-304-0503
Frequency Range
2412.00000000 - 2462.00000000
Company
Bosch Global Software Technologies Private Limited
Country
India

Documents & Files

Select a file to view

Users Manual

↗

Cover Letter(s)

↗
↗
↗

External Photos

↗

ID Label/Location Info

↗

Internal Photos

↗

RF Exposure Info

↗

Test Report

↗
↗

Test Setup Photos

↗

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

Users Manual

CCU Gen2A | Operations Manual 1 | 20 Robert Bosch Engineering and Business Solutions Private Limited | September 19, 2020 CCU User Manual  Product Name: Connectivity Control Unit  Family Model Name: iTraMS CCU  Model Name: CU-304-0503 This preliminary document presents the status of the agreed specifications. It will be confirmed when all the validations has been completed with positive result CCU | User Manual 3 | 20 Robert Bosch Engineering and Business Solutions Private Limited | September 19, 2020 Table of Contents 1 Introduction .............................................................................................................................................................. 6 1.1 Objective ................................................................................................................................................................... 6 1.2 General ...................................................................................................................................................................... 6 1.3 Disclaimer ................................................................................................................................................................. 6 2 Copyright .................................................................................................................................................................. 6 3 Agreed Product Use ................................................................................................................................................. 7 3.1 Intended Use ............................................................................................................................................................. 7 4 Overview ................................................................................................................................................................... 8 5 Symbols Used........................................................................................................................................................... 8 6 Warranty and Service Clauses ................................................................................................................................ 8 7 Safety and Instructions ............................................................................................................................................ 8 7.1 Dos and Don’ts ......................................................................................................................................................... 8 7.2 Precautions for Installation ..................................................................................................................................... 9 8 Scope for Delivery .................................................................................................................................................... 9 9 Legal Requirements ................................................................................................................................................. 9 10 Device Description ................................................................................................................................................. 10 11 Installation .............................................................................................................................................................. 10 11.1 Installation of Cable Harness ................................................................................................................................ 10 12 Technical Specifications ........................................................................................................................................ 11 a. Digital Output.......................................................................................................................................................... 11 b. Bus (CAN0 and CAN1) ........................................................................................................................................... 11 c. Internal Memory ...................................................................................................................................................... 11 d. Power Requirements .............................................................................................................................................. 11 Annexure......................................................................................................................................................................... 12 1 Document Details .................................................................................................................................... 12 2 Document Revision History .................................................................................................................... 12 3 Abbreviations Used ................................................................................................................................. 12 4 EMC Recommendations .......................................................................................................................... 12 5 General Info .............................................................................................................................................. 13 6 Pin-Out details ......................................................................................................................................... 13 CCU | User Manual 4 | 20 Robert Bosch Engineering and Business Solutions Private Limited | September 19, 2020 6.1 Main Connector ......................................................................................................................................... 13 6.2 RF Connector .............................................................................................................…

Text truncated - open the document above for the full version.

Cover Letter(s)

Registered Office: Robert Bosch Engineering and Business Solutions Private Limited, 123, Industrial Layout, Hosur Road, Koramangala, Bengaluru - 560095, India Managing Director: Mr. Dattatri Salagame © Robert Bosch Engineering and Business Solutions Private Limited reserves all rights even in the event of industrial property rights. We reserve all rights of disposal such as copying and passing on to third parties. Robert Bosch Engineering and Business Solutions Private Limited - (CIN: U72400KA1997PTC023164) 123, Industrial Layout, Hosur Road, Koramangala Bengaluru 560095 INDIA Tel +91 80 6657-5757 Fax +91 80 6657-1404 www.bosch-india-software.com 14 July 2020 Declaration of Authorization We Name: Robert Bosch Engineering and Business Solutions Private Limited Address: RBEI/Pac, Ban601, Post Box No 3000 Hosur Road, Audgodi, Bengaluru City: Karnataka Country: India Declare that: Name Representative of agent: Ms. Melody Wu Agent Company name: BTL Inc. Address: 4F,No.18, Ln. 171, Sec. 2, Jiuzong Rd., aaaaaaaxa Neihu Dist.114, City: Taipei Country Taiwan is authorized to apply for Certification of the following product(s): Product description: Connectivity Control Unit - iTraMS Type designation: CU-304-0503 Trademark: Bosch Validity/ expiry date: From 2020/7/10 to 2021/7/9 on our behalf. Date: 2020/7/14 City: Karnataka Name: Subbaramu G Function: Senior General Manager Signature: ______________________ 14 July 2020 Page 2 of 2

Cover Letter(s)

Company Name: Robert Bosch Engineering & Business Solutions Private Limited. Address: RBEI/Pac, Ban 601, Post Box No.3000, Hosur Road, Adugodi City: Bengaluru - 560 030 Country: India To: Telefication B.V., Dept. FCC TCB Edisonstraat 12A 6902 PK ZEVENAAR The Netherlands Subject: Request for confidentiality FCC ID: 2AVVT-AD00A10057 Reference number: Dear FCC TCB, 1. Long-Term Confidentiality Pursuant to 47 CFR Section 0.459(a) & (b), we hereby requests non-disclosure and confidential treatment of the following materials submitted in support of FCC certification application: Bill(s) of Material Block Diagrams Operational Description Schematic Diagrams Tune-up Procedure Above materials contain secrets, proprietary and technical information, which would customarily be guarded from competitors under 47 CFR, section 0.457(d)(2). Disclosure or publication or any portion of this company confidential material to other parties could cause substantial competitive harm and provide unjustified benefits for competitors. 2. Short-Term Confidentiality (STC) Pursuant to Public Notice DA 04-1705 of the Commission’s policy, in order to comply with the marketing regulations in 47 CFR §2.803 and the importation rules in 47 CFR §2.1204, applicant hereby requests Short-Term Confidential treatment of the following materials (See notes below): Internal Photos User’s Manual Test Set-up Photos External Photos Justification: This document contains detailed system and equipment description are considered as proprietary information in operation of the equipment. The public disclosure of above documents might be harmful to our company and would give competitor unfair advantage in the market. Date: 2020-07-13 Name and signature of applicant: Subbaramu G Notes: 1) A document or type of document can only have ONE type of confidentiality! 2) Short-Term confidentiality is in principle for 45 days from date of grant; it can be extended max 3 times (total time 180 days max.)! The planned date should stated in the RF731 application form. 3) FCC must be informed when marketing begins earlier. 4) Release takes place automatically thus extension must be requested in time. Telefication does not remind you of this! 5) Request for extension or for release must be received by Telefication at least 7 days before date of actual marketing or before expiration of the STC period

Cover Letter(s)

Registered Office: Robert Bosch Engineering and Business Solutions Private Limited, 123, Industrial Layout, Hosur Road, Koramangala, Bengaluru - 560095, India Managing Director: Mr. Dattatri Salagame © Robert Bosch Engineering and Business Solutions Private Limited reserves all rights even in the event of industrial property rights. We reserve all rights of disposal such as copying and passing on to third parties. Robert Bosch Engineering and Business Solutions Private Limited - (CIN: U72400KA1997PTC023164) 123, Industrial Layout, Hosur Road, Koramangala Bengaluru 560095 INDIA Tel +91 80 6657-5757 Fax +91 80 6657-1404 www.bosch-india-software.com 14 July 2020 Wi-Fi Channel 12 and 13 Declaration Letter Date: 2020/7/14 We, the undersigned company Company Name: Robert Bosch Engineering and Business Solutions Private Limited Address: RBEI/Pac, Ban601, Post Box No 3000 Hosur Road, Adugodi Bengaluru 560030 India Declare that: Product description: Connectivity Control Unit - iTraMS Type designation: CU-304-0503 Brand: Bosch FCC ID: 2AVVT-AD00A10057 Only channels 1~11 will be used in USA. Country code selection is disabled. If you have any questions regarding the authorization, please do not hesitate to contact us, thank you~ Sincerely, Signature: ________________________ Name: Subbaramu G Tel: +91(80)6136-1692 Email: [email protected] 14 July 2020 Page 2 of 2

External Photos

Appendix No.: EP-2004T194 APPENDIX-EUT PHOTOS Project No.: 2004T194 Page 1 of 19 Appendix No.: EP-2004T194 APPENDIX-EUT PHOTOS Project No.: 2004T194 Page 2 of 19 Appendix No.: EP-2004T194 APPENDIX-EUT PHOTOS Project No.: 2004T194 Page 3 of 19 Appendix No.: EP-2004T194 APPENDIX-EUT PHOTOS Project No.: 2004T194 Page 4 of 19

ID Label/Location Info

1. Label Diagram: 2. Label Location:

Internal Photos

Appendix No.: EP-2004T194 APPENDIX-EUT PHOTOS Project No.: 2004T194 Page 5 of 19 Appendix No.: EP-2004T194 APPENDIX-EUT PHOTOS Project No.: 2004T194 Page 6 of 19 Appendix No.: EP-2004T194 APPENDIX-EUT PHOTOS Project No.: 2004T194 Page 7 of 19 Appendix No.: EP-2004T194 APPENDIX-EUT PHOTOS Project No.: 2004T194 Page 8 of 19 Appendix No.: EP-2004T194 APPENDIX-EUT PHOTOS Project No.: 2004T194 Page 9 of 19 Appendix No.: EP-2004T194 APPENDIX-EUT PHOTOS Project No.: 2004T194 Page 10 of 19 Appendix No.: EP-2004T194 APPENDIX-EUT PHOTOS Project No.: 2004T194 Page 11 of 19 Appendix No.: EP-2004T194 APPENDIX-EUT PHOTOS Project No.: 2004T194 Page 12 of 19 Appendix No.: EP-2004T194 APPENDIX-EUT PHOTOS Project No.: 2004T194 Page 13 of 19 Appendix No.: EP-2004T194 APPENDIX-EUT PHOTOS Project No.: 2004T194 Page 14 of 19 Appendix No.: EP-2004T194 APPENDIX-EUT PHOTOS Project No.: 2004T194 Page 15 of 19 Appendix No.: EP-2004T194 APPENDIX-EUT PHOTOS Project No.: 2004T194 Page 16 of 19 Appendix No.: EP-2004T194 APPENDIX-EUT PHOTOS Project No.: 2004T194 Page 17 of 19 Appendix No.: EP-2004T194 APPENDIX-EUT PHOTOS Project No.: 2004T194 Page 18 of 19 Appendix No.: EP-2004T194 APPENDIX-EUT PHOTOS Project No.: 2004T194 Page 19 of 19

RF Exposure Info

Report No.: BTL-FCCP-9-2004T194 Project No.: 2004T194 Page 1 of 6 Report Version: R02 FCC RF EXPOSURE REPORT FCC ID: 2AVVT-AD00A10057 Report No. : BTL-FCCP-9-2004T194 Equipment : Connectivity Control Unit - iTraMS Model Name : AD00A10057, CU-304-0503 Brand Name : Bosch Applicant : Robert Bosch Engineering and Business Solutions Private Limited Address : RBEI/Pac, Ban601, Post Box No 3000 Hosur Road, Adugodi Bengaluru 560030 India (Republic Of) Radio Function : Bluetooth EDR/ Bluetooth LE/WLAN 2.4G/RLAN 5G/WCDMA/LTE FCC Rule Part(s) : FCC Guidelines for Human Exposure IEEE C95.1 & FCC Part 2.1091 FCC Title 47 Part 2.1091, OET Bulletin 65 Supplement C Date of Receipt : 2020/5/13 Date of Test : 2020/5/13 ~ 2020/7/9 Issued Date : 2020/7/22 The above equipment has been tested and found in compliance with the requirement of the above standards by BTL Inc. Prepared by : Peter Chen, Engineer Approved by : Scott Hsu , Manager BTL Inc. No.18, Ln. 171, Sec. 2, Jiuzong Rd., Neihu Dist., Taipei City 114, Taiwan Tel: +886-2-2657-3299 Fax: +886-2-2657-3331 Web: www.newbtl.com Report No.: BTL-FCCP-9-2004T194 Project No.: 2004T194 Page 2 of 6 Report Version: R02 REPORT ISSUED HISTORY Report Version Description Issued Date R00 Original Issue 2020/7/22 Report No.: BTL-FCCP-9-2004T194 Project No.: 2004T194 Page 3 of 6 Report Version: R02 1. MPE CALCULATION METHOD Calculation Method of RF Safety Distance: where: S = power density P = power input to the antenna G = power gain of the antenna in the direction of interest relative to an isotropic radiator R = distance to the center of radiation of the antenna Table for Filed Antenna: For BT/LE/2.4GHz: Ant. Brand Part number Antenna Type Connector Gain (dBi) CH0 146153 Dipole (Internal) Compatible I-PEX MHF I & MMCX-JW 3.0 For 5GHz: Ant. Brand Part number Antenna Type Connector Gain (dBi) CH0 146153 Dipole (Internal) Compatible I-PEX MHF I & MMCX-JW 4.1 For WCDMA: Brand S/N Antenna Type Connector Gain (dBi) Note N/A Internal Integrated (Through Hole) 5.2 Band II N/A Internal Integrated (Through Hole) 0 Band V For LTE: Brand S/N Antenna Type Connector Gain (dBi) Note N/A Internal Integrated (Through Hole) 5.2 Band 2 N/A Internal Integrated (Through Hole) 5.2 Band 4 N/A Internal Integrated (Through Hole) 0 Band 5 N/A Internal Integrated (Through Hole) -3.3 Band 12 Band Max. gain for FCC MPE Limits Max. gain for Industry Canada MPE Limits Maximum gain to be compliant with all Limits WCDMA Band II 12.5 9.1 9.1 WCDMA Band V 10.0 6.7 6.7 LTE Band 2 12.5 9.6 9.6 LTE Band 4 13.0 9.3 9.3 LTE Band 5 10.4 7.1 7.1 LTE Band 12 9.8 6.7 6.7 Report No.: BTL-FCCP-9-2004T194 Project No.: 2004T194 Page 4 of 6 Report Version: R02 Output power including tune up tolerance Function Target power (dBm) Tolerance (dB) Maximum power (dBm) BT 1 ±1 2 BLE 11 ±1 12 WLAN 2.4G 17 ±1 18 RLAN 5GHz UNII-1 18 ±1 19 RLAN 5GHz UNII-2A 18 ±1 19 RLAN 5GHz UNII-2C 17 ±1 18 RLAN 5GHz UNII-3 14 ±1 15 WCDMA 23 ±2 25 LTE 22 ±2 24 Report No.: BTL-FCCP-9-2004T194 Project No.: 2004T194 Page 5 of 6 Report Version: R02 2. TEST RESULTS For BT: Antenna Gain (dBi) Antenna Gain (numeric) Max. Output Power (dBm) Peak Output Power ( mW ) Power Density (mW/cm2) Limit of Power Density (mW/cm2) Test Result 3.00 1.9953 2 1.5849 0.00062943 1 Complies For LE: Antenna Gain (dBi) Antenna Gain (numeric) Max. Output Power (dBm) Peak Output Power ( mW ) Power Density (mW/cm2) Limit of Power Density (mW/cm2) Test Result 3.00 1.9953 12 15.8489 0.00629434 1 Complies For 2.4GHz: Antenna Gain (dBi) Antenna Gain (numeric) Max. Output Power (dBm) Peak Output Power ( mW ) Power Density (mW/cm2) Limit of Power Density (mW/cm2) Test Result 3.00 1.9953 18 63.0957 0.02505823 1 Complies For 5GHz UNII-1: Antenna Gain (dBi) Antenna Gain (numeric) Max. Output Power (dBm) Peak Output Power ( mW ) Power Density (mW/cm2) Limit of Power Density (mW/cm2) Test Result 4.10 2.5704 19 79.4328 0.04063969 1 Complies For 5GHz UNII-2A: Antenna Gain (dBi) Antenna Gain (numeric) Max. Output Power (dBm) Peak Output Power ( mW ) Power Density (mW/cm2) Limit of Power Density (mW/cm2) Test Result 4.10 2.5704 19 79.4328 0.04063969 1 Complies For 5GHz UNII-2C: Antenna Gain (dBi) Antenna Gain (numeric) Max. Output Power (dBm) Peak Output Power ( mW ) Power Density (mW/cm2) Limit of Power Density (mW/cm2) Test Result 4.10 2.5704 18 63.0957 0.03228125 1 Complies For 5GHz UNII-3: Antenna Gain (dBi) Antenna Gain (numeric) Max. Output Power (dBm) Peak Output Power ( mW ) Power Density (mW/cm2) Limit of Power Density (mW/cm2) Test Result 4.10 2.5704 15 31.6228 0.01617895 1 Complies Report No.: BTL-FCCP-9-2004T194 Project No.: 2004T194 Page 6 of 6 Report Version: R02 For WWAN: Mode Band Frequency (MHz) Antenna Gain (dBi) Max. Output Power (dBm) Power Density (mW/cm 2 ) Limit of Power Density (mW/cm 2 ) Test Result WCDMA Band II 1907.6 5.2 25 0.2083 1.0000 Complies WCDMA Band V 826.4 0 25 0.0629 0.5509 Complies LTE Band 2 1860.0 5.2 24 0.1655 1.0000 Complies LTE Band 4 1732.5 5.2 24 0.1655 1.0000 Complies LTE Band 5 836.5 0 24 0.0500 0.5577 Complies LTE Band 12 704.0 -3.3 24 0.0234 0.4693 Complies For the max simultaneous transmission MPE: Maximum Bluetooth Power Density (mW/cm2) Maximum WLAN Power Density (mW/cm2) Maximum WWAN Power Density (mW/cm2) 0.0063 0.0406 0.2083 Simultaneous transmission of Bluetooth+WWAN 0.2146<1 Simultaneous transmission of WIFI+WWAN 0.2489<1 Note: The calculated distance is 20 cm. End of Test Report

Test Report

Report No.: BTL-FCCP-5-2004T194 Project No.: 2004T194 Page 1 of 41 Report Version: R00 FCC Radio Test Report FCC ID: 2AVVT-AD00A10057 Report No. : BTL-FCCP-5-2004T194 Equipment : Connectivity Control Unit - iTraMS Model Name : AD00A10057, CU-304-0503 Brand Name : Bosch Applicant : Robert Bosch Engineering and Business Solutions Private Limited Address : RBEI/Pac, Ban601, Post Box No 3000 Hosur Road, Adugodi Bengaluru 560030 India (Republic Of) Radio Function : Bluetooth Low Energy FCC Rule Part(s) : FCC Part15, Subpart C (15.247) Measurement Procedure(s) : ANSI C63.10-2013 Date of Receipt : 2020/5/13 Date of Test : 2020/5/13 ~ 2020/6/23 Issued Date : 2020/7/22 The above equipment has been tested and found in compliance with the requirement of the above standards by BTL Inc. Prepared by : Peter Chen, Engineer Approved by : Scott Hsu , Manager BTL Inc. No.18, Ln. 171, Sec. 2, Jiuzong Rd., Neihu Dist., Taipei City 114, Taiwan Tel: +886-2-2657-3299 Fax: +886-2-2657-3331 Web: www.newbtl.com Report No.: BTL-FCCP-5-2004T194 Project No.: 2004T194 Page 2 of 41 Report Version: R00 Declaration BTL represents to the client that testing is done in accordance with standard procedures as applicable and that test instruments used has been calibrated with standards traceable to international standard(s) and/or national standard(s). BTL's reports apply only to the specific samples tested under conditions. It is manufacture’s responsibility to ensure that additional production units of this model are manufactured with the identical electrical and mechanical components. BTL shall have no liability for any declarations, inferences or generalizations drawn by the client or others from BTL issued reports. The report must not be used by the client to claim product certification, approval, or endorsement by NIST, A2LA, or any agency of the U.S. Government. This report is the confidential property of the client. As a mutual protection to the clients, the public and ourselves, the test report shall not be reproduced, except in full, without our written approval. BTL’s laboratory quality assurance procedures are in compliance with the ISO/IEC 17025 requirements, and accredited by the conformity assessment authorities listed in this test report. BTL is not responsible for the sampling stage, so the results only apply to the sample as received. The information, data and test plan are provided by manufacturer which may affect the validity of results, so it is manufacturer’s responsibility to ensure that the apparatus meets the essential requirements of applied standards and in all the possible configurations as representative of its intended use. Limitation For the use of the authority's logo is limited unless the Test Standard(s)/Scope(s)/Item(s) mentioned in this test report is (are) included in the conformity assessment authorities acceptance respective. Please note that the measurement uncertainty is provided for informational purpose only and are not use in determining the Pass/Fail results. Report No.: BTL-FCCP-5-2004T194 Project No.: 2004T194 Page 3 of 41 Report Version: R00 CONTENTS REPORT ISSUED HISTORY 5 1 SUMMARY OF TEST RESULTS 6 1.1 TEST FACILITY 7 1.2 MEASUREMENT UNCERTAINTY 7 1.3 TEST ENVIRONMENT CONDITIONS 8 1.4 TABLE OF PARAMETERS OF TEXT SOFTWARE SETTING 8 1.5 DUTY CYCLE 8 2 GENERAL INFORMATION 9 2.1 DESCRIPTION OF EUT 9 2.2 TEST MODES 10 2.3 BLOCK DIAGRAM SHOWING THE CONFIGURATION OF SYSTEM TESTED 11 2.4 SUPPORT UNITS 11 3 RADIATED EMISSIONS TEST 12 3.1 LIMIT 12 3.2 TEST PROCEDURE 13 3.3 DEVIATION FROM TEST STANDARD 13 3.4 TEST SETUP 14 3.5 EUT OPERATING CONDITIONS 15 3.6 TEST RESULT – 30 MHZ TO 1 GHZ 15 3.7 TEST RESULT – ABOVE 1 GHZ 15 4 BANDWIDTH TEST 16 4.1 APPLIED PROCEDURES / LIMIT 16 4.2 TEST PROCEDURE 16 4.3 DEVIATION FROM STANDARD 16 4.4 TEST SETUP 16 4.5 EUT OPERATION CONDITIONS 16 4.6 TEST RESULTS 16 5 OUTPUT POWER TEST 17 5.1 APPLIED PROCEDURES / LIMIT 17 5.2 TEST PROCEDURE 17 5.3 DEVIATION FROM STANDARD 17 5.4 TEST SETUP 17 5.5 EUT OPERATION CONDITIONS 17 5.6 TEST RESULTS 17 6 POWER SPECTRAL DENSITY TEST 18 6.1 APPLIED PROCEDURES / LIMIT 18 6.2 TEST PROCEDURE 18 6.3 DEVIATION FROM STANDARD 18 6.4 TEST SETUP 18 6.5 EUT OPERATION CONDITIONS 18 6.6 TEST RESULTS 18 7 ANTENNA CONDUCTED SPURIOUS EMISSION 19 7.1 APPLIED PROCEDURES / LIMIT 19 7.2 TEST PROCEDURE 19 7.3 DEVIATION FROM STANDARD 19 7.4 TEST SETUP 19 7.5 EUT OPERATION CONDITIONS 19 Report No.: BTL-FCCP-5-2004T194 Project No.: 2004T194 Page 4 of 41 Report Version: R00 7.6 TEST RESULTS 19 8 LIST OF MEASURING EQUIPMENTS 20 9 EUT TEST PHOTO 21 10 EUT PHOTOS 21 APPENDIX A RADIATED EMISSIONS - 30 MHZ TO 1 GHZ 22 APPENDIX B RADIATED EMISSIONS - ABOVE 1 GHZ 25 APPENDIX C BANDWIDTH 34 APPENDIX D OUTPUT POWER 36 APPENDIX E POWER SPECTRAL DENSITY TEST 38 APPENDIX F ANTENNA CONDUCTED SPURIOUS EMISSION 40 Report No.: BTL-FCCP-5-2004T194 Project No.: 2004T194 Page 5 of 41 Report Version: R00 REPORT ISSUED HISTORY Report Version Description Issued Date R00 Original Issue. 2020/7/22 Report No.: BTL-FCCP-5-2004T194 Project No.: 2004T194 Page 6 of 41 Report Version: R00 1 SUMMARY OF TEST RESULTS Test procedures according to the technical standards. FCC Part 15, Subpart C (15.247) Standard(s) Section Description Test Result Judgement Remark 15.207 AC Power Line Conducted Emissions ------ N/A NOTE(1) 15.205 15.209 15.247(d) Radiated Emissions APPENDIX A APPENDIX B Pass ------ 15.247(a)(2) Bandwidth APPENDIX C Pass ------ 15.247(b)(3) Output Power APPENDIX D Pass ------ 15.247(e) Power Spectral Density APPENDIX E Pass ------ 15.247(d) Antenna conducted Spurious Emission APPENDIX F Pass ------ 15.203 Antenna Requirement ------ Pass ------ NOTE: (1) ”N/A” denotes test is not applicable in this Test Report. (2) The report format version is TP.1.1.1. Report No.: BTL-FCCP-5-2004T194 Project No.: 2004T194 Page 7 of 41 Report Version: R00 1.1 TEST FACILITY The test facilities used to collect the test data in this report: No. 68-1, Ln. 169, Sec. 2, Datong Rd., X…

Text truncated - open the document above for the full version.

Test Report

Report No.: BTL-FCCP-6-2004T194 Project No.: 2004T194 Page 1 of 75 Report Version: R00 FCC Radio Test Report FCC ID: 2AVVT-AD00A10057 Report No. : BTL-FCCP-6-2004T194 Equipment : Connectivity Control Unit - iTraMS Model Name : AD00A10057, CU-304-0503 Brand Name : Bosch Applicant : Robert Bosch Engineering and Business Solutions Private Limited Address : RBEI/Pac, Ban601, Post Box No 3000 Hosur Road, Adugodi Bengaluru 560030 India (Republic Of) Radio Function : WLAN 2.4 GHz FCC Rule Part(s) : FCC Part15, Subpart C (15.247) Measurement Procedure(s) : ANSI C63.10-2013 Date of Receipt : 2020/5/13 Date of Test : 2020/5/13 ~ 2020/7/16 Issued Date : 2020/7/22 The above equipment has been tested and found in compliance with the requirement of the above standards by BTL Inc. Prepared by : Peter Chen, Engineer Approved by : Scott Hsu , Manager BTL Inc. No.18, Ln. 171, Sec. 2, Jiuzong Rd., Neihu Dist., Taipei City 114, Taiwan Tel: +886-2-2657-3299 Fax: +886-2-2657-3331 Web: www.newbtl.com Report No.: BTL-FCCP-6-2004T194 Project No.: 2004T194 Page 2 of 75 Report Version: R00 Declaration BTL represents to the client that testing is done in accordance with standard procedures as applicable and that test instruments used has been calibrated with standards traceable to international standard(s) and/or national standard(s). BTL's reports apply only to the specific samples tested under conditions. It is manufacture’s responsibility to ensure that additional production units of this model are manufactured with the identical electrical and mechanical components. BTL shall have no liability for any declarations, inferences or generalizations drawn by the client or others from BTL issued reports. The report must not be used by the client to claim product certification, approval, or endorsement by NIST, A2LA, or any agency of the U.S. Government. This report is the confidential property of the client. As a mutual protection to the clients, the public and ourselves, the test report shall not be reproduced, except in full, without our written approval. BTL’s laboratory quality assurance procedures are in compliance with the ISO/IEC 17025 requirements, and accredited by the conformity assessment authorities listed in this test report. BTL is not responsible for the sampling stage, so the results only apply to the sample as received. The information, data and test plan are provided by manufacturer which may affect the validity of results, so it is manufacturer’s responsibility to ensure that the apparatus meets the essential requirements of applied standards and in all the possible configurations as representative of its intended use. Limitation For the use of the authority's logo is limited unless the Test Standard(s)/Scope(s)/Item(s) mentioned in this test report is (are) included in the conformity assessment authorities acceptance respective. Please note that the measurement uncertainty is provided for informational purpose only and are not use in determining the Pass/Fail results. Report No.: BTL-FCCP-6-2004T194 Project No.: 2004T194 Page 3 of 75 Report Version: R00 CONTENTS REPORT ISSUED HISTORY 5 1 SUMMARY OF TEST RESULTS 6 1.1 TEST FACILITY 7 1.2 MEASUREMENT UNCERTAINTY 7 1.3 TEST ENVIRONMENT CONDITIONS 7 1.4 TABLE OF PARAMETERS OF TEXT SOFTWARE SETTING 8 1.5 DUTY CYCLE 9 2 GENERAL INFORMATION 10 2.1 DESCRIPTION OF EUT 10 2.2 TEST MODES 11 2.3 BLOCK DIAGRAM SHOWING THE CONFIGURATION OF SYSTEM TESTED 12 2.4 SUPPORT UNITS 12 3 RADIATED EMISSIONS TEST 13 3.1 LIMIT 13 3.2 TEST PROCEDURE 14 3.3 DEVIATION FROM TEST STANDARD 14 3.4 TEST SETUP 14 3.5 EUT OPERATING CONDITIONS 15 3.6 TEST RESULT – 30 MHZ TO 1 GHZ 16 3.7 TEST RESULT – ABOVE 1 GHZ 16 4 BANDWIDTH TEST 17 4.1 LIMIT 17 4.2 TEST PROCEDURE 17 4.3 DEVIATION FROM TEST STANDARD 17 4.4 TEST SETUP 17 4.5 EUT OPERATING CONDITIONS 17 4.6 TEST RESULT 17 5 OUTPUT POWER TEST 18 5.1 LIMIT 18 5.2 TEST PROCEDURE 18 5.3 DEVIATION FROM TEST STANDARD 18 5.4 TEST SETUP 18 5.5 EUT OPERATING CONDITIONS 18 5.6 TEST RESULT 18 6 POWER SPECTRAL DENSITY 19 6.1 LIMIT 19 6.2 TEST PROCEDURE 19 6.3 DEVIATION FROM TEST STANDARD 19 6.4 TEST SETUP 19 6.5 EUT OPERATING CONDITIONS 19 6.6 TEST RESULT 19 7 ANTENNA CONDUCTED SPURIOUS EMISSIONS TEST 20 7.1 LIMIT 20 7.2 TEST PROCEDURE 20 7.3 DEVIATION FROM TEST STANDARD 20 7.4 TEST SETUP 20 7.5 EUT OPERATING CONDITIONS 20 7.6 TEST RESULT 20 Report No.: BTL-FCCP-6-2004T194 Project No.: 2004T194 Page 4 of 75 Report Version: R00 8 LIST OF MEASURING EQUIPMENTS 21 9 EUT TEST PHOTO 22 10 EUT PHOTOS 22 APPENDIX A RADIATED EMISSIONS - 30 MHZ TO 1 GHZ 23 APPENDIX B RADIATED EMISSIONS - ABOVE 1 GHZ 26 APPENDIX C BANDWIDTH 59 APPENDIX D OUTPUT POWER 64 APPENDIX E POWER SPECTRAL DENSITY 66 APPENDIX F ANTENNA CONDUCTED SPURIOUS EMISSIONS 71 Report No.: BTL-FCCP-6-2004T194 Project No.: 2004T194 Page 5 of 75 Report Version: R00 REPORT ISSUED HISTORY Report Version Description Issued Date R00 Original Issue. 2020/7/22 Report No.: BTL-FCCP-6-2004T194 Project No.: 2004T194 Page 6 of 75 Report Version: R00 1 SUMMARY OF TEST RESULTS Test procedures according to the technical standards. FCC Part 15, Subpart C (15.247) Standard(s) Section Description Test Result Judgement Remark 15.207 AC Power Line Conducted Emissions ------ N/A NOTE(1) 15.205 15.209 15.247(d) Radiated Emissions APPENDIX A APPENDIX B Pass ------ 15.247(a) Bandwidth APPENDIX C Pass ------ 15.247(b) Output Power APPENDIX D Pass ------ 15.247(e) Power Spectral Density APPENDIX E Pass ------ 15.247(d) Antenna conducted Spurious Emission APPENDIX F Pass ------ 15.203 Antenna Requirement ------ Pass ------ NOTE: (1) ”N/A” denotes test is not applicable in this Test Report. (2) The report format version is TP.1.1.1. Report No.: BTL-FCCP-6-2004T194 Project No.: 2004T194 Page 7 of 75 Report…

Text truncated - open the document above for the full version.

Contact Information

Applicant

Rajeev Kumar B R(General Manager)
[email protected]+91(80)68903246Fax: +91(80)4176-8951

Technical Contact

BTL Inc.Scott Hsu
[email protected]886-2-2641-8198

4F,No.18,Ln. 171, Sec. 2, Jiuzong Rd., Neihu Dist. · Taipei · Taiwan

Non-Technical Contact

BTL Inc.Melody Wu
[email protected]886-2-2641-8198

Test Firm

BTL Inc.Jackie Chiu
[email protected]+886-2-2641-8198Fax: +886-2-2641-8698

Technical Specifications

#Rule PartsFrequency RangePower Output
215C2.41 GHz - 2.46 GHz362.00 mW
Confidentiality
Long Term
Grant Notes
Output power listed is conducted. The antenna(s) used for this transmitter must be used to provide a separation distance of at least 20 cm from all persons and must not be co-located or operating in conjunction with any other antenna or transmitter. End-users must be provided with antenna operating conditions for satisfying RF exposure compliance. This device has 20/40 MHz bandwidth modes.