75F, Inc.

Application Details

Equipment Class
DTS - Digital Transmission System
Date of Grant
Dec 14, 2025
Application Purpose
Original Equipment
Equipment Note
MyStat
Frequency Range
906.00000000 - 924.00000000
Company
75F, Inc.
Country
United States

Documents & Files

Select a file to view

Attestation Statements

↗
↗
↗

Cover Letter(s)

↗
↗
↗

ID Label/Location Info

↗

RF Exposure Info

↗

Test Report

↗
↗
↗
↗

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

RF Exposure Info

Prüfbericht – Produkte Test Report - Products Prüfbericht-Nr.: Test report no.: IN25KPWW 001 / IN25SCW8 001 Auftrags-Nr.: Order no.: 147104915 10 Seite 1 von 6 Page 1 of 6 Kunden-Referenz-Nr.: Client reference no.: 2566340 Auftragsdatum: Order date: 2025-09-09 Auftraggeber: Client: 75F Inc. , 1650 W, 82nd St, #200, Bloomington, Minnesota, USA - 55431 Prüfgegenstand: Test item: MyStat Bezeichnung / Typ-Nr.: Identification / Type no.: Main Model: 7X-TS-C4K-C2 Associated Model: 7X-TS-C4K-X; 7C-TS-C4K-C2; 7C-TS-C4K-X; Auftrags-Inhalt: Order content: Testing and issue of Test Report with Grant Certificate Prüfgrundlage: Test specification: FCC Part1 1.1310, KDB 447498 D01 RSS 102 Issue 6 Wareneingangsdatum: Date of sample receipt: 2025-09-10 Prüfmuster-Nr.: Test sample no: A004088908-001 A004088908-002 Prüfzeitraum: Testing period: 2025-09-15 - 2025-10-13 Ort der Prüfung: Place of testing: Wireless laboratory, Bangalore Prüflaboratorium: Testing laboratory: TÜV Rheinland (India) Pvt.Ltd., 27/B, 2nd Cross, Electronic City Phase1 Bangalore -560 100, India FCC Test site registration number: 496599 ISED Test site registration number: 27711 Prüfergebnis*: Test result*: Pass geprüft von: tested by: X Signed by: Naveen Kumar Muthyalapati Venkata genehmigt von: authorized by: X Signed by: Madhu Nagaraju Datum: Date: 2025-11-07 Ausstellungsdatum: Issue date: 2025-11-07 Stellung / Position: Senior Engineer Stellung / Position: Assistant Manager Sonstiges / Other: FCC ID: 2AVZO-101644 IC: 25972-101644 Zustand des Prüfgegenstandes bei Anlieferung: Condition of the test item at delivery: Prüfmuster vollständig und unbeschädigt Test item complete and undamaged * Legende: P(ass) = entspricht o.g. Prüfgrundlage(n) F(ail) = entspricht nicht o.g. Prüfgrundlage(n) N/A = nicht anwendbar N/T = nicht getestet * Legend: P(ass) = passed a.m. test specification(s) F(ail) = failed a.m. test specification(s) N/A = not applicable N/T = not tested Dieser Prüfbericht bezieht sich nur auf das o.g. Prüfmuster und darf ohne Genehmigung der Prüfstelle nicht auszugsweise vervielfältigt werden. Dieser Bericht berechtigt nicht zur Verwendung eines Prüfzeichens. This test report only relates to the above mentioned test sample. Without permission of the test center this test report is not permitted to be duplicated in extracts. This test report does not entitle to carry any test mark. TÜV Rheinland (India) Pvt. Ltd. # 27/B, 2nd Cross Road, Electronics City Phase 1, Bangalore – 560 100, INDIA. Mail: [email protected] ∙ Web: www.ind.tuv.com V101023IMEASR Produkte Products www.tuv.com Prüfbericht - Nr.: Test Report No.: IN25KPWW 001 / IN25SCW8 001 Seite 2 von 6 Page 2 of 6 1 Alle eingesetzten Prüfmittel waren zum angegebenen Prüfzeitraum gemäß eines festgelegten Kalibrierungsprogramms unseres Prüfhauses kalibriert. Sie entsprechen den in den Prüfprogrammen hinterlegten Anforderungen. Die Rückverfolgbarkeit der eingesetzten Prüfmittel ist durch die Einhaltung der Regelungen unseres Managementsystems gegeben. Detaillierte Informationen bezüglich Prüfkonditionen, Prüfequipment und Messunsicherheiten sind im Prüflabor vorhanden und können auf Wunsch bereitgestellt werden. The equipment used during the specified testing period was calibrated according to our test laboratory calibration program. The equipment fulfils the requirements included in the relevant standards. The traceability of the test equipment used is ensured by compliance with the regulations of our management system. Detailed information regarding test conditions, equipment and measurement uncertainty is available in the test laboratory and could be provided on request. 2 Wie vertraglich vereinbart, wurde dieses Dokument nur digital unterzeichnet. Der TÜV Rheinland hat nicht überprüft, welche rechtlichen oder sonstigen diesbezüglichen Anforderungen für dieses Dokument gelten. Diese Überprüfung liegt in der Verantwortung des Benutzers dieses Dokuments. Auf Verlangen des Kunden kann der TÜV Rheinland die Gültigkeit der digitalen Signatur durch ein gesondertes Dokument bestätigen. Diese Anfrage ist an unseren Vertrieb zu richten. Eine Umweltgebühr für einen solchen zusätzlichen Service wird erhoben. Informationen zur Verifizierung der Authentizität unserer Dokumente erhalten Sie auf folgender Webseite: go.tuv.com/digital-signature As contractually agreed, this document has been signed digitally only. TUV Rheinland has not verified and unable to verify which legal or other pertaining requirements are applicable for this document. Such verification is within the responsibility of the user of this document. Upon request by its client, TUV Rheinland can confirm the validity of the digital signature by a separate document. Such request shall be addressed to our Sales department. An environmental fee for such additional service will be charged. For information on verifying the authenticity of our documents, please visit the following website: go.tuv.com/digital-signature 3 Prüfklausel mit der Note * wurden an qualifizierte Unterauftragnehmer vergeben und sind unter der jeweiligen Prüfklausel des Berichts beschrieben. Abweichungen von Prüfspezifikation(en) oder Kundenanforderungen sind in der jeweiligen Prüfklausel im Bericht aufgeführt. Test clauses with remark of * are subcontracted to qualified subcontractors and descripted under the respective test clause in the report. Deviations of testing specification(s) or customer requirements are listed in specific test clause in the report. 4 Die Entscheidungsregel für Konformitätserklärungen basierend auf numerischen Messergebnisen in diesem Prüfbericht basiert auf der "Null-Grenzwert-Regel" und der "Einfachen Akzeptanz" gemäß ILAC G8:2019 und IEC Guide 115:2023, es sei denn, in der auf Seite 1 dieses Berichts genannten angewandten Norm ist etwas anderes festgelegt oder vom Kunden gewünscht. Dies bedeutet, dass die Messunsicherheit nicht berücksichtigt wird und daher auch nicht im Prüfbericht angegeben wird. Zu weiteren Informationen bezü…

Text truncated - open the document above for the full version.

Test Report

2450AT18D0100001E Legacy P/N: 2450AT18D0100 Page 1 of 5 / Revision 5.0 Datasheet 2450AT18D0100001E johansontechnology.com 4001 Calle Tecate • Camarillo, CA 93012, USA • TEL +1.805.389.1166 2023 Johanson Technology, Inc. All Rights Reserved 2.4GHz, EIA 1206, Bluetooth/WiFi/Zigbee Johanson Technology, Inc. (JTI) miniature RF ceramic chip antennas are made using Low Temperature Co-fired Ceramic (LTCC) technology which has the ability to embed low and high dielectric constants inside our antenna. This enables our components to have high detuning resilience and stability over extreme temperatures (~2ppm). General Specifications 1 2 Maximum Ratings 1 Typical value represents average measurement at 25°C. Min./Max. values represent measurements from -40°C to +85°C 2 General specifications measured on Johanson’s evaluation board PN 2450AT18D0100001CE1 Passband Frequency (MHz) 2400 - 2480 Peak Gain (dBi) 1.5 Average Gain (dBi) -1.0 Radiated Efficiency 72% Return Loss (dB) 10 min. Impedance (Ω) 50 Power Capacity (W) 2 max. (CW) Operating Temperature -40 to +125°C Recommended Storage Conditions post-installation (°C) -40 to +85 Recommended Storage Conditions and Period for Unused T&R Product 45% - 75% RH +5 to +35 °C 18 Months Max. Center-edge Circular Recommended mounting locations for this antenna 2450AT18D0100001E Legacy P/N: 2450AT18D0100 Page 2 of 5 / Revision 5.0 Datasheet 2450AT18D0100001E johansontechnology.com 4001 Calle Tecate • Camarillo, CA 93012, USA • TEL +1.805.389.1166 2023 Johanson Technology, Inc. All Rights Reserved Mechanical Dimensions Terminal Configuration (Alternate) Pin Number Function Function Pin1 FEED GND Pin2 GND GND Pin3 GND GND Pin4 GND FEED L W a b Top view Side view b T Bottom view 4 3 2 Pin2 GND 1 Pin1 FEED Pin4 GND Pin3 GND (Can be swapped) L0.126±0.0083.20±0.2 W0.063±0.0081.60±0.2 T0.047±0.0041.20±0.1 a0.0120.30 b0.020±0.0080.50±0.2 +0.1 / -0.2+0.004 / -0.008 I nchesMillimeters 2450AT18D0100001E Legacy P/N: 2450AT18D0100 Page 3 of 5 / Revision 5.0 Datasheet 2450AT18D0100001E johansontechnology.com 4001 Calle Tecate • Camarillo, CA 93012, USA • TEL +1.805.389.1166 2023 Johanson Technology, Inc. All Rights Reserved Evaluation Board and Mounting Configuration (PN 2450AT18D0100001CE1) 1.0 2.0 1.0 0.6 0.7 0.6 4.1 4.0 0 Ohm Antenna Matching Network Avoid GND on all layers Ground Plane 6.0 Land Solder Resist 50Ω GCPW GND Vias GND Clearance If you’d like the CAD PCB layout or have any questions, contact our application engineers at https://www.johansontechnology.com/ask-a-question Units in mm Ground Vias Feed 40 20 Antenna Matching Network Radiated efficiency is 72% Units in mm 2450AT18D0100001E Legacy P/N: 2450AT18D0100 Page 4 of 5 / Revision 5.0 Datasheet 2450AT18D0100001E johansontechnology.com 4001 Calle Tecate • Camarillo, CA 93012, USA • TEL +1.805.389.1166 2023 Johanson Technology, Inc. All Rights Reserved Evaluation Board Return Loss Measurement Evaluation Board 2D Radiation Patterns If you would like to connect with a Johanson Technology RF engineer to go over the layout or suggest an antenna to go with your design, see our Ask-a-question page. 2.22.42.62.82.03.0 -20 -10 -30 0 f req, GHz dB(S(1,1)) m1 m2 m3 m1 f req= dB(S(1,1))=-13.935 2.400GHz m2 f req= dB(S(1,1))=-14.774 2.500GHz m3 f req= dB(S(1,1))=-24.894 2.450GHz +Z -Z +Y -Y +Z -Z +X -X θ +Z (θ = 0°) +Y (θ = 90°) -Y -Z θ +Z (θ = 0°) +X (θ = 90°) -X -Z φ +X (φ = 0°) -X +Y (φ = 90°) -Y +X -X +Y -Y 2450AT18D0100001E Legacy P/N: 2450AT18D0100 Page 5 of 5 / Revision 5.0 Datasheet 2450AT18D0100001E johansontechnology.com 4001 Calle Tecate • Camarillo, CA 93012, USA • TEL +1.805.389.1166 2023 Johanson Technology, Inc. All Rights Reserved Orderable Part Number Important Links 2450AT18D0100001E Downloads More Antennas Antenna Tuning, Optimization, and Validation Services Soldering Information MSL Information Packaging Information RoHS Compliance Contact our application engineers for a PCB layout review! Part Number Explanation Packaging Style Bulk (loose pcs.) P/N. 2450AT18D0100001B T & R (7" Reel Embossed Tape) P/N. 2450AT18D0100001E (Qty: 1,000 pcs./reel) Evaluation Board Assembled PCB (50Ω SMA) P/N. 2450AT18D0100001CE1

Test Report

APPLICATION SPECIFICATION REVISION: ECR/ECN INFORMATION: TITLE: 868/915MHz Flexible Antenna Application Specification SHEET No. A EC No: 608264 1 of 20 DATE: 2018/12/03 DOCUMENT NUMBER: CREATED / REVISED BY: CHECKED BY: APPROVED BY: AS-2111400100 Liu Hai 2018/11/29 Cheng Kang 2018/11/29 Chris Zhong 2018/11/29 TEMPLATE FILENAME: APPLICATION_SPEC[SIZE_A](V.1).DOC 868/915MHZ FLEXIBLE ANTENNA TABLE OF CONTENTS 1.0 SCOPE 2.0 PRODUCT DESCRIPTION 3.0 APPLICABLE DOCUMENTS 4.0 ANTENNA PERFORMANCE 5.0 ASSEMBLY GUIDELINE 6.0 RF PERFORMANCE AS A FUNCTION OF IMPLEMENTATION APPLICATION SPECIFICATION REVISION: ECR/ECN INFORMATION: TITLE: 868/915MHz Flexible Antenna Application Specification SHEET No. A EC No: 608264 2 of 20 DATE: 2018/12/03 DOCUMENT NUMBER: CREATED / REVISED BY: CHECKED BY: APPROVED BY: AS-2111400100 Liu Hai 2018/11/29 Cheng Kang 2018/11/29 Chris Zhong 2018/11/29 TEMPLATE FILENAME: APPLICATION_SPEC[SIZE_A](V.1).DOC 868/915MHZ FLEXIBLE ANTENNA 1.0 SCOPE This specification describes the antenna application and surrounding. The information in this document is for reference and benchmark purposes only. The user is responsible for validating antenna rf performance based on the user’s actual implementation. Antenna illustrations in this document are generic representations. They are not intended to be an image of any antenna listed in the scope. 2.0 PRODUCT DESCRIPTION 2.1 PRODUCT NAME AND SERIES NUMBER (S) Product name: 868/915MHz Flexible Antenna Series Number: 211140 2.2 DESCRIPTION 211140 is a monopole flexible antenna for ISM 868/915MHz dual band. Antenna size 38x10x0.1mm is made from flexible polymer material, cable standard length 100mm. It can be easily installed by simply “peel and stick” on non-metal surface. 2.3 PRODUCT STRUCTURE INFORMATION Please refer to PS-2111400100 for full information. Molex 2111400100 868/915MHz Flexible Antenna 3D View APPLICATION SPECIFICATION REVISION: ECR/ECN INFORMATION: TITLE: 868/915MHz Flexible Antenna Application Specification SHEET No. A EC No: 608264 3 of 20 DATE: 2018/12/03 DOCUMENT NUMBER: CREATED / REVISED BY: CHECKED BY: APPROVED BY: AS-2111400100 Liu Hai 2018/11/29 Cheng Kang 2018/11/29 Chris Zhong 2018/11/29 TEMPLATE FILENAME: APPLICATION_SPEC[SIZE_A](V.1).DOC 3.0 APPLICABLE DOCUMENTS DOCUMENT NUMBER DESCRIPTION Sale Drawing(SD) SD-2111400100 Mechanical Dimension of the product Product Specification (PS) PS-2111400100 Product Specification Packing Drawing(PK) PK-2111400100 Product packaging specifications 4.0 ANTENNA PERFORMANCE 4.1 RF TEST CONDITIONS All measurements are done of the antenna mounted on a PC/ABS material block of 1.5mm thickness with VNA Agilent 5071C and Over-The-Air (OTA) chamber. All measurements in this document are done with the part no.2111400100 with a cable length of 100mm. FIGURE4.1.1 ANTENNA LOADED WITH PC/ABS BLOCK OF 1.5 MM THICKNESS APPLICATION SPECIFICATION REVISION: ECR/ECN INFORMATION: TITLE: 868/915MHz Flexible Antenna Application Specification SHEET No. A EC No: 608264 4 of 20 DATE: 2018/12/03 DOCUMENT NUMBER: CREATED / REVISED BY: CHECKED BY: APPROVED BY: AS-2111400100 Liu Hai 2018/11/29 Cheng Kang 2018/11/29 Chris Zhong 2018/11/29 TEMPLATE FILENAME: APPLICATION_SPEC[SIZE_A](V.1).DOC FIGURE4.1.2 ANTENNA LOADED WITH PC/ABS BLOCK OF 1.5 MM THICKNESS WITH VNA APPLICATION SPECIFICATION REVISION: ECR/ECN INFORMATION: TITLE: 868/915MHz Flexible Antenna Application Specification SHEET No. A EC No: 608264 5 of 20 DATE: 2018/12/03 DOCUMENT NUMBER: CREATED / REVISED BY: CHECKED BY: APPROVED BY: AS-2111400100 Liu Hai 2018/11/29 Cheng Kang 2018/11/29 Chris Zhong 2018/11/29 TEMPLATE FILENAME: APPLICATION_SPEC[SIZE_A](V.1).DOC FIGURE4.1.3 ANTENNA LOADED WITH PC/ABS BLOCK OF 1.5 MM THICKNESS WITH OTA CHAMBER APPLICATION SPECIFICATION REVISION: ECR/ECN INFORMATION: TITLE: 868/915MHz Flexible Antenna Application Specification SHEET No. A EC No: 608264 6 of 20 DATE: 2018/12/03 DOCUMENT NUMBER: CREATED / REVISED BY: CHECKED BY: APPROVED BY: AS-2111400100 Liu Hai 2018/11/29 Cheng Kang 2018/11/29 Chris Zhong 2018/11/29 TEMPLATE FILENAME: APPLICATION_SPEC[SIZE_A](V.1).DOC 4.2 ANTENNA PERFORMANCE DESCRIPTION EQUIPMENT REQUIREMENT Frequency Range VNA E5071C 868-870MHz 902-928MHz Return Loss VNA E5071C <- 5dB Peak Gain (Max) OTA Chamber 0.3dBi 1.0dBi Average Total Efficiency OTA Chamber >55% >60% Polarization OTA Chamber Linear Input Impedance VNA E5071C 50 ohms Note that the above antenna performance is measured with just the antenna mounted on a PC/ABS block to similar a free-space condition. When implement into the system, the frequency resonant might be off-tune due to the loading of surrounding components especially metal plane. This off-tune can be compensated through matching. Although module manufacturers specify a peak gain limit, it is based on free-space conditions. The peak gain will be degraded by 1 to 2dBi in the actual implementation as the radiation pattern will change due to the surround components. As such, during selection of antenna, you can select one with high peak gain to compensate for the loss. Molex can offer assistant to choose the best location and best tuning in-order to meet this peak gain requirement. APPLICATION SPECIFICATION REVISION: ECR/ECN INFORMATION: TITLE: 868/915MHz Flexible Antenna Application Specification SHEET No. A EC No: 608264 7 of 20 DATE: 2018/12/03 DOCUMENT NUMBER: CREATED / REVISED BY: CHECKED BY: APPROVED BY: AS-2111400100 Liu Hai 2018/11/29 Cheng Kang 2018/11/29 Chris Zhong 2018/11/29 TEMPLATE FILENAME: APPLICATION_SPEC[SIZE_A](V.1).DOC 4.3 RETURN LOSS PLOT All measurements in this document are done with a cable length of 100mm. FIGURE 4.3.1 RETURN LOSS OF ANTENNA AT 868/915MHZ IN FREE SPACE APPLICATION SPECIFICATION REVISION: ECR/ECN INFORMATION: TITLE: 868/915MHz Flexible Antenna Application Specification SHEET No. A EC No: 608264 8 of 20 DATE: 2018/12/03 DOCUMENT NUMBER: CREATED / REVISED BY: CHECKED BY: APPROVED BY: AS-2111400100 Liu Hai 2018/11/29 Cheng Kang 2018/11/29 Chr…

Text truncated - open the document above for the full version.

Test Report

Prüfbericht - Produkte Test Report - Products Prüfbericht-Nr.: Test report no.: IN25SCW8 001 Auftrags-Nr.: Order no.: 147104915 010 Seite 1 von 45 Page 1 of 45 Kunden-Referenz-Nr.: Client reference no.: 2566340 Auftragsdatum: Order date: 2025-09-09 Auftraggeber: Client: 75F Inc. , 1650 W, 82nd St, #200, Bloomington, Minnesota, USA - 55431 Prüfgegenstand: Test item: MyStat Bezeichnung / Typ-Nr.: Identification / Type no.: Main Model: 7X-TS-C4K-C2 Associated Model: 7X-TS-C4K-X; 7C-TS-C4K-C2; 7C-TS-C4K-X; Auftrags-Inhalt: Order content: Testing and issue of Test Report with Grant Certificate Prüfgrundlage: Test specification: FCC Part15 SubpartC 15.247; 15.205; 15.207; 15.209 RSS Gen Issue 5; RSS 247 Issue 4 Wareneingangsdatum: Date of sample receipt: 2025-09-10 Prüfmuster-Nr.: Test sample no: A004088908-001 A004088908-002 Prüfzeitraum: Testing period: 2025-09-15 - 2025-10-13 Ort der Prüfung: Place of testing: Wireless laboratory, Bangalore Prüflaboratorium: Testing laboratory: TÜV Rheinland (India) Pvt.Ltd., 27/B, 2nd Cross, Electronic City Phase1 Bangalore -560 100, India FCC Test site registration number: 496599 ISED Test site registration number: 27711 Prüfergebnis*: Test result*: Pass geprüft von: tested by: X Signed by: Naveen Kumar Muthyalapati Venkata genehmigt von: authorized by: X Signed by: Madhu Nagaraju Datum: Date: 2025-11-07 Ausstellungsdatum: Issue date: 2025-11-07 Stellung / Position: Senior Engineer Stellung / Position: Assistant Manager Sonstiges / Other: FCC ID: 2AVZO-101644 IC: 25972-101644 Zustand des Prüfgegenstandes bei Anlieferung: Condition of the test item at delivery: Prüfmuster vollständig und unbeschädigt Test item complete and undamaged * Legende: P(ass) = entspricht o.g. Prüfgrundlage(n) F(ail) = entspricht nicht o.g. Prüfgrundlage(n) N/A = nicht anwendbar N/T = nicht getestet * Legend: P(ass) = passed a.m. test specification(s) F(ail) = failed a.m. test specification(s) N/A = not applicable N/T = not tested Dieser Prüfbericht bezieht sich nur auf das o.g. Prüfmuster und darf ohne Genehmigung der Prüfstelle nicht auszugsweise vervielfältigt werden. Dieser Bericht berechtigt nicht zur Verwendung eines Prüfzeichens. This test report only relates to the above mentioned test sample. Without permission of the test center this test report is not permitted to be duplicated in extracts. This test report does not entitle to carry any test mark. TÜV Rheinland (India) Pvt. Ltd. # 27/B, 2nd Cross Road, Electronics City Phase 1, Bangalore – 560 100, INDIA. Mail: [email protected] ∙ Web: www.ind.tuv.com V101023IMEASR Produkte Products www.tuv.com Prüfbericht - Nr.: Test Report No.: IN25SCW8 001 Seite 2 von 45 Page 2 of 45 1 Alle eingesetzten Prüfmittel waren zum angegebenen Prüfzeitraum gemäß eines festgelegten Kalibrierungsprogramms unseres Prüfhauses kalibriert. Sie entsprechen den in den Prüfprogrammen hinterlegten Anforderungen. Die Rückverfolgbarkeit der eingesetzten Prüfmittel ist durch die Einhaltung der Regelungen unseres Managementsystems gegeben. Detaillierte Informationen bezüglich Prüfkonditionen, Prüfequipment und Messunsicherheiten sind im Prüflabor vorhanden und können auf Wunsch bereitgestellt werden. The equipment used during the specified testing period was calibrated according to our test laboratory calibration program. The equipment fulfils the requirements included in the relevant standards. The traceability of the test equipment used is ensured by compliance with the regulations of our management system. Detailed information regarding test conditions, equipment and measurement uncertainty is available in the test laboratory and could be provided on request. 2 Wie vertraglich vereinbart, wurde dieses Dokument nur digital unterzeichnet. Der TÜV Rheinland hat nicht überprüft, welche rechtlichen oder sonstigen diesbezüglichen Anforderungen für dieses Dokument gelten. Diese Überprüfung liegt in der Verantwortung des Benutzers dieses Dokuments. Auf Verlangen des Kunden kann der TÜV Rheinland die Gültigkeit der digitalen Signatur durch ein gesondertes Dokument bestätigen. Diese Anfrage ist an unseren Vertrieb zu richten. Eine Umweltgebühr für einen solchen zusätzlichen Service wird erhoben. Informationen zur Verifizierung der Authentizität unserer Dokumente erhalten Sie auf folgender Webseite: go.tuv.com/digital-signature As contractually agreed, this document has been signed digitally only. TUV Rheinland has not verified and unable to verify which legal or other pertaining requirements are applicable for this document. Such verification is within the responsibility of the user of this document. Upon request by its client, TUV Rheinland can confirm the validity of the digital signature by a separate document. Such request shall be addressed to our Sales department. An environmental fee for such additional service will be charged. For information on verifying the authenticity of our documents, please visit the following website: go.tuv.com/digital-signature 3 Prüfklausel mit der Note * wurden an qualifizierte Unterauftragnehmer vergeben und sind unter der jeweiligen Prüfklausel des Berichts beschrieben. Abweichungen von Prüfspezifikation(en) oder Kundenanforderungen sind in der jeweiligen Prüfklausel im Bericht aufgeführt. Test clauses with remark of * are subcontracted to qualified subcontractors and descripted under the respective test clause in the report. Deviations of testing specification(s) or customer requirements are listed in specific test clause in the report. 4 Die Entscheidungsregel für Konformitätserklärungen basierend auf numerischen Messergebnisen in diesem Prüfbericht basiert auf der "Null-Grenzwert-Regel" und der "Einfachen Akzeptanz" gemäß ILAC G8:2019 und IEC Guide 115:2023, es sei denn, in der auf Seite 1 dieses Berichts genannten angewandten Norm ist etwas anderes festgelegt oder vom Kunden gewünscht. Dies bedeutet, dass die Messunsicherheit nicht berücksichtigt wird und daher auch nicht im Prüfbericht angegeben wird. Zu weiteren Informat…

Text truncated - open the document above for the full version.

Test Report

Prüfbericht - Produkte Test Report - Products Prüfbericht-Nr.: Test report no.: IN25KPWW 001 Auftrags-Nr.: Order no.: 147104915 010 Seite 1 von 44 Page 1 of 44 Kunden-Referenz-Nr.: Client reference no.: 2566340 Auftragsdatum: Order date: 2025-09-09 Auftraggeber: Client: 75F Inc. , 1650 W, 82nd St, #200, Bloomington, Minnesota, USA - 55431 Prüfgegenstand: Test item: MyStat Bezeichnung / Typ-Nr.: Identification / Type no.: Main Model: 7X-TS-C4K-C2 Associated Model: 7X-TS-C4K-X; 7C-TS-C4K-C2; 7C-TS-C4K-X; Auftrags-Inhalt: Order content: Testing and issue of Test Report with Grant Certificate Prüfgrundlage: Test specification: FCC Part15 SubpartC 15.247; 15.205; 15.207; 15.209 RSS Gen Issue 5; RSS 247 Issue 4 Wareneingangsdatum: Date of sample receipt: 2025-09-10 Prüfmuster-Nr.: Test sample no: A004088908-001 A004088908-002 Prüfzeitraum: Testing period: 2025-09-15 - 2025-10-13 Ort der Prüfung: Place of testing: Wireless laboratory, Bangalore Prüflaboratorium: Testing laboratory: TÜV Rheinland (India) Pvt.Ltd., 27/B, 2nd Cross, Electronic City Phase1 Bangalore -560 100, India FCC Test site registration number: 496599 ISED Test site registration number: 27711 Prüfergebnis*: Test result*: Pass geprüft von: tested by: X Signed by: Naveen Kumar Muthyalapati Venkata genehmigt von: authorized by: X Signed by: Madhu Nagaraju Datum: Date: 2025-11-07 Ausstellungsdatum: Issue date: 2025-11-07 Stellung / Position: Senior Engineer Stellung / Position: Assistant Manager Sonstiges / Other: FCC ID: 2AVZO-101644 IC: 25972-101644 Zustand des Prüfgegenstandes bei Anlieferung: Condition of the test item at delivery: Prüfmuster vollständig und unbeschädigt Test item complete and undamaged * Legende: P(ass) = entspricht o.g. Prüfgrundlage(n) F(ail) = entspricht nicht o.g. Prüfgrundlage(n) N/A = nicht anwendbar N/T = nicht getestet * Legend: P(ass) = passed a.m. test specification(s) F(ail) = failed a.m. test specification(s) N/A = not applicable N/T = not tested Dieser Prüfbericht bezieht sich nur auf das o.g. Prüfmuster und darf ohne Genehmigung der Prüfstelle nicht auszugsweise vervielfältigt werden. Dieser Bericht berechtigt nicht zur Verwendung eines Prüfzeichens. This test report only relates to the above mentioned test sample. Without permission of the test center this test report is not permitted to be duplicated in extracts. This test report does not entitle to carry any test mark. TÜV Rheinland (India) Pvt. Ltd. # 27/B, 2nd Cross Road, Electronics City Phase 1, Bangalore – 560 100, INDIA. Mail: [email protected] ∙ Web: www.ind.tuv.com V101023IMEASR Produkte Products www.tuv.com Prüfbericht - Nr.: Test Report No.: IN25KPWW 001 Seite 2 von 44 Page 2 of 44 1 Alle eingesetzten Prüfmittel waren zum angegebenen Prüfzeitraum gemäß eines festgelegten Kalibrierungsprogramms unseres Prüfhauses kalibriert. Sie entsprechen den in den Prüfprogrammen hinterlegten Anforderungen. Die Rückverfolgbarkeit der eingesetzten Prüfmittel ist durch die Einhaltung der Regelungen unseres Managementsystems gegeben. Detaillierte Informationen bezüglich Prüfkonditionen, Prüfequipment und Messunsicherheiten sind im Prüflabor vorhanden und können auf Wunsch bereitgestellt werden. The equipment used during the specified testing period was calibrated according to our test laboratory calibration program. The equipment fulfils the requirements included in the relevant standards. The traceability of the test equipment used is ensured by compliance with the regulations of our management system. Detailed information regarding test conditions, equipment and measurement uncertainty is available in the test laboratory and could be provided on request. 2 Wie vertraglich vereinbart, wurde dieses Dokument nur digital unterzeichnet. Der TÜV Rheinland hat nicht überprüft, welche rechtlichen oder sonstigen diesbezüglichen Anforderungen für dieses Dokument gelten. Diese Überprüfung liegt in der Verantwortung des Benutzers dieses Dokuments. Auf Verlangen des Kunden kann der TÜV Rheinland die Gültigkeit der digitalen Signatur durch ein gesondertes Dokument bestätigen. Diese Anfrage ist an unseren Vertrieb zu richten. Eine Umweltgebühr für einen solchen zusätzlichen Service wird erhoben. Informationen zur Verifizierung der Authentizität unserer Dokumente erhalten Sie auf folgender Webseite: go.tuv.com/digital-signature As contractually agreed, this document has been signed digitally only. TUV Rheinland has not verified and unable to verify which legal or other pertaining requirements are applicable for this document. Such verification is within the responsibility of the user of this document. Upon request by its client, TUV Rheinland can confirm the validity of the digital signature by a separate document. Such request shall be addressed to our Sales department. An environmental fee for such additional service will be charged. For information on verifying the authenticity of our documents, please visit the following website: go.tuv.com/digital-signature 3 Prüfklausel mit der Note * wurden an qualifizierte Unterauftragnehmer vergeben und sind unter der jeweiligen Prüfklausel des Berichts beschrieben. Abweichungen von Prüfspezifikation(en) oder Kundenanforderungen sind in der jeweiligen Prüfklausel im Bericht aufgeführt. Test clauses with remark of * are subcontracted to qualified subcontractors and descripted under the respective test clause in the report. Deviations of testing specification(s) or customer requirements are listed in specific test clause in the report. 4 Die Entscheidungsregel für Konformitätserklärungen basierend auf numerischen Messergebnisen in diesem Prüfbericht basiert auf der "Null-Grenzwert-Regel" und der "Einfachen Akzeptanz" gemäß ILAC G8:2019 und IEC Guide 115:2023, es sei denn, in der auf Seite 1 dieses Berichts genannten angewandten Norm ist etwas anderes festgelegt oder vom Kunden gewünscht. Dies bedeutet, dass die Messunsicherheit nicht berücksichtigt wird und daher auch nicht im Prüfbericht angegeben wird. Zu weiteren Informat…

Text truncated - open the document above for the full version.

Contact Information

Applicant

Alex Schwalbe(Quality Assurance Technician)
[email protected]Fax: 888-590-8995

Test Firm

TUV RHEINLAND (INDIA) PVT. LTD.Guruprasad BR
[email protected]

Technical Specifications

#Rule PartsFrequency RangePower Output
115C2.40 GHz - 2.48 GHz1.90 mW
215C906 MHz - 924 MHz10.10 mW
Confidentiality
Long Term
Grant Notes
Power output listed is peak conducted. The antennas used for this device must be installed to provide a separation distance of at least 20 cm from all persons and not be co-located with any other transmitters except in accordance with FCC multi-transmitter product procedures. End user must be provided with transmitter operating conditions for satisfying RF exposure compliance.

Other Applications from 75F, Inc.

2AVZO-101566

WIRED MULTI SENSOR

Apr 10, 2026

Equipment Class

DTS - Digital Transmission System
2AVZO-101317

Wireless MultiSensor

Apr 03, 2026

Equipment Class

DTS - Digital Transmission System
2AVZO-101565

MYSENSE

Mar 27, 2026

Equipment Class

DTS - Digital Transmission System
TABLET PC - FCC ID 2AVZO-T8045PC - 75F, Inc.
2AVZO-T8045PC

TABLET PC

Dec 02, 2023

Equipment Class

DSS - Part 15 Spread Spectrum Transmitter
Tablet 8 - XR - FCC ID 2AVZO-CCU - 75F, Inc.
2AVZO-CCU

Tablet 8 - XR

Nov 04, 2023

Equipment Class

NII - Unlicensed National Information Infrastructure TX