FCCID.CO- FCC ID Database
HomeCompaniesEquipment ClassesSearch

© 2026 FCC ID Database. All rights reserved.

AboutContactData sourced from FCC public records
  1. Home/
  2. Shanghai Ogino Biotechnology Co., Ltd./
  3. 2AW3Z-WRGBRGBAPLUS

2AW3Z-WRGBRGBAPLUSChihiros WRGBII Series ligting system

Shanghai Ogino Biotechnology Co., Ltd.
Chihiros WRGBII Series ligting system - FCC ID 2AW3Z-WRGBRGBAPLUS - Shanghai Ogino Biotechnology Co., Ltd.
Click to zoom

Application Details

Equipment Class
DTS - Digital Transmission System
Date of Grant
Jul 30, 2020
Application Purpose
Original Equipment
Date of Application
Jul 30, 2020
Equipment Note
Chihiros WRGBII Series ligting system
Frequency Range
2402.00000000 - 2480.00000000
Company
Shanghai Ogino Biotechnology Co., Ltd.
Country
China

Documents & Files

Select a file to view

Users Manual

↗

Cover Letter(s)

↗
↗
↗

External Photos

↗

ID Label/Location Info

↗

Internal Photos

↗

RF Exposure Info

↗

Test Report

↗

Test Setup Photos

↗

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

Users Manual

20C

Cover Letter(s)

Co m Ad d Chin Pr o Mo d A30 Pr o We act We an d issu our Sig Na m Title Com mpany: Sh dress: Rm.33 na oduct Name del Numbe 01PLUS, RG oduct Desc authorize M on our beha declare tha d certificatio ues concern behalf shal nature: me: e: mpany: S anghai Og 30, Bldg.3, N e: Chihiros er(s): WRGB GB A451PL ription: Ch MiCOM Lab alf on all ma at MiCOM L n of equipm ning the app ll have the s huancong Legal pers Shanghai Shanghai O Agen ino Biotec No.2028, Jian s WRGBII S B120II, WR LUS, RGB A hihiros WRG bs Inc., 575 atters conce Labs Inc. is ment to the r proval applic same effect Ma son Ogino Biote Ogino Biote nt Auth hnology Co nshe Rd., Ji Series ligtin RGB30II, WR A601PLUS GBII Series Boulder Co erning the c allowed to f regulatory a cation. Any t as acts of echnology C echnology horizat o., Ltd. ianshe Coun ng system RGB45II, W S, RGB A90 s ligting sy ourt, Pleasa certification forward all i agencies as and all acts our own. Co., Ltd. Co., Ltd. tion nty, Chongm WRGB60II, W 01PLUS, RG ystem anton, Califo of above na information s required a s carried ou Date: ming Distric WRGB90II, GB A1201P ornia 94566 amed equip related to t nd to discu ut by MiCOM Jul. 30, 202 t, Shanghai , RGB PLUS 6, USA, to pment. the approva ss any M Labs on 20 , al

Cover Letter(s)

Office o Federa 7435 O Columb USA Subjec t FCC ID To Wh o Pursua are req u docume These d propriet might b It is ou r corresp docume authoriz Sincer e Signat u Name: Title: L e of Engineeri l Communic Oakland Mills bia, MD 210 t; Request f D: 2AW3Z-W om It May C nt to the pro uesting the ents from pu documents tary informa be harmful to Schema Block D Parts Lis Operatio r understand pondence du ents and thi zation is iss ely, ure: huancong M egal person S ing Techno cations Com s Road 046 for Confiden WRGBRG Concern, ovisions of t Commissio ublic disclos contain det ation in ope o our comp atic Diagram iagram st onal Descri ding that all uring the ce s informatio sued. Ma n hanghai Og logy mmission ntiality BAPLUS the Commis on to withho sure indefin tailed syste ration of th e any and wo m ption l measurem ertification re on will be av gino Biotech ssion’s rule old the follow nitely. m and equi e equipmen ould give co ment test rep eview proce vailable for hnology Co s Title 47 S wing attach pment desc nt. The publ ompetitors a ports, FCC ess cannot public revi e ., Ltd. Sections §0. hment(s) as criptions an ic disclosu r an unfair ad ID label for be granted ew once the Date: Jul. 3 457 and §0 confidentia d are consi re of these d vantage in mat and as confide n e grant of eq 30, 2020 0.459, we al dered as documents the market . ntial quipment .

Cover Letter(s)

Model Difference Declaration To Whom It May Concern, We, Shanghai Ogino Biotechnology Co., Ltd. (Chihiros WRGBII Series ligting system ) Trademark:Chihiros Aqutic studio; Model Number: WRGB120II, WRGB30II, WRGB45II, WRGB60II, WRGB90II, RGB A301PLUS, RGB A451PLUS, RGB A601PLUS, RGB A901PLUS, RGB A1201PLUS;All model’s the function, software and electric circuit are the same, only with a product model named different for commercial purpose. Test sample model: WRGB120II. Please contact me if you have any question. Name: huancong Ma Date: Jul. 30, 2020 Title: Legal person Signature of applicant:

External Photos

Annex A External Photos Report No.: HK2007271966‐E Page 1 of 4 Report No.: HK2007271966‐E Page 2 of 4 Report No.: HK2007271966‐E Page 3 of 4 Report No.: HK2007271966‐E Page 4 of 4

ID Label/Location Info

FCC ID LABEL: Label Location Width: 2cm Long: 4cm FCC ID: 2AW3Z-WRGBRGBAPLUS Product name: Chihiros WRGBII Series ligting system Model No.: WRGB120II This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1)This device may not cause harmful interference, and (2)This device must accept any interference received, including interference that may cause undesired operation.

Internal Photos

Annex B Internal Photo Report No.: HK2007271966-E Page 1 of 3 Report No.: HK2007271966-E Page 2 of 3 Antenna Report No.: HK2007271966-E Page 3 of 3

RF Exposure Info

MPE ESTIMATION FCC ID: 2AW3Z-WRGBRGBAPLUS 1,Limit for General Population/ Uncontrolled Exposures Frequency Power density (mW/ cm 2 ) Averaging time(minutes) 300MHz----1.5GHz F/1500 30 1.5GHz---100GHz 1.0 30 Note: F= Frequency in MHz 2, Estimation Result WIFI Mode Max PK Output power(dBm) Tune Up Power(dBm) Max Tune Up power(mW) Antenna Gain(dBi) Antenna Gain (numerical) MPE ( mW/cm²) BLE -3.18 -3±1(-2) 0.631 -0.58 0.8750 0.00011 Note: Note: The estimation distance is 20cm Note: PK Output power= conducted power. Conducted power see the test report HK2007271966-E, antenna gain=-0.58dBi simultaneously MPE when the minimum test separation distance is >20 cm, a distance of 20 cm is applied to determine RF Exposure test exclusion. The test exclusion threshold is 0.00011 mW/cm² which is< 1.0mW/cm², RF Exposure testing is not required. -------The End-------

Test Report

Page 1 of 43 Report No.: HK2007271966-E TEST REPORT FCC PART 15 SUBPART C 15.247 Test report On Behalf of Shanghai Ogino Biotechnology Co., Ltd. For Chihiros WRGBII Series ligting system Model No.: WRGB120II, Please refer to page 8 for Serial models FCC ID: 2AW3Z-WRGBRGBAPLUS Prepared for : Shanghai Ogino Biotechnology Co., Ltd. Rm.330, Bldg.3, No.2028, Jianshe Rd., Jianshe County, Chongming District, Shanghai, China Prepared By : Shenzhen HUAK Testing Technology Co., Ltd. 1F, B2 Building, Junfeng Zhongcheng Zhizao Innovation Park, Fuhai Street, Bao'an District, Shenzhen City, China Date of Test: Jul. 22, 2020 ~ Jul. 29, 2020 Date of Report: Jul. 29, 2020 Report Number: HK2007271966-E Page 2 of 43 Report No.: HK2007271966-E TEST RESULT CERTIFICATION Applicant’s name ................... : Shanghai Ogino Biotechnology Co., Ltd. Address .................................... : Rm.330, Bldg.3, No.2028, Jianshe Rd., Jianshe County, Chongming District, Shanghai, China Manufacture's Name .............. : Shanghai Ogino Biotechnology Co., Ltd.(CIXI branch) Address .................................... : No.1999 XISANHUAN ROAD, CIXI CITY, NINGBO, ZHEJIANG, CHINA Product description Trade Mark: Chihiros Aqutic studio Product name ............................. : Chihiros WRGBII Series ligting system Model and/or type reference .. : WRGB120II, Please refer to page 8 for Serial models Standards ................................ : 47 CFR FCC Part 15 Subpart C 15.247 This publication may be reproduced in whole or in part for non-commercial purposes as long as the Shenzhen HUAK Testing Technology Co., Ltd. is acknowledged as copyright owner and source of the material. Shenzhen HUAK Testing Technology Co., Ltd. takes no responsibility for and will not assume liability for damages resulting from the reader's interpretation of the reproduced material due to its placement and context. Date of Test .............................................. : Date (s) of performance of tests ................ : Jul. 22, 2020 ~ Jul. 29, 2020 Date of Issue ............................................. : Jul. 29, 2020 Test Result ................................................. : Pass Prepared by: Project Engineer Reviewed by: Project Supervisor Approved by: Technical Director Page 3 of 43 Report No.: HK2007271966-E Contents Page CONTENTS .............................................................................................................................................................. 3 1 TEST SUMMARY ............................................................................................................................................ 6 1.1 TEST DESCRIPTION ...................................................................................................................................... 6 1.2 MEASUREMENT UNCERTAINTY ...................................................................................................................... 7 2 TEST FACILITY ............................................................................................................................................... 8 3 GENERAL INFORMATION ............................................................................................................................. 8 3.1 GENERAL DESCRIPTION OF EUT .................................................................................................................. 8 3.2 DESCRIPTION OF TEST CONDITIONS ............................................................................................................ 10 3.3 DESCRIPTION OF TEST SETUP ........................................................................................................... 10 4 EQUIPMENTS LIST FOR ALL TEST ITEMS ............................................................................................... 11 5 TEST RESULT .............................................................................................................................................. 13 5.1 ANTENNA REQUIREMENT ............................................................................................................................ 13 5.1.1 Standard requirement ...................................................................................................................... 13 5.1.2 EUT Antenna ................................................................................................................................... 13 5.2 CONDUCTION EMISSIONS MEASUREMENT ................................................................................................... 14 5.2.1 Applied procedures / Limit ............................................................................................................... 14 5.2.2 Test procedure ................................................................................................................................. 14 5.2.3 Test setup ........................................................................................................................................ 15 5.2.4 Test results ...................................................................................................................................... 16 5.3 RADIATED EMISSIONS MEASUREMENT ........................................................................................................ 18 5.3.1 Applied procedures / Limit ............................................................................................................... 18 5.3.2 Test setup ........................................................................................................................................ 18 5.3.3 Test Result ....................................................................................................................................... 20 5.4 MAXIMUM OUTPUT POWER MEASUREMENT ................................................................................................. 27 5.4.1 Limit .........................…

Text truncated - open the document above for the full version.

Test Setup Photos

Conducted Emission Radiated Emissions

Contact Information

Applicant

huancong Ma(Legal person)
[email protected]15824218120Fax: 021-56370550

Technical Contact

Shanghai Ogino Biotechnology Co., Ltd
[email protected]

China

Test Firm

Shenzhen HUAK Testing Technology Co., Ltd.Jason Zhou
[email protected]+86-755-23029901

Technical Specifications

#Rule PartsFrequency RangePower Output
115C2.40 GHz - 2.48 GHz480.00 µW
Confidentiality
Long Term
Grant Notes
Output power listed is conducted power. The antenna used with this transmitter must be installed to provide a minimum separation distance of at least 20 cm from all persons and must not be co-located or operating in conjunction with any other antenna or transmitter, except in accordance with FCC multi- transmitter product procedures. End-users must be provided with operating procedures for satisfying RF exposure compliance.

Other Applications from Shanghai Ogino Biotechnology Co., Ltd.

2AW3Z-WRGBVIVID3

Chihiros WRGB VIVID3

Oct 10, 2024

Equipment Class

DTS - Digital Transmission System
Chihiros Magnetic stirrers - FCC ID 2AW3Z-MAGNETIC - Shanghai Ogino Biotechnology Co., Ltd.
2AW3Z-MAGNETIC

Chihiros Magnetic stirrers

Feb 19, 2024

Equipment Class

DTS - Digital Transmission System
Chihiros RGB VIVID II Series LED lighting system - FCC ID 2AW3Z-RGBVIVIDII - Shanghai Ogino Biotechnology Co., Ltd.
2AW3Z-RGBVIVIDII

Chihiros RGB VIVID II Series LED lighting system

Jul 30, 2020

Equipment Class

DTS - Digital Transmission System