Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.
5000mAh Ultra-thin Magnetic Wireless Power Bank User Guide What’s In The Box 30cm USB-A to Type-C cable Specifications Model Capacity Input Output Weight Wireless Output 5000mAh 3.87Vdc / 19.35Wh LWP-05103A01 Type-C: DC 5V 2.4A 125g ± 10g Dimensions105 x 66 x 9 mm Type-C: DC 5V 3A Charging Your Device To charge your device with the wireless charger: 1. Place a compatible phone or tablet on the suction pad of the wireless power bank, the suction pad free your hands at all. 2. Press the power button once to activate charging for your device 3. For 5W wireless charging, please do not charge other device at the same time Method 1 Note: Please do not place metallic objects over the wireless charging zone while charging your device Notices LED on / LED off Indicator Battery Level 100% - 75% 75% - 50% 50% - 25% 25% Flashing / LED on / LED off Indicator Battery Level 0% - 25 % 25% - 50% 50% - 75% 75% 100% 100% Recharge Your Wireless Power Bank Use a 2A adapter to achieve the fastest recharge through Micro USB port or Type-C port. Method 2 To charge your device with the USB-A port: 1. Connect your device to LWP-05103A01 with the USB-A charging cable When using the wireless charger, the LED indicator will light up accordingly. When using the USB charging, the LED indicator will light up accordingly to indicate the battery level of your charger. Status indicator Introductions Flashing status The LED indicators light up O status Green light is on The green light keeps blinking Status indication Power-on Standby Charging Abnormal Do not place too close to a magnetic card with a magnetic stripe or chip(ID card, bank card,etc.) to avoid magnetic failure. Do not place metal or metal shell on the wireless charging dock. Avoid strong blows and collisions with this product. This product is a high-precision electronic product. Do not disassemble or modify by yourself. The product should not be exposed to water and water splashes. Product accessories shouldnot be placed next to liquid lled items such as cups. Please keep the distance at least 20cm between the implanted medical device (pacemaker,implantable cochlea, etc.) and the wireless charging dock to avoid potential interference tothe medical device. Please use the charger that only meets the requirements of this manual to charge the product,using a charger that does not comply with this instruction may cause danger.using a chargerthat does not comply with this instruction may cause danger. Please dispose of discarded products and accessories in accordance with relevant localenvironmental regulations. If you have any problems during using this product, please contact your local distributoror directly contact our customer service center. Please understand that there will not have prior notice if the product has any changes. Avoid using the product in the following environments: high temperature, low air pressure,humidity, excessive dust, strong magnetic eld, and prolonged exposure to the sun. We recommend that using this product in an environment where the altitude is less than 3,000meters, 0° to 35° C and 5% to 95% humidity. 成品尺寸:66.5X120mm 材质:80g书写纸 双面黑白印刷 风琴折 DC 5V 1A 5W DC 5V 1.5A 7.5W Power Bank DC 9V 1.1A 10W Type-C Input/Output Power ON/OFF Wireless Output Indicator light Warning:Changes or modifications to this unit not expressly approved by the party responsible for compliance could void the users authority to operate the equipment. NOTE:This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. FCC Statement:This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures: Reorient or relocate the receiving antenna. Increase the separation between the equipment and receiver. Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. Consult the dealer or an experienced radio/TV technician for help. RF exposure compliance statement: 1.The device has been evaluated to meet general RF exposure requirement. The device can be used in portable exposure ondition without restriction. 2.Equipment system maintenance is simple, please refer to the manual. 3.The user can take simple measures to correct the interference. Such as staying away from interference sources, turing off interference sources, etc.
Rev 1/26/2023 Shenzhen Blue Times Technology Co.,Ltd B Block,Taixinglong Tech. Zone,Hezhou, Xixiang Town, Baoan District, Shenzhen, China Federal Communications Commission Authorization and Evaluation Division 7435 Oakland Mills Road Columbia, MD 21046 USA Date: 09-10-2024 Ref: Attestation Statements Part 2.911(d)(5)(i) Filing FCC ID: 2AW54-LWP05103 Shenzhen Blue Times Technology Co.,Ltd (“the applicant”) certifies that the equipment for which authorization is sought is not “covered” equipment prohibited from receiving an equipment authorization pursuant to section 2.903 of the FCC rules. Sincerely, (signature) Name: Allen zhang Title:manager Company: Shenzhen Blue Times Technology Co.,Ltd Rev 1/26/2023 Shenzhen Blue Times Technology Co.,Ltd B Block,Taixinglong Tech. Zone,Hezhou, Xixiang Town, Baoan District, Shenzhen, China Federal Communications Commission Authorization and Evaluation Division 7435 Oakland Mills Road Columbia, MD 21046 USA Date: 9-10-2024 Ref: Attestation Statements Part 2.911(d)(5)(ii) Filing FCC ID: 2AW54-LWP05103 Shenzhen Blue Times Technology Co.,Ltd (“the applicant”) certifies that, as of the date of the filing of the application, the applicant is not identified on the Covered List (as a specifically named entity or any of its subsidiaries or affiliates) as an entity producing “covered” equipment. Sincerely, (signature) Name: Allen zhang Title:manager Company: Shenzhen Blue Times Technology Co.,Ltd
Rev 1/26/2023 Shenzhen Blue Times Technology Co.,Ltd B Block,Taixinglong Tech. Zone,Hezhou, Xixiang Town, Baoan District, Shenzhen, China Federal Communications Commission Authorization and Evaluation Division 7435 Oakland Mills Road Columbia, MD 21046 USA Date: 9-10-2024 Ref: Attestation Statements Part 2.911(d)(7) Filing FCC ID or Grantee Code: FCC ID: 2AW54-LWP05103 Applicant FRN: 0029829223 Shenzhen Blue Times Technology Co.,Ltd (“the applicant”) certifies that, as of the date of the filing of the application, REP America LLC is our designated U.S. agent for service of process for the above referenced FCC ID. REP America LLC accepts to maintain an agent for no less than one year after the grantee has terminated all marketing and importation or the conclusion of any Commission-related proceeding involving the equipment. REP America LLC accepts, as of the date of the filing of the application, the obligation of the designated U.S. agent for service of process for the above referenced FCC ID. Designated U.S. Agent Information: Name: REP America LLC U.S. Agent FRN: 0034192500 Address: REP America LLC,1942 Broadway St. STE 314C Boulder, CO 80302 United States Contact Person: Ben XU Tel.: (719) 201-3314 Email: [email protected] Sincerely, Shenzhen Blue Times Technology Co.,Ltd Allen zhang/ manager REP America LLC Ben XU/manager [Insert Applicant signature]
Rev 11/20/07 Shenzhen Blue Times Technology Co.,Ltd B Block,Taixinglong Tech. Zone,Hezhou, Xixiang Town, Baoan District, Shenzhen, China Federal Communications Commission Authorization and Evaluation Division Confidentiality Request regarding application for certification of FCC ID: 2AW54-LWP05103 Pursuant to Sections 0.457 and 0.459 of the Commission’s Rules, we hereby request confidential treatment of information accompanying this application as outlined below: Exhibit Type Block Diagram Operational Description Schematics The above materials contain trade secrets and proprietary information not customarily released to the public. The public disclosure of these materials may be harmful to the applicant and provide unjustified benefits to its competitors. The applicant understands that pursuant to Section 0.457 of the Rules, disclosure of this application and all accompanying documentation will not be made before the date of the Grant for this application. Pursuant to DA04-1705 June 15, 2004 of the Commission’s public notice, we also request temporary confidential treatment of information accompanying this application as outlined below: Exhibit Type Sincerely, (signature) Name: Allen zhang Title:manager Company: Shenzhen Blue Times Technology Co.,Ltd
Shenzhen Blue Times Technology Co.,Ltd B Block,Taixinglong Tech. Zone,Hezhou, Xixiang Town, Baoan District, Shenzhen, China Federal Communications Commission Authorization and Evaluation Division 7435 Oakland Mills Road Columbia, MD 21046 Date: 0 9-10-2024 SUBJECT: FCC Application for FCC ID: 2AW54-LWP05103 To Whom It May Concern: I, the undersigned, hereby states this equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules, and will apply the Supplier's Declaration of Conformity procedure to the class B computer peripheral portion of this composite device. I understand the following FCC requirements: 1. Devices subject to the SDoC procedure are required to be tested to show compliance with the FCC technical regulations by a recognized accredited testing laboratory. The testing laboratory must be accredited by a Commission approved accreditation body or designated under the terms of a government-to-government Mutual Recognition Agreement (MRA). A listing of those accredited testing laboratories that have been recognized by the Commission is published on the FCC Webpage: https://apps.fcc.gov/oetcf/eas/reports/TestFirmSearch.cfm(Select the "accredited" option to search for FCC recognized accredited test firms.) 2. Pt 2.1077 contains the list of information that must be included in the Supplier's Declaration of Conformity, which must be supplied with each product sold. The SDoC compliance info shall be included in the User’s Manual or as a separate sheet. The info must contain thename, address, and phone number of the responsible party, which must be located within the United States.According to 2.909(b), the responsible party is either the Manufacturer or if the product is imported the Importer. Regards, Sincerely, (signature) Name: Allen zhang Title:manager Company: Shenzhen Blue Times Technology Co.,Ltd
Shenzhen Blue Times Technology Co.,Ltd B Block,Taixinglong Tech. Zone,Hezhou, Xixiang Town, Baoan District, Shenzhen, China Federal Communications Commission Authorization and Evaluation Division 7435 Oakland Mills Road Columbia, MD 21046 Date: 09-10-2024 SUBJECT: FCC Application for FCC ID: 2AW54-LWP05103 To Whom It May Concern: We, the undersigned, hereby authorize _Colin Huang_ at __ Shenzhen DACE Testing Technology Co., Ltd.___ on our behalf, to apply to the Federal Communications Commission on our equipment. Any and all acts carried out by __ Shenzhen DACE Testing Technology Co., Ltd.__ on our behalf shall have the same effect as acts of our own. This is to advise that we are in full compliance with the Anti- Drug Abuse Act. We, the applicant, are not subject to a denial of federal benefits pursuant to Section 5301 of the Anti-Drug Act of 1988, 21 USC853a, and no party to the application is subject to a denial of federal benefits pursuant to that section. Regards, Sincerely, (signature) Name: Allen zhang Title:manager Company: Shenzhen Blue Times Technology Co.,Ltd
External
Label place(SIZE:40*0.5mm) Model:LWP-05103A01 Cell Capacity:5000mAh3.87Vdc19.35Wh Type-C IN: 5V/2.4A Type-C OUT: 5V/3A Wireless Output: 5W/7.5W/10W FCC ID: 2AW54-LWP05103
Internal ANT
V1.0ReportNo.:DACE240819002RF002 101-102BuildingH5&1/F.,BuildingH,HongfaScience&TechnologyPark,Tangtou,Shiyan,Bao’anDistrict,Shenzhen,Guangdong,China Web:http://www.poce-cert.comTel:86-755-29113252E-mail:[email protected] 1 of 13 RFExposureEvaluationReport For ShenzhenBlueTimesTechnologyCo.,Ltd ProductName:5000mAhUltra-thinMagneticWirelessPowerBank TestModel(s).:LWP-05103A01 ReportReferenceNo.:DACE240819002RF002 FCCID:2AW54-LWP05103 Applicant’sName:ShenzhenBlueTimesTechnologyCo.,Ltd Address: BBlock,TaixinglongTech.Zone,Hezhou,XixiangTown,BaoanDistrict, Shenzhen,GuangdongProvince518126,China TestingLaboratory:ShenzhenDACETestingTechnologyCo.,Ltd. Address: 101-102BuildingH5&1/F.,BuildingH,HongfaScience&Technology Park,Tangtou,Shiyan,Bao'anDistrict,Shenzhen,Guangdong,China DateofReceipt:August16,2024 DateofTest:August16,2024toSeptember9,2024 DataofIssue:September9,2024 Result:Pass Note:Thisreportshallnotbereproducedexceptinfull,withoutthewrittenapprovalofShenzhenDACE TestingTechnologyCo.,Ltd.ThisdocumentmaybealteredorrevisedbyShenzhenDACETestingTechnology Co.,Ltd.personnelonly,andshallbenotedintherevisionsectionofthedocument.Thetestresultsinthe reportonlyapplytothetestedsample. V1.0ReportNo.:DACE240819002RF002 101-102BuildingH5&1/F.,BuildingH,HongfaScience&TechnologyPark,Tangtou,Shiyan,Bao’anDistrict,Shenzhen,Guangdong,China Web:http://www.poce-cert.comTel:86-755-29113252E-mail:[email protected] 2 of 13 1GENERALINFORMATION 1.1ClientInformation Applicant’sName: ShenzhenBlueTimesTechnologyCo.,Ltd Address:BBlock,TaixinglongTech.Zone,Hezhou,XixiangTown,BaoanDistrict, Shenzhen,GuangdongProvince518126,China Manufacturer: ShenzhenBlueTimesTechnologyCo.,Ltd Address:BBlock,TaixinglongTech.Zone,Hezhou,XixiangTown,BaoanDistrict, Shenzhen,GuangdongProvince518126,China 1.2DescriptionofDevice(EUT) ProductName:5000mAhUltra-thinMagneticWirelessPowerBank Model/Typereference:LWP-05103A01 TradeMark:BlueTimes ProductDescription:5000mAhUltra-thinMagneticWirelessPowerBank PowerSupply:Battery(5000mAh/19.35Wh),chargingbyUSB-CPD5V-2.4A Operationrange:125KHz--205KHz NumberofChannels:N/A ModulationType:FSK AntennaType:InductiveloopcoilAntenna AntennaGain:0dBi HardwareVersion:V1.0 SoftwareVersion:/ 1.3DescriptionofSupportUnits TitleManufacturerModelNo.SerialNo. AC-DCadapterHUAWEIP0005/ PhoneAPPLEIPHONE14PRO/ V1.0ReportNo.:DACE240819002RF002 101-102BuildingH5&1/F.,BuildingH,HongfaScience&TechnologyPark,Tangtou,Shiyan,Bao’anDistrict,Shenzhen,Guangdong,China Web:http://www.poce-cert.comTel:86-755-29113252E-mail:[email protected] 3 of 13 1.4EquipmentsUsedDuringTheTest TestEquipmentManufacturerModelNo.SN. Cal.Date (mm-dd-yy) Cal.Duedate (mm-dd-yy) ExposureLevelTesterNardaELT-400N-02312023-12-142024-12-13 Magneticfieldprobe 100cm 2 Narda ELTprobe 100cm 2 M06752023-12-142024-12-13 1.5StatementOfTheMeasurementUncertainty TestItemMeasurementUncertainty ELT-4000.8dB Note:(1)Thisuncertaintyrepresentsanexpandeduncertaintyexpressedatapproximatelythe95% confidencelevelusingacoveragefactorofk=2. V1.0ReportNo.:DACE240819002RF002 101-102BuildingH5&1/F.,BuildingH,HongfaScience&TechnologyPark,Tangtou,Shiyan,Bao’anDistrict,Shenzhen,Guangdong,China Web:http://www.poce-cert.comTel:86-755-29113252E-mail:[email protected] 4 of 13 2EvaluationMethod 2.1ReferEvaluationMethod ANSIC95.1–1999:IEEEStandardforSafetyLevelswithRespecttoHumanExposuretoRadio FrequencyElectromagneticFields,3kHzto300GHz. FCCKDBpublication680106D01v04RFExposureWirelessChargingAppsv03:RFExposure ConsiderationsforLowPowerConsumerWirelessPowerTransferApplications FCCCFR47part11.1310:Radiofrequencyradiationexposurelimits. FCCCFR47part22.1091:Radiofrequencyradiationexposureevaluation:mobiledevices FCCCFR47part22.1093:Radiofrequencyradiationexposureevaluation:portabledevices FCCCFR47part18.107:Indusial,Scientific,andMedicalEquipment 2.2EvaluationRequirements PerKDB680106D01v04Section3.RFExposureRequirements; 1)ConsumerwirelesspowertransferdevicesapprovedunderPart18insomecaseshaveto demonstratecompliancewithRFexposurerequirements.Thepotentialforexposuremustbe assessedaccordingtotheoperatingconfigurationsofthewirelesssystemandtheexposure conditionsofusersandbystanders.RFexposuremustbeevaluatedwiththeclientdevice(s)being chargedbytheprimaryatmaximumoutputpower.TheRFexposurerequirementsmustbe determinedinconjunctionwiththedeviceoperatingcharacteristics,accordingtothemobileand portableexposurerequirementsinSection2.1091andSection2.1093oftherules.SARandMPE limitsdonotcoverthefrequencyrangeforwirelesspowertransferapplicationswhichoperatebelow 100kHzand300kHzrespectively;therefore,RFexposurecomplianceneedstobedeterminedwith respectto1.1307(c)and(d)oftheFCCrules. 2)Basedonthedesignandimplementationofthepowertransferapplication,itmustbeclearly identifiedifmobileorportableRFexposureconditionsapply.Devicesthatareinstalledtoprovide separationofatleast20cmfromusersandbystandersmayqualifyformobileexposureconditions. Forsomeconditionswhereusersandbystandersmaybeexposedatcloserthan20cm,section 2.1091(d)(4)oftherulesmayapply. 3)Fordevicesdesignedfortypicaldesktopapplications,suchawirelesschargingpads,RFexposure evaluationshouldbeconductedassumingauserseparationdistanceof15cm.EandHfield strengthmeasurementsornumericalmodelingmaybeusedtodemonstratecompliance. Measurementsshouldbemadefromallsidesandthetopoftheprimary/clientpair,withthe15cm measuredfromthecenteroftheprobe(s)totheedgeofthedevice.Emissionsbetween100kHzto 300kHzshouldbeassessedversusthelimitsat300kHzinTable1ofSection1.1310:614V/mand 1.63A/m.AKDBinquiryisrequiredtodeterminetheapplicableexposurelimitsbelow100kHz. 4)Portableexposureconditionsfrom100kHzto6GHzaredeterminedwithrespecttoSAR requirements.ExistingSARsystemsandtestproceduresaregenerallyintendedformeasurements above100MHz.Whilenumericalmodelingcanbeanalternative,theconstraintsofsubstantial computationalresourcesatlowfrequenciescouldintroducefurtherlimitations.Underthese circumstances,includingoperationsbelow100kHz,theCommissionmayconsideracombinatio…
Text truncated - open the document above for the full version.
编号 Product specifications : ZY218-509 版本:A/4 页数:1/1 客户编号 ZY218线材 样品使用线材:2LOCKCS 0.3 使用机台单轴机 客户品名 Y.013.00039雷宝规格20.5x0.3x4Px10TS+磁片绕线方向 CW 一、规格要求:(单位mm) 项目 电感 @100KHz/1 Turns V AB C (磁片边缘基准) DEFG 锡头直径 10 T标准值S6.5 uH20.545.5403.50.41.449.73.0 公差固定±10%±0.5±1.0±2.0±1.5MAXMAX±0.7MAX 样品数据 10TS6.52 uH20.4745.6414.10.351.349.92.5 二、图面说明:(单位mm) 三、BOM物料清单 物料名称规格/型号单位用量供应商备注 线材 2LOCKCS 0.3g 磁片 D49.5±0.5*0.55±0.05 单槽磁片, 含一面黑膜, 总厚0.6±0.1 PCS 双面背胶 D48.5*0.08 普通白色 无孔带手撕位 PCS 胶水 6060胶水mL 高温胶带 宽度5mm mm 泡棉盘 A11模组 专用 PCS 小号箱 版本变更内容变更日期备注 A/1增加引出线工艺要求 2021/12/24 1.绕线不可有松线、破皮、变形。变形度<1.0mm A/2内部修正规格书:重量由2.2改为3.1g 2022/3/9 A/3应客户要求增加引线出线要求 2022/10/31 本产品符合ROHS要求 A/4 客户要求变更产品总厚度由1.6MAX改为1.4MAX 2023/1/2 确认栏/Approval 客户 确认 A B E F G C D 15 max 内宽15max 磁片以内的部分4根线要水平,引线拐角处要 在磁片外部(此项很重要)。如下图所示: 引线出线要求: 这段距离的4 根线要水平 OK品 NG品 引线折 叠NG
V1.0ReportNo.:DACE240819002RF001 101-102BuildingH5&1/F.,BuildingH,HongfaScience&TechnologyPark,Tangtou,Shiyan,Bao'anDistrict,Shenzhen,Guangdong,China Web:http://www.dace-lab.comTel:+86-755-23010613E-mail:[email protected] 1 of 20 RFTESTREPORT For ShenzhenBlueTimesTechnologyCo.,Ltd ProductName:5000mAhUltra-thinMagneticWirelessPowerBank TestModel(s).:LWP-05103A01 ReportReferenceNo.:DACE240819002RF001 FCCID:2AW54-LWP05103 Applicant’sName:ShenzhenBlueTimesTechnologyCo.,Ltd Address: BBlock,TaixinglongTech.Zone,Hezhou,XixiangTown,BaoanDistrict, Shenzhen,GuangdongProvince518126,China TestingLaboratory:ShenzhenDACETestingTechnologyCo.,Ltd. Address: 101-102BuildingH5&1/F.,BuildingH,HongfaScience&Technology Park,Tangtou,Shiyan,Bao'anDistrict,Shenzhen,Guangdong,China TestSpecificationStandard:47CFRPart15.209 DateofReceipt:August16,2024 DateofTest:August16,2024toSeptember9,2024 DataofIssue:September9,2024 Result:Pass Note:Thisreportshallnotbereproducedexceptinfull,withoutthewrittenapprovalofShenzhenDACE TestingTechnologyCo.,Ltd.ThisdocumentmaybealteredorrevisedbyShenzhenDACETestingTechnology Co.,Ltd.personnelonly,andshallbenotedintherevisionsectionofthedocument.Thetestresultsinthe reportonlyapplytothetestedsample V1.0ReportNo.:DACE240819002RF001 101-102BuildingH5&1/F.,BuildingH,HongfaScience&TechnologyPark,Tangtou,Shiyan,Bao'anDistrict,Shenzhen,Guangdong,China Web:http://www.dace-lab.comTel:+86-755-23010613E-mail:[email protected] 2 of 20 RevisionHistoryOfReport VersionDescriptionREPORTNo.IssueDate V1.0OriginalDACE240819002RF001September9,2024 NOTE1: Themanufacturershouldensurethatallproductsinseriesproductionareinconformitywiththeproductsampledetailedin thisreport.Iftheproductinthisreportisusedinanyconfigurationotherthanthatdetailedinthereport,themanufacturer mustensurethenewsystemcomplieswithallrelevantstandards. Compiledby:Supervisedby:Approvedby: KerenHuang/TestEngineerStoneYin/ProjectEngineerTomChen/Manager V1.0ReportNo.:DACE240819002RF001 101-102BuildingH5&1/F.,BuildingH,HongfaScience&TechnologyPark,Tangtou,Shiyan,Bao'anDistrict,Shenzhen,Guangdong,China Web:http://www.dace-lab.comTel:+86-755-23010613E-mail:[email protected] 3 of 20 CONTENTS 1TESTSUMMARY...................................................................................................................................................4 1.1TESTSTANDARDS........................................................................................................................................4 1.2SUMMARYOFTESTRESULT.........................................................................................................................4 2GENERALINFORMATION....................................................................................................................................5 2.1CLIENTINFORMATION..................................................................................................................................5 2.2DESCRIPTIONOFDEVICE(EUT)*.................................................................................................................5 2.3DESCRIPTIONOFTESTMODES....................................................................................................................5 2.4DESCRIPTIONOFSUPPORTUNITS................................................................................................................5 2.5EQUIPMENTSUSEDDURINGTHETEST........................................................................................................6 2.6STATEMENTOFTHEMEASUREMENTUNCERTAINTY......................................................................................7 2.7AUTHORIZATIONS.........................................................................................................................................7 2.8ANNOUNCEMENT.........................................................................................................................................7 3EVALUATIONRESULTS(EVALUATION).............................................................................................................8 3.1ANTENNAREQUIREMENT..............................................................................................................................8 3.1.1Conclusion:...................................................................................................................................8 4RADIOSPECTRUMMATTERTESTRESULTS(RF)...........................................................................................9 4.1CONDUCTEDEMISSIONATACPOWERLINE..................................................................................................9 4.1.1E.U.T.Operation:..........................................................................................................................9 4.1.2TestSetupDiagram:.....................................................................................................................9 4.1.3TestData:...................................................................................................................................10 4.220DBOCCUPIEDBANDWIDTH....................................................................................................................12 4.2.1E.U.T.Operation:........................................................................................................................12 4.2.2TestSetupDiagram:...................................................................................................................13 4.2.3TestData:...................................................................................................................................13 4.3EMISSIONSINFREQUENCYBANDS(BELOW30MHZ)...................................................................................15 4.3.1E.U.T.Operation:........................................................................................................................15 4.3.2TestSetupDiagram:.......................................…
Text truncated - open the document above for the full version.
Emissionsinfrequencybands(below30MHz)-TM4 Emissionsinfrequencybands(30MHz-1GHz)-TM4 FCC ID :2AW54-LWP05103 ConductedEmissionatACpowerline
| # | Rule Parts | Frequency Range | Power Output |
|---|---|---|---|
| 1 | 15C | 0.125 MHz - 0.205 MHz | - |

Fast Wireless Charger
Equipment Class
DCD - Part 15 Low Power Transmitter Below 1705 kHz
TWS headset
Equipment Class
DSS - Part 15 Spread Spectrum Transmitter