2AW74-AERIO-300Air Purifier

Hong Kong Yunting Trading Co., Limited
Air Purifier - FCC ID 2AW74-AERIO-300 - Hong Kong Yunting Trading Co., Limited
Click to zoom

Application Details

Equipment Class
DTS - Digital Transmission System
Date of Grant
Sep 17, 2020
Application Purpose
Original Equipment
Date of Application
Sep 17, 2020
Equipment Note
Air Purifier
Frequency Range
2412.00000000 - 2462.00000000
Company
Hong Kong Yunting Trading Co., Limited
Country
China

Documents & Files

Select a file to view

Users Manual

โ†—

Cover Letter(s)

โ†—
โ†—

External Photos

โ†—

ID Label/Location Info

โ†—

Internal Photos

โ†—

RF Exposure Info

โ†—

Test Report

โ†—

Test Setup Photos

โ†—

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

Users Manual

i i

External Photos

Reference No.: WTN20F06038127W Page 1 of 3 Waltek Testing Group (Foshan) Co., Ltd. http://www.waltek.com.cn Picture 1 Picture 2 Reference No.: WTN20F06038127W Page 2 of 3 Waltek Testing Group (Foshan) Co., Ltd. http://www.waltek.com.cn Picture 3 Picture 4 Reference No.: WTN20F06038127W Page 3 of 3 Waltek Testing Group (Foshan) Co., Ltd. http://www.waltek.com.cn Picture 5 Picture 6

ID Label/Location Info

72ยฑ0.3 32ยฑ0.3 FCC ID:2AW74-AERIO-300

Internal Photos

Reference No.: WTN20F06038127W Page 1 of 4 Waltek Testing Group (Foshan) Co., Ltd. http://www.waltek.com.cn Picture 1 Picture 2 Reference No.: WTN20F06038127W Page 2 of 4 Waltek Testing Group (Foshan) Co., Ltd. http://www.waltek.com.cn Picture 3 Picture 4 Reference No.: WTN20F06038127W Page 3 of 4 Waltek Testing Group (Foshan) Co., Ltd. http://www.waltek.com.cn Picture 5 Picture 6 Reference No.: WTN20F06038127W Page 4 of 4 Waltek Testing Group (Foshan) Co., Ltd. http://www.waltek.com.cn Picture 7 Picture 8 ANT

RF Exposure Info

Reference No.: WTN20F06038127-2W Page 1 of 2 Waltek Testing Group (Foshan) Co., Ltd. http://www.waltek.com.cn 1 MAXIMUM PERMISSIBLE EXPOSURE (MPE) 1.1 General Description of E.U.T Product Name ............................... : Air Purifier Model No. ..................................... : Aerio-300 FCC ID ........................................... : 2AW74-AERIO-300 Rated Voltage ............................... : AC 100-120V, 60Hz, 36W 1.2 Standard Applicable According to ยง1.1307(b)(1) and KDB 447498 D01 General RF Exposure Guidance v06, system operating under the provisions of this section shall be operating in a manner that the public is not exposed to radio frequency energy level in excess limit for maximum permissible exposure. (a) Limits for Occupational / Controlled Exposure Frequency range (MHz) Electric Field Strength (E) (V/m) Magnetic Field Strength (H) (A/m) Power Density (S) (mW/cm 2 ) Averaging Times | E | 2 , | H | 2 or S (minutes) 0.3-3.0 614 1.63 (100)* 6 3.0-30 1842/f 4.89/f (900/f)* 6 30-300 61.4 0.163 1.0 6 300-1500 / / F/300 6 1500-100000 / / 5 6 (b) Limits for General Population / Uncontrolled Exposure Frequency range (MHz) Electric Field Strength (E) (V/m) Magnetic Field Strength (H) (A/m) Power Density (S) (mW/cm 2 ) Averaging Times | E | 2 , | H | 2 or S (minutes) 0.3-1.34 614 1.63 (100)* 30 1.34-30 824/f 2.19/f (180/f)* 30 30-300 27.5 0.073 0.2 30 300-1500 / / F/1500 30 1500-100000 / / 1 30 Note: f = frequency in MHz: * = Plane-wave equivalents power density Reference No.: WTN20F06038127-2W Page 2 of 2 Waltek Testing Group (Foshan) Co., Ltd. http://www.waltek.com.cn 1.3 MPE Calculation Method S = (30*P*G) / (377*R 2 ) S = power density (in appropriate units, e.g., mw/cm 2 ) P = power input to the antenna (in appropriate units, e.g., mw) G = power gain of the antenna in the direction of interest relative to an isotropic radiator, the power gain factor is normally numeric gain. R = distance to the center of radiation of the antenna (in appropriate units, e.g., cm) 1.4 MPE Calculation Result Prediction distance (mm) Prediction frequency (MHz) Antenna Gain (dBi) Numeric gain Maximum Tune- up output power (dBm) Maximum peak output power (mW) PD (mW/cm2) Limit (mW/cm2) >200 2412 3.0 2.0 17.18 52.240 0.020785 1.0 Result: Pass ======End of Report======

Test Report

Waltek Testing Group (Foshan) Co., Ltd. http://www.waltek.com.cn Page 1 of 57 TEST REPORT Reference No. .................... : WTN20F06038127-1W FCC ID ................................ : 2AW74-AERIO-300 Applicant ............................ : Hong Kong Yunting Trading Co., Limited Address .............................. : Unit D, 16/F, One Capital Place, 18 Luard Road, Wan Chai, Hong Kong Manufacturer .................... : Qingdao Londs Environmental Technology Co.,Ltd Address .............................. : Eastward 100 meters of Dongwangtuan Community Chengyang District ,Qingdao,266109 ,China Product Name .................... : Air Purifier Model No. ........................... : Aerio-300 Standards........................... : FCC CFR47 Part 15 Subpart C (Section 15.247): 2019 Date of Receipt sample .... : 2020-06-18 Date of Test ....................... : 2020-08-27 Date of Issue ...................... : 2020-09-01 Test Result ......................... : Pass Remarks: The results shown in this test report refer only to the sample(s) tested, this test report cannot be reproduced, except in full, without prior written permission of the company. The report would be invalid without specific stamp of test institute and the signatures of compiler and approver. Prepared By: Waltek Testing Group (Foshan) Co., Ltd. Address: No.13-19, 2/F., 2nd Building, Sunlink International Machinery City, Chencun, Shunde District, Foshan, Guangdong, China Tel:+86-757-23811398 Fax:+86-757-23811381 E-mail:[email protected] Compiled by: Approved by: Roy Hong / Project Engineer Danny Zhou / Manager Reference No.: WTN20F06038127-1W Page 2 of 57 Waltek Testing Group (Foshan) Co., Ltd. http://www.waltek.com.cn 1 Revision History Test Report No. Date of Issue Description Status WTN20F06038127-1W 2020-09-01 Original Valid Reference No.: WTN20F06038127-1W Page 3 of 57 Waltek Testing Group (Foshan) Co., Ltd. http://www.waltek.com.cn 2 Contents Page 1 REVISION HISTORY ................................................................................................................................. 2 2 CONTENTS ............................................................................................................................................... 3 3 GENERAL INFORMATION ....................................................................................................................... 4 3.1 GENERAL DESCRIPTION OF E.U.T ................................................................................................... 4 3.2 TECHNICAL CHARACTERISTICS OF EUT ........................................................................................... 4 3.3 STANDARDS APPLICABLE FOR TESTING ............................................................................................ 4 3.4 TEST FACILITY ................................................................................................................................ 5 3.5 SUBCONTRACTED ........................................................................................................................... 5 3.6 ABNORMALITIES FROM STANDARD CONDITIONS ................................................................................ 5 4 EUT SETUP AND TEST MODE ................................................................................................................ 6 5 EQUIPMENT USED DURING TEST ......................................................................................................... 7 5.1 EQUIPMENT LIST ............................................................................................................................. 7 5.2 SPECIAL ACCESSORIES AND AUXILIARY EQUIPMENT ......................................................................... 8 5.3 MEASUREMENT UNCERTAINTY ......................................................................................................... 8 6 SUMMARY OF TEST RESULT ................................................................................................................ 9 6.1 ANTENNA REQUIREMENT ............................................................................................................... 10 6.2 RF EXPOSURE REQUIREMENT ....................................................................................................... 11 6.3 RADIATED SPURIOUS EMISSIONS ................................................................................................... 12 6.4 POWER SPECTRAL DENSITY .......................................................................................................... 20 6.5 DTS BANDWIDTH .......................................................................................................................... 26 6.6 RF OUTPUT POWER ...................................................................................................................... 32 6.7 OUT OF BAND EMISSIONS .............................................................................................................. 39 6.8 CONDUCTED EMISSIONS................................................................................................................ 45 7 PHOTOGRAPHS TEST SETUP ............................................................................................................. 49 7.1 PHOTOGRAPHS - RADIATED EMISSION TEST SETUP ........................................................................ 49 7.2 PHOTOGRAPHS - CONDUCTED EMISSION TEST SETUP .................................................................... 50 8 PHOTOGRAPHS - CONSTRUCTIONAL DETAILS ............................................................................... 51 8.1 EUT - EXTERNAL VIEW ................................................................................................................. 51 8.2 EUT - INTERNAL VIEW ................................................................................................................... 54 Reference No.: WTN20F06038127-1W Page 4 of 57 Waltek Tโ€ฆ

Text truncated - open the document above for the full version.

Test Setup Photos

Reference No.: WTN20F06038127W Page 1 of 2 Waltek Testing Group (Foshan) Co., Ltd. http://www.waltek.com.cn Test Setup For Radiated Emission (30MHz to 1GHz) Test Setup For Radiated Emission (Above 1GHz) Reference No.: WTN20F06038127W Page 2 of 2 Waltek Testing Group (Foshan) Co., Ltd. http://www.waltek.com.cn Test Setup For Conducted Emission

Contact Information

Applicant

Gaimin Du
[email protected]+86 13302948759Fax: +86 13302948759

Test Firm

Waltek Testing Group (Foshan) Co. Ltd.Oren Yang
[email protected]0757-23811398Fax: 0757-23811381

Technical Specifications

#Rule PartsFrequency RangePower Output
115C2.41 GHz - 2.46 GHz52.20 mW
Confidentiality
Long Term
Grant Notes
Output power listed is the maximum conducted output power. Device must be installed and operated to provide a separation distance of at least 20cm from all persons and must not transmit simultaneously with any other antenna or transmitter, except in accordance with FCC multi-transmitter product procedures. Users and installers must be provided with antenna installation instructions and transmitter operating conditions for satisfying RF exposure compliance.

Other Applications from Hong Kong Yunting Trading Co., Limited

Air Purifier - FCC ID 2AW74-AERIO-360 - Hong Kong Yunting Trading Co., Limited
2AW74-AERIO-360

Air Purifier

Sep 22, 2020

Equipment Class

NII - Unlicensed National Information Infrastructure TX