Operating and installation instructions RF-KIT Power Amplifier RF2K-S Operating and Installing-Instructions .-. ..-. -....- -.- .. - .--. --- .-- . .-. .- -- .--. .-.. .. ..-. .. . .-. 2 Operating and installation instructions RF-KIT Power Amplifier RF2K-S Table of contents 1. Explanation of symbols, Environment protection 3 1.1 Explanation of symbols 3 1.2 Environment protection 3 1.3 Transport package 3 2. Safety informations 4 3. Control elements and connections 5 3.1 Panel description 5 3.2 Control elements and connections 6 4. Preparing for operation 7 4.1 Unpacking 7 4.2 Scope of delivery 7 4.3 Selecting a location 7 4.4 Grounding 7 4.5 Connecting exciter 7 4.6 Connecting PTT-cable 7 4.7 Preparing LAN connection 7 4.8 Connecting antenna(s) 7 4.9 AC Line cord connection 7 Dear customer, Congratulations on your purchase of a RF-KIT linear amplifier! RF-KIT devices offer innovative and reliable technology, functionality and appealing design. If, in spite of our careful quality control, you have any reason to complain or have a question about the device, please contact the dealer you trust or even directly to RF-KIT. vy 73 es gd dx de RF-KIT Reinhard Förtsch Heuleithe 14 · 91322 Gräfenberg Germany Tel.: 0049 9192 99 66 89 www.rf-kit.de · [email protected] DX Engineering 1200 Southeast Ave. Tallmadge, OH 44278 USA www.dxengineering.com © 2020 by RF-KIT Reinhard Förtsch Errors and omissions excepted. The removal of the copyright notice and the use of content, even in part, violates applicable law and is expressly prohibited. 5. Using the device locally 8 5.1 Turning device on 9 5.2 User menu 9 5.2.1 Settings 9 5.2.2 Antennas 11 5.2.3 Updates 12 5.2.4 Calibration 13 5.2.5 VNC 16 5.2.6 Interface 16 6. Antenna tuner 17 6.1 Operation 17 6.2 Input Power for tuning 18 6.3 Manual tuning 18 6.4 Automatic tuning 19 6.5 Indication area Segment-Size 20 6.6 Bypass the antenna tuner 21 7. Technical data, characteristics and certifications 22 7.1 Technical data 22 7.2 Characteristics 22 7.3 Certifications 23 3 Operating and installation instructions RF-KIT Power Amplifier RF2K-S 1. Explanation of symbols, Environment protection 1.1 Explanation of symbols Warnings Warnings are marked by a warning triangle. In addition, signal words indicate the nature and severity of the consequences if the mea- sures to avert the hazard are not followed. The following signal words are used in this document: NOTE means that property damage may occur. WARNING means that serious or even life-threatening personal injury may occur. DANGER means that serious or life-threatening personal injury will occur. Important information without danger to people or proper- ty is marked by the adjacent symbol. These informations are boanded by lines above and below the text. 1.2 Important informations SymbolMeaning ► Instruction ➔ Reference to a position in the document Enumeration/List entry - Enumeration/List entry (2 nd level) 1.3 Environment protection Disposal of packaging The packaging protects the device against damage during transport. The packaging materials are selected according to environmentally friendly and disposal-related aspects and thus recyclable. The return of the remaining packaging parts, such as packaging straps, PE bags, etc., into the material cycle saves raw materials and reduces waste. If you plan to dispose of the packing by yourself, please locate the nearest recycling center. 2. Safety informations Read these operating and installation instructions carefully and com- pletely before attempting to install and operate the device! Keep these operating and installation instructions carefully. These operating instructions contain important safety and operating instructions for the use of the RF2K-S linear amplifier. When selling the device hand this document to the new owner. There are dangerous voltages inside the device! Before opening the device: ► Switch off the device by pressing the power switch O n/O f f (1) at the front of the device and wait until all cooling fans stop. ► Disconnect the power cable from the Power jack (9). Follow the instructions of a note to avoid damage to the device! Follow the instructions of a warning to avoid serious injury! Please use this linear amplifier only according to the instructions in this manual. The device is designed only for operation on frequencies of the ama - teur radio service. For legal operation you need a valid amateur radio license. 4 Operating and installation instructions RF-KIT Power Amplifier RF2K-S This device is NOT a TOY. It must not be handled by children or placed within reach of children or even been operated. The unit should only be opened or serviced by a qualified technician. This device generates high frequency energy. Use the device with due care regarding the system configuration. When connected to an antenna, this linear amplifier can generate high-frequency electromagnetic fields, which must be evaluated ac - cording to applicable national laws. All measures must be taken to ensure the necessary insulation regarding human exposure (observe minimum distances!). The radio frequency energy generated by this device may interact with some electronic devices such as pacemakers and defibrillators. Refer to the manufacturer instructions of a pacemaker or defibrillator for precautions in the vicinity of a radio frequency transmitter. Immediately stop an ongoing transmission if malfunction or interfe - rence with a pacemaker or defibrillator is suspected! DANGER - HIGH TENSION! NEVER connect an antenna or remove an antenna socket while the unit is transmitting! This can cause electric shock or burns! DANGER - HIGH TENSION! NEVER operate the device without properly mounted cover. This can cause electric shock or burns! DANGER - HIGH TENSION! NEVER apply mains voltage before the linear amplifier is Grounded. Touching the linear amplifier in this case can cause an electric shock! WARNING! NEVER operate the device with a mains voltage other than the recommen…
Text truncated - open the document above for the full version.
Federal Communications Commission 7435 Oakland Milts Road Columbia, MD 21046 FCC CONFIDENTIALITY FORM Ladies and Gentlemen: This letter is to comply with Sections 0.457 and 0.459 pertaining to confidential material. RF-KIT would like the following documents regarding this submission for FCC ID: 2AW84RF2K-S to be kept confidential. 1. Operational Description 2. Part list 3. Schematics 4. Tune up procedure The above material contains trade secrets or technical data, which would customarily be guarded from competitors. We do not want these documents to be accessible to the general public. Sincerely, RF-KIT Reinhard Foertsch F0023_FCC Confidentiality Form
A n n e x 2 t o Test Report # EMCC-170232ABA Page 1 of 3 Issue Date: 2020-11-12 EMCCons DR. RAŠEK GmbH & Co. KG Boelwiese 8 91320 Ebermannstadt Germany 170232ABA Telephone: +49 9194 7262-0 Telefax: +49 9194 7262-199 Mail: [email protected] Web: www.emcc.de Annex 2 to Test Report # EMCC-170232ABA, 2020-11-12 PHOTOGRAPHS OF EQUIPMENT UNDER TEST (EUT) EQUIPMENT UNDER TEST: Device: RF2K-S Serial Number: 02/201029 Application: Amplifier FCC ID: 2AW84RF2K-S Manufacturer: RF-KIT Address: Heuleithe 14 91322 Graefenberg GERMANY Phone: +49 9192 996689 Fax: - RELEVANT STANDARD(S): 47 CFR §§ 97.307, 97.317 A n n e x 2 t o Test Report # EMCC-170232ABA Page 2 of 3 Issue Date: 2020-11-12 Test of RF-KIT Amplifier RF2K-S to 47 CFR §§ 97.307, 97.317 © EMCCons DR. RAŠEK GmbH & Co. KG 170232ABA Photo A2-1: EUT, front Photo A2-2: EUT, back A n n e x 2 t o Test Report # EMCC-170232ABA Page 3 of 3 Issue Date: 2020-11-12 Test of RF-KIT Amplifier RF2K-S to 47 CFR §§ 97.307, 97.317 © EMCCons DR. RAŠEK GmbH & Co. KG 170232ABA Photo A2-3: EUT, back, detail view of label Photo A2-4: EUT, top
RF-KIT RF2K-S FCC Labeling The FCC label is located above the fan at the rear side of the RF2K-S just below the Manufacturer Product naming and Serial number.
tl EMEtr. OR,RAÉEK Test Report # EMCC-17023248A Page 1 of 1-2 lssue Date:2020-Il-L2 TEST REPORT # EMCC-17O232AB,A, 2020-11-12 This Test Report replaces Test Report # EllilCC-770232A8 dated 2O2O-70-73 EQUIPMENT UNDERTEST: Device: Serial Number: Application: FCC ID: Manufacturer: Address: RF2K-S 02t20L029 Amplifier 2AW84RF2K.S RF-KIT Heuleithe 14 91322 Graefenberg GERMANY +49 9192996689 Phone: Fax: RELEVANT STANDARD(S):47 CFR çç 97.307, 97.3L7 TEST REPORT PREPARED BY: Dominik Krueger EMCCONS DR. RASEK GMbH & CO. KG Boelwiese 8 91320 Ebermannstadt Germany Phone: +4991947262-0 Fax: +499L947262-L99 E-Mail: [email protected] TESTED: APPROVED: -D e !oi/,(^ Dominik Krueger Reinhard Sauerschell EMCCons On. n¡5¡f GmbH & Co. KG Boelwiese 8 9l-320 Ebermannstadt Germany ( DAKKS Telephone: Telefax: Mail: Web: +49 9194 7262-0 +49 91947262-L99 emc,[email protected] www.emcc.de Deutsche Akkreditierungsstelle D-Pt-12067-01-ß 1702324ßA Test Report # EMCC-170232ABA Page 2 of 12 Issue Date: 2020-11-12 Test of RF-KIT Amplifier RF2K-S to 47 CFR §§ 97.307, 97.317 © EMCCons DR. RAŠEK GmbH & Co. KG 170232ABA CONTENTS PAGE REVISION HISTORY 3 0 GENERAL INFORMATION 4 1 Purpose 4 1.1 Limits and Reservations 4 1.2 Test Location 4 1.3 Customer 4 1.4 Manufacturer 4 1.5 Dates and Test Location 5 1.6 Ordering Information 5 1.7 Climatic Conditions 5 1.8 PRODUCT DESCRIPTION 6 2 Equipment under Test (EUT) 6 2.1 Intended Use 6 2.2 EUT Peripherals/Simulators 7 2.3 Mode of Operation during Testing and Test Setup 7 2.4 Modifications Required for Compliance 7 2.5 SPURIOUS EMISSIONS & GAIN 8 3 Regulation 8 3.1 Test Equipment 9 3.2 Test Setup 9 3.3 Test Result 10 3.4 MEASUREMENT UNCERTAINTY 11 4 LIST OF ANNEXES 12 5 Test Report # EMCC-170232ABA Page 3 of 12 Issue Date: 2020-11-12 Test of RF-KIT Amplifier RF2K-S to 47 CFR §§ 97.307, 97.317 © EMCCons DR. RAŠEK GmbH & Co. KG 170232ABA REVISION HISTORY 0 Project number Issue date Chapter Description 170232AB 2020-10-13 n.a. Initial issue 170232ABA 2020-11-12 3.4 Measurement values for harmonics > 52 MHz were corrected. Foot note was added. Test Report # EMCC-170232ABA Page 4 of 12 Issue Date: 2020-11-12 Test of RF-KIT Amplifier RF2K-S to 47 CFR §§ 97.307, 97.317 © EMCCons DR. RAŠEK GmbH & Co. KG 170232ABA GENERAL INFORMATION 1 Purpose 1.1 The purpose of this report is to show compliance with the 47 CFR §97.307 and §97.317 requirements for the certification of external RF amplifiers operating in the amateur radio service. Limits and Reservations 1.2 The test results in this report apply only to the particular equipment under test (EUT) as declared in this report. This test report shall not be reproduced except in full without the written permission of EMCCons DR. RAŠEK GmbH & Co. KG. Document(s) and/or information, which were provided by the customer, can affect the validity of results. Test Location 1.3 Test Laboratory: EMCCons DR. RAŠEK GmbH & Co. KG Accreditation No.: D-PL-12067-01-04 FCC Test Firm Registration No.: 368753 Address of Labs I, II, III EMCCons DR. RAŠEK GmbH & Co. KG and Head Office: Boelwiese 8 91320 Ebermannstadt GERMANY Address of Labs IV and V: EMCCons DR. RAŠEK GmbH & Co. KG Stoernhofer Berg 15 91364 Unterleinleiter GERMANY Phone: +49 9194 7262-0 Fax: +49 9194 7262-199 E-Mail: [email protected] Web: www.emcc.de Customer 1.4 Company Name: RF-KIT Street: Heuleithe 14 City: 91322 Graefenberg Country: GERMANY Phone: +49 9192 996689 E-Mail: [email protected] Manufacturer 1.5 Company Name: RF-KIT Street: Heuleithe 14 City: 91322 Graefenberg Country: GERMANY Test Report # EMCC-170232ABA Page 5 of 12 Issue Date: 2020-11-12 Test of RF-KIT Amplifier RF2K-S to 47 CFR §§ 97.307, 97.317 © EMCCons DR. RAŠEK GmbH & Co. KG 170232ABA Dates and Test Location 1.6 Date of Receipt of EUT: 2020-09-23 Test Date: 2020-09-24 Test Location: Lab IV Ordering Information 1.7 Purchase Order: signed e-mail EMCC-170232AB, dated 2020-08-06 Climatic Conditions 1.8 Date Temperature [°C] Relative Humidity [%] Air Pressure [hPa] Lab Customer attended tests 2020-09-24 23 51 968 IV Mr Foertsch Test Report # EMCC-170232ABA Page 6 of 12 Issue Date: 2020-11-12 Test of RF-KIT Amplifier RF2K-S to 47 CFR §§ 97.307, 97.317 © EMCCons DR. RAŠEK GmbH & Co. KG 170232ABA PRODUCT DESCRIPTION 2 Equipment under Test (EUT) 2.1 EUT details given by the customer unless indicated on EUT. Trade name: RF2K-S Serial number: 02/201029 FCC ID 2AW84RF2K-S Firmware revision: G36C71 Hardware revision: V1.1 Application: Amplifier Power supply: 90/ 290 VAC 50/60Hz Voltage for testing: 230 VAC / 60 Hz Highest internally generated or used frequency: 5 GHz Amateur Radio bands: 160 m, 80 m, 60m, 40 m, 30 m, 20 m, 17 m, 15 m, 12 m, 10 m, 6 m TX between 1.8 MHz & 30 MHz and 50 – 54.2 MHz Output power: 1500 W Ports: TRX (Exciter input) ANT1 ANT2 ANT3 ANT4 PTT Power ON extern Power jack Ground connector Multifunction connector - 55 dB output CAT USB LAN Accessories delivered with EUT: Transceiver (with power supply), cable harness (see chapter 2.3) Variants: None Remarks: None For further information concerning port description see Annex 3. Intended Use 2.2 Amplifier for amateur radio service. Test Report # EMCC-170232ABA Page 7 of 12 Issue Date: 2020-11-12 Test of RF-KIT Amplifier RF2K-S to 47 CFR §§ 97.307, 97.317 © EMCCons DR. RAŠEK GmbH & Co. KG 170232ABA EUT Peripherals/Simulators 2.3 A Kennwood TS-2000 Transceiver was used as exciter. The complete exciter set-up was provided by the customer. Mode of Operation during Testing and Test Setup 2.4 The EUT was supplied with 230 V / 60 Hz AC and switched on. “ANT1” was connected to a dummy load. The input of the amplifier was set to a value which equals an output power of about 1500 W. Modifications Required for Compliance 2.5 None. Test Results Summary Summary of test results for the following EUT: Manufacturer: RF-KIT Device: RF2K-S Serial No: 02/201029 Requirement 47 CFR Section Report Section Result Spurious Emissions & Gain 97.307(d), 97.317(a) 4 Passed The customer has made the determinati…
Text truncated - open the document above for the full version.
A n n e x 1 t o Test Report # EMCC-170232ABA Page 1 of 2 Issue Date: 2020-11-12 EMCCons DR. RAŠEK GmbH & Co. KG Boelwiese 8 91320 Ebermannstadt Germany 170232ABA Telephone: +49 9194 7262-0 Telefax: +49 9194 7262-199 Mail: [email protected] Web: www.emcc.de Annex 1 to Test Report # EMCC-170232ABA, 2020-11-12 PHOTOGRAPHS OF TEST SET-UP EQUIPMENT UNDER TEST: Device: RF2K-S Serial Number: 02/201029 Application: Amplifier FCC ID: 2AW84RF2K-S Manufacturer: RF-KIT Address: Heuleithe 14 91322 Graefenberg GERMANY Phone: +49 9192 996689 Fax: - RELEVANT STANDARD(S): 47 CFR §§ 97.307, 97.317 A n n e x 1 t o Test Report # EMCC-170232ABA Page 2 of 2 Issue Date: 2020-11-12 Test of RF-KIT Amplifier RF2K-S to 47 CFR §§ 97.307, 97.317 © EMCCons DR. RAŠEK GmbH & Co. KG 170232ABA Photo A1-1: Conducted amplifier gain emissions measurement Photo A1-2: Conducted amplifier spurious emissions measurement
A n n e x 3 to Test Report # EMCC-170232ABA Page 1 of 1 Issue Date: 2020-11-12 EMCCons DR. RAŠEK GmbH & Co. KG Boelwiese 8 91320 Ebermannstadt Germany 170232ABA Telephone: +49 9194 7262-0 Telefax: +49 9194 7262-199 Mail: [email protected] Web: www.emcc.de Annex 3 to Test Report # EMCC-170232ABA, 2020-11-12 DESCRIPTION OF EQUIPMENT UNDER TEST (EUT), PORTS EQUIPMENT UNDER TEST: Device: RF2K-S Serial Number: 02/201029 Application: Amplifier FCC ID: 2AW84RF2K-S Manufacturer: RF-KIT Address: Heuleithe 14 91322 Graefenberg GERMANY Phone: +49 9192 996689 Fax: - RELEVANT STANDARD(S): 47 CFR §§ 97.307, 97.317 The following information was delivered by the customer: TRX 50 Ω impedance RF input ports from exciter ANT1 50 Ω antenna socket SO-239 (PL-259) ANT2 50 Ω antenna socket SO-239 (PL-259) ANT3 50 Ω antenna socket SO-239 (PL-259) ANT4 50 Ω antenna socket SO-239 (PL-259) PTT RCA connector for transmit/receive switching Power ON extern RCA connector for remote control (on at +12 VDC) Power jack AC input connector DB-15 connector Multifunction connector (BCD band data output) CAT USB USB 2.0 connector “CAT“ -55 dB output SMA connector for adaptive predistortion of the exciter signal along with SDR transceivers LAN RJ45 network connector
A n n e x 2 t o Test Report # EMCC-170232ABA Page 1 of 3 Issue Date: 2020-11-12 EMCCons DR. RAŠEK GmbH & Co. KG Boelwiese 8 91320 Ebermannstadt Germany 170232ABA Telephone: +49 9194 7262-0 Telefax: +49 9194 7262-199 Mail: [email protected] Web: www.emcc.de Annex 2 to Test Report # EMCC-170232ABA, 2020-11-12 PHOTOGRAPHS OF EQUIPMENT UNDER TEST (EUT) EQUIPMENT UNDER TEST: Device: RF2K-S Serial Number: 02/201029 Application: Amplifier FCC ID: 2AW84RF2K-S Manufacturer: RF-KIT Address: Heuleithe 14 91322 Graefenberg GERMANY Phone: +49 9192 996689 Fax: - RELEVANT STANDARD(S): 47 CFR §§ 97.307, 97.317 A n n e x 2 t o Test Report # EMCC-170232ABA Page 2 of 3 Issue Date: 2020-11-12 Test of RF-KIT Amplifier RF2K-S to 47 CFR §§ 97.307, 97.317 © EMCCons DR. RAŠEK GmbH & Co. KG 170232ABA Photo A2-1: EUT, front Photo A2-2: EUT, back A n n e x 2 t o Test Report # EMCC-170232ABA Page 3 of 3 Issue Date: 2020-11-12 Test of RF-KIT Amplifier RF2K-S to 47 CFR §§ 97.307, 97.317 © EMCCons DR. RAŠEK GmbH & Co. KG 170232ABA Photo A2-3: EUT, back, detail view of label Photo A2-4: EUT, top
A n n e x 1 t o Test Report # EMCC-170232ABA Page 1 of 2 Issue Date: 2020-11-12 EMCCons DR. RAŠEK GmbH & Co. KG Boelwiese 8 91320 Ebermannstadt Germany 170232ABA Telephone: +49 9194 7262-0 Telefax: +49 9194 7262-199 Mail: [email protected] Web: www.emcc.de Annex 1 to Test Report # EMCC-170232ABA, 2020-11-12 PHOTOGRAPHS OF TEST SET-UP EQUIPMENT UNDER TEST: Device: RF2K-S Serial Number: 02/201029 Application: Amplifier FCC ID: 2AW84RF2K-S Manufacturer: RF-KIT Address: Heuleithe 14 91322 Graefenberg GERMANY Phone: +49 9192 996689 Fax: - RELEVANT STANDARD(S): 47 CFR §§ 97.307, 97.317 A n n e x 1 t o Test Report # EMCC-170232ABA Page 2 of 2 Issue Date: 2020-11-12 Test of RF-KIT Amplifier RF2K-S to 47 CFR §§ 97.307, 97.317 © EMCCons DR. RAŠEK GmbH & Co. KG 170232ABA Photo A1-1: Conducted amplifier gain emissions measurement Photo A1-2: Conducted amplifier spurious emissions measurement
| # | Rule Parts | Frequency Range | Power Output | Emission |
|---|---|---|---|---|
| 1 | 97 | 1.8 MHz - 54 MHz | 1500 W | XXX |