  3. 2AW9W-MD50235P

2AW9W-MD50235PWIFI Smart Foot Masager

ZHEJIANG MONDIAL ELECTRONIC TECHNOLOGY CO., LTD
WIFI Smart Foot Masager - FCC ID 2AW9W-MD50235P - ZHEJIANG MONDIAL ELECTRONIC TECHNOLOGY CO., LTD
Click to zoom

Application Details

Equipment Class
DTS - Digital Transmission System
Date of Grant
Aug 31, 2020
Application Purpose
Original Equipment
Date of Application
Aug 31, 2020
Equipment Note
WIFI Smart Foot Masager
Frequency Range
2412.00000000 - 2462.00000000
Company
ZHEJIANG MONDIAL ELECTRONIC TECHNOLOGY CO., LTD
Country
China

Documents & Files

Select a file to view

Users Manual

↗

Attestation Statements

↗

Cover Letter(s)

↗
↗

External Photos

↗

ID Label/Location Info

↗

Internal Photos

↗

RF Exposure Info

↗

Test Report

Test Setup Photos

↗

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

Users Manual

I I Warranty(1-�臼『-Limited) The manufacturer's warranty is void under伽e following circums回n帽S but not limited to : Improper or inad伺ua1恼maintenance or m。d闭目1tion. Accident, misuse, abu se, contamination, or other external 回us臼. The use of uns 阳cified adapter and aα:essories. Loss or damage in transit. Damages that occu『as a result of one's failure to follow伽e inst阳clions. This warranty d四s not apply to expendable or consumable pa同s and does not extend to any product衍。m which the serial number has been removed. 21 This device complies with part 1 5 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesire d operation. Any Changes or modifications not expressly approved by the party responsible for compliance could void the user's authority to operate the e quipment. Note: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or telev ision reception, which can be determined by turning the e quipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures: -Reorient or relocate the receiving antenna. -Increase the separation between the equipment and receiver. -Co nnect the e quipment into an outlet on a circuit different from that to which the receiver is connected. -Co nsult the dealer or an experienced radio /TV technician for help.

Attestation Statements

ZHEJIANG MONDIAL ELECTRONIC TECHNOLOGY CO., LTD Model Difference Product Name: WIFI Smart Foot Masager Model Number: MD-50235P, RF-FM059HS FCC Identifier: 2AW9W-MD50235P All the models are the same circuit and RF module, except the model names and outlook color. Regards Sincerely Client’s signature Client’s name / title : Vic Pu / Manager Contact information / address: NO.15 CHAOYANG ROAD, HAIYOU SUBDISTRICT, SANMEN COUNTY, TAIZHOU CITY,317100, ZHEJIANG, CHINA

Cover Letter(s)

ZHEJIANG MONDIAL ELECTRONIC TECHNOLOGY CO., LTD 1/1 Letter of Authorization Company: ZHEJIANG MONDIAL ELECTRONIC TECHNOLOGY CO., LTD Address: NO.15 CHAOYANG ROAD, HAIYOU SUBDISTRICT, SANMEN COUNTY, TAIZHOU CITY,317100, ZHEJIANG, CHINA Product Name: WIFI Smart Foot Masager Model Number: MD-50235P, RF-FM059HS FCC Identifier: 2AW9W-MD50235P We authorize LGAI Technological Center S.A., Ronda de la Font del Carme, s/n, 08193 Bellaterra, Spain, to act on our behalf on all matters concerning the above named equipment. Any individual within LGAI Technological Center S.A. is authorized to act on our behalf and take action on the application. We declare that authorize LGAI Technological Center S.A., Ronda de la Font del Carme, s/n, 08193 Bellaterra, Spain, is allowed to forward all information related to the approval project to the Federal Communication Commission and to discuss any issues concerning the approval application. Any and all acts carried out by LGAI Technological Center S.A. on our behalf shall have the same effect as acts of our own. Name: Vic Pu Date: 2020-08-10 Title: Manager Signature of applicant:

Cover Letter(s)

ZHEJIANG MONDIAL ELECTRONIC TECHNOLOGY CO., LTD 1/1 Office of Engineering Technology Federal Communications Commission 7435 Oakland Mills Road Columbia, MD 21046 Date: 2020-08-10 Subject: Request for Confidentiality FCC ID: 2AW9W-MD50235P To Whom It May Concern, Pursuant to the provisions of Sections 0.457 and 0.459 of Commission's rules (47CFR0.457, 0.459), we are requesting the Commission to withhold the following attachment(s) as confidential document from public disclosure. Exhibits Long-Term Confidentiality Short-Term Confidentiality NOTE 2 ID Label/Location No No Attestation Statement No No External Photos No ☐ Block Diagram ☒ ☐ Schematics ☒ ☐ Test Report No No Test Setup Photos No ☐ User’s Manual No ☐ Internal Photos No ☐ Parts List / Tune Up ☒ ☐ RF Exposure Info No No Operational Description ☒ ☐ Cover Letter(s) No No SDR Software / Security Info ☐ No NOTE 1: Long-Term Confidentiality may be permitted under special conditions (See II. LONG-TERM CONFIDENTIALITY, Section 3 of KDB 726920, use last in force) NOTE 2: Short-Term Confidentiality can be requested for a maximum of 180 days from the date of the grant. Above mentioned document contains detailed system and equipment description are considered as proprietary information in operation of the equipment. The public disclosure of above documents might be harmful to our company and would give competitor an unfair advantage in the market. It is our understanding that all measurement test reports, FCC ID label format and correspondent during certification review process cannot be granted as confidential documents and those information will be available for public review once the grant of equipment authorization is issued. Sincerely, Signature: Name: Vic Pu Title: Manager

ID Label/Location Info

Size:65*51mm M/N: MD-50235P FCC ID: 2AW9W-MD50235P This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions:(1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. Label location

Internal Photos

antenna location WiFi chipset

RF Exposure Info

FCC ID: 2AW9W-MD50235P RF Exposure Evaluation According to KDB 447498 and part 2.1093,Unless specifically required by the published RF exposure KDB procedures, standalone 1-g head or body and 10-g extremity SAR evaluation for general population exposure conditions, by measurement or numerical simulation, is not required when the corresponding SAR Test Exclusion Threshold condition(s), listed below, is (are) satisfied. For 100 MHz to 6 GHz and test separation distances ≤ 50 mm, the 1-g and 10-g SAR test exclusion thresholds are determined by the following: [(max. power of channel, including tune-up tolerance, mW) / (min. test separation distance, mm)] · [√f (GHz) ] ≤ 3.0 for 1-g SAR, and ≤ 7.5 for 10-g extremity SAR, where f (GHz) is the RF channel transmit frequency in GHz Power and distance are rounded to the nearest mW and mm before calculation The result is rounded to one decimal place for comparison Here, For Wifi Mode Max Power(dBm) Max Power(mW) Frequency(MHz) Min. distance(mm) Calc. thresholds limit 802.11b 11.31 13.52 2412 5 4.20 7.5 10.49 11.19 2437 5 3.50 7.5 9.83 9.62 2462 5 3.02 7.5 So a SAR test is not required

Test Setup Photos

Radiated Emission Conducted Emissions

Contact Information

Applicant

Vic Pu(Manager)
[email protected]86-18575163065Fax: 86-18575163065

Technical Contact

Global United Technology Services Co. Ltd.robinson lo
[email protected]86-0-755-2779-8480

Shenzhen · China

Test Firm

Global United Technology Services Co. Ltd.Robinson Lo
[email protected]86-0-755-2779-8480Fax: 86-0-755-27798960

Technical Specifications

#Rule PartsFrequency RangePower Output
115C2.41 GHz - 2.46 GHz13.52 mW
Confidentiality
Long Term
Grant Notes
Output power listed is conducted.