FCCID.CO- FCC ID Database
HomeCompaniesEquipment ClassesSearch

© 2026 FCC ID Database. All rights reserved.

AboutContactData sourced from FCC public records
  1. Home/
  2. Icarsoft Technology Inc./
  3. 2AWD8-CRMAX

2AWD8-CRMAXCar Diagnostic Tool

Icarsoft Technology Inc.
Car Diagnostic Tool - FCC ID 2AWD8-CRMAX - Icarsoft Technology Inc.
Click to zoom

Application Details

Equipment Class
DTS - Digital Transmission System
Date of Grant
Aug 06, 2020
Application Purpose
Original Equipment
Date of Application
Aug 06, 2020
Equipment Note
Car Diagnostic Tool
Frequency Range
2402.00000000 - 2480.00000000
Company
Icarsoft Technology Inc.
Country
United States

Documents & Files

Select a file to view

Users Manual

↗

Attestation Statements

↗

Cover Letter(s)

↗
↗

External Photos

↗

ID Label/Location Info

↗

Internal Photos

↗

RF Exposure Info

↗
↗
↗
↗
↗

Test Report

↗
↗

Test Setup Photos

↗

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

Users Manual

I Trademarks iCarsoft,CRMaxandCRMAXBTaretrademarksofiCarsoft IntelligentTechnologyCorp.,Ltd.,registeredintheUnitedStates andothercountries.Allothermarksaretrademarksorregistered trademarksoftheirrespectiveholders. CopyrightInformation Nopartofthismanualmaybereproduced,storedinaretrieval systemortransmitted,inanyformorbyanymeans,electronic, mechanical,photocopying,recording,orotherwisewithouttheprior writtenpermissionofiCarsoft. DisclaimerofWarrantiesandLimitationofLiabilities Allinformation,specificationsandillustrationsinthismanualare basedonthelatestinformationavailableatthetimeofprinting. iCarsoftreservestherighttomakechangesatanytimewithout notice.Whileinformationofthismanualhasbeencarefullychecked foraccuracy,noguaranteeisgivenforthecompletenessand correctnessofthecontents,includingbutnotlimitedtotheproduct specifications,functions,andillustrations. iCarsoftwillnotbeliableforanydirect,special,incidental,indirect damagesoranyeconomicconsequentialdamages(includingthe lossofprofits). IMPORTANT Beforeoperatingormaintainingthisunit,pleasereadthismanual carefully,payingextraattentiontothesafetywarningsand precautions. ForServicesandSupport Http://www.icarsoft.us Http://www.icarsoft.com [email protected] Fortechnicalassistanceinallothermarkets,pleasecontactyour localsellingagent. II SafetyInformation Foryourownsafetyandthesafetyofothers,andtopreventdamage tothedeviceandvehiclesuponwhichitisused,itisimportantthat thesafetyinstructionspresentedthroughoutthismanualbereadand understoodbyallpersonsoperatingorcomingintocontactwiththe device. Therearevariousprocedures,techniques,tools,andpartsfor servicingvehicles,aswellasintheskillofthepersondoingthework. Becauseofthevastnumberoftestapplicationsandvariationsinthe productsthatcanbetestedwiththisequipment,wecannotpossibly anticipateorprovideadviceorsafetymessagestocoverevery circumstance.Itistheautomotivetechnician’sresponsibilitytobe knowledgeableofthesystembeingtested.Itiscrucialtouseproper servicemethodsandtestprocedures.Itisessentialtoperformtests inanappropriateandacceptablemannerthatdoesnotendanger yoursafety,thesafetyofothersintheworkarea,thedevicebeing used,orthevehiclebeingtested. Beforeusingthedevice,alwaysrefertoandfollowthesafety messagesandapplicabletestproceduresprovidedbythe manufacturerofthevehicleorequipmentbeingtested.Usethe deviceonlyasdescribedinthismanual.Read,understand,and followallsafetymessagesandinstructionsinthismanual. SafetyMessages Safetymessagesareprovidedtohelppreventpersonalinjuryand equipmentdamage.Allsafetymessagesareintroducedbyasignal wordindicatingthehazardlevel. DANGER Indicatesanimminentlyhazardoussituationwhich,ifnotavoided, willresultindeathorseriousinjurytotheoperatorortobystanders. WARNING III Indicatesapotentiallyhazardoussituationwhich,ifnotavoided, couldresultindeathorseriousinjurytotheoperatororto bystanders. SafetyInstructions ThesafetymessageshereincoversituationsiCarsoftisawareof. iCarsoftcannotknow,evaluateoradviseyouastoallofthepossible hazards.Youmustbecertainthatanyconditionorserviceprocedure encountereddoesnotjeopardizeyourpersonalsafety. DANGER Whenanengineisoperating,keeptheserviceareaWELL VENTILATEDorattachabuildingexhaustremovalsystemtothe engineexhaustsystem.Enginesproducecarbonmonoxide,an odorless,poisonousgasthatcausesslowerreactiontimeandcan leadtoseriouspersonalinjuryorlossoflife. SAFETYWARNINGS Alwaysperformautomotivetestinginasafeenvironment. WearsafetyeyeprotectionthatmeetsANSIstandards. Keepclothing,hair,hands,tools,testequipment,etc.awayfrom allmovingorhotengineparts. Operatethevehicleinawellventilatedworkarea,forexhaust gasesarepoisonous. PutthetransmissioninPARK(forautomatictransmission)or NEUTRAL(formanualtransmission)andmakesuretheparking brakeisengaged. Putblocksinfrontofthedrivewheelsandneverleavethe vehicleunattendedwhiletesting. Beextracautiouswhenworkingaroundtheignitioncoil, distributorcap,ignitionwiresandsparkplugs.These componentscreatehazardousvoltageswhentheengineis running. IV Keepafireextinguishersuitableforgasoline,chemical,and electricalfiresnearby. Donotconnectordisconnectanytestequipmentwhilethe ignitionisonortheengineisrunning. Keepthetestequipmentdry,clean,freefromoil,wateror grease.Useamilddetergentonacleanclothtocleanthe outsideoftheequipmentasnecessary. Donotdrivethevehicleandoperatethetestequipmentatthe sametime.Anydistractionmaycauseanaccident. Refertotheservicemanualforthevehiclebeingservicedand adheretoalldiagnosticproceduresandprecautions.Failureto dosomayresultinpersonalinjuryordamagetothetest equipment. Toavoiddamagingthetestequipmentorgeneratingfalsedata, makesurethevehiclebatteryisfullychargedandthe connectiontothevehicleDLCiscleanandsecure. Donotplacethetestequipmentonthedistributorofthevehicle. Strongelector-magneticinterferencecandamagethe equipment. V CONTENTS 1USINGTHISMANUAL .......................................................................... 1 1.1CONVENTIONS ................................................................................ 1 1.1.1BoldText ............................................................................1 1.1.2NotesandImportantMessages.....................................1 1.1.3Hyperlink ............................................................................ 2 1.1.4Illustrations ........................................................................ 2 2GENERALINTRODUCTION ........................................................... 3 2.1CRMAXDISPLAYTABLET ............................................................... 3 2.1.1FunctionalDescription .......................................................... 3 2.1.2PowerSources.......................................................................4 2.1.3TechnicalSpecifications.........................................................5 2.2ACCESSORYKIT ............................................................................... 7 2.2.1MainCable ............................................................................ 7 2.2.2OtherAccessori…

Text truncated - open the document above for the full version.

Attestation Statements

lcarso仕TechnologyInc. Date: 2020-07-9 To: Federal Communications Commission 7435 Oakland Mills Road Columbia, MD FC C ID: 2A WD8-CRMAX To Whom It May Concern: This letter is to ascertain that lc arsoft Technology Inc. EUT: Car Diagnostic Tool MODEL No.: CR MAX H as been the units used for conducting FCC compliance testing, the SDoC part will be tested by EMTEK (SHENZHEN) CO., LTD. If you have any question or con ems, pis. contact us. s;g� t "re �w Cynthia Brook/ manager Icarsoft Technology Inc.

External Photos

TRFNO.FCCPage1of4ReportNo.:ES200311053WVer.1.0 EUTEXTERNALPHOTOGRAPHS EUTView1 EUTView2 TRFNO.FCCPage2of4ReportNo.:ES200311053WVer.1.0 EUTView3 EUTView4 TRFNO.FCCPage3of4ReportNo.:ES200311053WVer.1.0 EUTView5 EUTView6 TRFNO.FCCPage4of4ReportNo.:ES200311053WVer.1.0 EUTView7 ----------------Theend----------------

ID Label/Location Info

Labellocation

Internal Photos

TRFNO.FCCPage1of4ReportNo.:ES200311053WVer.1.0 EUTINTERNALPHOTOGRAPHS EUTHousingandBoardView1 SolderBoard-ComponentView2 Ant TRFNO.FCCPage2of4ReportNo.:ES200311053WVer.1.0 SolderBoard-ComponentView3 SolderBoard-ComponentView4 TRFNO.FCCPage3of4ReportNo.:ES200311053WVer.1.0 SolderBoard-ComponentView5 SolderBoard-ComponentView6 TRFNO.FCCPage4of4ReportNo.:ES200311053WVer.1.0 - ----------------Theend----------------

RF Exposure Info

Test Laboratory: Shenzhen EMTEK Co.,Ltd.Date: 2020/6/1 System Check_B2450 DUT: Dipole 2450 MHz; Type:D2450V2; SN:835 Communication System: CW; Frequency: 2450 MHz;Duty Cycle: 1:1 Medium: B2450 Medium parameters used: f = 2450 MHz; σ = 2.026 S/m; ε r = 53.063; ρ = 1000 kg/m 3 Ambient Temperature:22.5 °C; Liquid Temperature:21.6 °C DASY5 Configuration: - Probe: EX3DV4 - SN3970; ConvF(8.08, 8.08, 8.08); Calibrated: 2020/2/8; - Sensor-Surface: 2mm (Mechanical Surface Detection) - Electronics: DAE4 Sn1418; Calibrated: 2020/1/8 - Phantom: ELI v5.0; Type: QDOVA002AA; Serial: TP:1231 - Measurement SW: DASY52, Version 52.8 (7); SEMCAD X Version 14.6.10 (7164) Pin=250mW/Area Scan (41x51x1): Interpolated grid: dx=2.000 mm, dy=2.000 mm Maximum value of SAR (interpolated) = 23.6 W/kg Pin=250mW/Zoom Scan (5x5x7)/Cube 0: Measurement grid: dx=8mm, dy=8mm, dz=5mm Reference Value = 102.4 V/m; Power Drift = 0.14 dB Peak SAR (extrapolated) = 28.1 W/kg SAR(1 g) = 12.9 W/kg; SAR(10 g) = 6.02 W/kg Maximum value of SAR (measured) = 21.7 W/kg

RF Exposure Info

Test Laboratory: Shenzhen EMTEK Co.,Ltd.Date: 2020/6/1 802.11b-back-ch1 DUT: CR MAX Communication System: 802.11b; Frequency: 2462 MHz;Duty Cycle: 1:1 Medium: B2450 Medium parameters used: f = 2412 MHz; σ = 1.969 S/m; ε r = 53.144; ρ = 1000 kg/m 3 Ambient Temperature:22.5 °C; Liquid Temperature:21.6 °C DASY5 Configuration: - Probe: EX3DV4 - SN3970; ConvF(8.08, 8.08, 8.08); Calibrated: 2020/2/8; - Sensor-Surface: 4mm (Mechanical Surface Detection) - Electronics: DAE4 Sn1418; Calibrated: 2020/1/8 - Phantom: ELI v5.0; Type: QDOVA002AA; Serial: TP:1231 - Measurement SW: DASY52, Version 52.8 (7); SEMCAD X Version 14.6.10 (7164) Body Back/Area Scan (201x281x1): Interpolated grid: dx=1.000 mm, dy=1.000 mm Maximum value of SAR (interpolated) = 0.323 W/kg Body Back/Zoom Scan (7x7x7)/Cube 0: Measurement grid: dx=5mm, dy=5mm, dz=5mm Reference Value = 31.13 V/m; Power Drift = -0.05 dB Peak SAR (extrapolated) = 0.344 W/kg SAR(1 g) = 0.234 W/kg; SAR(10 g) = 0.143 W/kg Maximum value of SAR (measured) = 0.287 W/kg

RF Exposure Info

FCCSARTestReport ReportNo.ES200428046W03Page 1 of 2 Ver.1.0 <PhotographsofEUT> FCCSARTestReport ReportNo.ES200428046W03Page 2 of 2 Ver.1.0 <PhotographsofSARSetup> RearFace0cmGapTopFace0cmGap LeftSide0cmGap

RF Exposure Info

FCCSARTestReport ReportNo.ES2000428046W03Page 1 of 47 Ver.1.0 FCCSARTestReport ReportNo.:ES200428046W03 Applicant:IcarsoftTechnologyInc. Address:1629KSt.Suite300N.W.WashingtonD.C.,20006UnitedStates. Product:CarDiagnosticTool FCCID:2AWD8-CRMAX Brand:iCarsoft ModelNo.:CRMAX Standards:FCC47CFRPart2(2.1093)/IEEEC95.1:1992/IEEE1528:2013 KDB865664D01v01r04/KDB865664D02v01r02 KDB248227D01v02r02/KDB447498D01v06/KDB616217D04v01r02 SampleReceivedDate:May29,2020 DateofTesting:June01,2020 CERTIFICATION:TheaboveequipmenthavebeentestedbyEMTEK(SHENZHEN)CO.,LTD.Building69, MajialongIndustryZone,NanshanDistrict,Shenzhen,Guangdong,China,andfoundcompliancewiththe requirementoftheabovestandards.Thetestrecord,dataevaluation&EquipmentUnderTest(EUT)configurations representedhereinaretrueandaccurateaccountsofthemeasurementsofthesample’sSARcharacteristicsunder theconditionsspecifiedinthisreport.Itshouldnotbereproducedexceptinfull,withoutthewrittenapprovalofour laboratory.Theclientshouldnotuseittoclaimproductcertification,approval,orendorsementbyA2LAorany governmentagencies. Preparedby: LanceLi/Editor Reviewer: JoeXia/Supervisor Approve&AuthorizedSigner: LisaWang/Manager $二维码$ FCCSARTestReport ReportNo.ES2000428046W03Page 2 of 47 Ver.1.0 Thisreportisforyourexclusiveuse.Anycopyingorreplicationofthisreporttoorforanyotherpersonorentity,oruseofournameortrademark,ispermittedonly withourpriorwrittenpermission.Thisreportsetsforthourfindingssolelywithrespecttothetestsamplesidentifiedherein.Theresultssetforthinthisreportare notindicativeorrepresentativeofthequalityorcharacteristicsofthelotfromwhichatestsamplewastakenoranysimilaroridenticalproductunlessspecifically andexpresslynoted.Ourreportincludesallofthetestsrequestedbyyouandtheresultsthereofbasedupontheinformationthatyouprovidedtous.Youhave60 daysfromdateofissuanceofthisreporttonotifyusofanymaterialerrororomissioncausedbyournegligence,provided,however,thatsuchnoticeshallbein writingandshallspecificallyaddresstheissueyouwishtoraise.Afailuretoraisesuchissuewithintheprescribedtimeshallconstituteyourunqualifiedacceptance ofthecompletenessofthisreport,thetestsconductedandthecorrectnessofthereportcontents.Unlessspecificmention,theuncertaintyofmeasurementhas beenexplicitlytakenintoaccounttodeclarethecomplianceornon-compliancetothespecification. FCCSARTestReport ReportNo.ES2000428046W03Page 3 of 47 Ver.1.0 TableofContents ReleaseControlRecord .................................................................................................................................................................................... 5 SummaryofMaximumSARValue................................................................................................................................................................6 DescriptionofEquipmentUnderTest ......................................................................................................................................................... 7 AC120V,60Hz....................................................................................................................................................................................................7 DC3.7frominternalbattery ............................................................................................................................................................................ 7 SARMeasurementSystem.............................................................................................................................................................................8 3.1DefinitionofSpecificAbsorptionRate(SAR) ............................................................................................................................... 8 3.2SPEAGDASYSystem...................................................................................................................................................................8 3.2.1Robot ..................................................................................................................................................................................... 9 3.2.2Probes.................................................................................................................................................................................10 3.2.3DataAcquisitionElectronics(DAE) ................................................................................................................................. 11 3.2.4Phantoms............................................................................................................................................................................12 3.2.5DeviceHolder ..................................................................................................................................................................... 13 3.2.6SystemValidationDipoles................................................................................................................................................13 3.2.7TissueSimulatingLiquids ................................................................................................................................................. 14 3.3SARSystemVerification..............................................................................................................................................................19 3.4SARMeasurementProcedure .................................................................................................................................................... 20 3.4.1Area&ZoomScanProcedure.........................................................................................................................................20 3.4.2VolumeScanProcedure .................................................................................................................................................... 21 3.4.3PowerDriftMonitoring.....................................................................…

Text truncated - open the document above for the full version.

Test Report

ReportNo.ES200428046W01Page1of44Ver.1.0 TESTREPORT ProductName:CarDiagnosticTool ModelNumber:CRMAX FCCID:2AWD8-CRMAX Preparedfor:IcarsoftTechnologyInc. Address:1629KSt.Suite300N.W.WashingtonD.C.,20006United States. Preparedby:EMTEK(SHENZHEN)CO.,LTD. Address:Building69,MajialongIndustryZone,NanshanDistrict, Shenzhen,Guangdong,China Tel:(0755)26954280 Fax:(0755)26954282 ReportNumber:ES200428046W01 Date(s)ofTests:May19,2020toJune21,2020 Dateofissue:June22,2020 $ 二维码 $ ReportNo.ES200428046W01Page2of44Ver.1.0 TableofContents 1TESTRESULTCERTIFICATION.................................................................................................................3 2EUTTECHNICALDESCRIPTION...............................................................................................................4 3SUMMARYOFTESTRESULT......................................................................................................................5 4TESTMETHODOLOGY.................................................................................................................................6 4.1GENERALDESCRIPTIONOFAPPLIEDSTANDARDS.......................................................................6 4.2MEASUREMENTEQUIPMENTUSED...................................................................................................6 4.3DESCRIPTIONOFTESTMODES...........................................................................................................7 5FACILITIESANDACCREDITATIONS........................................................................................................8 5.1FACILITIES................................................................................................................................................8 5.2LABORATORYACCREDITATIONSANDLISTINGS............................................................................8 6TESTSYSTEMUNCERTAINTY...................................................................................................................9 7SETUPOFEQUIPMENTUNDERTEST....................................................................................................10 7.1RADIOFREQUENCYTESTSETUP1...................................................................................................10 7.2RADIOFREQUENCYTESTSETUP2...................................................................................................10 7.3CONDUCTEDEMISSIONTESTSETUP...............................................................................................12 7.4BLOCKDIAGRAMCONFIGURATIONOFTESTSYSTEM...............................................................13 7.5SUPPORTEQUIPMENT..........................................................................................................................13 8TESTREQUIREMENTS...............................................................................................................................14 8.1DTS6DBBANDWIDTH.........................................................................................................................14 8.2MAXIMUMPEAKCONDUCTEDOUTPUTPOWER..........................................................................17 8.3MAXIMUMPOWERSPECTRALDENSITY........................................................................................20 8.4UNWANTEDEMISSIONSINNON-RESTRICTEDFREQUENCYBANDS......................................23 8.5RADIATEDSPURIOUSEMISSION.......................................................................................................28 8.6CONDUCTEDEMISSIONSTEST..........................................................................................................40 8.7ANTENNAAPPLICATION.....................................................................................................................43 ReportNo.ES200428046W01Page3of44Ver.1.0 1TESTRESULTCERTIFICATION Applicant:IcarsoftTechnologyInc. Address:1629KSt.Suite300N.W.WashingtonD.C.,20006UnitedStates. Manufacturer:ShenzhenBonorTechnologiesCo.Ltd Address: 6thfloorofSilverStarTechnologyBuilding,No.1301,GuanguangRoad, GuanlanStreet,LonghuanewDistrict,Shenzhen. EUT: CarDiagnosticTool ModelName: CRMAX Trademark: iCarsoft MeasurementProcedureUsed: APPLICABLESTANDARDS STANDARDTESTRESULT FCC47CFRPart2,SubpartJ FCC47CFRPart15,SubpartC PASS TheaboveequipmentwastestedbyEMTEK(SHENZHEN)CO.,LTD.Thetestdata,dataevaluation,test procedures,andequipmentconfigurationsshowninthisreportweremadeinaccordancewiththe proceduresgiveninANSIC63.10(2013)andtheenergyemittedbythesampleEUTtestedasdescribed inthisreportisincompliancewiththerequirementsofFCCRulesPart2andPart15.247 Thetestresultsofthisreportrelateonlytothetestedsampleidentifiedinthisreport DateofTest:May19,2020toJune21,2020 Preparedby: MillChen/Editor Reviewer: SewenGuo/Supervisor Approve&AuthorizedSigner: LisaWang / Manager ReportNo.ES200428046W01Page4of44Ver.1.0 2EUTTECHNICALDESCRIPTION ProductCarDiagnosticTool ModelNumberCRMAX DataRate:1MbpsforGFSKmodulation Modulation:GFSK OperatingFrequencyRange:2402-2480MHz NumberofChannels:40ChannelsforBluetoothDTS; TransmitPowerMax:5.77dBm AntennaType:FPCAntenna AntennaGain:2.15dBi Powersupply AC120V,60Hz DC3.7frominternalbattery Note:formoredetails,pleaserefertotheUser’smanualoftheEUT. ReportNo.ES200428046W01Page5of44Ver.1.0 3SUMMARYOFTESTRESULT FCCPartClauseTestParameterVerdictRemark 15.247(a)(2)DTS(6dB)BandwidthPASS 15.247(b)(3)MaximumPeakConductedOutputPowerPASS 15.247(e)MaximumPowerSpectralDensityLevelPASS 15.247(d)UnwantedEmissionIntoNon-Restricted FrequencyBands PASS 15.247(d) 15.209 UnwantedEmissionIntoRestrictedFrequency Bands(conducted) PASS 15.247(d) 15.209 RadiatedSpuriousEmissionPASS 15.207ConductedEmissionTestPASS 15.247(b)AntennaApplicationPASS NOTE1:N/A(NotApplicable) NOTE2:AccordingtoFCCOETKDB558074,thereportuseradiated measurementsintherestrictedfrequencybands.Inaddition,theradiated testisalsoperformedtoensuretheemissionsemanatingfromthedevice cabinetalsocomplywiththeapplicablelimits. RELATEDSUBMITTAL(S)/GRANT(S): T…

Text truncated - open the document above for the full version.

Test Report

ReportNo.ES200428046W02Page1of50Ver.1.0 TESTREPORT ProductName:CarDiagnosticTool ModelNumber:CRMAX FCCID:2AWD8-CRMAX Preparedfor:IcarsoftTechnologyInc. Address:1629KSt.Suite300N.W.WashingtonD.C.,20006United States. Preparedby:EMTEK(SHENZHEN)CO.,LTD. Address:Building69,MajialongIndustryZone,NanshanDistrict, Shenzhen,Guangdong,China Tel:(0755)26954280 Fax:(0755)26954282 ReportNumber:ES200428046W02 Date(s)ofTests:May19,2020toJune21,2020 Dateofissue:June22,2020 $二维码$ ReportNo.ES200428046W02Page2of50Ver.1.0 TABLEOFCONTENTS 1TESTRESULTCERTIFICATION........................................................................................................................3 2EUTTECHNICALDESCRIPTION......................................................................................................................4 3SUMMARYOFTESTRESULT............................................................................................................................5 4TESTMETHODOLOGY.......................................................................................................................................6 4.1GENERALDESCRIPTIONOFAPPLIEDSTANDARDS.............................................................................6 4.2MEASUREMENTEQUIPMENTUSED.........................................................................................................6 4.3DESCRIPTIONOFTESTMODES.................................................................................................................7 5FACILITIESANDACCREDITATIONS..............................................................................................................8 5.1FACILITIES......................................................................................................................................................8 5.2LABORATORYACCREDITATIONSANDLISTINGS.................................................................................8 6TESTSYSTEMUNCERTAINTY..........................................................................................................................9 7SETUPOFEQUIPMENTUNDERTEST..........................................................................................................10 7.1RADIOFREQUENCYTESTSETUP1.........................................................................................................10 7.2RADIOFREQUENCYTESTSETUP2.........................................................................................................10 7.3CONDUCTEDEMISSIONTESTSETUP.....................................................................................................11 7.4BLOCKDIAGRAMCONFIGURATIONOFTESTSYSTEM....................................................................12 7.5SUPPORTEQUIPMENT...............................................................................................................................12 8TESTREQUIREMENTS.....................................................................................................................................13 8.1DTS(6DB)BANDWIDTH............................................................................................................................13 8.2MAXIMUMPEAKCONDUCTEDOUTPUTPOWER...............................................................................20 8.3MAXIMUMPOWERSPECTRALDENSITY..............................................................................................22 8.4UNWANTEDEMISSIONSINNON-RESTRICTEDFREQUENCYBANDS............................................29 8.5RADIATEDSPURIOUSEMISSION............................................................................................................34 8.6CONDUCTEDEMISSIONSTEST...............................................................................................................46 8.7ANTENNAAPPLICATION...........................................................................................................................49 ReportNo.ES200428046W02Page3of50Ver.1.0 1TESTRESULTCERTIFICATION Applicant:IcarsoftTechnologyInc. Address:1629KSt.Suite300N.W.WashingtonD.C.,20006UnitedStates. Manufacturer:ShenzhenBonorTechnologiesCo.Ltd Address: 6thfloorofSilverStarTechnologyBuilding,No.1301,GuanguangRoad, GuanlanStreet,LonghuanewDistrict,Shenzhen. EUT: CarDiagnosticTool ModelName: CRMAX Trademark: iCarsoft MeasurementProcedureUsed: APPLICABLESTANDARDS STANDARDTESTRESULT FCC47CFRPart2,SubpartJ FCC47CFRPart15,SubpartC PASS TheaboveequipmentwastestedbyEMTEK(SHENZHEN)CO.,LTD.Thetestdata,dataevaluation, testprocedures,andequipmentconfigurationsshowninthisreportweremadeinaccordancewiththe proceduresgiveninANSIC63.10(2013)andtheenergyemittedbythesampleEUTtestedasdescribed inthisreportisincompliancewiththerequirementsofFCCRulesPart2andPart15.247 Thetestresultsofthisreportrelateonlytothetestedsampleidentifiedinthisreport. DateofTest:May19,2020toJune21,2020 Preparedby: MillChen/Editor Reviewer: SewenGuo/Supervisor Approve&AuthorizedSigner: LisaWang / Manager ReportNo.ES200428046W02Page4of50Ver.1.0 2EUTTECHNICALDESCRIPTION Note:formoredetails,pleaserefertotheUser’smanualoftheEUT. CharacteristicsDescription ProductCarDiagnosticTool ModelNumberCRMAX IEEE802.11WLAN ModeSupported 802.11b 802.11g 802.11n(20MHzchannelbandwidth) 802.11n(40MHzchannelbandwidth) DataRate 802.11b:1,2,5.5,11Mbps; 802.11g:6,9,12,18,24,36,48,54Mbps; 802.11n(HT20):upto144.4Mbps; Modulation DSSSwithDBPSK/DQPSK/CCKfor802.11b; OFDMwithBPSK/QPSK/16QAM/64QAMfor802.11g/n; OperatingFrequency Range 2412-2462MHzfor802.11b/g/n(HT20); 2422-2452MHzfor802.11n(HT40); NumberofChannels 11channelsfor802.11b/gn(HT20); 7Channelsfor802.11n(HT40); TransmitPowerMax20.51dBm SmartsystemSISOfor802.11b/g/n; AntennaTypeFPCAntenna AntennaGain2.15dBi Powersupply AC120V,60Hz DC3.7frominternalbattery ReportNo.ES200428046W02Page5of50Ver.1.0 3SUMMARYOFTESTRESULT FCCPartClauseTestParameterVerdictRemark 15.247(a)(2)DTS(6dB)BandwidthPASS 15.247(b)(3)MaximumPeakConductedOutputPowerPASS 15.247(e)MaximumPowerSpectralDensityLevelPASS 15.…

Text truncated - open the document above for the full version.

Test Setup Photos

TRFNO.FCC15/APage1of3ReportNo.:ES200311053WVer.1.0 TESTSETUPPHOTOGRAPHS 1.1.PhotosofConductedEmissionMeasurement 1.2.PhotosofRadiationEmissionMeasurement SpuriousEmissionTestSetup(Below1GHz) TRFNO.FCC15/APage2of3ReportNo.:ES200311053WVer.1.0 SpuriousEmissionTestSetup(Above1GHz) TRFNO.FCC15/APage3of3ReportNo.:ES200311053WVer.1.0 SAR RearFace0cmGapTopFace0cmGap LeftSide0cmGap ----------------Theend----------------

Contact Information

Applicant

Cynthia Brook(manager)
[email protected]001 (703) 890-6001Fax: 001 (703) 890-6001

Test Firm

EMTEK (Shenzhen) Co., Ltd.Lisa Wang
[email protected]86 755 26954280

Technical Specifications

#Rule PartsFrequency RangePower Output
215C2.40 GHz - 2.48 GHz4.00 mW
Confidentiality
Long Term
Grant Notes
Output Power listed is the maximum conducted output power. The highest reported SAR is 0.25 W/kg. This device supports 20 and 40 MHz bandwidth modes.

Other Applications from Icarsoft Technology Inc.

PROFESSIONAL MULTI-SYSTEM CAR DIAGNOSTIC TOOL - FCC ID 2AWD8-BPD7XWBTA - Icarsoft Technology Inc.
2AWD8-BPD7XWBTA

PROFESSIONAL MULTI-SYSTEM CAR DIAGNOSTIC TOOL

Sep 10, 2026

Equipment Class

DSS - Part 15 Spread Spectrum Transmitter
PROFESSIONAL MULTI-SYSTEM CAR DIAGNOSTIC TOOL - FCC ID 2AWD8-BPD7XCABA - Icarsoft Technology Inc.
2AWD8-BPD7XCABA

PROFESSIONAL MULTI-SYSTEM CAR DIAGNOSTIC TOOL

Aug 31, 2026

Equipment Class

DTS - Digital Transmission System
The wireless diagnostic interface - FCC ID 2AWD8-MSX9VCI - Icarsoft Technology Inc.
2AWD8-MSX9VCI

The wireless diagnostic interface

May 28, 2026

Equipment Class

DTS - Digital Transmission System
PROFESSIONAL MULTI-SYSTEM MARINE DIAGNOSTIC - FCC ID 2AWD8-BTX10PADA - Icarsoft Technology Inc.
2AWD8-BTX10PADA

PROFESSIONAL MULTI-SYSTEM MARINE DIAGNOSTIC

May 11, 2026

Equipment Class

DSS - Part 15 Spread Spectrum Transmitter
The wireless diagnostic interface - FCC ID 2AWD8-BTWVCIB - Icarsoft Technology Inc.
2AWD8-BTWVCIB

The wireless diagnostic interface

Jan 29, 2026

Equipment Class

DTS - Digital Transmission System