Application Details

Equipment Class
DSS - Part 15 Spread Spectrum Transmitter
Date of Grant
May 07, 2026
Application Purpose
Original Equipment
Equipment Note
BLUETOOTH AUTO-SYNC CLOCK
Frequency Range
2402.00000000 - 2480.00000000
Company
Fujian Baldr Technology Co., Ltd
Country
China

Documents & Files

Select a file to view

Users Manual

↗

Attestation Statements

↗
↗

Cover Letter(s)

↗
↗
↗

External Photos

↗

ID Label/Location Info

↗

Internal Photos

↗

RF Exposure Info

↗

Test Report

↗
↗

Test Setup Photos

↗

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

Users Manual

USER MANUAL MODEL: T0531STB-V15 BLUETOOTH AUTO-SYNC CLOCK Welcome to BALDR family! Please read the manual before use to learn about the features and functions. 4. PRECAUTIONS 6. FCC STATEMENT 3. TROUBLESHOOTING 2. HOW TO USE 1. PRODUCT INTRODUCTION 5. WARRANTY 1.1 Product Overview 1.2 Button Introduction 1.3 Code for different language 1.4 Product Specification 2.2 Set Alarm Time 2.1 Pair Clock with Bluetooth Device 08 09 07 04 01 08 01 02 03 03 07 04 CONTENTS 1. PRODUCT INTRODUCTION 1.1 Product Overview 1 6 4 5 3 2 8 10 9 7 7. 8. 9. 10. Hanging Holes Function Buttons Foldable Stand Battery Compartment Current Time Alarm Icon Bluetooth Connection Icon Low Battery Indicator Day of The Week Air Temperature 1. 2. 3. 4. 5. 6. - 01 - 1.2 Button Introduction BUTTONFUNCTION Short Press: 12/24h Switch Long Press: Enter language setting mode and confirm Short Press: Increase alarm time / °C/°F Switch /Select language when it is under language setting mode Long Press: Enter Bluetooth pairing mode Short Press: Decrease alarm time / Activate & deactivate alarm / Select language when it is under language setting mode Long Press: Turn on/off button sounds Short Press: Check alarm time / Dismiss the alarm when it’s ringing. Long Press: Enter alarm setting mode - 02 - 1.3 Code for different language Language Code English German French Spanish Italian Portuguese Dutch Danish Norwegian Swedish Polish Finnish Czech Hungarian Russian ENG GER FRE SPA ITA POR DUT DAN NOR SWE POL FIN CZE HUN RUS 1.4 Product Specification ITEMSPECIFICATION 14-122°F-9.9-50°C ±1°C 3×AA Alkaline Batteries (not included) 196ft /60m in open area without interference Temperature Range Temperature Accuracy Power Source Bluetooth Connection Range - 03 - 2.1 Pair Clock with Bluetooth Device 2. HOW TO USE Step 1: Open the battery compartment and insert 3xAA alkaline batteries (not included). The clock with automatically enter Bluetooth pairing mode for 2 min and the Bluetooth Connection Icon will keep flashing during this session. Flash rapidly under Bluetooth Connection Mode - 04 - Note: You could also manually turn on the clock’s Bluetooth pairing function by long press the pairing button at the back. The Bluetooth Connection Icon will keep flashing once the pairing function is activated. Step 2: Turn on the Bluetooth function on your Bluetooth device (i.e. smartphone or tablet). Your phone or tablet will start scanning for nearby devices Step 3: Select the clock’s name (TIME-100) from the list and add - 05 - Step 4: Once paired successfully, the Bluetooth Connection Icon will turn solid. Turn solid when paired successfully. Note: - Multiple smart devices could be connected with the clock.When pairing with an additional device, ensure that previously linked devices are out of range, or temporarily disable their Bluetooth until the new connection is complete. - When the clock starts auto-sync, it will sync with whichever family tablet or phone happens to be nearby and previously linked. Once it is synchronized, the Bluetooth Connection Icon will constantly visible on the display for 24 hrs. For example: If the clock successfully synchronizes at 3:00 am, it "locks in" this time and will skip the 1:00 pm and 10:00 pm slots on that same day. Its next attempt will be exactly 24 hours later, at 3:00 am the next day. In case of the primary 24-hour sync time fails,the clock will wait and attempt to sync at the next available pre-set time during the day. - 06 - Step 1: Long press “Alarm” button, and enter alarm setting mode. Step 2: Press “+” or “-” button to set time. Step 3: Press “Alarm” button again to confirm. 2.2 Set Alarm Time 3. TROUBLESHOOTING QUESTIONSOLUTIONPOSSIBLE REASON Bluetooth Connection Icon does not display on LCD screen after initial setup. - The clock calibrates auto- matically everyday. The Blue- tooth Connection Icon will reappear on the display if the previously linked mobile devices are within connection range during next pre-set auto-sync window. - You could also long press the pairing button at the back of the clock until Bluetooth Connection Icon flash rapidly. By doing this, you are manually initiating the clock's search function for a previously paired device. Once it finds any within range, it will synchronize its time and the Bluetooth Con- nection Icon will reappear on screen. - Re-connect the clock with Bluetooth device if it’s removed from Bluetooth list. - None of the mobile devices that are previous- ly paired with the clock are within connection range during the pre-set auto-sync windows (3:00 am, 1:00 pm, and 10:00 pm). - The clock has been removed from the Blue- tooth list on your mobile devices. Note: To activate or deactivate the alarm, please press the “ “ button at the back. - 07 - 4. PRECAUTIONS Do not clean any part of the product with benzene, thinner or other solvent chemicals. When necessary, clean it with a soft cloth. Never immerse the product in water. This can cause electrical shock and damage the product. Do not subject the product to extreme force, shock, or fluctuations in tem- perature or humidity. Do not tamper with the internal components. Do not mix new and old batteries or batteries of different types. Do not mix alkaline, standard or rechargeable batteries with this product. Remove the batteries if storing this product for a long period of time. Do not dispose of this product as unsorted municipal waste. Collection of such waste separately for special treatment is necessary. 5. WARRANTY BALDR provides a 1-year limited warranty on this product against manufactur- ing defects in materials and workmanship. Warranty service can only be performed by our authorized service center. The original dated bill of sale must be presented upon request as proof of purchase to us, or our authorized service center. The warranty covers all defects in material and workmanship with the following specified exceptions: (1) damage caused by accident, unreasonable use or neglect (including the lack or reas


Text truncated - open the document above for the full version.

Attestation Statements

FujianBaldrTechnologyCO.,LTD AddressNo.118YongnanRoad,ChengmenTown,CangshanDistrict,Fuzhou,350007 Fujian,P.R.China Date:2026-04-30 FederalCommunicationsCommission AuthorizationandEvaluationDivision 7435OaklandMillsRoad Columbia,MD21046 Ref:AttestationStatementsPart2.911(d)(7)Filing SUBJECT:FCCApplicationforFCCID:2AWDBT0531STB FRN:0029557774 (“FujianBaldrTechnologyCO.,LTD”)certifiesthat,asofthedateofthefilingoftheapplication, GOLDENVICTORYINTERNATIONALTRADINGCOLTDisourdesignatedU.S.agentfor serviceofprocessfortheabovereferencedFCCID.(“FujianBaldrTechnologyCO.,LTD”) acceptstomaintainanagentfornolessthanoneyearafterthegranteehasterminatedall marketingandimportationortheconclusionofanyCommission-relatedproceedinginvolving theequipment. GOLDENVICTORYINTERNATIONALTRADINGCOLTDaccepts,asofthedateofthefiling oftheapplication,theobligationofthedesignatedU.S.agentforserviceofprocessforthe abovereferencedFCCID. DesignatedU.S.AgentInformation: Name:GOLDENVICTORYINTERNATIONALTRADINGCOLTD Address:11016THSTREETSUITE1400DENVER,CO80202UnitedStates FRN0036377570 ContactPerson:LeonHowar Tel.:(337)255-0461 Email:[email protected] Sincerely, SignedonbehalfofFujianBaldr TechnologyCO.,LTD SignedonbehalfofGOLDENVICTORY INTERNATIONALTRADINGCOLTD Name:ChrisLiuName:LeonHowar Title:managerTitle:Manager Date:2026-04-30Date:2026-04-30

Attestation Statements

Rev1/26/2023 (FujianBaldrTechnologyCO.,LTD) FederalCommunicationsCommission AuthorizationandEvaluationDivision 7435OaklandMillsRoad Columbia,MD21046 USA Date:4-30-2026 Ref:AttestationStatementsPart2.911(d)(5)(i)Filing FCCID:2AWDBT0531STB (“FujianBaldrTechnologyCO.,LTD”)certifiesthattheequipmentforwhichauthorizationissoughtisnot “covered”equipmentprohibitedfromreceivinganequipmentauthorizationpursuanttosection2.903of theFCCrules. (“FujianBaldrTechnologyCO.,LTD”)certifiesthattheequipmentforwhichauthorizationissoughtdoes notincludecybersecurityoranti-virussoftwareproducedorprovidedbyKasperskyLab,Inc.oranyofits successorsandassignees,includingequipmentwithintegratedKasperskyLab,Inc.(oranyofits successorsandassignees)cybersecurityoranti-virussoftwarepursuanttoDA-24-886andKDB986446 D01CoveredEquipmentGuidancesectionB(2a). Deviceisinherentlycompliantbasedonhardwarelimitationsorsoftwarecontrols. or ASoftwareBillofMaterials(SBOM)isprovidedtotheTCBforreview,and Theend-userorthirdpartiescannotinstalladditionalsoftwareonthisdevice. Sincerely, (Applicantsignature): (Applicantprintedname):ChrisLiu Rev1/26/2023 (FujianBaldrTechnologyCO.,LTD) FederalCommunicationsCommission AuthorizationandEvaluationDivision 7435OaklandMillsRoad Columbia,MD21046 USA Date:4-30-2026 Ref:AttestationStatementsPart2.911(d)(5)(ii)Filing FCCID:2AWDBT0531STB (“FujianBaldrTechnologyCO.,LTD”)certifiesthat,asofthedateofthefilingoftheapplication,Fujian BaldrTechnologyCO.,LTDisnotidentifiedontheCoveredList(asaspecificallynamedentityoranyofits subsidiariesoraffiliates)asanentityproducing“covered”equipment. Sincerely, (Applicantsignature): (Applicantprintedname):ChrisLiu

Cover Letter(s)

FujianBaldrTechnologyCO.,LTD Date:April30,2026 ProductModelNumber:TAC531,T0531STB-V15 FCCID:2AWDBT0531STB Towhomitmayconcern, Re:ProductCertificationRepresentativeAuthorizationLetter WeauthorizeQAILaboratoriesLtd.3980NorthFraserWay,BurnabyB.C. CanadaV5J5K5toactonourbehalfonallmattersconcerningtheabove namedequipment. Thisshallincludethefollowing: Testing Approvalapplicationsandprocedures WedeclarethatQAILaboratoriesLtd.isallowedtoforwardallinformation relatedtotheapprovalprojecttotheappliedcertificationbodyandtothe notificationentitiesandtodiscussanyissuesconcerningtheapproval application.AnyandallactscarriedoutbyQAILaboratoriesLtd.onour behalfshallhavethesameeffectasactsofourown. By: ContactListedonFCCWesbite Title:manager Email:[email protected] Telephone:+8613788899338 Onbehalfof:FujianBaldrTechnologyCO.,LTD

Cover Letter(s)

FujianBaldrTechnologyCO.,LTD OfficeofEngineeringTechnology FederalCommunicationsCommission 7435OaklandMillsRoad Columbia,MD21046 USA Date:April30,2026 Subject;RequestforConfidentiality FCCID:2AWDBT0531STB ToWhomItMayConcern, PursuanttotheprovisionsoftheCommission’srulesTitle47Sections§0.457and§0.459,we arerequestingtheCommissiontowithholdthefollowingattachment(s)asconfidential documentsfrompublicdisclosureindefinitely. Thesedocumentscontaindetailedsystemandequipmentdescriptionsandareconsideredas proprietaryinformationinoperationoftheequipment.Thepublicdisclosureofthese documentsmightbeharmfultoourcompanyandwouldgivecompetitorsanunfairadvantage inthemarket. SchematicDiagram BlockDiagram PartsList OperationalDescription Tune-upProcedure SoftwareSecurityRequirementsforUNIIdevices Inadditionaltoabovementioneddocuments,inordertocomplywiththemarketingregulations inTitle47CFR§2.803andtheimportationrulesinTitle47CFR§2.1204,whileensuringthat businesssensitiveinformationremainsconfidentialuntiltheactualmarketingofnewly authorizeddevices,werequestShortTermConfidentialityofthefollowingattachment(s); ExternalPhotos TestSetupPhotos InternalPhotos UserManual For45days,pursuanttoPublicNoticeDA04-1705. OR For180dayspursuanttoKDB726920D01. Itisourunderstandingthatallmeasurementtestreports,FCCIDlabelformatand correspondenceduringthecertificationreviewprocesscannotbegrantedasconfidential documentsandthisinformationwillbeavailableforpublicreviewoncethegrantofequipment authorizationisissued. Sincerely, Signature: Name:ChrisLiu Title:manager

Cover Letter(s)

FujianBaldrTechnologyCO.,LTD ModelDifference Date:April30,2026 Productdescription:BLUETOOTHAUTO-SYNCCLOCK Modelname:TAC531,T0531STB-V15 FCCID:2AWDBT0531STB TAC531isthetestmodel,whileothermodelsarederivativemodels.Thesemodels arethesameonthecircuit,onlywithdifferentmodelnames,appearanceandcolour. Therefore,thetestdataofTAC531canrepresenttheremainingmodels. Client’ssignature: Client’sname/title:ChrisLiu/manager Contactinformation/address:No.118YongnanRoad,ChengmenTown,Cangshan District,Fuzhou,350007Fujian,P.R.China

External Photos

FCCID:2AWDBT0531STB EUTPHOTOSExternalPhotos FCCID:2AWDBT0531STB FCCID:2AWDBT0531STB ※※※※※ENDOFREPORT※※※※※

ID Label/Location Info

Size:3mmX20mm FCCID2AWDBT0531STB

Internal Photos

FCCID:2AWDBT0531STB EUTPHOTOSInternalPhotos FCCID:2AWDBT0531STB FCCID:2AWDBT0531STB FCCID:2AWDBT0531STB ※※※※※ENDOFREPORT※※※※※ ANT

RF Exposure Info

FCCID:2AWDBT0531STB RFExposureEvaluation AccordingtoKDB447498D01GeneralRFExposureGuidancev06andpart2.1093 UnlessspecificallyrequiredbythepublishedRFexposureKDBprocedures,standalone 1-gheadorbodyand10-gextremitySARevaluationforgeneralpopulationexposure conditions,bymeasurementornumericalsimulation,isnotrequiredwhenthe correspondingSARTestExclusionThresholdcondition(s),listedbelow,is(are)satisfied. For100MHzto6GHzandtestseparationdistances≀50mm,the1-gand10-gSAR testexclusionthresholdsaredeterminedbythefollowing: [(max.powerofchannel,includingtune-uptolerance,mW)/(min.testseparation distance,mm)]·[√f(GHz)]≀3.0for1-gSAR,and≀7.5for10-gextremitySAR,where f(GHz)istheRFchanneltransmitfrequencyinGHz PoweranddistanceareroundedtothenearestmWandmmbeforecalculationThe resultisroundedtoonedecimalplaceforcomparison Here, ForBluetooth Mode Max Power (dBm) Tune-up power (dBm) Tune-up power (mW) Frequency (MHz) Min. Distance (mm) Calc. thresholds limit BT4.534±13.16240250.9793.0 SoaSARtestisnotrequired

Test Report

AntennaSpecifications ITEMANTSPEC ModelNamePASSIVE2.4G CenterFrequency2400MHz2450MHz2500MHz Gain(dBi)-0.420-0.89 MAX.Gain0dBi AzimuthBeam Pattern Omni-directional Impedance50Ohm AntennaLength17.7±0.1mm AntennaTypePCBantenna ManufactureFujianBaldrTechnologyCO.,LTD Address No.118YongnanRoad,ChengmenTown,Cangshan District,Fuzhou,350007Fujian,P.R.China 1.AntennaPhoto&Length(mm) 2.Passivetestdata Frequency(MHz)Effi()Gain(dBi) 240042.86-0.42 241042.25-1.32 242043.23-1.27 243045.04-0.59 244045.42-0.17 245044.260 246044.78-0.76 247044.49-1.44 248042.27-1.25 249041.88-1.36 250042.73-0.87 3.Directionaldiagram

Test Report

ProjectNo.:ZHT-260203105W01 Page 1 of 91 FCCTESTREPORT FCCID:2AWDBT0531STB ApplicantName...............:FujianBaldrTechnologyCO.,LTD Address............................:No.118YongnanRoad,ChengmenTown,CangshanDistrict,Fuzhou, 350007Fujian,P.R.China ManufacturerName.........:FujianBaldrTechnologyCO.,LTD Address............................:No.118YongnanRoad,ChengmenTown,CangshanDistrict,Fuzhou, 350007Fujian,P.R.China Product............................:BLUETOOTHAUTO-SYNCCLOCK Model(s)...........................:TAC531 AdditionalModel(s)..........:T0531STB-V15 Trademark.......................:/ ModelDifference..............:TAC531isthetestmodel,whileothermodelsarederivativemodels. Thesemodelsarethesameonthecircuit,onlywithdifferentmodel names,appearanceandcolour.Therefore,thetestdataofTAC531can representtheremainingmodels. Preparedby.....................:GuangdongZhonghanTestingTechnologyCo.,Ltd. Address............................:Room104/201,Building1,YibaolaiIndustrialPark,Qiaotou,Fuhai Subdistrict,Bao'anDistrict,Shenzhen,Guangdong,China DateofReceipt................:Feb.3,2026 DateofTest(s).................:Feb.3,2026-Apr.1,2026 DateofIssue....................:Apr.1,2026 TestRequested...............:Selecttest(s)asrequestedbytheclient. TestStandard(s)..............: FCCCFRTitle47Part15SubpartCSection15.247 Testprocedure................: ANSIC63.10-2020 Intheconfigurationtested,theEUTcompliedwiththestandardsspecifiedabove. Preparedby:Reviewedby:Approvedby: KimiLu/EngineerBaretWu/DirectorLeviLee/Manager Note:Theresultsshowninthistestreportreferonlytothesample(s)testedunlessotherwisestated.Thistest reportshallnotbereproducedexceptinfull,withoutpriorwrittenapprovalofZHT.Thisdocumentmaybe alteredorrevisedbyZHT,personnelonly,andshallbenotedintherevisionofthedocument. ProjectNo.:ZHT-260203105W01 Page 2 of 91 TableofContents Page 1.TESTSUMMARY .................................................................................................................................................4 2.GENERALINFORMATION ...............................................................................................................................5 2.1GENERALDESCRIPTIONOFEUT ..............................................................................................................5 2.2TestSetupConfiguration..................................................................................................................................7 2.3SupportEquipment ............................................................................................................................................7 2.4TestMode ............................................................................................................................................................7 3.TESTFACILITYANDTESTINSTRUMENTUSED.....................................................................................8 3.1TESTFACILITY..................................................................................................................................................8 3.2EQUIPMENTSLISTFORALLTESTITEMS..............................................................................................8 3.3Testingsoftware .................................................................................................................................................9 3.4MEASUREMENTUNCERTAINTY...............................................................................................................10 4.EMCEMISSIONTEST......................................................................................................................................11 4.1Conductedemissions ......................................................................................................................................11 4.1.1POWERLINECONDUCTEDEMISSIONLimits...................................................................................11 4.1.2TESTPROCEDURE ....................................................................................................................................11 4.1.3DEVIATIONFROMTESTSTANDARD...................................................................................................11 4.1.4TESTSETUP.................................................................................................................................................12 4.1.5EUTOPERATINGCONDITIONS .............................................................................................................12 4.1.6TestResult.....................................................................................................................................................12 4.2Radiatedemissions..........................................................................................................................................13 4.2.1RadiatedEmissionLimits............................................................................................................................13 4.2.2TESTPROCEDURE....................................................................................................................................13 4.2.3DEVIATIONFROMTESTSTANDARD ...................................................................................................14 4.2.4TESTSETUP.................................................................................................................................................14 4.2.5EUTOPERATINGCONDITIONS.............................................................................................................15 4.2.6TESTRESULTS ...........................................................................................................................................16 5.RADIATEDBANDEMISSIONMEASUREMENT ......................................................................................24 5.1TestRequirement ...............................................................................................


Text truncated - open the document above for the full version.

Test Setup Photos

FCCID:2AWDBT0531STB EUTTESTPHOTOS ※※※※※ENDOFREPORT※※※※※

Contact Information

Applicant

Chris Liu(Manager)
[email protected]Fax: +86 13788899338

Technical Contact

GOLDENVICTORYINTERNATIONALTRADINGCOLTDLeon Howar
[email protected]

110 16TH STREET SUITE 1400 DENVER,CO 80202 · United States

Test Firm

Guangdong Zhonghan Testing Technology Co., Ltd.Alex Wang
[email protected]

Technical Specifications

#Rule PartsFrequency RangePower Output
115C2.40 GHz - 2.48 GHz2.80 mW
Confidentiality
Long Term
Grant Notes
Power listed is the maximum conducted output power.