FCCID.CO- FCC ID Database
HomeCompaniesEquipment ClassesSearch

© 2026 FCC ID Database. All rights reserved.

AboutContactData sourced from FCC public records
  1. Home/
  2. Cino Technology(Shenzhen)Ltd/
  3. 2AWEK-CB1-0-01

2AWEK-CB1-0-01CUBO Single Serve Home Brewing System

Cino Technology(Shenzhen)Ltd
CUBO Single Serve Home Brewing System - FCC ID 2AWEK-CB1-0-01 - Cino  Technology(Shenzhen)Ltd
Click to zoom

Application Details

Equipment Class
DXX - Part 15 Low Power Communication Device Transmitter
Date of Grant
Jun 21, 2020
Application Purpose
Original Equipment
Date of Application
Jun 21, 2020
Equipment Note
CUBO Single Serve Home Brewing System
Frequency Range
13.56000000 - 13.56000000
Company
Cino Technology(Shenzhen)Ltd
Country
China

Documents & Files

Select a file to view

Users Manual

↗

Cover Letter(s)

↗
↗

External Photos

↗

ID Label/Location Info

↗

Internal Photos

↗

RF Exposure Info

↗

Test Report

↗

Test Setup Photos

↗

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

Users Manual

Model:CB1-0-01 CUBO INSTRUCTION MANUAL Read this instruction manual carefully before operating this machine! IMPORTANT SAFEGUARDS When using electrical appliances, basic safety precautions should always be followed including the following: a ) Read all instructions. b ) To protect against risk of electrical shock do not put in water or other liquid. c ) This appliance is not intended for use by persons (including children) with reduced physical, sensory, or mental capabilities, or lack of experience and knowledge, unless they are closely supervised and instructed concerning use of the appliance by a person responsible for their safety. Close supervision is necessary when any appliance is used by or near children. Children should be supervised to ensure that they do not play with the appliance. d ) Unplug from outlet and remove all parts such as podbin and water tank before cleaning. Flashing light indicates either the machine is with top lid open and ready to operate or some parts of the machine are not attached. e ) Avoid contacting moving parts. f ) Do not operate any appliance with a damaged cord or plug or after the appliance malfunctions, or is dropped or damaged in any manner. Contact us through our customer service telephone number +1 (844) ONECUBO for information on examination, repair, or adjustment. g ) The use of attachments not recommended or sold by the manufacturer may cause fire, electric shock or injury. h ) Do not use outdoors. i ) Do not let cord hang over edge of table or counter. j ) Keep hands and utensils out of container while working to reduce the risk of severe injury to persons or damage to the machine. A scraper may be used but must be used only when the machine is not working. k ) Blades are sharp. Handle carefully. l ) Always operate machine with cover in place. m ) Do not touch hot surfaces. Use handles or knobs. n ) Do not place on or near a hot gas or electric burner, or in a heated oven. o ) Always attach plug to appliance first, then plug cord into the wall outlet. To disconnect, turn any control to off, then remove plug from wall outlet. p ) Do not use appliance for other than intended use. FCC ID Warning Warning: Changes or modifications to this unit not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment. Note: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures: - Reorient or relocate the receiving antenna. - Increase the separation between the equipment and receiver. - Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. - Consult the dealer or an experienced radio/TV technician for help. Déclaration d’IC sur l’exposition aux radiations: Cet équipement est conforme aux limites d’exposition aux radiations définies par le Canada pour des environnements non contrôlés. Cet émetteur ne doit pas être installé au même endroit ni utilisé avec une autre antenne ou un autre émetteur. This device contains licence-exempt transmitter(s)/receiver(s) that comply with Innovation, Science and Economic Development Canada’s licence-exempt RSS(s). Operation is subject to the following two conditions: (1) This device may not cause interference. (2) This device must accept any interference, including interference that may cause undesired operation of the device. IC Radiation Exposure Statement: This equipment complies with Canada radiation exposure limits set forth for uncontrolled environments.This transmitter must not be co-located or operating in conjunction with any other antenna or transmitter. L’émetteur/récepteur exempt de licence contenu dans le présent appareil est conforme aux CNR d’Innovation, Sciences et Développement économique Canada applicables aux appareils radio exempts de licence. L’exploitation est autorisée aux deux conditions suivantes: 1) L’appareil ne doit pas produire de brouillage; 2) L’appareil doit accepter tout brouillage radioélectrique subi, même si le brouillage est susceptible d’en compromettre le fonctionnement. Content PRODUCT OVERVIEW .......................................................................... 1 OPERATING INSTRUCTIONS .............................................................. 1 1. Before use ...................................................................................... 1 2. First time cleaning ........................................................................ 2 3. Variations and adjustments ........................................................ 3 4. Auto cleaning .................................................................................. 4 CUBOPODS ........................................................................................... 4 1. Storing CUBOPODS .................................................................... 4 2. Using CUBOPODS ........................................................................ 4 SETTINGS MENU .................................................................................. 4 1. Order CUBOPODS ....................................................................... 5 2. Cleaning options menu .............................................................. 5 CLEANING ........................................................…

Text truncated - open the document above for the full version.

RF Exposure Info

Intertek Testing Services Shenzhen Ltd. Guangzhou Branch Job No.: 200409026GZU-002 Page: 1 of 2 FCC ID: 2AWEK-CB1-0-01 RF Exposure Compliance Requirement E (V/m)=(30*P*G) 0.5 /d E=Electric Field (V/m) Remark: E(V/m)=10X (dBUV/m) /20 *10 -6 P=Peak RF output Power (W) G=EUT Antenna numeric gain (numeric) d= Separation distance between radiator and human body (m) in the formula above: d=3m, E =53dBuV/m (max. value provided by client), antenna gain=0dBi P=0.0000599mW In KDB 447498 D01 v06: 4.3.1 Standalone SAR test exclusion considerations: Formulas as below: P ≤ (3 x m)/√f (GHz) a) P is the max. power of channel, including tune-up tolerance, mW Intertek Testing Services Shenzhen Ltd. Guangzhou Branch Job No.: 200409026GZU-002 Page: 2 of 2 FCC ID: 2AWEK-CB1-0-01 m is min.test separation distance, mm f (GHZ) is the RF channel transmit frequency in GHz P≤ (3 x 50)/√ f (GHZ) + (m-50)x f (MHZ) /150 b)1) P≤ [(3x50)/√0.1 + (m-50)x100/150] x [1+lg(100/ f (MHZ) )] c)1) P≤ {[(3x50)/√0.1 + (50-50)x100/150] x (1+lg100/100)} x 1/2 c)2) P ≤ 237.19mW The SAR Test Exclusion Threshold is calculated from: [(max. power of channel, including tune-up tolerance, mW)/(min. test separation distance, mm)] ·[√f(GHz)] ≤ 3.0 for 1-g SAR. The worst case test separation distance is 5mm. The transmission frequencies of the device are below 100 MHz. The SAR Test Exclusion Threshold (mW) are listed below: Transmit frequency (MHz) ERP (mW) SAR Test Exclusion Threshold (mW) 13.56 0.0000599 237.19

Test Report

CINO Technology(shenzhe n)Ltd TEST REPORT SCOPE OF WORK EMC TESTING–CB1-0-01 REPORT NUMBER 200409026GZU-001 ISSUE DATE [REVISED DATE] 15-June-2020 [---------------------] PAGES 29 DOCUMENT CONTROL NUMBER FCC Part 15.225-b © 2017 INTERTEK TEST REPORT Block E, No.7-2 Guang Dong Software Science Park, Caipin Road, Guangzhou Science City, GETDD Guangzhou, China Telephone: 86-20-8213 9688 Facsimile: 86-20-3205 7538 www.intertek.com This report is for the exclusive use of Intertek's Client and is provided pursuant to the agreement between Intertek and its Client. Intertek's responsibility and liability are limited to the terms and conditions of the agreement. Intertek assumes no liability to any party, other than to the Client in accordance with the agreement, for any loss, expense or damage occasioned by the use of this report. Only the Client is authorized to permit copying or distribution of this report and then only in its entirety. Any use of the Intertek name or one of its marks for the sale or advertisement of the tested material, product or service must first be approved in writing by Intertek. The observations and test results in this report are relevant only to the sample tested. This report by itself does not imply that the material, product, or service is or has ever been under an Intertek certification program. Version: 10 June 2019 Page 2 of 29 FCC Part 15.225-b Applicant Name & Address : CINO Technology(shenzhen)Ltd 3rd, 4th & 5th floor, G Building, Licheng Scientific and Technology Industrial P shenzhen, China Manufacturing Site : Same as applicant Intertek Report No: FCC ID: 200409026GZU-001 2AWEK -CB1-0-01 Test standards 47 CFR PART 15 Subpart C: 2019 section 15.225 Sample Description Product : CUBO Single Serve Home Brewing System Model No. : CB1-0-01 Electrical Rating : 120Vac, 60Hz Serial No. Not Labeled Date Received : 09 April 2020 Date Test Conducted : 09 April 2020-27 May 2020 Prepared and Checked By Daniel He Project Engineer Intertek Guangzhou Approved By: Helen Ma Team Leader Intertek Guangzhou TEST REPORT Intertek Report: No: 200409026GZU-001 Version: 10 June 2019 Page 3 of 29 FCC Part 15.225-b CONTENT TEST REPORT ........................................................................................................................... 1 CONTENT ............................................................................................................................. 3 1.0 TEST RESULT SUMMARY ............................................................................................ 4 2.0 GENERAL DESCRIPTION ............................................................................................. 5 2.1 P RODUCT DESCRIPTION ........................................................................................................ 5 2.2 R ELATED SUBMITTAL(S) GRANTS ........................................................................................... 5 2.3 T EST METHODOLOGY .......................................................................................................... 5 2.4 T EST FACILITY ..................................................................................................................... 5 3.0 SYSTEM TEST CONFIGURATION ................................................................................. 6 3.1 J USTIFICATION .................................................................................................................... 6 3.2 EUT EXERCISING SOFTWARE ................................................................................................. 7 3.3 S PECIAL ACCESSORIES .......................................................................................................... 7 3.4 M EASUREMENT UNCERTAINTY .............................................................................................. 7 3.5 E QUIPMENT MODIFICATION ................................................................................................. 8 3.6 S UPPORT EQUIPMENT LIST AND DESCRIPTION .......................................................................... 8 4.0 MEASUREMENT RESULTS .......................................................................................... 9 4.1 A NTENNA REQUIREMENT ..................................................................................................... 9 4.2 O CCUPIED BANDWIDTH ..................................................................................................... 10 4.3 R ADIATED EMISSION .......................................................................................................... 12 4.4 F REQUENCY STABILITY ....................................................................................................... 23 4.5 C ONDUCTED EMISSION TEST ............................................................................................... 25 5.0 TEST EQUIPMENT LIST ............................................................................................. 28 TEST REPORT Intertek Report: No: 200409026GZU-001 Version: 10 June 2019 Page 4 of 29 FCC Part 15.225-b 1.0 TEST RESULT SUMMARY Test ItemTest RequirementTest MethodResult Antenna Requirement FCC PART 15 C Section 15.203 FCC PART 15 C Section 15.203 PASS Occupied Bandwidth FCC PART 15 C section 15.215(c) ANSI C63.10: Clause 6.9 PASS Radiated Emission FCC PART 15 C section 15.225 (a), (b), (c), (d) ANSI C63.10: Clause 6.4 & 6.5 PASS Frequency Stability FCC PART 15 C section 15.225 (e) ANSI C63.10: Clause 6.8 PASS Conducted Emissions at Mains Terminals FCC PART 15 C section 15.207 ANSI C63.10: Clause 6.2 PASS Remark: N/A: not applicable. Refer to the relative section for the details. EUT: In this whole report EUT means Equipment Under Test. Tx: In this whole report Tx (or tx) means Transmitter. Rx: In this whole report Rx (or rx) means Receiver. RF: In this whole report RF means Radio Frequency. ANSI C63.10: the detail version is ANSI C63.10:2013 in the whole report TEST REPORT Intertek Report: No: 2004090…

Text truncated - open the document above for the full version.

Test Setup Photos

1. Radiated Emissions in Restricted Bands: 9kHz to 30MHz 30MHz to 1GHz: 2. Conducted Emissions at Mains Terminals

Contact Information

Applicant

jin miao peng
[email protected]0086 755 29850626Fax: 0086 755 29850545

Technical Contact

Intertek Testing Services Shenzhen Ltd.Guangzhou BDaniel He
[email protected]+86 20 82139616

lock E, No.7-2 Guang Dong Software Science Park, C · Guangzhou, Guangdong · China

Non-Technical Contact

Intertek Testing Services Shenzhen Ltd.Guangzhou BDaniel He
[email protected]+86 20 82139616

Test Firm

Intertek Testing Services Shenzhen LTD., GuangzhouEmily Huang
[email protected]+86 21 50319089-232

Technical Specifications

#Rule PartsFrequency RangePower Output
115C13.56 MHz - 13.56 MHz-
Confidentiality
Long Term

Other Applications from Cino Technology(Shenzhen)Ltd

CUBO Single Serve Beverage System - FCC ID 2AWEK-CB1-0-01A - Shenzhen Cino Technology Ltd
2AWEK-CB1-0-01A

CUBO Single Serve Beverage System

Jul 24, 2026

Equipment Class

DXX - Part 15 Low Power Communication Device Transmitter