ShenZhenshi GYBB Technology Co., Ltd. 2.911 (d)(5)(i) Equipment Type Attestation v1.2 Section 2.911(d)(5)(i) Certification – Equipment Type Company name: ShenZhenshi GYBB Technology Co., Ltd. Address: 10F, Building 1, Xinlikang Industry Park, Xialilang, Nanwan, Longgang, Shenzhen Product Name: Wireless Car Charger Mount FCC ID: 2AWF9-GBA26B Model(s): A26 2.911(d)(5)(i) Equipment Type We, [ShenZhenshi GYBB Technology Co., Ltd.] (“the applicant”) certify that the equipment for which authorization is sought through certification is not: Prohibited from receiving an equipment authorization pursuant to § 2.903; of the FCC rules. Identified as an equipment type in the “Covered List” NOTE 1 Yours sincerely, Name: Wedina Date: Apr. 19, 2023 Title and Company name: Manager; ShenZhenshi GYBB Technology Co., Ltd. NOTE 1 “Covered List”; is the List of Equipment and Services Covered By Section 2 of The Secure Networks Act, available at https://www.fcc.gov/supplychain/coveredlist References; 1) 986446 D01 Covered Equipment v01 https://apps.fcc.gov/oetcf/kdb/forms/FTSSearchResultPage.cfm?switch=P&id=325672 2) Federal Register document 2022-28263 published on 02/06/23 https://www.federalregister.gov/documents/2023/02/06/2022-28263/protecting-against-national-security-threats-to-the-com munications-supply-chain-through-the
ShenZhenshi GYBB Technology Co., Ltd. 2.911 (d)(5)(ii) Applicant Attestation v1.2 Section 2.911(d)(5)(ii) Certification – Applicant (Covered List ) Company name: ShenZhenshi GYBB Technology Co., Ltd. Address: 10F, Building 1, Xinlikang Industry Park, Xialilang, Nanwan, Longgang, Shenzhen Product Name: Wireless Car Charger Mount FCC ID: 2AWF9-GBA26B Model(s): A26 2.911(d)(5)(ii) Applicant filing We, [ShenZhenshi GYBB Technology Co., Ltd.] (“the applicant”) certify that, as of the date of the filing of the application, the applicant is not identified NOTE 1 on the “Covered List” NOTE 2 , established pursuant to § 1.50002 of this chapter, as an entity producing covered communications equipment. Yours sincerely, Name: Wedina Date: Apr. 19, 2023 Title and Company name: Manager; ShenZhenshi GYBB Technology Co., Ltd. NOTE 1 Delete option not applicable to this application. NOTE 2 “Covered List”; is the List of Equipment and Services Covered By Section 2 of The Secure Networks Act, available at https://www.fcc.gov/supplychain/coveredlist References; 1) 986446 D01 Covered Equipment v01 https://apps.fcc.gov/oetcf/kdb/forms/FTSSearchResultPage.cfm?switch=P&id=325672 2) Federal Register document 2022-28263 published on 02/06/23 https://www.federalregister.gov/documents/2023/02/06/2022-28263/protecting-against-national-security-threats-to-the-com munications-supply-chain-through-the
ShenZhenshi GYBB Technology Co., Ltd. We, [ShenZhenshi GYBB Technology Co., Ltd.] ("the applicant") designate [ UA INTERNATIONAL INC.] Note1 for the purpose of accepting service of process on behalf of the applicant. Applicant consent: We Acknowledge our consent to accept service of process in the United States for matters related to the applicable equipment, and at the physical U.S. address and email address of the designated agent and acknowledge our acceptance of our obligation to maintain an agent for service of process in the United States for no less than one year after either the grantee has permanently terminated all marketing and importation of the applicable equipment within the U.S., or the conclusion of any Commission-related administrative or judicial proceeding involving the equipment, whichever is later. Agent obligation: We Acknowledge our obligation to accept service of process in the United States for matters related to the applicable equipment at our physical U.S. address and email address for no less than one year after either the grantee has permanently terminated all marketing and importation of the applicable equipment within the U.S., or the conclusion of any Commission-related administrative or judicial proceeding involving the equipment, whichever is later.
< ShenZhenshi GYBB Technology Co., Ltd.> Office of Engineering Technology Federal Communications Commission 7435 Oakland Mills Road Columbia, MD21046 Date: Apr. 19, 2023 Subject; Request for Long Term Confidentiality FCC ID: 2AWF9-GBA26B To Whom It May Concern, Pursuant to the provisions of the Commission’s rules Title 47 Sections §0.457 and §0.459, we are requesting the Commission to withhold the following attachment(s) as confidential documents from public disclosure indefinitely. These documents contain detailed system and equipment descriptions and are considered as proprietary information in operation of the equipment. The public disclosure of these documents might be harmful to our company and would give competitors an unfair advantage in the market. Schematic Diagram Block Diagram Parts List Operational Description Tune-up Procedure It is our understanding that all measurement test reports, FCC ID label format and correspondence during the certification review process cannot be granted as confidential documents and this information will be available for public review once the grant of equipment authorization is issued. Sincerely, Signature: Name: Wedina Title: Manager
ShenZhenshi GYBB Technology Co., Ltd. Letter of Authorization Company: ShenZhenshi GYBB Technology Co., Ltd. Address: 10F, Building 1, Xinlikang Industry Park, Xialilang, Nanwan, Longgang, Shenzhen Product name: Wireless Car Charger Mount Trade name: N/A Model name: A26 FCC Identifier: 2AWF9-GBA26B We authorize MiCOM LabsInc, 575 Boulder Court, Pleasanton, California94566, USA, to act on our behalf on all matters concerning the above named equipment. Any individual within MiCOM Labs is authorized to act on our behalf and take action on the application. We declare that MiCOM LabsInc, 575 Boulder Court, Pleasanton, California 94566, USA, is allowed to forward all information related to the approval project to the Federal Communication Commission and to discuss any issues concerning the approval application. Any and all acts carried out by MiCOM Labs on our behalf shall have the same effect as acts of our own. Name: Wedina Date: Apr. 19, 2023 Title: Manager Signature of applicant:
Model: A26
FCC ID LABEL: Label Location: FCC ID: 2AWF9-GBA26B Product name: Wireless Car Charger Mount Model name: A26 Power: DC 5V/9V
Model: A26 Coil Antenna
Page 1 of 9 Report No.: UNIA23030906E R-62 FCC MPE TEST REPORT FCC ID: 2AWF9-GBA26B Sample: Wireless Car Charger Mount Trade Name: N/A Main Model : A26 Additional Model: N/A Report No.: UNIA23030906ER-62 Prepared for ShenZhenshi GYBB Technology C o., Ltd. 10F, Building 1, Xinlikang Industry Park, Xialilang, Nanwan, Longgang, Shenzhen Prepared by Shenzhen United Testing Technology Co., Ltd. 2F, Annex Bldg, Jiahuangyuan Tech Park, #365 Baotian 1 Rd, Tiegang C ommuni ty, Xi xi ang Str, Bao'an D i stri ct, Shenzhen, C hi na Page 2 of 9 Report No.: UNIA23030906E R-62 TEST RESULT CERT IFICAT ION Applicant ............................... : ShenZhenshi GYBB Technology Co,Ltd. Address................................... : 10F, Building 1, Xinlikang Industry Park, Xialilang, Nanwan, Longgang, Shenzhen Manufacturer ......................... : ShenZhenshi GYBB Technology Co,Ltd. Address................................... : 10F, Building 1, Xinlikang Industry Park, Xialilang, Nanwan, Longgang, Shenzhen Product description Product ................................... : Wireless Car Charger Mount Trade Name ............................ : N/A Model Name ........................... : A26 Test Methods ......................... : FCC KDB 680106 D01 RF Exposure Wireless Charging Apps v03 This device described above has been tested by Shenzhen United Testing Technology Co., Ltd., and the test results show that the equipment under test (EUT) is in compliance with the FCC requirements. And it is applicable only to the tested sample identified in the report. This report shall not be reproduced except i n full, without the written approval of UNI, this document may be altered or revised by Shenzhen United Testing Technology Co., Ltd., personnel only, and shall be noted in the revision of the document. Date of Test .......................................... : Date (s) of performance of tests ............ : Mar. 09, 2023 ~ Apr. 07, 2023 Date of Issue.......................................... : Apr. 14, 2023 Test Result ............................................. : Pass Prepared by: Jason Ye/Editor Reviewer: Kelly C heng/Supervisor Approved & Authorized Signer: Liuze/Manager Page 3 of 9 Report No.: UNIA23030906E R-62 Note: For a more detailed features description, please refer to the manufacturer’s specifications or the User's Manual. Channel List Channel Frequency(KHz) Channel Frequency(MHz) 01 120 The EUT antenna is Coil Antenna. No antenna other than that furnished by the responsible party shall be used with the device. 1. SUMMARY OF TEST RESULTS 1.1 Test procedures according to the technical standards: FCC KDB 680106 D01 RF Exposure Wireless Charging Apps v03 FCC CFR 47 Standard Section Test Item Judgment Remark FCC CFR 47 part1, 1.1310 KDB680106 D01 v0 3(3)(3) Electric Field Strength (E) (V/m) PASS Magnetic Field Strength (H) (A/m) PASS Compliant with KDB680106 D01 RF Exposure Wireless Charging Apps v03 section 5, b: a) Power transfer frequency is less than 1MHz. Yes, the working frequency is 110-205KHz. b) Output power from each primary coil is less than or equal to 15 watts. Yes, the maximum output power is 15 watts. c) The transfer system includes only single primary and secondary coils. This includes charging systems that may have multiple primary coils and clients that are able to detect and allow coupling only between individual pairs of coils. Yes, the transfer system includes only single primary coil. d) Client device is placed directly in contact with the transmitter. Yes, client device is placed directly in contact with the transmitter. e) Mobile exposure conditions only (portable exposure conditions are not covered by this exclusion). Yes, EUT is for mobile exposure conditions only. f) The aggregate H-field strengths at 15 cm surrounding the device and 20 cm above the top surface from all simultaneous transmitting coils are demonstrated to be less than 50% of the MPE limit. Yes, E UT h-field strengths levels are less than 50% of the MPE limit. Page 4 of 9 Report No.: UNIA23030906E R-62 1.2 MEASUREMENT UNCERTAINTY The reported uncertainty of measurement y±U, where expended uncertainty U is based on a standard uncertainty multiplied by a coverage factor of k=2, providing a level of confidence of approximately 95 %. No. Item Uncertainty 1 Radiated Measurement (9KHz-30MHz) ±2.50dB 2 Temperature ±0.5°C 3 Humidity ±2% 1.3 Test Instruments Description Brand Model No. Frequency Range Calibrated Until Broadband Field Meter NARDA NBM-550 –– Jan. 01, 2024 Magnetic Field Meter NARDA ELT-400 1–400kHz Jan. 01, 2024 Magnetic Probe NARDA HF-3061 300kHz–30MHz Jan. 01, 2024 Magnetic Probe NARDA HF-0191 27–1000MHz Jan. 01, 2024 Broadband Field Meter NARDA NBM-550 –– Jan. 01, 2024 Electric Field Meter COMBINOVA EFM 200 5Hz–400kHz Jan. 01, 2024 E-Field Probe NARDA EF-0391 100kHz–3GHz Jan. 01, 2024 E-Field Probe NARDA EF-6091 100MHz–60GHz Jan. 01, 2024 NOTE : The calibration interval of the above test instruments is 12 months. Page 5 of 9 Report No.: UNIA23030906E R-62 2. MAXIMUM PERMISSIBLE EXPOSURE 2.1 MAXI MU M PERMISSIBLE EXPOSURE Limit of Maximum Permissible Exposure Limits for Occupational / Controlled Exposure Frequency Range (MHz) Electric Field Strength (E) (V/m) Magnetic Field Strength (H) (A/m) Power Density (S) (mW/ cm²) Averaging Time |E|²,|H|² or S (minutes) 0.3-3.0 614 1.63 (100)* 6 3.0-30 1842 / f 4.89 / f (900 / f)* 6 30-300 61.4 0.163 1.0 6 300-1500 F/300 6 1500-100,000 5 6 Limits for General Population / Uncontrolled Exposure Frequency Range (MHz) Electric Field Strength (E) (V/m) Magnetic Field Strength (H) (A/m) Power Density (S) (mW/ cm²) Averaging Tim e |E|²,|H|² or S (minutes) 0.3-1.34 614 1.63 (100)* 30 1.34-30 824/f 2.19/f (180 / f)* 30 30-300 27.5 0.073 0.2 30 300-1500 F/1500 30 1500-100,000 1 30 Note 1: f = frequency in MHz ; *Plane-wave equivalent power density. 2: For the applicable limit, see FCC 1.1310, 680106 D01 RF Exposure Wireless Charging Apps v03. 3: Emissions between 100 kHz to 300 …
Text truncated - open the document above for the full version.
Fine Page 1 of 3 承 認 書 SPECIFICATION FOR APPROVAL 客 戶: CUSTOMER: 深圳市一牛一科技有限公司 客 戶 料 號: CUST P/N: 料 號: FINE P/N: Q5440/45MM 産 品 型 號: DESC: F20x29.0-9Ts-0.08x105P-45mm 日 期: DATE: 2022/07/28 版 本: Version: A.0 擬制 PREPARED BY 審核 CHECKED BY 批准 APPROVED BY 客戶承認 CUSTOMER APPROVE 黄燕铭 宁元安 黄燕铭 东莞市西联干城科技有限公司 工廠地址:东莞市东坑镇骏发路123号三甲高新技术产业园2栋8楼 TEL:0769-82989159 FAX:0769-82989159 E-mail:[email protected] Fine Page 2 of 3 版本變更履歷 Version Change History 版本 Rev. 變 更 前 Before Change 變 更 後 After Change 更 改 日 期 Change Date 批 准 Approved By A.0 新发行 ---- 2022/03/16 黄燕铭 Fine Page 3 of 3 SPECIFICATION 産 品 型 號: DESC F20x29.0-9Ts--0.08x105P-45mm 版本 Rev:A.0 客戶CUST: 松岛料号 Fine P/N: SD4752 客户料号CUST P/N: 双线圈 一、尺寸DIMENSION:(mm) 二、原理图SCHEMATIC DIAGRAM: A 3±2 B 45±2 C 23±1.0 D 10±1.0 E 40±1.0 F 49±1.0 J 53.5±0.5 H 20±1 K 41±1 注: 1.单个磁片尺寸为F54*41mm厚度 0.8mm,用双面胶粘接,并且带手撕 位; 2.上线圈出线位置缠8mm宽度高 温胶纸1-2Ts; 三、绕线参数Winding Specification: 序号 NO. 端子 TERMINAL 线径 WIRE 圈数 Turns 绕线方向 Winding Direction 1 S F 丝包线0.08*105P 9Ts CCW 四、电气特性ELECTRICAL CHARACTERISTICS: 温度TEMPERATURE:25±10°C, 湿度RELATIVE HUMIDITY:65±20% 序号 NO. 项目 ITEM 端子 TERMINAL 标准 SPECIFICATION 测试条件 TEST FREQUENCY 测试仪器 TEST EQUIPMENTS 1 IND. S-F 3.8uH±10% 单独线圈 100KHz/1.0V LCZ METER 1062B 2 IND. S-F 6.3uH±10% 加贴磁片线圈 100KHz/1.0V LCZ METER 1062B 3 DCR S-F ≤45mΩ 100KHz/1.0V LCZ METER 1062B 4 Q S-F ≤75 100KHz/1.0V LCZ METER 1062B 擬制/日期PREPARED BY/DATE 審核/日期CHECKED BY/DATE 黄燕铭2022/7/28 黄锦华2022/7/28
Page 1 of 22 Report No.: UNIA23030906ER-61 FCC RADIO TEST REPORT FCC ID: 2AWF9-GBA26B Sample: Wireless Car Charger Mount Trade Name: N/A Main Model: A26 Additional Model: N/A Report No.: UNIA23030906ER-61 Prepared for ShenZhenshi GYBB Technology Co., Ltd. 10F, Building 1, Xinlikang Industry Park, Xialilang, Nanwan, Longgang, Shenzhen Prepared by Shenzhen United Testing Technology Co., Ltd. 2F, Annex Bldg, Jiahuangyuan Tech Park, #365 Baotian 1 Rd, Tiegang Community, Xixiang Str, Bao'an District, Shenzhen, China Page 2 of 22 Report No.: UNIA23030906ER-61 TEST RESULT CERTIFICATION Applicant .............................. : ShenZhenshi GYBB Technology Co,Ltd. Address ................................. : 10F, Building 1, Xinlikang Industry Park, Xialilang, Nanwan, Longgang, Shenzhen Manufacturer ........................ : ShenZhenshi GYBB Technology Co,Ltd. Address ................................. : 10F, Building 1, Xinlikang Industry Park, Xialilang, Nanwan, Longgang, Shenzhen Product description Product .................................. : Wireless Car Charger Mount Trade Name ........................... : N/A Model Name .......................... : A26 Test Methods ........................ : FCC Rules and Regulations Part 15 Subpart C Section 15.209 ANSI C63.10: 2013 This device described above has been tested by Shenzhen United Testing Technology Co., Ltd., and the test results show that the equipment under test (EUT) is in compliance with the FCC requirements. And it is applicable only to the tested sample identified in the report. This report shall not be reproduced except in full, without the written approval of UNI, this document may be altered or revised by Shenzhen United Testing Technology Co., Ltd., personnel only, and shall be noted in the revision of the document. Date of Test Date (s) of performance of tests ............. : Mar. 09, 2023 ~ Apr. 07, 2023 Date of Issue .......................................... : Apr. 14, 2023 Test Result.............................................. : Pass Prepared by: Jason Ye/Editor Reviewer: Kelly Cheng/Supervisor Approved & Authorized Signer: Liuze/Manager Page 3 of 22 Report No.: UNIA23030906ER-61 Table of Contents Pages 1 TEST SUMMARY 4 1.1 TEST PROCEDURES AND RESULTS 4 1.2 TEST FACILITY 4 1.3 MEASUREMENT UNCERTAINTY 5 2 GENERAL INFORMATION 6 2.1 GENERAL DESCRIPTION OF EUT 6 2.2 CARRIER FREQUENCY OF CHANNELS 7 2.3 TEST MODE 7 2.4 TEST SETUP 7 2.5 DESCRIPTION TEST PERIPHERAL AND EUT PERIPHERAL 8 2.6 MEASUREMENT INSTRUMENTS LIST 9 3 CONDUCTED EMISSION 10 3.1 TEST LIMIT 10 3.2 TEST SETUP 10 3.3 TEST PROCEDURE 11 3.4 TEST RESULT 11 4 RADIATED EMISSION 14 4.1 TEST LIMIT 14 4.2 TEST SETUP 16 4.3 TEST PROCEDURE 17 4.4 TEST RESULT 17 5 ANTENNA REQUIREMENT 20 6 PHOTO OF TEST 21 6.1 RADIATED EMISSION 21 6.2 CONDUCTED EMISSION 22 Page 4 of 22 Report No.: UNIA23030906ER-61 1 TEST SUMMARY 1.1 TEST PROCEDURES AND RESULTS Item FCC Rules Description Of Test Result 1 FCC Part 15.207 Conducted Emission Pass 2 FCC Part 15.209(a) Radiated Emission Pass 3 FCC Part 15.203 Antenna Requirement Pass 1.2 TEST FACILITY Test Firm : Shenzhen United Testing Technology Co., Ltd. Address : 2F, Annex Bldg, Jiahuangyuan Tech Park, #365 Baotian 1 Rd,Tiegang Community, Xixiang Str, Bao'an District, Shenzhen, China The testing quality ability of our laboratory meet with "Quality Law of People's Republic of China" Clause 19.The testing quality system of our laboratory meets with ISO/IEC-17025 requirements. This approval result is accepted by MRA of APLAC. Our test facility is recognized, certified, or accredited by the following organizations: A2LA Certificate Number: 4747.01 The EMC Laboratory has been accredited by A2LA, and in compliance with ISO/IEC 17025:2017 General Requirements for testing Laboratories. FCC Registration Number: 0027159896 The EMC Laboratory has been registered and fully described in a report filed with the (FCC) Federal Communications commission. IC Registration Number: 21947 The EMC Laboratory has been registered and fully described in a report filed with the (IC) Industry Canada. Page 5 of 22 Report No.: UNIA23030906ER-61 1.3 MEASUREMENT UNCERTAINTY The reported uncertainty of measurement y ± U, where expended uncertainty U is based on a standard uncertainty multiplied by a coverage factor of k=2, providing a level of confidence of approximately 95 %. A. Conducted Measurement: Test Site Method Measurement Frequency Range U, (dB) NOTE UNI ANSI 9KHz ~ 150KHz 2.96 150KHz ~ 30MHz 2.44 B. Radiated Measurement: Test Site Method Measurement Frequency Range U, (dB) NOTE UNI ANSI 9KHz ~ 30MHz 2.50 30MHz ~ 1000MHz 4.80 1000MHz ~ 6000MHz 4.13 Page 6 of 22 Report No.: UNIA23030906ER-61 2 GENERAL INFORMATION 2.1 GENERAL DESCRIPTION OF EUT Product: Wireless Car Charger Mount Trade Name: N/A Main Model: A26 Additional Model: N/A Model Difference: N/A FCC ID: 2AWF9-GBA26B Operation Frequency: 110-205KHz Number of Channels: 1CH Modulation Type: ASK Antenna Type: Coil Antenna Antenna Gain: 0dBi Battery: N/A Adapter: N/A Power Source: DC 5V/9V Page 7 of 22 Report No.: UNIA23030906ER-61 2.2 CARRIER FREQUENCY OF CHANNELS Channel List Channel Frequency (KHz) Channel Frequency (KHz) Channel Frequency (KHz) Channel Frequency (KHz) 01 120 -- -- -- -- -- -- 2.3 TEST MODE The EUT was programmed to be in transmitting mode. Channel List Test Channel Test Frequency (KHz) 01 120 2.4 TEST SETUP Operation of EUT during testing: AE EUT Adapter Page 8 of 22 Report No.: UNIA23030906ER-61 2.5 DESCRIPTION TEST PERIPHERAL AND EUT PERIPHERAL The EUT has been tested as an independent unit together with other necessary accessories or support units. The following support units or accessories were used to form a representative test configuration during the tests. Item Equipment Mfr/Brand Model/Type No. Note E-1 Wireless Car Charger Mount N/A A26 EUT E-2 Adapter Xiaomi -- AE E-3 WPT Station N/A N/A AE Item Shielded Type Ferrite Core Length Note Note: 1. The support equipment was authorized by D…
Text truncated - open the document above for the full version.
Model: A26 Radiated Emission test Model: A26 Conducted Emission test MPE test Model: A26 Model: A26
| # | Rule Parts | Frequency Range | Power Output |
|---|---|---|---|
| 1 | 15C | 0.11 MHz - 0.205 MHz | - |

Vehicle wireless charging bracket
Equipment Class
DCD - Part 15 Low Power Transmitter Below 1705 kHz
Vehicle wireless charging bracket
Equipment Class
DCD - Part 15 Low Power Transmitter Below 1705 kHz
Vehicle wireless charging bracket
Equipment Class
DCD - Part 15 Low Power Transmitter Below 1705 kHz
wireless charger sterilizer
Equipment Class
DCD - Part 15 Low Power Transmitter Below 1705 kHz