Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.
FCC Warning Statement Changes or modifications not expressly approved by the party responsible for compliance could void the userās authority to operate the equipment. This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures: āā Reorient or relocate the receiving antenna. āā Increase the separation between the equipment and receiver. āā Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. āā Consult the dealer or an experienced radio/TV technician for help.
LetterofDeclaration Company:SHENZHENBWAYTECHCO.,LTD Address:FL3,BLDGA,NO4,LONGSHAN4THRD,LUOTIANCOMMUNITY ShenzhenChina ProductName:IONUVPROPHONESANITIZER ModelNumber:7609 FCCIdentifier:2AWFB-KCWSC CompliantwithKDB680106D01RFExposureWirelessChargingAppsv03section5,b: 1:Chargingfrequencyislessthan1MHz; Yes,Theworkingfrequencyoftheprototypeis125KHz. 2:Theoutputpowerofeachprimarycoilislessthan15watts; Yes,Themaximumoutputpoweroftheprototypeis5watts. 3:Theenergytransferonlyincludestheprimaryandsecondarycoils.Somechargingsystemscontain multipleprimarycoils,whichcandetectmultiplechargedproducts.Thecouplingofenergyisonly betweenthepairedprimaryandsecondarycoils. Yes,thetransfersystemincludesonlysingleprimaryandsecondarycoils. 4:Clientdeviceisplaceddirectlyincontactwiththetransmitter. Yes. 5:Mobileexposureconditionsonly(mobileexposureconditionsarenotcoveredbythisexclusion). Yes,theEUTisformobileexponsureconditionsonly. 6:TheaggregateH-fieldstrengthsat15cmsurroundingthedeviceand20cmabovethetopsurface formallsimultaneoustransmittingcoilsaredemonstratedtobelessthan50%oftheMPElimit. Yes,theEUTh-fieldstrengthslevelsarelessthan50%oftheMPElimit. Name:SaraLuoDate:Aug.17,2020 Title:Manager Signatureofapplicant:
<SHENZHENBWAYTECHCO.,LTD> OfficeofEngineeringTechnology FederalCommunicationsCommission 7435OaklandMillsRoad Columbia,MD21046 Date:Aug.17,2020 Subject;RequestforLongTermConfidentiality FCCID:2AWFB-KCWSC ToWhomItMayConcern, PursuanttotheprovisionsoftheCommissionāsrulesTitle47Sections§0.457and§0.459,weare requestingtheCommissiontowithholdthefollowingattachment(s)asconfidentialdocumentsfrom publicdisclosureindefinitely. Thesedocumentscontaindetailedsystemandequipmentdescriptionsandareconsideredasproprietary informationinoperationoftheequipment.Thepublicdisclosureofthesedocumentsmightbeharmfulto ourcompanyandwouldgivecompetitorsanunfairadvantageinthemarket. SchematicDiagram BlockDiagram PartsList OperationalDescription Tune-upProcedure Itisourunderstandingthatallmeasurementtestreports,FCCIDlabelformatandcorrespondenceduring thecertificationreviewprocesscannotbegrantedasconfidentialdocumentsandthisinformationwillbe availableforpublicreviewoncethegrantofequipmentauthorizationisissued. Sincerely, Signature: Name:SaraLuo Title:Manager
SHENZHENBWAYTECHCO.,LTD LetterofAuthorization Company:SHENZHENBWAYTECHCO.,LTD Address:FL3,BLDGA,NO4,LONGSHAN4THRD,LUOTIANCOMMUNITY ShenzhenChina ProductName:IONUVPROPHONESANITIZER ModelNumber:7609 SerialModel:N/A FCCIdentifier:2AWFB-KCWSC WeauthorizeMiCOMLabsInc,575BoulderCourt,Pleasanton,California94566, USA,toactonourbehalfonallmattersconcerningtheabovenamedequipment. AnyindividualwithinMiCOMLabsisauthorizedtoactonourbehalfandtake actionontheapplication. WedeclarethatMiCOMLabsInc,575BoulderCourt,Pleasanton,California 94566,USA,isallowedtoforwardallinformationrelatedtotheapprovalproject totheFederalCommunicationCommissionandtodiscussanyissues concerningtheapprovalapplication.AnyandallactscarriedoutbyMiCOMLabs onourbehalfshallhavethesameeffectasactsofourown. Name:SaraLuoDate:Aug.17,2020 Title:Manager Signatureofapplicant:
ModelDifferenceDeclaration ToWhomItMayConcern, We,SHENZHENBWAYTECHCO.,LTD Product:IONUVPROPHONESANITIZER Trademark:N/A ModelNumber:7609,7565,BW-UV-01 Allmodelāsthefunction,softwareandelectriccircuitarethesame,onlywitha productcolorandmodelnameddifferent.Testsamplemodel:7609. Pleasecontactmeifyouhaveanyquestion. Name:SaraLuo Date: Aug.17,2020 Title:Manager Signatureofapplicant:
Model:7609 Model:7609 Model:7609 Model:7609
FCCIDLABEL: LabelLocation: FCCID:2AWFB-KCWSC Productname:IONUVPROPHONESANITIZER ModelNo.:7609 ThisdevicecomplieswithPart15oftheFCCRules.Operationissubjecttothe followingtwoconditions: (1)Thisdevicemaynotcauseharmfulinterference (2)Thisdevicemustacceptanyinterferencereceived,includinginterferencethat maycauseundesiredoperation. Long:3cm Width:2cm
Model:7609 Model:7609 Model:7609 Model:7609 Model:7609 CoilAntenna :
Report No.:UNIA20061308ER-02 Page1 / 7 FCC MPE TEST REPORT FCC ID: 2AWFB-KCWSC Product ļ¼ ION UV PRO PHONE SANITIZER Trade Name ļ¼N/A Model Nameļ¼7609 Serial Model ļ¼ 7565, BW-UV-01 Report No. ļ¼ UNIA20061308ER-02 Prepared for SHENZHEN BWAY TECH CO.,LTD FL 3, BLDG A, NO 4, LONGSHAN 4TH RD, LUOTIAN COMMUNITY Shenzhen China Prepared by Shenzhen United Testing Technology Co., Ltd. 2F, Annex Bldg, Jiahuangyuan Tech Park, #365 Baotian 1 Rd, Tiegang Community, Xixiang Str, Bao'an District, Shenzhen, China ReportNo.:UNIA20061308ER-02 Page2/7 TESTRESULTCERTIFICATION Applicantāsname................: SHENZHENBWAYTECHCO.,LTD Address..................................: FL3,BLDGA,NO4,LONGSHAN4THRD,LUOTIAN COMMUNITYShenzhenChina Manufacture'sName .......... : SHENZHENBWAYTECHCO.,LTD Address..................................: FL3,BLDGA,NO4,LONGSHAN4THRD,LUOTIAN COMMUNITYShenzhenChina Productdescription Productname........................: IONUVPROPHONESANITIZER TradeMark ................................. : N/A Modeland/ortypereference.: 7609,7565,BW-UV-01 Standards.............................: FCCKDB680106D01RFExposureWirelessCharging Appsv03 ThisdevicedescribedabovehasbeentestedbyShenzhenUnitedTestingTechnology Co.,Ltd.,andthetestresultsshowthattheequipmentundertest(EUT)isincompliance withtheFCCrequirements.Anditisapplicableonlytothetestedsampleidentifiedinthe report. Thisreportshallnotbereproducedexceptinfull,withoutthewrittenapprovalofUNI,this documentmaybealteredorrevisedbyShenzhenUnitedTestingTechnologyCo.,Ltd., personnelonly,andshallbenotedintherevisionofthedocument. DateofTest...............................................: Date(s)ofperformanceoftests...............: Jun.13,2020~Aug.11,2020 DateofIssue .............................................. : Aug.11,2020 TestResult..................................................:Pass Preparedby: Bobliao/Editor Reviewer: Kahnyang/Supervisor Approved&AuthorizedSigner: Liuze/Manager ReportNo.:UNIA20061308ER-02 Page3/7 Note: Foramoredetailedfeaturesdescription,pleaserefertothemanufacturerāsspecifications or theUser'sManual. ChannelList ChannelFrequency(KHz)ChannelFrequency(MHz) 01125 TheEUTantennaisCoilAntenna.Noantennaotherthanthatfurnishedbytheresponsibleparty shallbeusedwiththedevice. 1.SUMMARYOFTESTRESULTS 1.1Testproceduresaccordingtothetechnicalstandards: FCCKDB680106D01RFExposureWirelessChargingAppsv03 FCCCFR47 StandardSectionTestItemJudgmentRemark FCCCFR47part1, 1.1310KDB680106 D01v03(3)(3) ElectricFieldStrength(E)(V/m)PASS MagneticFieldStrength(H)(A/m)PASS ReportNo.:UNIA20061308ER-02 Page4/7 1.2MEASUREMENTUNCERTAINTY Thereporteduncertaintyofmeasurementy±Uļ¼whereexpendeduncertaintyUisbased onastandarduncertaintymultipliedbyacoveragefactorofk=2ļ¼providingalevelof confidenceofapproximately95%ć No.ItemUncertainty 1Allemissions,radiated(<30M)(9KHz-30MHz)±2.45dB 2Temperature±0.5°C 3Humidity±2% 1.3TestInstruments DescriptionBrandModelNo.FrequencyRangeCalibratedUntil BroadbandFieldMeterNARDANBM-550āāSep.01,2020 MagneticFieldMeterNARDAELT-4001ā400kHzSep.01,2020 MagneticProbeNARDAHF-3061300kHzā30MHzSep.01,2020 MagneticProbeNARDAHF-019127ā1000MHzSep.01,2020 BroadbandFieldMeterNARDANBM-550āāSep.01,2020 ElectricFieldMeterCOMBINOVAEFM2005Hzā400kHzSep.01,2020 E-FieldProbeNARDAEF-0391100kHzā3GHzSep.01,2020 E-FieldProbeNARDAEF-6091100MHzā60GHzSep.01,2020 NOTE:Thecalibrationintervaloftheabovetestinstrumentsis12months. ReportNo.:UNIA20061308ER-02 Page5/7 2MAXIMUMPERMISSIBLEEXPOSURE 2.1MAXIMUMPERMISSIBLEEXPOSURE LimitofMaximumPermissibleExposure LimitsforOccupational/ControlledExposure FrequencyRange(M Hz) ElectricFieldStrengt h(E)(V/m) MagneticField Strength(H)(A/m) PowerDensity(S) (mW/cm²) AveragingTime |E|²,|H|²orS (minutes) 0.3-3.0 6141.63(100)*6 3.0-30 1842/f4.89/f(900/f)* 6 30-300 61.40.1631.06 300-1500 F/3006 1500-100,000 56 LimitsforGeneralPopulation/UncontrolledExposure FrequencyRange(M Hz) ElectricFieldStrengt h(E)(V/m) MagneticFieldStreng th(H)(A/m) Power Density(S)(mW/cm² ) AveragingTime |E|²,|H|² orS(minutes) 0.3-1.34 6141.63 (100)* 30 1.34-30 824/f2.19/f (180/f)* 30 30-300 27.50.073 0.2 30 300-1500F/1500 30 1500-100,0001 30 Note1:f=frequencyinMHz;*Plane-waveequivalentpowerdensity. 2:Fortheapplicablelimit,seeFCC1.1310,680106D01RFExposureWirelessChargingAppsv03. 3:Emissionsbetween100kHzto300kHzshouldbeassessedversusthelimitsat300kHzinTable1of Section1.1310:614V/mand1.63A/m.AKDBinquiryisrequiredtodeterminetheapplicableexposure limitsbelow100kHz. ReportNo.:UNIA20061308ER-02 Page6/7 3.TESTPROCEDURE a.Fordevicesdesignedfortypicaldesktopapplications,suchawirelesscharging pads,RFexposureevaluationshouldbeconductedassumingauserseparationdistanceof15 cm. EandHfieldstrengthmeasurementsornumericalmodelingmaybeused todemonstratecompliance.Measurementsshouldbemadefromallsidesandthetopof theprimary/clientpairatthe15cmsurroundingthedeviceand20cmabovethetopsurface. 4.1TESTSETUP 4.2TESTPHOTO ReportNo.:UNIA20061308ER-02 Page7/7 4.3RESULTOFMAXIMUMPERMISSIBLEEXPOSURE ForFullloadmode: E-FiledStrengthat15cmsurroundingthedeviceand20cmabovethetopsurface(V/m) Frequency Range(MHz) Test PositionA Test PositionB Test PositionC Test PositionD Test PositionE Reference Limit(V/m) LimitsTest (V/m) 0.1251.201.191.141.121.15307614 H-FiledStrengthat15cmsurroundingthedeviceand20cmabovethetopsurface(A/m) Frequency Range(MHz) Test PositionA Test PositionB Test PositionC Test PositionD Test PositionE Reference Limit(A/m) LimitsTest (A/m) 0.1250.270.280.260.200.180.8151.63 ForHalfLoadmode: E-FiledStrengthat15cmsurroundingthedeviceand20cmabovethetopsurface(V/m) Frequency Range(MHz) Test PositionA Test PositionB Test PositionC Test PositionD Test PositionE Reference Limit(V/m) LimitsTest (V/m) 0.1251.251.121.141.071.10307614 H-FiledStrengthat15cmsurroundingthedeviceand20cmabovethetopsurface(A/m) Frequency Range(MHz) Test PositionA Test PositionB Test PositionC Test PositionD Test PositionE Reference Limit(A/m) LimitsTest (A/m) 0.1250.220.200.200.220.170.8151.63 ForNoloadmode: E-FiledStrengthat15cmsurrouā¦
Text truncated - open the document above for the full version.
Page1of18ReportNo.:UNIA20061308ER-01 FCCRADIOTESTREPORT FCCID:2AWFB-KCWSC Product ļ¼ IONUVPROPHONESANITIZER TradeName ļ¼ N/A ModelNameļ¼ 7609 SerialModelļ¼ 7565,BW-UV-01 ReportNo. ļ¼ UNIA20061308ER-01 Preparedfor SHENZHENBWAYTECHCO.,LTD FL3,BLDGA,NO4,LONGSHAN4THRD,LUOTIANCOMMUNITY ShenzhenChina Preparedby ShenzhenUnitedTestingTechnologyCo.,Ltd. 2F,AnnexBldg,JiahuangyuanTechPark,#365Baotian1Rd,Tiegang Community,XixiangStr,Bao'anDistrict,Shenzhen,China Page2of18ReportNo.:UNIA20061308ER-01 TESTRESULTCERTIFICATION Applicantāsname....................: SHENZHENBWAYTECHCO.,LTD Address......................................: FL3,BLDGA,NO4,LONGSHAN4THRD,LUOTIAN COMMUNITYShenzhenChina Manufacture'sName..............: SHENZHENBWAYTECHCO.,LTD Address......................................: FL3,BLDGA,NO4,LONGSHAN4THRD,LUOTIAN COMMUNITYShenzhenChina Productdescription Productname............................... : IONUVPROPHONESANITIZER TradeMark.................................: N/A Modeland/ortypereference . : 7609,7565,BW-UV-01 Standards..................................: FCCRulesandRegulationsPart15SubpartCSection15.209 ANSIC63.10:2013 ThisdevicedescribedabovehasbeentestedbyShenzhenUnitedTestingTechnology Co.,Ltd.,andthetestresultsshowthattheequipmentundertest(EUT)isincompliance withtheFCCrequirements.Anditisapplicableonlytothetestedsampleidentifiedinthe report. Thisreportshallnotbereproducedexceptinfull,withoutthewrittenapprovalofUNI,this documentmaybealteredorrevisedbyShenzhenUnitedTestingTechnologyCo.,Ltd., personnelonly,andshallbenotedintherevisionofthedocument. DateofTest...............................................: Date(s)ofperformanceoftests...............: Jun.13,2020~Aug.11,2020 DateofIssue..............................................: Aug.11,2020 TestResult .................................................. :Pass Preparedby: Bobliao/Editor Reviewer: Kahnyang/Supervisor Approved&AuthorizedSigner: Liuze/Manager Page3of18ReportNo.:UNIA20061308ER-01 TableofContentsPage 1TESTSUMMARY....................................................................................................................4 2GENERALINFORMATION....................................................................................................5 2.1GENERALDESCRIPTIONOFEUT.........................................................................................5 2.2CarrierFrequencyofChannels.................................................................................................6 2.3OperationofEUTduringtesting................................................................................................6 2.4DESCRIPTIONOFTESTSETUP..............................................................................................6 2.5MEASUREMENTINSTRUMENTSLIST...................................................................................7 3CONDUCTEDEMISSIONTEST ........................................................................................... 8 3.1ConductedPowerLineEmissionLimit.....................................................................................8 3.2TestSetup.....................................................................................................................................8 3.3TestProcedure.............................................................................................................................8 3.4TestResult....................................................................................................................................8 4RADIATEDEMISSIONTEST..............................................................................................11 4.1BlockDiagramofTestSetup .................................................................................................... 11 4.2Rulesandspecifications ........................................................................................................... 12 4.3TestProcedure ........................................................................................................................... 13 4.4TestResult .................................................................................................................................. 13 5ANTENNAREQUIREMENT................................................................................................16 6PHOTOGRAPHOFTEST ..................................................................................................... 17 6.1RadiatedEmission.....................................................................................................................17 6.2ConductedEmission.................................................................................................................18 Page4of18ReportNo.:UNIA20061308ER-01 1TESTSUMMARY TESTPROCEDURESANDRESULTS DESCRIPTIONOFTESTSTANGARDRESULT CONDUCTEDEMISSIONTESTFCCPart15.207COMPLIANT RADIATEDEMISSIONTESTFCCPart15.209COMPLIANT ANTENNAREQUIREMENTFCCPart15.203COMPLIANT TESTFACILITY TestFirm:ShenzhenUnitedTestingTechnologyCo.,Ltd. Address:2F,AnnexBldg,JiahuangyuanTechPark,#365Baotian1Rd,Tiegang Community,XixiangStr,Bao'anDistrict,Shenzhen,China Thetestingqualityabilityofourlaboratorymeetwith"QualityLawofPeople'sRepublicof China"Clause19.ThetestingqualitysystemofourlaboratorymeetswithISO/IEC-17025 requirements.ThisapprovalresultisacceptedbyMRAofAPLAC. Ourtestfacilityisrecognized,certified,oraccreditedbythefollowingorganizations: A2LACertificateNumber:4747.01 TheEMCLaboratoryhasbeenaccreditedbyA2LA,andincompliancewithISO/IEC 17025:2017GeneralRequirementsfortestingLaboratories. FCCRegistrationNumber:674885 TheEMCLaboratoryhasbeenregisteredandfullydescribedinareportfiledwiththe(FCC) FederalCommunicationscommission. ICRegistrationNumber:21947 TheEMCLaboratoryhasbeenregisteredandfullydescribedinareportfiledwiththe(IC) IndustryCanada. MEASUREMENTUNCERTAINTY MeasurementUncertainty ConductedEmissionExpandedUncertainty=2.23dB,k=2 Radiatedemissionexpandeduncertainty(9kHz-30MHz)= 3.08dB,k=2 Radiatedemissā¦
Text truncated - open the document above for the full version.
Model:7609 Model:7609
| # | Rule Parts | Frequency Range | Power Output |
|---|---|---|---|
| 1 | 15C | 0.125 MHz - 0.125 MHz | - |

MEGABASS LED JOBSITE SPEAKER
Equipment Class
DTS - Digital Transmission System