FCCID.CO- FCC ID Database
HomeCompaniesEquipment ClassesSearch

© 2026 FCC ID Database. All rights reserved.

AboutContactData sourced from FCC public records
  1. Home/
  2. GOLABS INC./
  3. 2AWFV-MARSMAX

2AWFV-MARSMAXA SMARTER HOVERBOARD

GOLABS INC.
A SMARTER HOVERBOARD - FCC ID 2AWFV-MARSMAX - GOLABS INC.
Click to zoom

Application Details

Equipment Class
DSS - Part 15 Spread Spectrum Transmitter
Date of Grant
Oct 29, 2023
Application Purpose
Original Equipment
Date of Application
Oct 29, 2023
Equipment Note
A SMARTER HOVERBOARD
Frequency Range
2402.00000000 - 2480.00000000
Company
GOLABS INC.
Country
United States

Documents & Files

Select a file to view

Users Manual

↗

Attestation Statements

↗
↗

Cover Letter(s)

↗
↗
↗

External Photos

↗

ID Label/Location Info

↗

Internal Photos

↗

RF Exposure Info

↗

Test Report

↗
↗

Test Setup Photos

↗

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

Attestation Statements

GOLABS INC. Covered Equipment Certification Attestation Letter 10/19/2023 Nemko North America, Inc. 303 River Road Ottawa K1V 1H2 Canada ATTN.: Reviewing Engineer FCC ID: 2AWFV-MARSMAX GOLABS INC. (“the applicant”) certifies that the equipment for which authorization is sought is not “covered” equipment prohibited from receiving an equipment authorization pursuant to section 2.903 of the FCC rules. Note: If the equipment for which the applicant seeks authorization is produced by any of the entities identified on the current Covered List, the applicant should include an explanation on why the equipment is not “covered” equipment. GOLABS INC. (“the applicant”) certifies that, as of the date of the filing of the application, the applicant is not identified on the Covered List as an entity producing “covered” equipment. Signed: Printed name: Zhenshan Ding Title: CEO Company Name: GOLABS INC. Date: 10/19/2023

External Photos

Bureau Veritas Shenzhen Co., Ltd. Dongguan Branch No. 96, Guantai Road (Houjie Section), Houjie Town, Dongguan City, Guangdong Province. 523942. People’s Republic of China. Tel.: +86 769 8998 2098 Fax: +86 769 8593 1080 Email: [email protected] Page 1 of 5 Report Version A Reference No.: 2309WDG0052 PHOTOGRAPHS OF THE EUT Bureau Veritas Shenzhen Co., Ltd. Dongguan Branch No. 96, Guantai Road (Houjie Section), Houjie Town, Dongguan City, Guangdong Province. 523942. People’s Republic of China. Tel.: +86 769 8998 2098 Fax: +86 769 8593 1080 Email: [email protected] Page 2 of 5 Report Version A Reference No.: 2309WDG0052 Bureau Veritas Shenzhen Co., Ltd. Dongguan Branch No. 96, Guantai Road (Houjie Section), Houjie Town, Dongguan City, Guangdong Province. 523942. People’s Republic of China. Tel.: +86 769 8998 2098 Fax: +86 769 8593 1080 Email: [email protected] Page 3 of 5 Report Version A Reference No.: 2309WDG0052 Bureau Veritas Shenzhen Co., Ltd. Dongguan Branch No. 96, Guantai Road (Houjie Section), Houjie Town, Dongguan City, Guangdong Province. 523942. People’s Republic of China. Tel.: +86 769 8998 2098 Fax: +86 769 8593 1080 Email: [email protected] Page 4 of 5 Report Version A Reference No.: 2309WDG0052 Bureau Veritas Shenzhen Co., Ltd. Dongguan Branch No. 96, Guantai Road (Houjie Section), Houjie Town, Dongguan City, Guangdong Province. 523942. People’s Republic of China. Tel.: +86 769 8998 2098 Fax: +86 769 8593 1080 Email: [email protected] Page 5 of 5 Report Version A Reference No.: 2309WDG0052

ID Label/Location Info

The label is attached to the bottom plate. FCC ID: 2AWFV-MARSMAX MARS MAX 36V 2.6Ah DC 42V 0.85A MARS MAX

Internal Photos

Bureau Veritas Shenzhen Co., Ltd. Dongguan Branch No. 96, Guantai Road (Houjie Section), Houjie Town, Dongguan City, Guangdong Province. 523942. People’s Republic of China. Tel.: +86 769 8998 2098 Fax: +86 769 8593 1080 Email: [email protected] Page 1 of 9 Report Version A Reference No.: 2309WDG0052 PHOTOGRAPHS OF THE EUT Bureau Veritas Shenzhen Co., Ltd. Dongguan Branch No. 96, Guantai Road (Houjie Section), Houjie Town, Dongguan City, Guangdong Province. 523942. People’s Republic of China. Tel.: +86 769 8998 2098 Fax: +86 769 8593 1080 Email: [email protected] Page 2 of 9 Report Version A Reference No.: 2309WDG0052 Bureau Veritas Shenzhen Co., Ltd. Dongguan Branch No. 96, Guantai Road (Houjie Section), Houjie Town, Dongguan City, Guangdong Province. 523942. People’s Republic of China. Tel.: +86 769 8998 2098 Fax: +86 769 8593 1080 Email: [email protected] Page 3 of 9 Report Version A Reference No.: 2309WDG0052 Bureau Veritas Shenzhen Co., Ltd. Dongguan Branch No. 96, Guantai Road (Houjie Section), Houjie Town, Dongguan City, Guangdong Province. 523942. People’s Republic of China. Tel.: +86 769 8998 2098 Fax: +86 769 8593 1080 Email: [email protected] Page 4 of 9 Report Version A Reference No.: 2309WDG0052 Bureau Veritas Shenzhen Co., Ltd. Dongguan Branch No. 96, Guantai Road (Houjie Section), Houjie Town, Dongguan City, Guangdong Province. 523942. People’s Republic of China. Tel.: +86 769 8998 2098 Fax: +86 769 8593 1080 Email: [email protected] Page 5 of 9 Report Version A Reference No.: 2309WDG0052 BT ANT Bureau Veritas Shenzhen Co., Ltd. Dongguan Branch No. 96, Guantai Road (Houjie Section), Houjie Town, Dongguan City, Guangdong Province. 523942. People’s Republic of China. Tel.: +86 769 8998 2098 Fax: +86 769 8593 1080 Email: [email protected] Page 6 of 9 Report Version A Reference No.: 2309WDG0052 Bureau Veritas Shenzhen Co., Ltd. Dongguan Branch No. 96, Guantai Road (Houjie Section), Houjie Town, Dongguan City, Guangdong Province. 523942. People’s Republic of China. Tel.: +86 769 8998 2098 Fax: +86 769 8593 1080 Email: [email protected] Page 7 of 9 Report Version A Reference No.: 2309WDG0052 Bureau Veritas Shenzhen Co., Ltd. Dongguan Branch No. 96, Guantai Road (Houjie Section), Houjie Town, Dongguan City, Guangdong Province. 523942. People’s Republic of China. Tel.: +86 769 8998 2098 Fax: +86 769 8593 1080 Email: [email protected] Page 8 of 9 Report Version A Reference No.: 2309WDG0052 Bureau Veritas Shenzhen Co., Ltd. Dongguan Branch No. 96, Guantai Road (Houjie Section), Houjie Town, Dongguan City, Guangdong Province. 523942. People’s Republic of China. Tel.: +86 769 8998 2098 Fax: +86 769 8593 1080 Email: [email protected] Page 9 of 9 Report Version A Reference No.: 2309WDG0052

RF Exposure Info

Bureau Veritas Shenzhen Co., Ltd. Dongguan Branch No. 96, Guantai Road (Houjie Section), Houjie Town, Dongguan City, Guangdong Province. 523942. People’s Republic of China. Tel: +86 769 8998 2098 Fax: +86 769 8593 1080 Email: [email protected] Page 1 of 6 Report Version 1 Test Report No.: FM2309WDG0052 RF EXPOSURE REPORT Applicant GOLABS INC. Address 2201 LUNA RD CARROLLTON, TX 75006 Manufacturer or Supplier ZHEJIANG TAOTAO VEHICLES CO., LTD Address No.10 XINYUAN ROAD, XINBI STREET, JINYUN COUNTY LISHUI City ZHEJIANG 321400 CHINA Product A SMARTER HOVERBOARD Brand Name GOTRAX Model MARS MAX Additional Models & Model Difference PB-628-1, See items 1 Date of tests Sep. 11, 2023 ~ Sep. 19, 2023 FCC Part 2 (Section 2.1093) KDB 447498 D01 V06 IEEE C95.1 CONCLUSION: The submitted sample was found to COMPLY with the test requirement Tested by Loren Luo Project Engineer / EMC Department Approved by Glyn He Assistant Manager / EMC Department Date: Oct. 20, 2023 This report is governed by, and incorporates by reference, the Conditions of Testing as posted at the date of issuance of this report at http://www.bureauveritas.com/home/about-us/our-business/cps/about-us/terms-conditions/ and is intended for your exclusive use. Any copying or replication of this report to or for any other person or entity, or use of our name or trademark, is permitted only with our prior written permission. This report sets forth our findings solely with respect to the test samples identified herein. The results set forth in this report are not indicative or representative of the quality or characteristics of the lot from which a test sample was taken or any similar or identical product unless specifically and expressly noted. Our report includes all of the tests requested by you and the results thereof based upon the information that you provided to us. Measurement uncertainty is only provided upon request for accredited tests. Statements of conformity are based on simple acceptance criteria without taking measurement uncertainty into account, unless otherwise requested in writing. You have 60 days from date of issuance of this report to notify us of any material error or omission caused by our negligence or if you require measurement uncertainty; provided, however, that such notice shall be in writing and shall specifically address the issue you wish to raise. A failure to raise such issue within the prescribed time shall constitute your unqualified acceptance of the completeness of this report, the tests conducted and the correctness of the report contents. Bureau Veritas Shenzhen Co., Ltd. Dongguan Branch No. 96, Guantai Road (Houjie Section), Houjie Town, Dongguan City, Guangdong Province. 523942. People’s Republic of China. Tel: +86 769 8998 2098 Fax: +86 769 8593 1080 Email: [email protected] Page 2 of 6 Report Version 1 Test Report No.: FM2309WDG0052 TABLE OF CONTENTS RELEASE CONTROL RECORD ................................................................................ 3 1. CERTIFICATION .............................................................................................. 4 2. RF EXPOSURE DEFINE ................................................................................. 5 3. CLASSIFICATION ........................................................................................... 5 4. SAR TEST EXCLUSION THRESHOLDS ........................................................ 6 Bureau Veritas Shenzhen Co., Ltd. Dongguan Branch No. 96, Guantai Road (Houjie Section), Houjie Town, Dongguan City, Guangdong Province. 523942. People’s Republic of China. Tel: +86 769 8998 2098 Fax: +86 769 8593 1080 Email: [email protected] Page 3 of 6 Report Version 1 Test Report No.: FM2309WDG0052 RELEASE CONTROL RECORD ISSUE NO. REASON FOR CHANGE DATE ISSUED FM2309WDG0052 Original release Oct. 20, 2023 Bureau Veritas Shenzhen Co., Ltd. Dongguan Branch No. 96, Guantai Road (Houjie Section), Houjie Town, Dongguan City, Guangdong Province. 523942. People’s Republic of China. Tel: +86 769 8998 2098 Fax: +86 769 8593 1080 Email: [email protected] Page 4 of 6 Report Version 1 Test Report No.: FM2309WDG0052 1. CERTIFICATION FCC ID: 2AWFV-MARSMAX PRODUCT: A SMARTER HOVERBOARD BRAND NAME: GOTRAX MODEL NO.: MARS MAX ADDITIONAL NO.: PB-628-1 APPLICANT: GOLABS INC. STANDARDS: FCC Part 2 (Section 2.1093) KDB 447498 D01 V06 IEEE C95.1 NOTES:Additional model PB-628-1 is identical with the test model MARS MAX except the color of the appearance, product name and model number for trading purpose. Bureau Veritas Shenzhen Co., Ltd. Dongguan Branch No. 96, Guantai Road (Houjie Section), Houjie Town, Dongguan City, Guangdong Province. 523942. People’s Republic of China. Tel: +86 769 8998 2098 Fax: +86 769 8593 1080 Email: [email protected] Page 5 of 6 Report Version 1 Test Report No.: FM2309WDG0052 2. RF EXPOSURE DEFINE The corresponding SAR Exclusion Threshold condition, listed below: 1) The 1-g and 10-g SAR test exclusion thresholds for 100 MHz to 6 GHz at test separation distances ≤ 50 mm are determined by: [(max. power of channel, including tune-up tolerance, mW)/(min. test separation distance, mm)] ·[ √f(GHz)] ≤ 3.0 for 1-g SAR and ≤ 7.5 for 10-g extremity SAR,16 where   f(GHz) is the RF channel transmit frequency in GHz   Power and distance are rounded to the nearest mW and mm before calculation   The result is rounded to one decimal place for comparison The test exclusions are applicable only when the minimum test separation distance is ≤ 50 mm and for transmission frequencies between 100 MHz and 6 GHz. When the minimum test separation distance is < 5 mm, a distance of 5 mm is applied to determine SAR test exclusion. 2) At 100 MHz to 6 GHz and for test separation distances > 50 mm, the SAR test exclusion threshold is determined according to the following: a) [Threshold at 50 mm in step 1) + (test separation distance - 50 mm)·( f(MHz)/150)]…

Text truncated - open the document above for the full version.

Test Report

productmodelname_antennamodelname_PCBAntenna Manufacturers:ShenzhenYueshitongTechnologyCo.,Ltd. TestEquipment:XXXX 1.ElectricalCharacteristics No. ItemSpecifications 1 WorkingCentralFrequency 2450MHz 2 BandWidth 2400~2500MHZ 3 Gain 0~2dbi 4 V.S.W.R(inBW) 2.0 5 Polarization Linear 6 AzimuthBeamwidth Omni-directional 7 Impedance 50 Address:5th Floor, Building 2, Hongchong Industrial Park, Longxi Community, Longgang Street, Longgang District, Shenzhen 2.ReturnLossandSmithChat 3PhysicalTestEnvironment AntitsuS332D 4.Shapeoftheantenna 5RadiationPattern Efficiency/Gain-WIFI2.4G

Test Report

Bureau Veritas Shenzhen Co., Ltd. Dongguan Branch No. 96, Guantai Road (Houjie Section), Houjie Town, Dongguan City, Guangdong Province. 523942. People’s Republic of China. Tel: +86 769 8998 2098 Fax: +86 769 8593 1080 Email: [email protected] Page 1 of 58 Report Version A Test Report No.: RF2309WDG0052 TEST REPORT Applicant GOLABS INC. Address 2201 LUNA RD CARROLLTON, TX 75006 Manufacturer or Supplier ZHEJIANG TAOTAO VEHICLES CO., LTD Address No.10 XINYUAN ROAD, XINBI STREET, JINYUN COUNTY LISHUI City ZHEJIANG 321400 CHINA Product A SMARTER HOVERBOARD Brand Name GOTRAX Model MARS MAX Additional Model & Model Difference PB-628-1, See items 3.1 Date of tests Sep. 11, 2023 ~ Sep. 19, 2023 the tests have been carried out according to the requirements of the following standards: FCC Part 15, Subpart C, Section 15.247 CONCLUSION: The submitted sample was found to COMPLY with the test requirement Tested by Loren Luo Project Engineer / EMC Department Approved by Glyn He Assistant Manager / EMC Department Date: Oct. 20, 2023 This report is governed by, and incorporates by reference, the Conditions of Testing as posted at the date of issuance of this report at http://www.bureauveritas.com/home/about-us/our-business/cps/about-us/terms-conditions/ and is intended for your exclusive use. Any copying or replication of this report to or for any other person or entity, or use of our name or trademark, is permitted only with our prior written permission. This report sets forth our findings solely with respect to the test samples identified herein. The results set forth in this report are not indicative or representative of the quality or characteristics of the lot from which a test sample was taken or any similar or identical product unless specifically and expressly noted. Our report includes all of the tests requested by you and the results thereof based upon the information that you provided to us. Measurement uncertainty is only provided upon request for accredited tests. Statements of conformity are based on simple acceptance criteria without taking measurement uncertainty into account, unless otherwise requested in writing. You have 60 days from date of issuance of this report to notify us of any material error or omission caused by our negligence or if you require measurement uncertainty; provided, however, that such notice shall be in writing and shall specifically address the issue you wish to raise. A failure to raise such issue within the prescribed time shall constitute your unqualified acceptance of the completeness of this report, the tests conducted and the correctness of the report contents. Bureau Veritas Shenzhen Co., Ltd. Dongguan Branch No. 96, Guantai Road (Houjie Section), Houjie Town, Dongguan City, Guangdong Province. 523942. People’s Republic of China. Tel: +86 769 8998 2098 Fax: +86 769 8593 1080 Email: [email protected] Page 2 of 58 Report Version A Test Report No.: RF2309WDG0052 TABLE OF CONTENTS RELEASE CONTROL RECORD ..................................................................................................... 5 1 SUMMARY OF TEST RESULTS ............................................................................................. 6 2 MEASUREMENT UNCERTAINTY .......................................................................................... 6 3 GENERAL INFORMATION ..................................................................................................... 7 3.1 GENERAL DESCRIPTION OF EUT .................................................................................... 7 3.2 DESCRIPTION OF TEST MODES ...................................................................................... 8 3.2.1. CONFIGURATION OF SYSTEM UNDER TEST ........................................................ 9 3.2.2. TEST MODE APPLICABILITY AND TESTED CHANNEL DETAIL ............................. 9 3.3 GENERAL DESCRIPTION OF APPLIED STANDARDS .................................................... 11 3.4 DESCRIPTION OF SUPPORT UNITS ............................................................................... 11 3.5 CONFIGURATION OF SYSTEM UNDER TEST ................................................................ 11 3.6 DUTY CYCLE OF TESET SIGNAL ................................................................................... 12 4 TEST TYPES AND RESULTS ............................................................................................... 13 4.1. CONDUCTED EMISSION MEASUREMENT ................................................................ 13 4.1.1 LIMITS OF CONDUCTED EMISSION MEASUREMENT ........................................ 13 4.1.2 TEST INSTRUMENTS .............................................................................................. 13 4.1.3 TEST PROCEDURES .............................................................................................. 14 4.1.4 DEVIATION FROM TEST STANDARD .................................................................... 14 4.1.5 TEST SETUP ............................................................................................................ 15 4.1.6 EUT OPERATING CONDITIONS ............................................................................. 15 4.1.7 TEST RESULTS........................................................................................................ 16 4.2. RADIATED EMISSION AND BANDEDGE MEASUREMENT........................................ 18 4.2.1 LIMITS OF RADIATED EMISSION AND BANDEDGE MEASUREMENT ................ 18 4.2.2 TEST INSTRUMENTS .............................................................................................. 19 4.2.3 TEST PROCEDURES .............................................................................................. 20 4.2.4 DEVIATION FROM TEST STANDARD .................................................................... 21 4.2.5 TEST SETUP ....................................................................…

Text truncated - open the document above for the full version.

Test Setup Photos

Bureau Veritas Shenzhen Co., Ltd. Dongguan Branch No. 96, Guantai Road (Houjie Section), Houjie Town, Dongguan City, Guangdong Province. 523942. People’s Republic of China. Tel.: +86 769 8998 2098 Fax: +86 769 8593 1080 Email: [email protected] Page 1 of 3 Report Version A Reference No.: 2309WDG0052 SET-UP FOR CONDUCTED EMISSION TEST Bureau Veritas Shenzhen Co., Ltd. Dongguan Branch No. 96, Guantai Road (Houjie Section), Houjie Town, Dongguan City, Guangdong Province. 523942. People’s Republic of China. Tel.: +86 769 8998 2098 Fax: +86 769 8593 1080 Email: [email protected] Page 2 of 3 Report Version A Reference No.: 2309WDG0052 SET-UP FOR RADIATED EMISSION TEST Frequency Range< 30MHz~1GHz > Bureau Veritas Shenzhen Co., Ltd. Dongguan Branch No. 96, Guantai Road (Houjie Section), Houjie Town, Dongguan City, Guangdong Province. 523942. People’s Republic of China. Tel.: +86 769 8998 2098 Fax: +86 769 8593 1080 Email: [email protected] Page 3 of 3 Report Version A Reference No.: 2309WDG0052 Frequency Range< Above 1GHz >

Contact Information

Applicant

Zhenshan Ding(CEO)
[email protected]7735519922Fax: 214-635-3985

Test Firm

Bureau Veritas Shenzhen Co., Ltd. Dongguan BranchEdwin Ye
[email protected]86-20-8714 8549

Technical Specifications

#Rule PartsFrequency RangePower Output
115C2.40 GHz - 2.48 GHz1.21 mW
Confidentiality
Long Term
Grant Notes
Output power is conducted. End-users and installers must be provided with antenna installation and transmitter operating conditions for satisfying RF exposure compliance.

Other Applications from GOLABS INC.

2AWFV-MK2

ELECTRIC DIRT BIKE

Jul 30, 2026

Equipment Class

DSS - Part 15 Spread Spectrum Transmitter
2AWFV-WG1

Electric Wiggle Car for Kids

Sep 30, 2025

Equipment Class

DSS - Part 15 Spread Spectrum Transmitter
ELECTRIC SCOOTER - FCC ID 2AWFV-T6 - GOLABS INC.
2AWFV-T6

ELECTRIC SCOOTER

Aug 18, 2024

Equipment Class

DSS - Part 15 Spread Spectrum Transmitter
A SMART OFFROAD HOVERBOARD - FCC ID 2AWFV-COSMOS - GOLABS INC.
2AWFV-COSMOS

A SMART OFFROAD HOVERBOARD

Aug 14, 2024

Equipment Class

DSS - Part 15 Spread Spectrum Transmitter
ELECTRIC SCOOTER - FCC ID 2AWFV-T7 - GOLABS INC.
2AWFV-T7

ELECTRIC SCOOTER

Aug 13, 2024

Equipment Class

DSS - Part 15 Spread Spectrum Transmitter