2AWGS-BT919Infrared Forehead Thermometer

Shenzhen Gainstrong Technology Co., Ltd.
Infrared Forehead Thermometer - FCC ID 2AWGS-BT919 - Shenzhen Gainstrong Technology Co., Ltd.
Click to zoom

Application Details

Equipment Class
8CC - Part 18 Consumer Device
Date of Grant
May 27, 2020
Application Purpose
Original Equipment
Date of Application
May 27, 2020
Equipment Note
Infrared Forehead Thermometer
Frequency Range
2400.00000000 - 2483.50000000
Company
Shenzhen Gainstrong Technology Co., Ltd.
Country
China

Documents & Files

Select a file to view

Users Manual

↗

Cover Letter(s)

↗
↗
↗

External Photos

↗

ID Label/Location Info

↗

Internal Photos

↗

Test Report

↗

Test Setup Photos

↗

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

Users Manual

8 Health status Bluetooth Symbol SET SET FCC Statement This device complies with part 15 and part 18 of the FCC Rules. Operation is Subject To the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. Changes or modifications not explicitly approved by the party responsible for compliance could void the user's authority to operate this equipment. Note: this equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 and part 18 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and candidate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures: · Reorient or relocate the receiving antenna. · Increase the separation between the equipment and receiver. · Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. · Consult the dealer or an experienced radio/TV technician for help. This device complies with Part 18 of the FCC Rules. This equipment generates uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures: ● Increase the separation between the equipment and any other radio device. ● Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.

Cover Letter(s)

Shenzhen Gainstrong Technology Co., Ltd. Agent Authorization Company: Shenzhen Gainstrong Technology Co., Ltd. Address: 4/F,Building B,Hengmingzhu Industrial Park, Qian Jin Road 2,Baoan District,Shenzhen,Guangdong, China. Product Name: Infrared Forehead Thermometer Trade Mark: N/A Model Number(s): TG8818H, BT919, TG8818H-BT, VC888, VC919, HG01 FCC ID: 2AWGS-BT919 We authorize MiCOM Labs Inc., 575 Boulder Court, Pleasanton, California 94566, USA, to act on our behalf on all matters concerning the certification of above named equipment. We declare that MiCOM Labs Inc. is allowed to forward all information related to the approval and certification of equipment to the regulatory agencies as required and to discuss any issues concerning the approval application. Any and all acts carried out by MiCOM Labs on our behalf shall have the same effect as acts of our own. Signature: Date: 2002-05-23 Name: Ri dong Xiao Title: CEO Company: Shenzhen Gainstrong Technology Co., Ltd.

Cover Letter(s)

Shenzhen Gainstrong Technology Co., Ltd. 4/F,Building B,Hengmingzhu Industrial Park, Qian Jin Road 2,Baoan District,Shenzhen,Guangdong, China. Tel: 0755-85271272 Fax: / Date: 2020-05-23 Dear Sir/Madam, We, Shenzhen Gainstrong Technology Co., Ltd. Hereby declares the following statement , PCB board, circuit, structure and internal of these model(s) are the same, Only model number is different for these model: Product name: Infrared Forehead Thermometer Model No.: TG8818H, BT919, TG8818H-BT, VC888, VC919, HG01 Sincerely, Client’s name / title : Ri dong Xiao / CEO Contact information / address : 4/F,Building B,Hengmingzhu Industrial Park, Qian Jin Road 2,Baoan District,Shenzhen,Guangdong, China. Tel: 0755-85271272 Fax: / E-Mail: [email protected]

Cover Letter(s)

Shenzhen Gainstrong Technology Co., Ltd. Office of Engineering Technology Federal Communications Commission 7435 Oakland Mills Road Columbia, MD 21046 USA Date: 2020-05-23 Subject; Request for Confidentiality FCC ID: 2AWGS-BT919 To Whom It May Concern, Pursuant to the provisions of the Commission’s rules Title 47 Sections §0.457 and §0.459, we are requesting the Commission to withhold the following attachment(s) as confidential documents from public disclosure indefinitely. These documents contain detailed system and equipment descriptions and are considered as proprietary information in operation of the equipment. The public disclosure of these documents might be harmful to our company and would give competitors an unfair advantage in the market. Schematic Diagram Block Diagram Operational Description In additional to above mentioned documents, in order to comply with the marketing regulations in Title 47 CFR §2.803 and the importation rules in Title 47 CFR §2.1204, while ensuring that business sensitive information remains confidential until the actual marketing of newly authorized devices, we request Short Term Confidentiality of the following attachment(s); External Photos Test Setup Photos Internal Photos User Manual For 45 days, pursuant to Public Notice DA 04-1705. OR For 180 days pursuant to KDB 726920 D01. It is our understanding that all measurement test reports, FCC ID label format and correspondence during the certification review process cannot be granted as confidential documents and this information will be available for public review once the grant of equipment authorization is issued. Sincerely, Signature: Name: Ri dong Xiao Title: CEO

External Photos

SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD. FCC ID:2AWGS-BT919 This report shall not be reproduced except in full, without the written approval of Shenzhen LCS Compliance Testing Laboratory Ltd. Page 1 of 3 External Photos of the EUT Fig.1 Fig.2 SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD. FCC ID:2AWGS-BT919 This report shall not be reproduced except in full, without the written approval of Shenzhen LCS Compliance Testing Laboratory Ltd. Page 2 of 3 Fig.3 Fig.4 SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD. FCC ID:2AWGS-BT919 This report shall not be reproduced except in full, without the written approval of Shenzhen LCS Compliance Testing Laboratory Ltd. Page 3 of 3 Fig.5 Fig.6

ID Label/Location Info

SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD. FCC ID:2AWGS-BT919 This report shall not be reproduced except in full, without the written approval of Shenzhen LCS Compliance Testing Laboratory Ltd. Page 1 of 1 Label and Location Size: L2.5cm*W4.0cm Label Location Infrared Forehead Thermometer Model No.: :TG8818H FCC ID: 2AWGS-BT919 Input: DC 3V(Battery 2*AAA).

Internal Photos

SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD. FCC ID: 2AWGS-BT919 This report shall not be reproduced except in full, without the written approval of Shenzhen LCS Compliance Testing Laboratory Ltd. Page 1 of 4 Internal Photos of the EUT Fig.1 Fig.2 SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD. FCC ID: 2AWGS-BT919 This report shall not be reproduced except in full, without the written approval of Shenzhen LCS Compliance Testing Laboratory Ltd. Page 2 of 4 Fig.3 Fig.4 BT Antenna SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD. FCC ID: 2AWGS-BT919 This report shall not be reproduced except in full, without the written approval of Shenzhen LCS Compliance Testing Laboratory Ltd. Page 3 of 4 Fig.5 Fig.5 SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD. FCC ID: 2AWGS-BT919 This report shall not be reproduced except in full, without the written approval of Shenzhen LCS Compliance Testing Laboratory Ltd. Page 4 of 4 Fig.6

Test Report

SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD. FCC ID: 2AWGS-BT919 Report No.: LCS200506085AEB This report shall not be reproduced except in full, without the written approval of Shenzhen LCS Compliance Testing Laboratory Ltd. Page 1 of 14 TEST REPORT FOR FCC Shenzhen Gainstrong Technology Co., Ltd. Infrared Forehead Thermometer Test Model: TG8818H Additional Model No.: Please Refer To Page 7 Prepared for : Shenzhen Gainstrong Technology Co., Ltd. Address : 4/F,Building B,Hengmingzhu Industrial Park, Qian Jin Road 2,Baoan District,Shenzhen,Guangdong, China. Prepared by : Shenzhen LCS Compliance Testing Laboratory Ltd. Address : Room 101, 201, Building A and Room 301, Building C, Juji Industrial Park, Yabianxueziwei, Shajing Street, Bao’an District, Shenzhen, Guangdong, China Tel : (+86)755-82591330 Fax : (+86)755-82591332 Web : www.LCS-cert.com Mail : [email protected] Date of receipt of test sample : May 08, 2020 Number of tested samples : 1 Serial number : Prototype Date of Test : May 08, 2020 ~ May 13, 2020 Date of Report : May 15, 2020 SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD. FCC ID: 2AWGS-BT919 Report No.: LCS200506085AEB This report shall not be reproduced except in full, without the written approval of Shenzhen LCS Compliance Testing Laboratory Ltd. Page 2 of 14 TEST REPORT FOR FCC 47 CFR PART 18 Industrial, Scientific, and Medical Equipment Report Reference No. .......... : LCS200506085AEB Date Of Issue .......................... : May 15, 2020 Testing Laboratory Name ..... : Shenzhen LCS Compliance Testing Laboratory Ltd. Address ................................... : Room 101, 201, Building A and Room 301, Building C, Juji Industrial Park, Yabianxueziwei, Shajing Street, Bao’an District, Shenzhen, Guangdong, China Testing Location/ Procedure ... : Full application of Harmonised standards ■ Partial application of Harmonised standards □ Other standard testing method □ Applicant’s Name .................. : Shenzhen Gainstrong Technology Co., Ltd. Address ................................... : 4/F,Building B,Hengmingzhu Industrial Park, Qian Jin Road 2,Baoan District,Shenzhen,Guangdong,China. Test Specification Standard .................................. : 47 CFR PART 18, ANSI C63.4-2014, FCC/OST MP–5 Test Report Form No. ............. : LCSEMC-1.0 TRF Originator......................... : Shenzhen LCS Compliance Testing Laboratory Ltd. Master TRF ............................. : Dated 2011-03 SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD. All rights reserved. This publication may be reproduced in whole or in part for non-commercial purposes as long as the SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD. is acknowledged as copyright owner and source of the material. SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD. takes no responsibility for and will not assume liability for damages resulting from the reader's interpretation of the reproduced material due to its placement and context. Test Item Description. ........... : Infrared Forehead Thermometer Trade Mark .............................. : N/A Test Model .............................. : TG8818H Ratings .................................... : Input: DC 3V(Battery 2*AAA) Result ................................... : Positive Compiled by: Supervised by: Approved by: Vera Deng/ File administrators Jin Wang/ Technique principal Gavin Liang/ Manager SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD. FCC ID: 2AWGS-BT919 Report No.: LCS200506085AEB This report shall not be reproduced except in full, without the written approval of Shenzhen LCS Compliance Testing Laboratory Ltd. Page 3 of 14 FCC -- TEST REPORT Test Result according to the standards on page 6: Positive The test report merely corresponds to the test sample. It is not permitted to copy extracts of these test result without the written permission of the test laboratory. Test Report No. : LCS200506085AEB May 15, 2020 Date of issue Test Model......................... : TG8818H EUT.................................... : Infrared Forehead Thermometer Applicant........................... : Shenzhen Gainstrong Technology Co., Ltd. Address.............................. : 4/F,Building B,Hengmingzhu Industrial Park, Qian Jin Road 2,Baoan District,Shenzhen,Guangdong,China. Telephone.......................... : / Fax..................................... : / Manufacturer..................... : Shenzhen Gainstrong Technology Co., Ltd. Address.............................. : 4/F,Building B,Hengmingzhu Industrial Park, Qian Jin Road 2,Baoan District,Shenzhen,Guangdong,China. Telephone.......................... : / Fax..................................... : / Factory.............................. : Shenzhen Gainstrong Technology Co., Ltd. Address.............................. : 4/F,Building B,Hengmingzhu Industrial Park, Qian Jin Road 2,Baoan District,Shenzhen,Guangdong,China. Telephone.......................... : / Fax..................................... : / SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD. FCC ID: 2AWGS-BT919 Report No.: LCS200506085AEB This report shall not be reproduced except in full, without the written approval of Shenzhen LCS Compliance Testing Laboratory Ltd. Page 4 of 14 Revision History Revision Issue Date Revisions Revised By 000 May 15, 2020 Initial Issue Jesse Liu SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD. FCC ID: 2AWGS-BT919 Report No.: LCS200506085AEB This report shall not be reproduced except in full, without the written approval of Shenzhen LCS Compliance Testing Laboratory Ltd. Page 5 of 14 TABLE OF CONTENTS Test Report Description Page 1. SUMMARY OF STANDARDS AND RESULTS .................................................................... 6 1.1. Description of Standards and Results .......................................................................................... 6 2. GENERAL INFORMATION ...................................................................................................... 7 2.1. Description of Device (EUT) ...............…

Text truncated - open the document above for the full version.

Test Setup Photos

SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD. FCC ID: 2AWGS-BT919 _______________________________________________________________________________________________ This report shall not be reproduced except in full, without the written approval of Shenzhen LCS Compliance Testing Laboratory Ltd. Page 1 of 1 Appendix A Photographs of Test Setup Radiated Emission below 30MHz-AC adapter charge mode Radiated Emission Below 1 GHz

Contact Information

Applicant

Ri dong Xiao(CEO)
[email protected]86-0755-8527127Fax: 86-0755-8527127

Technical Contact

Shenzhen Gainstrong Technology Co., Ltd.
[email protected]

China

Test Firm

Shenzhen LCS Compliance Testing Laboratory Ltd.Gavin Liang
[email protected]0755-82591330Fax: 0755-82591132

Technical Specifications

#Rule PartsFrequency RangePower Output
1182.40 GHz - 2.48 GHz-
Confidentiality
Long Term