Document Title : Phone Sterilizer GUANG DONG LDNIO ELECTRONICCO., LTD Model: UVS11 Date: 2020/06/12 Company Confidential : ■YES□NO Revision: V1.0 Page 1 of 11 GUANGDONG LDNIO ELECTRONIC TECHNOLOGY CO., LTD SPECIFICATION Customer GoCharge Customer P/NTBD Product Phone Sterilizer with Wireless Charging LDNIO ModelUVS11, UVS10 Pro duct description Phone Sterilizer / Input 5V2A/ Output USB-A 5V2A /Wireless Charging TX 5W RevisionREV1.5 Issue Date2020/06/12 PLEASE RETURN TO US ONE COPY OF 〝SPECIFICATION FOR APPROVAL〞WITH YOUR SIGNATURE SIGNATURE LDNIO / R&DLDNIO / EE LDNIO / Approval Customer Approval Address: H/O: 4c888,4/F,Nanfang Building internatioal Electronic digtal city, Xidi Second Road, GZ. Factory:1F,Block One,No.6 Factory, ShenliEast Rd,Area B of PingZhou industrial Park, Guicheng Street, Nanhai District Foshan City, Guangdong Province, China 地址:佛山市南海区桂城街道平洲工业区 B 区胜利东路 Web: www.LDNIO.com Document Title : Phone Sterilizer GUANG DONG LDNIO ELECTRONICCO., LTD Model: UVS11 Date: 2020/06/12 Company Confidential : ■YES□NO Revision: V1.0 Page 2 of 11 REVISIONREASON FOR CHANGEDATE V1.0Initial2020/03/16 V1.1 Tx 10w Charge Tx 5W, Remove the aromatherapy 2020/03/18 V1.2 Revision ID Size2020 /04/13 V1.3 Add 3-9 FCC Statement and lable 2020/05/29 V1.4 Add 3-11 Mechanical drawingand 3-12 Function description2020/06/02 V1.5 Revision Product Name2020/06/12 R&DPMEngQASales LouisStevenYangChenDanny Sample Picture Document Title : Phone Sterilizer GUANG DONG LDNIO ELECTRONICCO., LTD Model: UVS11 Date: 2020/06/12 Company Confidential : ■YES□NO Revision: V1.0 Page 3 of 11 Contents 1. Scope ---------------------------------------------------------------- 4 2. Product Feature-------------------------------------------------------- 4 3. Product -------------------------------------------------------------- 5 3-1 DC Input characteristics ------------------------------------------------ 5 3-2 Wireless Charging Characteristics-----------------------------------------5 3-3 USB DC output characteristics------------------------------------------- 5 3-4 UVcold ultra-violet lamp Spectification ------------------------------------ 6 3-5 Other characteristics --------------------------------------------------- 6 3-6 Environmental --------------------------------------------------------- 7 3-7 Mechanical Characteristics ---------------------------------------------- 7 3-8 Agency Approvals ------------------------------------------------------- 7 3-9 FCC Statement ---------------------------------------------------------- 8 3-10 Lable------- ---------------------------------------------------------- 9 3-11 Mechanical drawing--------------------------------------------------- 10 3-12 Function description diagram------------------------------------------- 11 Document Title : Phone Sterilizer GUANG DONG LDNIO ELECTRONICCO., LTD Model: UVS11 Date: 2020/06/12 Company Confidential : ■YES□NO Revision: V1.0 Page 4 of 11 1.Scope This document contains general Customer requirements, qualification, requirement and those specific electrical and mechanical requirements for this part. 1. The units with a Sanitizing Box with Wireless Charger, 2. With big ultraviolet lamp on two sides, 360 °C Sterilization. 3. With an input Micro-USB and provide DC power by USB Type A ,Sterilization while charging the mobile phone. 4. With big capacity, suitable for most 7 inch mobile Phone/Pad/Watch and jewelry. 5. With smart dimension and 5V low voltage.Portable and safe. 6. With wireless charging function for Tx5w, workable for iPhone and other Android mobile Phones. 2.Product Features: Document Title : Phone Sterilizer GUANG DONG LDNIO ELECTRONICCO., LTD Model: UVS11 Date: 2020/06/12 Company Confidential : ■YES□NO Revision: V1.0 Page 5 of 11 3.Product ItemSpecification 3-1 DC Input characteristics 3-1-1 Input requirementVoltage: 5V/2A, max 3-1-2 Input over voltage protection function N/A 3-1-3 Input connectorMicroUSB 3-2 Wireless ChargingCharacteristics 3-2-1 Standards tobe followed:WPC Qi v1.2.4 3-2-2 Coil type1-coil (A11) 3-2-3 Peak efficiency:71.5% @ CP 5W Tx output 3-2-4 Stand-by power:< 1000 mW (Sanitizing Box included) 3-2-5 Wireless Out put5W,Max(5V/1A) 3-3 USB DC output characteristics 3-3-1 Output requirementVoltage: 5V level (4.95~5.5V) / 2A 3-3-2 Output Power10W continuous 3-3-3 Output Ripple100mV for all voltage 3-3-4 Output over current protection points <3.5A The should enter hiccu pmode(auto-recover). 3-3-5 Output over current protection detection time need longer than 5mS 3-3-6 Output short circuit protection function Yes, no damaged. The battery bank should enter hiccup mode (auto-recover). 3-3-7 Output Reverse CurrentThe stable reverse current should be under 5mA 3-3-8 Support Charging and Sanitizing at the same timeYES 3-3-9 Output connectorUSB type A Document Title : Phone Sterilizer GUANG DONG LDNIO ELECTRONICCO., LTD Model: UVS11 Date: 2020/06/12 Company Confidential : ■YES□NO Revision: V1.0 Page 6 of 11 3-4 UVcold ultra-violet lampSpectification 3-4-1 Power (Sterilize):2x1.5W 3-4-2 UV lamp size φ 4*8mm/120mm/280Vac/5mA/1.5W/(>1500 μ W/ CM 2 )/ 10000H 3-5 Other characteristics 3-5-1 Sterilization button key Press the “Sterilization” button to switch between 2 modes of sanitization. 1. 15mins Fast mode. Press the “Sterilization” button once, the button will ON in red color, indicating fast mode is ON. 2. 30mins Standard mode. Press the “Sterilization” button twice, the button will ON in blue color, indicating standard mode is ON. 3. The indicator light will ON in green color when Sanitizing prcoess is completed. 3-5-2 Key The UV light will be OFF, indicating sanitizating process is paused when the lid is open. The process will be resumed when the lid is closed. Document Title : Phone Sterilizer GUANG DONG LDNIO ELECTRONICCO., LTD Model: UVS11 Date: 2020/06/12 Company Confidential : ■YES□NO Revision: V1.0 Page 7 of 11 3-6Environmental 3-6-1 Operation temperature 0 °C to 40 °C 3-6-2 Operation humidity10%~95% RH 3-6-3 Stora get…
Text truncated - open the document above for the full version.
Rev 11/20/07 GuangDong LDNIO Electronic Technology Co., Ltd. Federal Communications Commission Authorization and Evaluation Division Confidentiality Request regarding application for certification of FCC ID: 2AWJ3-UVS11 Pursuant to Sections 0.457 and 0.459 of the Commission’s Rules, we hereby request confidential treatment of information accompanying this application as outlined below: Exhibit TypeFile Name Block Diagram Schematics Operational Description Block SCH Operational Description The above materials contain trade secrets and proprietary information not customarily released to the public. The public disclosure of these materials may be harmful to the applicant and provide unjustified benefits to its competitors. The applicant understands that pursuant to Section 0.457 of the Rules, disclosure of this application and all accompanying documentation will not be made before the date of the Grant for this application. Pursuant to DA04-1705 June 15, 2004 of the Commission’s public notice, We also requesting the commission to grant short-term confidentiality request on the following attachments until180 days after the Grant Date of Equipment Authorizations. Exhibit TypeFile Name External Photos Internal Photos Test Setup Photos Manual External Photos Internal Photos Test Setup Photos User manual Sincerely, Danny Liang
GuangDong LDNIO Electronic Technology Co., Ltd. Declaration on model difference We the undersigned hereby confirm that these models are identical, and all models have the same RFmodule and antenna, PCB layout , schematics and component.Only different on model number. Production nameTrademarkFCC IDModel no. PHONE STERILIZER/2AWJ3‐UVS11UVS11, UVS10 Confirmed by: Danny Liang 2020-06-10
M:\Master Documents\TEMPLATES\POA_Letter.doc GuangDong LDNIO Electronic Technology Co., Ltd. Federal Communications Commission Authorization and Evaluation Division 1435 Oakland Mills Road Columbia, MD 21046 Date: 2020/06/10 SUBJECT: FCC Application for (FCC ID:2AWJ3-UVS11) To Whom It May Concern: We, the undersigned, hereby authorize EMTEK (SHENZHEN) CO., LTD. at Lisa Wang on our behalf, to apply to the Federal Communications Commission on our equipment. Any and all acts carried out by EMTEK (SHENZHEN) CO., LTD. on our behalf shall have the same effect as acts of our own. This is to advise that we are in full compliance with the Anti- Drug Abuse Act. We, the applicant, are not subject to a denial of federal benefits pursuant to Section 5301 of the Anti-Drug Act of 1988, 21 USC853a, and no party to the application is subject to a denial of federal benefits pursuant to that section. Regards, Danny Liang 2020-06-10
GuangDongLDNIOElectronicTechnologyCo.,Ltd. FederalCommunicationsCommission AuthorizationandEvaluationDivision 1435OaklandMillsRoad Columbia,MD21046 Date:2020/06/16 SUBJECT:FCCApplicationfor(FCCID:2AWJ3-UVS11) Weassurethat: (1)Powertransferfrequencyislessthan1MHz. (2) Outputpowerfromeachprimarycoilislessthan15watts. (3) Thetransfersystemincludesonlysingleprimary. (4) Clientdeviceisplaceddirectlyincontactwiththetransmitter. (5) Mobileexposureconditionsonly. (6) TheaggregateH-fieldstrengthsat15cmsurroundingthedeviceand20cmabove thetopsurfacefromallsimultaneoustransmittingcoilsaredemonstratedtobeless than50%oftheMPElimit. Regards, DannyLiang 2020-06-16
FCCID:2AWJ3-UVS11
FCCID:2AWJ3-UVS11 ANT
ReportNo.ES200518043W1Page 1 of 13 Ver.1.0 TESTREPORT ProductName : PHONESTERILIZER ModelNumber : UVS11,UVS10 FCCID : 2AWJ3-UVS11 Preparedfor:GuangDongLDNIOElectronicTechnologyCo.,Ltd. Address:1Floor,1Building,No.6ShengliEastRoad,ZoneB,PingZhou industrialPark,Guicheng,NanhaiDistrict,Foshan,Guangdong Preparedby: EMTEK(SHENZHEN)CO.,LTD. Address: Building69,MajialongIndustryZone,NanshanDistrict, Shenzhen,Guangdong,China Tel:(0755)26954280 Fax:(0755)26954282 ReportNumber:ES200518043W1 Date(s)ofTests:May25,2020toJune16,2020 Dateofissue:June16,2020 ReportNo.ES200518043W1Page 2 of 13 Ver.1.0 TABLEOFCONTENT TestReportDescriptionPage 1.SUMMARYOFTESTRESULT.........................................................................................................4 2.GENERALINFORMATION................................................................................................................5 2.1.DESCRIPTIONOFDEVICE(EUT).....................................................................................................................................5 2.2.DESCRIPTIONOFTESTFACILITY.....................................................................................................................................6 2.3.MEASUREMENTUNCERTAINTY.........................................................................................................................................6 3.MEASURINGDEVICEANDTESTEQUIPMENT..........................................................................7 3.1.FORMPEMEASUREMENT..............................................................................................................................................7 4.RFEXPOSURE....................................................................................................................................7 4.1.MEASURINGSTANDARD...................................................................................................................................................8 4.2.REQUIMENTS....................................................................................................................................................................8 4.3.TESTCONFIGURATION......................................................................................................................................................9 4.4.LIMITS.............................................................................................................................................................................10 4.5.MEASURINGRESULTS....................................................................................................................................................11 5.PHOTOGRAPHSOFTESTSETUP...............................................................................................13 ReportNo.ES200518043W1Page 3 of 13 Ver.1.0 TESTREPORTDESCRIPTION Applicant:GuangDongLDNIOElectronicTechnologyCo.,Ltd. Address: 1Floor,1Building,No.6ShengliEastRoad,ZoneB,PingZhouindustrialPark, Guicheng,NanhaiDistrict,Foshan,Guangdong Manufacturer:GuangDongLDNIOElectronicTechnologyCo.,Ltd. Address: 1Floor,1Building,No.6ShengliEastRoad,ZoneB,PingZhouindustrialPark, Guicheng,NanhaiDistrict,Foshan,Guangdong EUT:PHONESTERILIZER ModelName:UVS11,UVS10 Trademark:N/A MeasurementProcedureUsed: FCCPart1(1.1310)andPart2(2.1091) 680106D01RFExposureWirelessChargingAppv03 ThedevicedescribedaboveistestedbySHENZHENEMTEKCO.,LTD.todeterminethemaximum emissionlevelsemanatingfromthedeviceandtheseverelevelsofthedevicecanendureandits performancecriterion.ThemeasurementresultsarecontainedinthistestreportandSHENZHEN EMTEKCO.,LTD.isassumedfullofresponsibilityfortheaccuracyandcompletenessofthese measurements.Also,thisreportshowsthattheEUT(EquipmentUnderTest)istechnicallycompliant withtheFCCrequirements. DateofTest: May25,2020toJune16,2020 Preparedby: BillZhong/Editor Reviewer: GalenXiao/Supervisor Approved&AuthorizedSigner: LisaWang/Manager ReportNo.ES200518043W1Page 4 of 13 Ver.1.0 1.SUMMARYOFTESTRESULT EMISSION DescriptionofTestItemStandard&LimitsResults MPE FCCPart1(1.1310)andPart2(2.1091) 680106D01RFExposureWireless ChargingAppv03 Pass Note:N/AisanabbreviationforNotApplicable. ReportNo.ES200518043W1Page 5 of 13 Ver.1.0 2.GENERALINFORMATION 2.1.DescriptionofDevice(EUT) EUT: PHONESTERILIZER ModelNumber: UVS11,UVS10 ( (Note:Thesemodelsarethesameexpectthemodelname,Hereselect UVS11forfulloftest.) PowerRating:AC120V/60Hzforadapter Operation FrequencyforWPT :110-205kHz AntennaType: : Inductioncoil Modulation:Induction DateofReceived:May25,2020 DateofTest:May25,2020toJune16,2020 ReportNo.ES200518043W1Page 6 of 13 Ver.1.0 2.2.DescriptionofTestFacility SiteDescription EMCLab.:AccreditedbyCNAS,2018.11.30 Thecertificateisvaliduntil2022.10.28 TheLaboratoryhasbeenassessedandprovedtobeincompliancewith CNAS-CL01:2006(identicaltoISO/IEC17025:2017) TheCertificateRegistrationNumberisL2291 AccreditedbyTUVRheinlandShenzhen2018.03.30 TheLaboratoryhasbeenassessedaccordingtotherequirementsISO/IEC 17025 AccreditedbyFCC,August09,2018 DesignationNumber:CN1204 TestFirmRegistrationNumber:882943 AccreditedbyA2LA,August08,2018 TheCertificateRegistrationNumberis4321.01 AccreditedbyIndustryCanada,November09,2018 TheConformityAssessmentBodyIdentifierisCN0008 NameofFirm:EMTEK(SHENZHEN)CO.,LTD. SiteLocation: Bldg69,MajialongIndustryZone, NanshanDistrict,Shenzhen,Guangdong,China 2.3.MeasurementUncertainty RadiatedEmissionUncertainty:3.3dB(30M~1GHzPolarize:H) 3.2dB(30M~1GHzPolarize:V) 3.7dB(1~18GHzPolarize:H) 3.6dB(1~18GHzPolarize:V) ReportNo.ES200518043W1Page 7 of 13 Ver.1.0 3.MEASURINGDEVICEANDTESTEQUIPMENT 3.1.ForMPEMeasurement UsedEquipmentManufacturerModelNo.SerialNo.LastCal.Cal.Interval E-Field Probe(100kHz-3GHz) NardaEF03912304/03May16,20201Year BroadbandFieldMeterNardaNBM-550232421May16,20201Year ExposureLevel Tester(1Hz-400KHz) NardaELT-400C-0012May16,20201Year ReportNo.ES200518043W1Page 8 of 13 Ver.1.0 4.RFEXPOSURE 4.1.MeasuringStandard FCCPart1(1.1310)andPart2(2.1091) 4.2.Req…
Text truncated - open the document above for the full version.
ReportNo.ES200518043WPage 1 of 23 Ver.1.0 TESTREPORT ProductName : PHONESTERILIZER ModelNumber : UVS11,UVS10 FCCID : 2AWJ3-UVS11 Preparedfor:GuangDongLDNIOElectronicTechnologyCo.,Ltd. Address:1Floor,1Building,No.6ShengliEastRoad,ZoneB, PingZhouindustrialPark,Guicheng,NanhaiDistrict, Foshan,Guangdong Preparedby:EMTEK(SHENZHEN)CO.,LTD. Address:Building69,MajialongIndustryZone,NanshanDistrict, Shenzhen,Guangdong,China Tel:(0755)26954280 Fax:(0755)26954282 ReportNumber:ES200518043W Date(s)ofTests:May20,2020toJune09,2020 Dateofissue:June09,2020 ReportNo.ES200518043WPage 2 of 23 Ver.1.0 VERIFICATIONOFCOMPLIANCE Applicant:GuangDongLDNIOElectronicTechnologyCo.,Ltd. 1Floor,1Building,No.6ShengliEastRoad,ZoneB,PingZhou industrialPark,Guicheng,NanhaiDistrict,Foshan,Guangdong Manufacturer:GuangDongLDNIOElectronicTechnologyCo.,Ltd. 1Floor,1Building,No.6ShengliEastRoad,ZoneB,PingZhou industrialPark,Guicheng,NanhaiDistrict,Foshan,Guangdong Factory:GuangDongLDNIOElectronicTechnologyCo.,Ltd. 1Floor,1Building,No.6ShengliEastRoad,ZoneB,PingZhou industrialPark,Guicheng,NanhaiDistrict,Foshan,Guangdong ProductDescription:PHONESTERILIZER TradeMark:N/A ModelNumber: UVS11,UVS10 (Note:Thesemodelsarethesameexpectthemodelname,Here selectUVS11forfulloftest.) Weherebycertifythat: TheaboveequipmentwastestedbyEMTEK(SHENZHEN)CO.,LTD.The testdata,dataevaluation,testprocedures,andequipmentconfigurations showninthisreportweremadeinaccordancewiththeproceduresgivenin ANSIC63.10-2013andtheenergyemittedbythesampleEUTtestedas describedinthisreportisincompliancewithconductedandradiatedemission limitsofFCCRulesPart15C. DateofTest: May20,2020toJune09,2020 Preparedby: BillZhong/Editor Reviewer: GalenXiao/Supervisor Approved&AuthorizedSigner: LisaWang/Manager ReportNo.ES200518043WPage 3 of 23 Ver.1.0 ModifiedInformation VersionSummaryRevisionDateReportNo. Ver.1.0OriginalReport/ES200518043W ReportNo.ES200518043WPage 4 of 23 Ver.1.0 TableofContents 1GENERALINFORMATION..............................................................................................................................5 1.1PRODUCTDESCRIPTION...............................................................................................................................5 1.2RELATEDSUBMITTAL(S)/GRANT(S)...........................................................................................................6 1.3TESTMETHODOLOGY...................................................................................................................................6 1.4SPECIALACCESSORIES................................................................................................................................6 1.5EQUIPMENTMODIFICATIONS........................................................................................................................6 1.6TESTFACILITY...............................................................................................................................................6 2SYSTEMTESTCONFIGURATION.................................................................................................................7 2.1EUTCONFIGURATION..................................................................................................................................7 2.2EUTEXERCISE.............................................................................................................................................7 2.3TESTPROCEDURE........................................................................................................................................7 2.4CONFIGURATIONOFTESTEDSYSTEM.........................................................................................................8 3SUMMARYOFTESTRESULTS.....................................................................................................................8 4DESCRIPTIONOFTESTMODES..................................................................................................................9 5CONDUCTEDEMISSIONSTEST.................................................................................................................10 5.1MEASUREMENTPROCEDURE.....................................................................................................................10 5.2TESTSET-UP(BLOCKDIAGRAMOFCONFIGURATION)...........................................................................10 5.3MEASUREMENTEQUIPMENTUSED............................................................................................................10 5.4CONDUCTEDEMISSIONLIMIT.....................................................................................................................10 5.5MEASUREMENTRESULT.............................................................................................................................11 6RADIATEDEMISSIONTEST.........................................................................................................................14 6.1MEASUREMENTPROCEDURE.....................................................................................................................14 6.2TESTSET-UP(BLOCKDIAGRAMOFCONFIGURATION)...........................................................................14 6.3MEASUREMENTEQUIPMENTUSED............................................................................................................15 6.4RADIATEDEMISSIONLIMIT.........................................................................................................................15 6.5MEASUREMENTRESULT.............................................................................................................................17 720DBBANDWIDTH.........................................................................................................................................20 7.120DBBANDWIDTHLIMIT.............................................................................................................................20 7.2TESTINSTRUMENTS.......…
Text truncated - open the document above for the full version.
FCCID:2AWJ3-UVS11 ConductedMeasurementPhoto RadiatedMeasurementPhotos
| # | Rule Parts | Frequency Range | Power Output |
|---|---|---|---|
| 1 | 15C | 0.11 MHz - 0.205 MHz | - |