
Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.
Kit Contains: β’ 1 Thermo-Scanner β’ 1 Power Supply β’ 2 Allen Wrenches 1. Open the box and remove the Thermo-Scanner. 2. Take the power supply out of the box. Connect the power cable to the power brick. 3. Take the larger of the two hex key wrenches out. 4. Use the hex key wrench to unscrew the two screws shown in the photo below (there will be one screw on each side). Larger wrench loosens the arm to position it to be placed in the electrical box. The smaller wrench tightens the mounting arm. 5. Rotate the mounting bracket as shown in the photo below. Screw the two hex screws back in. 6. The device should now look like the photo below once the mounting bracket has been rotated. 7. Install the Thermo-Scanner on to the desired mount (i.e., wall, free-standing, table-top, junction box). The diameter of the mounting hole is 1.299 inches (33mm). a. If using a junction box, follow the steps below. It will fit in a 1.25 inch electrical knock out. b. A 4"H x 4"W x 4"D enclosure with knockouts will be needed. c. Punch out a hole on the top of the box. Model: Face ID X8 V2 FCC ID: 2AWPHFEX8V2 Instructions: d. Unscrew the small black ring piece on the thread of the Thermo-Scanner's mounting bracket. e. Run the cables through the hole in the junction box. f. Screw the black ring piece back on to the thread of the mounting bracket to secure the scanner to the box. 8. Ensure the bottom of the Thermo-Scanner is 5 feet from the floor. 9. Install the Thermo-Scanner mounting bracket perpendicular (90 degrees) to the floor (not on any other angle). 10. Adjust the thermal sensor (top piece) so that the tablet portion of the device is at a slight angle, and the thermal sensor is perpendicular with the floor (see photo below for an example). 11. Plug the power cable into the Thermo-Scanner. Connect the other end to a power outlet. 12. If using a wired connection, plug in an Ethernet cable from your existing internet connection to the RJ45 port on the device. 13. Your Thermo-Scanner is now set up and ready to use. If you have any installation issues, please call the number (860-600-0336) on the back of the unit and have your asset tag ready. Support available M-F, 8am β 6pm EST (no holidays). This device is not intended for use in the diagnosis of disease or other conditions or in the cure, mitigation, treatment, or prevention of disease. This device is not intended for a medical purpose, including 1. use by a health care professional; 2. use in a health care facility or environment; and 3. use that meets the definition of a device, (e.g., body temperature measurement for diagnostic purposes, including such use in non-medical environments). Please use the product according to the following safety instructions and warnings: The recommended installation height (H) is from 1.30m to 1.45m which can cover human height of 1.4m ~1.9m in the detection area. It can be adjusted according to the actual scene. The best temperature measuring distance ranges from 0.3m to 0.4m. * Do not place the camera in extremely hot, cold, dusty or damp location. * Do not expose it to high electromagnetic radiation. * If the product does not work properly, please contact 860-600-0336. * Never attempt to disassemble the camera yourself. (Weshall not be responsible for any problems caused by unauthorized repair or maintenance.) * Do not drop the camera or subject it to physical shock. * Keep away from liquid while in use. * Do not touch the screen with sharp objects. * If cleaning is necessary, please use clean cloth to wipe it gently, avoiding water or alcohol. * Make sure faces can be captured clearly. * Avoid direct sunlight and backlight. The device should be at least 2 meters away from the light, and at least 3 meters away from the window or door. FCC compliance state ment This device complies with Part 15 of the FCC Rules. Operation i s subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, in cluding interference that ma y cause undesired operation. changes or modificat ions not expressly approved by the party r esponsible for compliance could void the userβs authority to operate the equipment. This equipment has b een tested and found to comply with the limits for a Class B digital device, pursuan t to Part 15 of the FCC Rules. T hese limits are designed to provide reaso nable protection against harmful interfere nce in a residential installatio n. This equipment generates, uses and can radiate radio frequency energy and, if no t installed and used in accordance with the instructions, may cau se harmful interference to radio commun ications. However, there is no guarantee that interference will not occu r in a particular installation. If this equipment doe s cause harmful interference to radio or t elevision reception, which can be determ ined by turning the equipmen t off and on, the user is encouraged to tr y to correct the interference by one or mo re of the following measures: -- Reorient or relocat e the receiving antenna. -- Increase the separa tion between the equipment and receive r. -- Connect the equipm ent into an outlet on a circuit different fr om that to which the receiver is connecte d. -- Consult the dealer or an experienced radio/TV technician for help. FCC Radiation Exposu re statement This equipment complies with FCC radiation exposur e limits set forth for an uncontrolled environment. This equipment should be installed a nd operated with m inimum distance 20cm between the radiator and your body. This transmitter must not be co -located or operating in conjunction with any other antenna or transmitter.
SGS-CSTC Standards Technical Services Co., Ltd. Shenzhen Branch Page: 1 of 6 External Photos for SZEM2006005014CR FCC ID: 2AWPHFEX8V2 SGS-CSTC Standards Technical Services Co., Ltd. Shenzhen Branch Page: 2 of 6 1 EUT Constructional Details SGS-CSTC Standards Technical Services Co., Ltd. Shenzhen Branch Page: 3 of 6 SGS-CSTC Standards Technical Services Co., Ltd. Shenzhen Branch Page: 4 of 6 SGS-CSTC Standards Technical Services Co., Ltd. Shenzhen Branch Page: 5 of 6 SGS-CSTC Standards Technical Services Co., Ltd. Shenzhen Branch Page: 6 of 6
* Reality Interactive * Model: X8V2 * FCC ID: 2AWPHFEX8V2 * Input: 12V 3A * Year of contrustion: 2020 * Made in P.R.C This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. label size: 50*30mmlabel size: 50*30mm
SGS-CSTC Standards Technical Services Co., Ltd. Shenzhen Branch Page: 1 of 9 Internal Photos for SZEM2006005014CR FCC ID: 2AWPHFEX8V2 SGS-CSTC Standards Technical Services Co., Ltd. Shenzhen Branch Page: 2 of 9 1 EUT Constructional Details SGS-CSTC Standards Technical Services Co., Ltd. Shenzhen Branch Page: 3 of 9 SGS-CSTC Standards Technical Services Co., Ltd. Shenzhen Branch Page: 4 of 9 SGS-CSTC Standards Technical Services Co., Ltd. Shenzhen Branch Page: 5 of 9 SGS-CSTC Standards Technical Services Co., Ltd. Shenzhen Branch Page: 6 of 9 SGS-CSTC Standards Technical Services Co., Ltd. Shenzhen Branch Page: 7 of 9 SGS-CSTC Standards Technical Services Co., Ltd. Shenzhen Branch Page: 8 of 9 SGS-CSTC Standards Technical Services Co., Ltd. Shenzhen Branch Page: 9 of 9
SGS-CSTC Standards Technical Services Co., Ltd. Shenzhen Branch Report No.: SZEM200600501403 Page: 1 of 7 Keny Xu EMC Laboratory Manager 1 Cover page RF Exposure Evaluation Report Application No.: SZEM2006005014CR Applicant: Mekotronics Co., Ltd Address of Applicant: Rm1103-1105, Hengrong Lifang Building, Baomin 2nd Rd, Baoan District, Shenzhen, China Manufacturer: Mekotronics Co., Ltd Address of Manufacturer: Rm1103-1105, Hengrong Lifang Building, Baomin 2nd Rd, Baoan District, Shenzhen, China Factory: Mekotronics Co., Ltd Address of Factory: Rm1103-1105, Hengrong Lifang Building, Baomin 2nd Rd, Baoan District, Shenzhen, China Equipment Under Test (EUT): Product Name: 8 inch tablet Model No.: X8 Trade mark: Reality Interactive FCC ID: 2AWPHFEX8V2 Standards: 47 CFR Part 1.1307 (2016) 47 CFR Part 1.1310 (2016) 47 CFR PART 2, Subpart I, Section 2.1091 Date of Receipt: 2020-06-12 Date of Test: 2020-06-25 to 2020-07-08 Date of Issue: 2020-07-17 Test Result : PASS* * In the configuration tested, the EUT complied with the standards specified above. SGS-CSTC Standards Technical Services Co., Ltd. Shenzhen Branch Report No.: SZEM200600501403 Page: 2 of 7 2 Version Revision Record Version Chapter Date Modifier Remark 01 2020-07-17 Original Authorized for issue by: Leo Li /Project Engineer Eric Fu /Reviewer SGS-CSTC Standards Technical Services Co., Ltd. Shenzhen Branch Report No.: SZEM200600501403 Page: 3 of 7 3 Contents Page 1 COVER PAGE ........................................................................................................................................ 1 2 VERSION ................................................................................................................................................ 2 3 CONTENTS ............................................................................................................................................ 3 4 GENERAL INFORMATION ..................................................................................................................... 4 4.1 GENERAL DESCRIPTION OF EUT ............................................................................................................. 4 4.2 TEST LOCATION .................................................................................................................................... 5 4.3 TEST FACILITY ...................................................................................................................................... 5 4.4 DEVIATION FROM STANDARDS ................................................................................................................. 5 4.5 ABNORMALITIES FROM STANDARD CONDITIONS ........................................................................................ 5 4.6 OTHER INFORMATION REQUESTED BY THE CUSTOMER .............................................................................. 5 5 RF EXPOSURE EVALUATION ............................................................................................................... 6 5.1 RF EXPOSURE COMPLIANCE REQUIREMENT ............................................................................................. 6 5.1.1 Limits .......................................................................................................................................... 6 5.1.2 Test Procedure ........................................................................................................................... 6 4.1.3 EUT RF EXPOSURE EVALUATION ........................................................................................................... 7 SGS-CSTC Standards Technical Services Co., Ltd. Shenzhen Branch Report No.: SZEM200600501403 Page: 4 of 7 4 General Information 4.1 General Description of EUT Power Supply: Adapter Model: HLT-180-1203000 Input: 100-240VAC, 50/60Hz 2A Max Output: DC12V 3A Cable: AC cable: 80cm unshielded DC cable: 80cm unshielded Operation Frequency: 802.11b/g/n(HT20): 2412MHz to 2462MHz Modulation Type: 802.11b: DSSS (CCK, DQPSK, DBPSK) 802.11g/n: OFDM (64QAM, 16QAM, QPSK, BPSK) Number of Channels: 802.11b/g/n(HT20):11 Channel Spacing: 5MHz Antenna Type: FPC Antenna Antenna Gain: 2dBi SGS-CSTC Standards Technical Services Co., Ltd. Shenzhen Branch Report No.: SZEM200600501403 Page: 5 of 7 4.2 Test Location All tests were performed at: SGS-CSTC Standards Technical Services Co., Ltd. Shenzhen Branch No. 1 Workshop, M-10, Middle section, Science & Technology Park, Shenzhen, Guangdong, China 518057 Telephone: +86 (0) 755 2601 2053 Fax: +86 (0) 755 2671 0594 No tests were sub-contracted. 4.3 Test Facility The test facility is recognized, certified, or accredited by the following organizations: β’ A2LA (Certificate No. 3816.01) SGS-CSTC Standards Technical Services Co., Ltd., Shenzhen EMC Laboratory is accredited by the American Association for Laboratory Accreditation(A2LA). Certificate No. 3816.01. β’ VCCI The 3m Fully-anechoic chamber for above 1GHz, 10m Semi-anechoic chamber for below 1GHz, Shielded Room for Mains Port Conducted Interference Measurement and Telecommunication Port Conducted Interference Measurement of SGS-CSTC Standards Technical Services Co., Ltd. have been registered in accordance with the Regulations for Voluntary Control Measures with Registration No.: G-20026, R-14188, C-12383 and T-11153 respectively. β’ FCC βDesignation Number: CN1178 SGS-CSTC Standards Technical Services Co., Ltd., Shenzhen EMC Laboratory has been recognized as an accredited testing laboratory. Designation Number: CN1178. Test Firm Registration Number: 406779. β’ Innovation, Science and Economic Development Canada SGS-CSTC Standards Technical Services Co., Ltd., Shenzhen EMC Laboratory has been recognized by ISED as an accredited testing laboratory. CAB identifier: CN0006. IC#: 4620C. 4.4 Deviation from Standards None. 4.5 Abnormalities from Standard Conditions None. 4.6 Other Information Requested by the Customer None. SGS-CSTC Standards Technical Services Co., Ltd. β¦
Text truncated - open the document above for the full version.
SGS-CSTC Standards Technical Services Co., Ltd. Shenzhen Branch Report No.: SZEM200600501402 Page: 1 of 106 Keny Xu EMC Laboratory Manager TEST REPORT Application No.: SZEM2006005014CR Applicant: Mekotronics Co., Ltd Address of Applicant: Rm1103-1105, Hengrong Lifang Building, Baomin 2 nd Rd, Baoan District, Shenzhen, China Manufacturer: Mekotronics Co., Ltd Address of Manufacturer: Rm1103-1105, Hengrong Lifang Building, Baomin 2 nd Rd, Baoan District, Shenzhen, China Factory: Mekotronics Co., Ltd Address of Factory: Rm1103-1105, Hengrong Lifang Building, Baomin 2 nd Rd, Baoan District, Shenzhen, China Equipment Under Test (EUT): EUT Name: 8 inch tablet Model No.: X8 Trade Mark: Reality Interactive FCC ID: 2AWPHFEX8V2 Standard(s) : 47 CFR Part 15, Subpart C 15.247 Date of Receipt: 2020-06-12 Date of Test: 2020-06-25 to 2020-07-08 Date of Issue: 2020-07-17 Test Result: Pass* * In the configuration tested, the EUT complied with the standards specified above. SGS-CSTC Standards Technical Services Co., Ltd. Shenzhen Branch Report No.: SZEM200600501402 Page: 2 of 106 Revision Record Version Chapter Date Modifier Remark 01 2020-07-17 Original Authorized for issue by: Leo Li /Project Engineer Eric Fu /Reviewer SGS-CSTC Standards Technical Services Co., Ltd. Shenzhen Branch Report No.: SZEM200600501402 Page: 3 of 106 2 Test Summary Radio Spectrum Technical Requirement Item Standard Method Requirement Result Antenna Requirement 47 CFR Part 15, Subpart C 15.247 N/A 47 CFR Part 15, Subpart C 15.203 & 15.247(b)(4) Pass Radio Spectrum Matter Part Item Standard Method Requirement Result Conducted Emissions at AC Power Line (150kHz-30MHz) 47 CFR Part 15, Subpart C 15.247 ANSI C63.10 (2013) Section 6.2 47 CFR Part 15, Subpart C 15.207 Pass Minimum 6dB Bandwidth 47 CFR Part 15, Subpart C 15.247 ANSI C63.10 (2013) Section 11.8.1 47 CFR Part 15, Subpart C 15.247a(2) Pass Conducted Peak Output Power 47 CFR Part 15, Subpart C 15.247 ANSI C63.10 (2013) Section 11.9.1 47 CFR Part 15, Subpart C 15.247(b)(3) Pass Power Spectrum Density 47 CFR Part 15, Subpart C 15.247 ANSI C63.10 (2013) Section 11.10.2 47 CFR Part 15, Subpart C 15.247(e) Pass Conducted Band Edges Measurement 47 CFR Part 15, Subpart C 15.247 ANSI C63.10 (2013) Section 11.13.3.2 47 CFR Part 15, Subpart C 15.247(d) Pass Conducted Spurious Emissions 47 CFR Part 15, Subpart C 15.247 ANSI C63.10 (2013) Section 11.11 47 CFR Part 15, Subpart C 15.247(d) Pass Radiated Emissions which fall in the restricted bands 47 CFR Part 15, Subpart C 15.247 ANSI C63.10 (2013) Section 6.10.5 47 CFR Part 15, Subpart C 15.209 & 15.247(d) Pass Radiated Spurious Emissions 47 CFR Part 15, Subpart C 15.247 ANSI C63.10 (2013) Section 6.4,6.5,6.6 47 CFR Part 15, Subpart C 15.209 & 15.247(d) Fail SGS-CSTC Standards Technical Services Co., Ltd. Shenzhen Branch Report No.: SZEM200600501402 Page: 4 of 106 3 Contents Page 1 COVER PAGE ..................................................................................................................................... 1 2 TEST SUMMARY ................................................................................................................................. 3 3 CONTENTS ......................................................................................................................................... 4 4 GENERAL INFORMATION .................................................................................................................. 6 4.1 DETAILS OF E.U.T. ......................................................................................................................... 6 4.2 DESCRIPTION OF SUPPORT UNITS .................................................................................................... 6 4.3 MEASUREMENT UNCERTAINTY ......................................................................................................... 7 4.4 TEST LOCATION ............................................................................................................................. 8 4.5 TEST FACILITY ............................................................................................................................... 8 4.6 DEVIATION FROM STANDARDS ......................................................................................................... 8 4.7 ABNORMALITIES FROM STANDARD CONDITIONS ................................................................................. 8 5 EQUIPMENT LIST ............................................................................................................................... 9 6 RADIO SPECTRUM TECHNICAL REQUIREMENT ............................................................................13 6.1 ANTENNA REQUIREMENT ................................................................................................................13 6.1.1 Test Requirement: ..................................................................................................................13 6.1.2 Conclusion ..............................................................................................................................13 7 RADIO SPECTRUM MATTER TEST RESULTS .................................................................................14 7.1 CONDUCTED EMISSIONS AT AC POWER LINE (150KHZ-30MHZ) ........................................................14 7.1.1 E.U.T. Operation .....................................................................................................................15 7.1.2 Test Setup Diagram ................................................................................................................15 7.1.3 Measurement Procedure and Data .........................................................................................15 7.2 MINIMUM 6DB BANDWIDTH .............................................................................................................18 7.2.1 E.U.T. Operation .........................................................β¦
Text truncated - open the document above for the full version.
SGS-CSTC Standards Technical Services Co., Ltd. Shenzhen Branch Page: 1 of 3 Setup Photos for SZEM2006005014CR FCC ID: 2AWPHFEX8V2 SGS-CSTC Standards Technical Services Co., Ltd. Shenzhen Branch Page: 2 of 3 1 Photographs 1.1 Conducted Emissions at AC Power Line (150kHz-30MHz) Test Setup SGS-CSTC Standards Technical Services Co., Ltd. Shenzhen Branch Page: 3 of 3 1.2 Radiated Spurious Emissions Test Setup
No.1 Workshop, M-10, Middle Section, Β· Shenzhen Β· China
| # | Rule Parts | Frequency Range | Power Output |
|---|---|---|---|
| 1 | 15C | 2.41 GHz - 2.46 GHz | 161.80 mW |

Media player
Equipment Class
DTS - Digital Transmission System
SparkBridge Media Player
Equipment Class
NII - Unlicensed National Information Infrastructure TX