
Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.
Dejana Truck & Utility Equipment Company, LLC. 500 Pulaski Rd. Kings Park, NY 11754 ph: 631.544.9000 fax: 631.544.0942 Dejana Power Lock Module User Manual Dejana Part Number: VICT VT-503 1)Key Fob Function Lock: Press the lock button once to lock the body compartments. Unlock: Press the unlock button once to unlock the body compartments. Compartment Lights*: Press the button once to turn on and again to turn off. Auxiliary*: Press button once to turn the Aux. output on and again to turn off. *Note: compartment lighting & auxiliary are optional items and may not be installed. Time out function: when the lock or unlock button is pressed repeatedly (more than 8 times in 30 seconds). Lock/unlock function will be disabled for 30 seconds before being restored. 2)Key Fob Battery Replacement Each key fob has one CR2032 button cell battery. Use a flat head screw driver to pry the back cover off. Remove the circuit board, slide the battery out of the holder and replace. The battery should be oriented so that the positive side faces up towards the plus symbol on the battery holder. Reassemble the fob housing by pressing the two halves together until they snap into place. Be sure the silicon seal mates correctly to maintain water resistance. 3)LED Flash Signal (LED on module) 1 flash: lock output active 2 flashes: unlock output active 3 flashes: compartment lighting output turned on/off 4 flashes: AUX2 output turned on/off Continuously on: module in programming mode Dejana Truck & Utility Equipment Company, LLC. 500 Pulaski Rd. Kings Park, NY 11754 ph: 631.544.9000 fax: 631.544.0942 4)Programming A Key Fob 1)P ress the learn code button on the top of the module three times. The LED indicator will turn on and remain on while the module is in programming mode. It will exit this mode if a remote is not programmed within 10 seconds. Note: the module must be supplied with 12V power. 2)Press any button on the remote to be programmed. You will see the LED turn off and back on to indicate the key fob was programmed correctly. 3)Repeat step 2 for all key fobs. The module may be programmed with up to 4 key fobs. Any remotes not programmed during this process will be removed from memory. 4)The module will exit programming mode automatically after 10 seconds of inactivity or after a 4 th key fob has been programmed. 5)Lock/unlock hardwired switch (optional accessory) The module can be connected to a hardwired momentary lock/unlock switch. Two pins in the module 10 pin connector are for lock/unlock signal inputs. Lock: pin 8 (20 AWG green-white), unlock: pin 2 (20 AWG blue-white). When the module receives a momentary positive (12V) signal on pin 8 or 2, the doors will lock or unlock as if the corresponding button were pressed. 6) AUX1: Compartment Light Output (optional accessory) The module has an output intended to control a relay which can be used for compartment lighting. The lights will turn on when the vehicle is unlocked or when activated from the key fob (press AUX1) and will turn off after 10 minutes or when deactivated by the key fob (press AUX1 again). Pin #3 of the 10 pin connector (GRN 20 AWG) supplies a switched ground signal when the compartment lights are turned on and an open circuit when the lights are off. Do not wire the module directly to lights, this circuit must use a relay to handle the lighting load. 7)AUX2: Auxiliary Output (optional accessory) AUX2 controls a switched ground signal on pin #9 of the 10 pin connector (orange 20 AWG). This is intended to drive an external relay for any use. The output turns on when AUX2 is pressed and off when AUX2 is pressed again or after 10 minutes. 8)Wiring Diagram Note: Wire color and AWG refer to Dejana wiring harness DTH 01-1180-003 Dejana Truck & Utility Equipment Company, LLC. 500 Pulaski Rd. Kings Park, NY 11754 ph: 631.544.9000 fax: 631.544.0942 FCC Warning This device complies with part 15 of the FCC rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any inte rference received, including interference that may cause undesired operation. Changes or modifications not expressly approved by the party responsible for compliance could void the user's authority to operate the equipment. NOTE: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against ha rmful interference in a residential installation. This equipment generates uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interferenceto radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures: • Reorient or relocate the receiving antenna. • Increase the separation between the equipment and receiver. • Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. • Consult the dealer or an experienced radio/TV technician for help. Radiation Exposure Statement The device has been evaluated to meet general RF exposure requirement. The device can be used in portable exposure condition without restriction.
LocalRepresentativeLetter ForCertificationServiceintheUSA FederalCommunicationsCommission EquipmentAuthorizationDivision,ApplicationProcessingBranch 7435OaklandMillsRoad Columbia,MD21048 Towhomitmayconcern PursuanttoSection2.911(d)(7),oftheCommission’sRules(47C.F.R.)weattestasfollowsfor theproductlistedbelow: FCCIDModelname 2AWPMVT-503-1VICTVT-503 Weherebyacknowledgeasfollows: i.bothsigneesconfirmthatthepointofcontactacceptsresponsibilitytoactasaUS- AmericanRepresentativeonbehalfoftheapplicant ii.thepointofcontactprovidesthephysicalU.S.addressandemailaslistedbelow iii.bothpartiesmaintaintherequirementsofthisagreementfornolessthanoneyear afterthegranteehasterminatedallmarketingandimportationortheconclusionof anyCommission-relatedproceedinginvolvingtheequipment. iv.Anexpirationdateforthisletterdoesnotexist.IncasetheU.S.agentchanges,the granteeisobligatedtonotifytheFCCwithin30daysviathegrantingTCB. US-AmericanPointofContactApplicant/ApprovalHolder Signature:Signature: SignatureDate:2026-5-6SignatureDate:2026-5-6 CompanyName:DejanaTruck&UtilityEquipment Co,LLC DejanaTruck&UtilityEquipment Co,LLC FRN:00296956650029695665 ContactName:CharlieHanleyCharlieHanley Address:500PulaskiRoad,KingsParkKings ParkNewYork11754UnitedStates 500PulaskiRoad,KingsPark KingsParkNewYork11754 UnitedStates Phone:(888)836-0649(888)836-0649 Email:[email protected]@dejana.com
Covered Equipment Attestation Letter For Certification Service in the USA Federal Communications Commission Equipment Authorization Division, Application Processing Branch 7435 Oakland Mills Road Columbia, MD 21048 To whom it may concern Pursuant to Section 2.911(d)(5)(i)-(ii) of the Commission’s Rules (47 C.F.R.) we attest as follows for the product listed below: FCC ID Model name 2AWPMVT-503-1 VICT VT-503 We, Applicant Company Name: Dejana Truck & Utility Equipment Co, LLC Address: 500 Pulaski Road, Kings Park Kings Park, New York 11754, United States Phone: +1-888-836-0649 certify that the equipment for which authorization is sought is not “covered” equipment prohibited from receiving an equipment authorization pursuant to section 2.903 of the FCC rules. This includes the cybersecurity and anti-virus software produced or provided by Kaspersky Lab, Inc. or any of ist successors and assignees. We certify that, as of the date of the filing of the application, the applicant is not identified on the Covered List as an entity producing “covered” equipment. If you have any questions, please feel free to contact us at the address shown below. Sincerely, 2026-05-06 Signature Date Name / Title: Charlie Hanley / Senior Director, Engineering Company: Dejana Truck & Utility Equipment Co, LLC Address: 500 Pulaski Road, Kings Park Kings Park, New York 11754, United States Phone: +1-888-836-0649 Fax: +1-631-544-0942 E-Mail: [email protected]
Due Diligence Letter For Certification Service in the USA Federal Communications Commission Equipment Authorization Division, Application Processing Branch 7435 Oakland Mills Road Columbia, MD 21048 To whom it may concern FCC ID Model name 2AWPMVT-503-1 VICT VT-503 Pursuant to KDB 986446 D01 Covered Equipment Guidance the evaluation of the product above shows compliance for the following reasons: Compliance Evaluation process Results Inherent compliance The chipset(s) used is not capable of running the cybersecurity and/or anti-virus software Compliance The memory used does not allow the running the cybersecurity and/or anti-virus software Compliance The storage capacity does not allow the running the cybersecurity and/or anti-virus software Compliance The operating system used is not capable of running the cybersecurity and/or anti-virus software Compliance No inherent compliance Based on software bill of material Based on scan for running software on the device Based on filesystem scan for cybersecurity and/or anti-virus software The equipment for which authorization is sought complies with the rules and fulfils the requirements as detailed in the above mentioned KDB. Evaluation performed by Company Name: Shenzhen LCS Compliance Testing Laboratory Ltd. Contact Name: Martion Lee Address: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Phone: +86-755-82591330 Email: [email protected] Signature: Date: 2026-04-20
Confidentiality Request Letter For Certification Service in the USA Federal Communication Commission Equipment Authorization Division, Application Processing Branch 7435 Oakland Mills Road Columbia, MD 21048 To whom it may concern Pursuant to Paragraphs §0.457 and 0.459 of the Commission’s Rules (47 C.F.R.) and Section §552(b)(4) of the Freedom of Information Act, we request confidentiality for the documentation of the following products: FCC ID Model name 2AWPMVT-503-1 VICT VT-503 For the products listed above, we request permanent confidentiality for all applicable exhibits as there are: • the Operational Description • the Block Diagram • the Schematics • the Part List • the Tune up Information The above listed exhibits contain trade secrets and proprietary information that could be of benefit to our competitors. If you have any questions, please feel free to contact us at the address shown below. Sincerely, 2026-05-06 Signature Date Name / Title: Charlie Hanley / Senior Director, Engineering Company: Dejana Truck & Utility Equipment Co, LLC Address: 500 Pulaski Road, Kings Park Kings Park, New York 11754, United States Phone: +1-888-836-0649 Fax: +1-631-544-0942 E-Mail: [email protected]
Page 1 of 4 FCC ID: 2AWPMVT-503-1 Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity External Photos of the EUT Fig. 1 Fig. 2 Page 2 of 4 FCC ID: 2AWPMVT-503-1 Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity Fig. 3 Fig. 4 Page 3 of 4 FCC ID: 2AWPMVT-503-1 Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity Fig. 5 Fig. 6 Page 4 of 4 FCC ID: 2AWPMVT-503-1 Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity Fig. 7
Page 1 of 1 FCC ID: 2AWPMVT-503-1 Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity LABEL AND LOCATION (Size: L2.0cm x W1.0cm) Power Locking System Model: VICT VT-503 FCC ID: 2AWPMVT-503-1 Label Location
Page 1 of 2 FCC ID: 2AWPMVT-503-1 Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity Internal Photos of the EUT Fig. 1 Fig. 2 433MHz Antenna Page 2 of 2 FCC ID: 2AWPMVT-503-1 Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity Fig. 3 Fig. 4
Page 1 of 9 FCC ID: 2AWPMVT-503-1 Report No.: LCSA04016005EB Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity RF Exposure Evaluation For Dejana Truck & Utility Equipment Co, LLC Power Locking System Test Model: VICT VT-503 Prepared for : Dejana Truck & Utility Equipment Co, LLC Address : 500 Pulaski Road Kings Park, New York, 11754, United States Prepared by : Shenzhen LCS Compliance Testing Laboratory Ltd. Address : 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel : (+86)755-82591330 Fax : (+86)755-82591332 Web : www.LCS-cert.com Mail : [email protected] Date of receipt of test sample : April 02, 2026 Number of tested samples : 2 Sample No. : A260323137-1, A260323137-2 Serial number : Prototype Date of Test : April 02, 2026 ~ April 17, 2026 Date of Report : April 20, 2026 Page 2 of 9 FCC ID: 2AWPMVT-503-1 Report No.: LCSA04016005EB Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity RF Exposure Evaluation Report Reference No. .............. : LCSA04016005EB Date of Issue ............................... : April 20, 2026 Testing Laboratory Name ......... : Shenzhen LCS Compliance Testing Laboratory Ltd. Address ...................................... : 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Testing Location/ Procedure ....... : Full application of Harmonised standards ■ Partial application of Harmonised standards □ Other standard testing method □ Applicant’s Name ...................... : Dejana Truck & Utility Equipment Co, LLC Address ...................................... : 500 Pulaski Road Kings Park, New York, 11754, United States Test Specification Standard ..................................... : FCC KDB publication 447498 D01 General 1 RF Exposure Guidance v06 FCC CFR 47 part1 1.1310 FCC CFR 47 part2 2.1093 Test Report Form No. ............... : TRF-4-E-215 A/0 TRF Originator ............................ : Shenzhen LCS Compliance Testing Laboratory Ltd. Master TRF ................................. : Dated 2011-03 Shenzhen LCS Compliance Testing Laboratory Ltd. All rights reserved. This publication may be reproduced in whole or in part for non-commercial purposes as long as the Shenzhen LCS Compliance Testing Laboratory Ltd. is acknowledged as copyright owner and source of the material. Shenzhen LCS Compliance Testing Laboratory Ltd. takes no responsibility for and will not assume liability for damages resulting from the reader's interpretation of the reproduced material due to its placement and context. Test Item Description. ............... : Power Locking System Trade Mark ................................. : N/A Test Model .................................. : VICT VT-503 Ratings ....................................... : Please Refer to Page 6 Result ........................................ : PASS Compiled by: Supervised by: Approved by: Jack Liu/ Administrator Kevin Huang/ RF Manager Gavin Liang/ Manager Page 3 of 9 FCC ID: 2AWPMVT-503-1 Report No.: LCSA04016005EB Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity RF Exposure Evaluation Test Result PASS The test report merely corresponds to the test sample. It is not permitted to copy extracts of these test result without the written permission of the test laboratory. Test Report No. : LCSA04016005EB April 20, 2026 Date of issue EUT...................................... ... : Power Locking System Test Model........................... : VICT VT-503 Applicant............................. : Dejana Truck & Utility Equipment Co, LLC Address................................ : 500 Pulaski Road Kings Park, New York, 11754, United States Telephone............................ ... : / Fax....................................... ... : / Manufacturer...................... : GUANGDONG VICTOR ELECTRONICS CO.,LTD. Address................................ : 3/F, Building 19, No.16 Chuangye Road, Torch Development Zone, Zhongshan City, Guangdong Province, China. Telephone............................ ... : / Fax....................................... ... : / Factory................................ : GUANGDONG VICTOR ELECTRONICS CO.,LTD. Address................................ : 3/F, Building 19, No.16 Chuangye Road, Torch Development Zone, Zhongshan City, Guangdong Province, China. Telephone............................ ... : / Fax....................................... ... : / Page 4 of 9 FCC ID: 2AWPMVT-503-1 Report No.: LCSA04016005EB Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity Revision History Report Version Issue Date Revision Content Revised By 000 April 20, 2026 Initial Issue --- Page 5 of 9 FCC ID: 2AWPMVT-503-1 Report No.: LCSA04016005EB Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity TABLE OF CONTE…
Text truncated - open the document above for the full version.
Item Model Name 433.72MHz433.92MHz434.12MHz433.72MHz434.12MHz -0.150-0.13-0.23-0.22 Maximum gain Polarization Method Impedance Antenna Type Manufacturer Address PCB Antenna(V905GM-2) PCB ANTENNA 3/F, Building 19, No.16 Chuangye Road, Torch Development Zone, Zhongshan City, Guangdong Province, China. 50ohm PCB Antenna GUANGDONG VICTOR ELECTRONICS CO.,LTD. Antenna Specification HorizontalVertical 0dBi Horizontal and Vertical Center frequency We statement that All measurements were performed radiated and therefore additional antenna gain documentation is not required.
Page 1 of 28 FCC ID: 2AWPMVT-503-1 Report No.: LCSA04016005EA Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity FCC TEST REPORT For Dejana Truck & Utility Equipment Co, LLC Power Locking System Test Model: VICT VT-503 Prepared for : Dejana Truck & Utility Equipment Co, LLC Address : 500 Pulaski Road Kings Park, New York, 11754, United States Prepared by : Shenzhen LCS Compliance Testing Laboratory Ltd. Address : 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel : (+86)755-82591330 Fax : (+86)755-82591332 Web : www.LCS-cert.com Mail : [email protected] Date of receipt of test sample : April 02, 2026 Number of tested samples : 2 Sample No. : A260323137-1, A260323137-2 Serial number : Prototype Date of Test : April 02, 2026 ~ April 17, 2026 Date of Report : April 20, 2026 Page 2 of 28 FCC ID: 2AWPMVT-503-1 Report No.: LCSA04016005EA Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity FCC TEST REPORT FCC CFR 47 PART 15 C(15.231) Report Reference No. .............. : LCSA04016005EA Date of Issue ............................... : April 20, 2026 Testing Laboratory Name ......... : Shenzhen LCS Compliance Testing Laboratory Ltd. Address ...................................... : 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Testing Location/ Procedure ....... : Full application of Harmonised standards ■ Partial application of Harmonised standards □ Other standard testing method □ Applicant’s Name ...................... : Dejana Truck & Utility Equipment Co, LLC Address ...................................... : 500 Pulaski Road Kings Park, New York, 11754, United States Test Specification Standard ..................................... : FCC CFR 47 PART 15 Subpart C, ANSI C63.10-2020 Test Report Form No. ............... : TRF-4-E-176 A/0 TRF Originator ............................ : Shenzhen LCS Compliance Testing Laboratory Ltd. Master TRF ................................. : Dated 2011-03 Shenzhen LCS Compliance Testing Laboratory Ltd. All rights reserved. This publication may be reproduced in whole or in part for non-commercial purposes as long as the Shenzhen LCS Compliance Testing Laboratory Ltd. is acknowledged as copyright owner and source of the material. Shenzhen LCS Compliance Testing Laboratory Ltd. takes no responsibility for and will not assume liability for damages resulting from the reader's interpretation of the reproduced material due to its placement and context. Test Item Description. ............... : Power Locking System Trade Mark ................................. : N/A Test Model .................................. : VICT VT-503 Ratings ....................................... : Please Refer to Page 6 Result ........................................ : PASS Compiled by: Supervised by: Approved by: Jack Liu/ Administrator Kevin Huang/ RF Manager Gavin Liang/ Manager Page 3 of 28 FCC ID: 2AWPMVT-503-1 Report No.: LCSA04016005EA Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity FCC -- TEST REPORT Test Result PASS The test report merely corresponds to the test sample. It is not permitted to copy extracts of these test result without the written permission of the test laboratory. Test Report No. : LCSA04016005EA April 20, 2026 Date of issue EUT...................................... ... : Power Locking System Test Model........................... : VICT VT-503 Applicant............................. : Dejana Truck & Utility Equipment Co, LLC Address................................ : 500 Pulaski Road Kings Park, New York, 11754, United States Telephone............................ ... : / Fax....................................... ... : / Manufacturer...................... : GUANGDONG VICTOR ELECTRONICS CO.,LTD. Address................................ : 3/F, Building 19, No.16 Chuangye Road, Torch Development Zone, Zhongshan City, Guangdong Province, China. Telephone............................ ... : / Fax....................................... ... : / Factory................................ : GUANGDONG VICTOR ELECTRONICS CO.,LTD. Address................................ : 3/F, Building 19, No.16 Chuangye Road, Torch Development Zone, Zhongshan City, Guangdong Province, China. Telephone............................ ... : / Fax....................................... ... : / Page 4 of 28 FCC ID: 2AWPMVT-503-1 Report No.: LCSA04016005EA Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity Revision History Report Version Issue Date Revision Content Revised By 000 April 20, 2026 Initial Issue -- Page 5 of 28 FCC ID: 2AWPMVT-503-1 Report No.: LCSA04016005EA Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity TABLE OF CONTENTS 1. GENERAL INFORMATION .........................…
Text truncated - open the document above for the full version.
Page 1 of 1 FCC ID: 2AWPMVT-503-1 Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity Test Setup Photos of the EUT Test Setup Photo(s) of Radiated Emissions Measurement Fig. 1 Fig. 2
500 Pulaski Road, Kings Park Kings Park, · New York, 11754 · United States
| # | Rule Parts | Frequency Range | Power Output |
|---|---|---|---|
| 1 | 15.231 | 433.92 MHz - 433.92 MHz | - |