Application Details

Equipment Class
DCD - Part 15 Low Power Transmitter Below 1705 kHz
Date of Grant
Jun 23, 2020
Application Purpose
Original Equipment
Date of Application
Jun 23, 2020
Equipment Note
2 in 1 Wireless Charger with Watch Holder
Frequency Range
0.12500000 - 0.12500000
Company
WuHan Fred Trading Co., Ltd.
Country
China

Documents & Files

Select a file to view

Users Manual

↗

Cover Letter(s)

↗
↗

External Photos

↗

ID Label/Location Info

↗

Internal Photos

↗

RF Exposure Info

↗

Test Report

↗

Test Setup Photos

↗

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

Users Manual

PZOZ 2 in 1 Wireless Charger Product Manual Product Type: PZOZ-WCH-001 1. 2 in 1 Design for Apple Watch and iPhone. Wireless charger provides a 10W (Max) wireless charge for iPhone. 2. Apple watch foldable charging stand only compatible with original Apple Watch Charger Cable. 3. Works safe with all cell phones that support wireless charging. 4. Product Parameters Input: 5V/2A, 9V/2A, 12V/1.5A (Max). Output: 5W /7.5W /10W. (Included 3.3 ft USB-C cable, NO Adapter). To ensure mobile phone charging speed, we recommend using a wall charger with a power greater than 7.5W. 5. Description of charging modes for Cell phones and Apple Watch: The LED Indicator allows you to easily check the charging status of your device. Red light: Standby Green light: Charging Lights out: Charging is Complete & tĂƌŶŝŶŐ ^ƚĂƚĞŵĞŶƚ ŚĂŶŐĞƐ Žƌ ŵŽĚŝĨŝĐĂƚŝŽŶƐ ŶŽƚ ĞdžƉƌĞƐƐůLJ ĂƉƉƌŽǀĞĚ ďLJ ƚŚĞ ƉĂƌƚLJ ƌĞƐƉŽŶƐŝďůĞ ĨŽƌ ĐŽŵƉůŝĂŶĐĞ ĐŽƵůĚ ǀŽŝĚ ƚŚĞ ƵƐĞƌ͛Ɛ ĂƵƚŚŽƌŝƚLJ ƚŽ ŽƉĞƌĂƚĞ ƚŚĞ ĞƋƵŝƉŵĞŶƚ͘ dŚŝƐ ĞƋƵŝƉŵĞŶƚ ŚĂƐ ďĞĞŶ ƚĞƐƚĞĚ ĂŶĚ ĨŽƵŶĚ ƚŽ ĐŽŵƉůLJ ǁŝƚŚ ƚŚĞ ůŝŵŝƚƐ ĨŽƌ Ă ůĂƐƐ  ĚŝŐŝƚĂů ĚĞǀŝĐĞ͕ ƉƵƌƐƵĂŶƚ ƚŽ WĂƌƚ ϭρ ŽĨ ƚŚĞ & ZƵůĞƐ͘ dŚĞƐĞ ůŝŵŝƚƐ Ăƌ Ğ ĚĞƐŝŐŶĞĚ ƚŽ Ɖƌ ŽǀŝĚĞ ƌĞĂƐŽŶĂďůĞ ƉƌŽƚĞĐƚŝŽŶ ĂŐĂŝŶƐƚ ŚĂƌŵĨƵů ŝŶƚĞƌĨĞƌĞŶĐĞ ŝŶ Ă ƌĞƐŝĚĞŶƚŝĂů ŝŶƐƚĂůůĂƚŝŽŶ͘ dŚŝƐ ĞƋƵŝƉŵĞŶƚ ŐĞŶĞƌĂƚĞƐ ƵƐĞƐ ĂŶĚ ĐĂŶ ƌĂĚŝĂƚĞ ƌĂĚŝŽ ĨƌĞƋƵĞŶĐLJ ĞŶĞƌŐLJ ĂŶĚ͕ ŝĨ ŶŽƚ ŝŶƐƚĂůůĞĚ ĂŶĚ ƵƐĞĚ ŝŶ ĂĐĐŽƌĚĂŶĐĞ ǁŝƚŚ ƚŚĞ ŝŶƐƚƌƵĐƚŝŽŶƐ͕ ŵĂLJ ĐĂƵƐĞ ŚĂƌŵĨƵů ŝŶƚĞƌĨĞƌĞŶĐĞ ƚŽ ƌĂĚŝŽ ĐŽŵŵƵŶŝĐĂƚŝŽŶƐ͘ ,ŽǁĞǀĞƌ͕ ƚŚĞƌĞ ŝƐ ŶŽ ŐƵĂƌĂŶƚĞĞ ƚŚĂƚ ŝŶƚĞƌĨĞƌĞŶĐĞ ǁŝůů ŶŽƚ ŽĐĐƵƌ ŝŶ Ă ƉĂ ƌ ƚŝĐƵůĂƌ ŝŶƐƚĂůůĂƚŝŽŶ͘ /Ĩ ƚŚŝƐ ĞƋƵŝƉŵĞŶƚ ĚŽĞƐ ĐĂƵƐĞ ŚĂƌŵĨƵů ŝŶƚĞƌĨĞƌĞŶĐĞ ƚŽ ƌĂĚŝŽ Žƌ ƚĞůĞǀŝƐŝŽŶ ƌĞĐĞƉƚŝŽŶ͕ ǁŚŝĐŚ ĐĂŶ ďĞ ĚĞƚĞƌŵŝŶĞĚ ďLJ ƚƵƌŶŝŶŐ ƚŚĞ ĞƋƵŝƉŵĞŶƚ ŽĨĨ ĂŶĚ ŽŶ͕ ƚŚĞ ƵƐĞƌ ŝƐ ĞŶĐŽƵƌĂŐĞĚ ƚŽ ƚƌLJ ƚŽ ĐŽƌƌĞĐƚ ƚŚĞ ŝŶƚĞƌĨĞƌĞŶĐĞ ďLJ ŽŶĞ Žƌ ŵŽƌĞ ŽĨ ƚŚĞ ĨŽůůŽǁŝŶŐ ŵĞĂƐƵƌĞƐ͗ ‐‐ ZĞŽƌŝĞŶƚ Žƌ ƌĞůŽĐĂƚĞ ƚŚĞ ƌ ĞĐĞŝǀŝŶŐ ĂŶ ƚĞŶŶĂ͘ ‐‐ /ŶĐƌĞĂƐĞ ƚŚĞ ƐĞƉĂƌĂƚŝŽŶ ďĞƚǁĞĞŶ ƚŚĞ ĞƋƵŝƉŵĞŶƚ ĂŶĚ ƌĞĐĞŝǀĞƌ͘ ‐‐ ŽŶŶĞĐƚ ƚŚĞ ĞƋƵŝƉŵĞŶƚ ŝŶƚŽ ĂŶ ŽƵƚůĞƚ ŽŶ Ă ĐŝƌĐƵŝƚ ĚŝĨĨĞƌĞŶƚ ĨƌŽŵ ƚŚĂƚ ƚŽ ǁŚŝĐŚ ƚŚĞ ƌĞĐĞŝǀĞƌ ŝƐ ĐŽŶŶĞĐƚĞĚ͘ ‐‐ ŽŶƐƵůƚ ƚŚĞ ĚĞĂůĞƌ Žƌ ĂŶ ĞdžƉĞƌŝĞŶĐĞĚ ƌĂĚŝŽͬds ƚĞĐŚŶŝĐŝĂŶ ĨŽƌ ŚĞůƉ͘ Z& džƉŽƐƵƌĞ͗  ĚŝƐƚĂŶĐĞ ŽĨ ϭρ Đŵ ƐŚĂůů ďĞ ŵĂŝŶƚĂŝŶĞĚ ďĞƚǁĞĞŶ ƚŚĞ ĂŶƚĞŶŶĂ ĂŶĚ ƵƐĞƌƐ͕ ĂŶĚ ƚŚĞ ƚƌĂŶƐŵŝƚƚĞƌ ŵĂLJ ŶŽƚ ďĞ ĐŽ‐ůŽĐĂƚĞĚ ǁŝƚŚ ĂŶLJ ŽƚŚĞƌ ƚƌĂŶƐŵŝƚƚĞƌ Žƌ ĂŶƚĞŶŶĂ͘ dŚŝƐĚĞǀŝĐĞĐŽŵƉůŝĞƐǁŝƚŚƉĂƌƚϭρŽĨƚŚĞ&ZƵůĞƐ͘KƉĞƌĂƚŝŽŶŝƐƐƵďũĞĐƚƚŽƚŚĞĨŽůůŽǁŝŶŐƚǁŽĐŽŶĚŝƚŝŽŶƐ͗ ;ϭͿdŚ ŝƐĚĞǀŝĐĞŵĂLJŶŽƚĐĂƵƐĞŚĂƌŵĨƵůŝŶƚĞƌĨĞƌĞŶĐĞ͕ĂŶĚ;ϮͿƚŚŝƐĚĞǀŝĐĞŵƵƐƚĂĐĐĞƉƚĂŶLJŝŶƚĞƌĨĞƌĞŶĐĞƌĞĐĞŝ ǀĞĚ͕ŝŶĐůƵĚŝŶŐŝŶƚĞƌĨĞƌĞŶĐĞƚŚĂƚŵĂLJĐĂƵƐĞƵŶĚĞƐŝƌĞĚŽƉĞƌĂƚŝŽŶ͘

Cover Letter(s)

Co m Ad d Jian Pr o Mo d Pr o We act We an d issu our Sig Na m Title Com mpany: Wu dress: No1 ngan, Wuh oduct Name del Numbe oduct Desc authorize M on our beha declare tha d certificatio ues concern behalf shal nature: me: e: mpany: uHan Fred 1, 15/F, A, an, China e: 2 in 1 Wi er(s): PZOZ ription: 2 in MiCOM Lab alf on all ma at MiCOM L n of equipm ning the app ll have the s Di Ming Li General M WuHan Fr WuHa Agen Trading Co Huazhong ireless Cha Z-WCH-001 n 1 Wireles bs Inc., 575 atters conce Labs Inc. is ment to the r proval applic same effect Manager red Trading an Fred Tra nt Auth o., Ltd. Internatio arger with W ss Charger Boulder Co erning the c allowed to f regulatory a cation. Any t as acts of Co., Ltd. ading Co., L horizat nal Plaza H Watch Hold r with Watc ourt, Pleasa certification forward all i agencies as and all acts our own. Ltd. tion Huang Xiao der ch Holder anton, Califo of above na information s required a s carried ou Date: o He Rd, Hu ornia 94566 amed equip related to t nd to discu ut by MiCOM Jun. 19, 20 uaqiao St, 6, USA, to pment. the approva ss any M Labs on 20 al

Cover Letter(s)

WuHan Fred Trading Co., Ltd. Office of Engineering Technology Federal Communications Commission 7435 Oakland Mills Road Columbia, MD 21046 USA Date: Jun. 19, 2020 Subject; Request for Confidentiality FCC ID: 2AWPQ-PZOZWCH001 To Whom It May Concern, Pursuant to the provisions of the Commission’s rules Title 47 Sections §0.457 and §0.459, we are requesting the Commission to withhold the following attachment(s) as confidential documents from public disclosure indefinitely. These documents contain detailed system and equipment descriptions and are considered as proprietary information in operation of the equipment. The public disclosure of these documents might be harmful to our company and would give competitors an unfair advantage in the market. Schematic Diagram Block Diagram Parts List Operational Description It is our understanding that all measurement test reports, FCC ID label format and correspondence during the certification review process cannot be granted as confidential documents and this information will be available for public review once the grant of equipment authorization is issued. Sincerely, Signature: Name: Di Ming Li Title: General Manager

External Photos

Annex A External Photos Report No.: HK2006091310‐1E/2E Page 1 of 4 Report No.: HK2006091310‐1E/2E Page 2 of 4 Report No.: HK2006091310‐1E/2E Page 3 of 4 Report No.: HK2006091310‐1E/2E Page 4 of 4

ID Label/Location Info

FCC ID LABEL: Label Location Width: 2cm Long: 4cm FCC ID: 2AWPQ-PZOZWCH001 Product name: 2 in 1 Wireless Charger with Watch Holder Model No.: PZOZ-WCH-001 This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1)This device may not cause harmful interference, and (2)This device must accept any interference received, including interference that may cause undesired operation.

Internal Photos

Annex B Internal Photo Report No.:HK2006091310-1E/2E Page 1 of 2 Antenna Report No.:HK2006091310-1E/2E Page 2 of 2

RF Exposure Info

Page 1 of 8 Report No.: HK2006091310-2E FCC TEST REPORT Test report On Behalf of WuHan Fred Trading Co., Ltd. For 2 in 1 Wireless Charger with Watch Holder Model No.: PZOZ-WCH-001 FCC ID: 2AWPQ-PZOZWCH001 Prepared for : WuHan Fred Trading Co., Ltd. No11, 15/F, A, Huazhong International Plaza Huang Xiao He Rd, Huaqiao St, Jiangan, Wuhan, China Prepared By : Shenzhen HUAK Testing Technology Co., Ltd. 1F, B2 Building, Junfeng Zhongcheng Zhizao Innovation Park, Fuhai Street, Bao'an District, Shenzhen City, China Date of Test: Jun. 08, 2020 ~Jun. 15, 2020 Date of Report: Jun. 15, 2020 Report Number: HK2006091310-2E Page 2 of 8 Report No.: HK2006091310-2E Note: 1. For a more detailed features description, please refer to the manufacturer’s specifications or the User's Manual. 2. Channel List Channel Frequency (KHz) Channel Frequency (MHz) Channel Frequency (MHz) Channel Frequency (MHz) 01 125 The EUT antenna is Coil Antenna. No antenna other than that furnished by the responsible party shall be used with the device. 2. SUMMARY OF TEST RESULTS 2.1 Test procedures according to the technical standards: FCC KDB680106 D01 RF Exposure Wireless Charging Apps v03 FCC CFR 47 Standard Section Test Item Judgment Remark FCC CFR 47 part1, 1.1310 KDB680106 D01v03 (3)(3) Electric Field Strength (E) (V/m) PASS Magnetic Field Strength (H) (A/m) PASS 2.2 MEASUREMENT UNCERTAINTY The reported uncertainty of measurement y ±U,where expended uncertainty U is based on a standard uncertainty multiplied by a coverage factor of k=2,providing a level of confidence of approximately 95 %。 No. Item Uncertainty 1 All emissions,radiated(<30M)(9KHz-30MHz) ±2.45dB 2 Temperature ±0.5°C 3 Humidity ±2% Page 3 of 8 Report No.: HK2006091310-2E 2.3 Test Instruments Description Brand Model No. Frequency Range Calibrated Date Calibrated Until Broadband Field Meter NARDA NBM-550 - Dec. 26, 2019 Dec. 25, 2020 Magnetic Field Meter NARDA ELT-400 1 – 400kHz Dec. 26, 2019 Dec. 25, 2020 Magnetic Probe NARDA HF-3061 300kHz – 30MHz Dec. 26, 2019 Dec. 25, 2020 Magnetic Probe NARDA HF-0191 27 – 1000MHz Dec. 26, 2019 Dec. 25, 2020 Broadband Field Meter NARDA NBM-550 - Dec. 26, 2019 Dec. 25, 2020 Electric Field Meter COMBINOVA EFM 2005Hz – 400kHz Dec. 26, 2019 Dec. 25, 2020 E-Field Probe NARDA EF-0391 100kHz – 3GHz Dec. 26, 2019 Dec. 25, 2020 E-Field Probe NARDA EF-6091 100MHz – 60GHz Dec. 26, 2019 Dec. 25, 2020 NOTE: 1. The calibration interval of the above test instruments is 12 months . Page 4 of 8 Report No.: HK2006091310-2E 3. MAXIMUM PERMISSIBLE EXPOSURE 3.1 MAXIMUM PERMISSIBLE EXPOSURE Limit of Maximum Permissible Exposure Limits for Occupational / Controlled Exposure Frequency Range (MHz) Electric Field Strength (E) (V/m) Magnetic Field Strength (H) (A/m) Power Density (S) (mW/ cm²) Averaging Time |E|²,|H|² or S (minutes) 0.3-3.0 614 1.63 (100)* 6 3.0-30 1842 / f 4.89 / f (900 / f)* 6 30-300 61.4 0.163 1.0 6 300-1500 F/300 6 1500-100,000 5 6 Limits for General Population / Uncontrolled Exposure Frequency Range (MHz) Electric Field Strength (E) (V/m) Magnetic Field Strength (H) (A/m) Power Density (S) (mW/ cm²) Averaging Time |E|²,|H|² or S (minutes) 0.3-1.34 614 1.63 (100)* 30 1.34-30 824/f 2.19/f (180 / f)* 30 30-300 27.5 0.073 0.2 30 300-1500 F/1500 30 1500-100,000 1 30 Note 1: f = frequency in MHz ; *Plane-wave equivalent power density Note 2: For the applicable limit, see FCC 1.1310, 680106 D01 RF Exposure Wireless Charging Apps v03 Note 3: Emissions between 100 kHz to 300 kHz should be assessed versus the limits at 300 kHz in Table 1 of Section 1.1310: 614 V/m and 1.63A/m. A KDB inquiry is required to determine the applicable exposure limits below 100 kHz. Page 5 of 8 Report No.: HK2006091310-2E 4. TEST PROCEDURE a. For devices designed for typical desktop applications, such a wireless charging pads, RF exposure evaluation should be conducted assuming a user separation distance of (H-field & E- field strengths for all sides is 15cm, H-field strengths of top side is 20cm). E and H field strength measurements or numerical modeling may be used to demonstrate compliance. Measurements should be made from all sides and the top of the primary/client pair, with the 15 cm measured from the center of the probe(s) to the edge of the device. 4.1 TEST SETUP 4.2 RESULT OF MAXIMUM PERMISSIBLE EXPOSURE Page 6 of 8 Report No.: HK2006091310-2E For Full load mode: E-Field Strength at 15 cm from the edges surrounding the EUT (V/m) Frequency Range (MHz) Test Position A Test Position B Test Position C Test Position D Test Position E Limits Test (V/m) 0.125 1.24 1.66 1.37 1.63 1.33 614 H-Field Strength at 15 cm from the edges surrounding the EUT (A/m) Frequency Range (MHz) Test Position A Test Position B Test Position C Test Position D Test Position E Limits Test (A/m) 0.125 0.22 0.57 0.46 0.28 0.31 1.63 For Half Load mode: E-Field Strength at 15 cm from the edges surrounding the EUT (V/m) Frequency Range (MHz) Test Position A Test Position B Test Position C Test Position D Test Position E Limits Test (V/m) 0.125 1.66 1.37 1.54 1.21 1.23 614 H-Field Strength at 15 cm from the edges surrounding the EUT (A/m) Frequency Range (MHz) Test Position A Test Position B Test Position C Test Position D Test Position E Limits Test (A/m) 0.125 0.47 0.39 0.55 0.31 0.44 1.63 Page 7 of 8 Report No.: HK2006091310-2E For No load mode: E-Field Strength at 15 cm from the edges surrounding the EUT (V/m) Frequency Range (MHz) Test Position A Test Position B Test Position C Test Position D Test Position E Limits Test (V/m) 0.125 1.52 1.33 1.35 1.63 1.44 614 H-Field Strength at 15 cm from the edges surrounding the EUT (A/m) Frequency Range (MHz) Test Position A Test Position B Test Position C Test Position D Test Position E Limits Test (A/m) 0.125 0.36 0.47 0.44 0.22 0.53 1.63 Remark: According KDB 680106 D01 RF Exposure Wireless Charging App v03, section 5, b). The aggregate H-field strengths at 15 cm surrounding the device and 20 cm above the top surface from all simultaneous tra…

Text truncated - open the document above for the full version.

Test Report

Page 1 of 21 Report No.: HK2006091310-1E FCC TEST REPORT Test report On Behalf of WuHan Fred Trading Co., Ltd. For 2 in 1 Wireless Charger with Watch Holder Model No.: PZOZ-WCH-001 FCC ID: 2AWPQ-PZOZWCH001 Prepared for : WuHan Fred Trading Co., Ltd. No11, 15/F, A, Huazhong International Plaza Huang Xiao He Rd, Huaqiao St, Jiangan, Wuhan, China Prepared By : Shenzhen HUAK Testing Technology Co., Ltd. 1F, B2 Building, Junfeng Zhongcheng Zhizao Innovation Park, Fuhai Street, Bao'an District, Shenzhen City, China Date of Test: Jun. 08, 2020 ~Jun. 15, 2020 Date of Report: Jun. 15, 2020 Report Number: HK2006091310-1E Page 2 of 21 Report No.: HK2006091310-1E TEST RESULT CERTIFICATION Applicant’s name ................. : WuHan Fred Trading Co., Ltd. Address ................................. : No11, 15/F, A, Huazhong International Plaza Huang Xiao He Rd, Huaqiao St, Jiangan, Wuhan, China Manufacture's Name ............ : WuHan Fred Trading Co., Ltd. Address ................................. : No11, 15/F, A, Huazhong International Plaza Huang Xiao He Rd, Huaqiao St, Jiangan, Wuhan, China Product description Trade Mark: PZOZ Product name ........................... : 2 in 1 Wireless Charger with Watch Holder Model and/or type reference : PZOZ-WCH-001 Standards ............................. : FCC Rules and Regulations Part 15 Subpart C (Section 15.209), ANSI C63.10: 2013 This publication may be reproduced in whole or in part for non-commercial purposes as long as the Shenzhen HUAK Testing Technology Co., Ltd. is acknowledged as copyright owner and source of the material. Shenzhen HUAK Testing Technology Co., Ltd. takes no responsibility for and will not assume liability for damages resulting from the reader's interpretation of the reproduced material due to its placement and context. Date of Test ............................................ : Date (s) of performance of tests ............. : Jun. 08, 2020 ~Jun. 15, 2020 Date of Issue ........................................... : Jun. 15, 2020 Test Result ............................................... : Pass Testing Engineer : (Gary Qian) Technical Manager : (Eden Hu) Authorized Signatory : (Jason Zhou) Page 3 of 21 Report No.: HK2006091310-1E Table of Contents Page 1 . TEST SUMMARY 5 1.1 TEST PROCEDURES AND RESULTS 5 1.2 TEST FACILITY 5 1.3 MEASUREMENT UNCERTAINTY 5 2. GENERAL INFORMATION 6 2.1 General Description of EUT 6 2.2. Carrier Frequency of Channels 7 2.3 Operation of EUT during testing 7 2.4 Description of Test Setup 7 2.5 Measurement Instruments List 8 3. CONDUCTED EMISSION TEST 9 3.1 Block Diagram of Test Setup 9 3.2 Conducted Power Line Emission Limit 9 3.3 Test Procedure 9 4. Occupied Bandwidth 12 4.1 Block Diagram of Test Setup 12 4.2 Rules and specifications 12 4.3 Test Procedure 12 4.4 Test Result 13 5. RADIA TED EMISSIONS 14 5.1 Block Diagram of Test Setup 14 5.2 Rules and specifications 15 5.3 Test Procedure 16 5.4 Test Result 16 6 ANTENNA REQUIREMENT 19 7. PHOTOGRAPH OF TEST 20 7.1 Radiated Emission 20 8 PHOTOS OF THE EUT 21 Page 4 of 21 Report No.: HK2006091310-1E ** Modifited History ** Revison Description Issued Data Remark Revsion 1.0 Initial Test Report Release Jun. 15, 2020 Jason Zhou Page 5 of 21 Report No.: HK2006091310-1E 1. TEST SUMMARY 1.1 TEST PROCEDURES AND RESULTS DESCRIPTION OF TEST section number RESULT CONDUCTED EMISSIONS TEST 15.207 COMPLIANT RADIATED EMISSION TEST 15.209 COMPLIANT OCCUPIED BANDWIDTH MEASUREMENT 15.215 COMPLIANT ANTENNA REQUIREMENT 15.203 COMPLIANT Note: 1. PASS: Test item meets the requirement. 2. Fail: Test item does not meet the requirement. 3. N/A: Test case does not apply to the test object. 4. The test result judgment is decided by the limit of test standard. 1.2 TEST FACILITY Test Firm : Shenzhen HUAK Testing Technology Co., Ltd. Address 1F, B2 Building, Junfeng Zhongcheng Zhizao Innovation Park, Fuhai Street, Bao'an District, Shenzhen City, China 1.3 MEASUREMENT UNCERTAINTY Measurement Uncertainty Conducted Emission Expanded Uncertainty =2.23dB, k=2 Radiated emission expanded uncertainty(9kHz-30MHz) = 3.08dB, k=2 Radiated emission expanded uncertainty(30MHz-1000MHz)= 4.42dB, k=2 Radiated emission expanded uncertainty(Above 1GHz) = 4.06dB, k=2 Page 6 of 21 Report No.: HK2006091310-1E 2. GENERAL INFORMATION 2.1 General Description of EUT Equipment 2 in 1 Wireless Charger with Watch Holder Model Name PZOZ-WCH-001 Serial No. N/A Model Difference N/A Trade Mark PZOZ FCC ID 2AWPQ-PZOZWCH001 Antenna Type Coil Antenna Antenna Gain 0dBi BT Operation frequency 125KHz Number of Channels 1 Modulation Type ASK Power Source Input:5VDC, 2A or 9VDC, 2A or 12VDC, 1.5A USB Output: 5VDC, 0.5A Wireless Output:5VDC, 1A or 9VDC, 1.2A Power Rating Input:5VDC, 2A or 9VDC, 2A or 12VDC, 1.5A USB Output: 5VDC, 0.5A Wireless Output:5VDC, 1A or 9VDC, 1.2A Page 7 of 21 Report No.: HK2006091310-1E 2.2. Carrier Frequency of Channels Operation Frequency each of channel Channel Frequency 1 125KHz 2.3 Operation of EUT during testing Operating Mode The mode is used: Transmitting mode 2.4 Description of Test Setup Operation of EUT during conducted testing and Radiation testing: AC Plug Adapter information Model: HW-059200CHQ Input: 100-240V, 50-60Hz, 0.5A Output: 5VDC, 2A Mobile phone information Model: Samsung S6 Resistance information Model: R99 Input: 50W 5Ω The sample was placed (0.8m below 1GHz, 1.5m above 1GHz) above the ground plane of 3m chamber. Measurements in both horizontal and vertical polarities were performed. During the test, each emission was maximized by: having the EUT continuously working, investigated all operating modes, rotated about all 3 axis (X, Y & Z) and considered typical configuration to obtain worst position, manipulating interconnecting cables, rotating the turntable, varying antenna height from 1m to 4m in both horizontal and vertical polarizations. The emissions worst-case are shown in Test Results of the following pages. The worst case is X position Adapter EUT Mobile phone Resistance Page …

Text truncated - open the document above for the full version.

Test Setup Photos

Conducted Emission Radiated Emissions

Contact Information

Applicant

Di Ming Li(General Manager)
[email protected]13517222444Fax: 13517222444

Technical Contact

WuHan Fred Trading Co., Ltd.
[email protected]

China

Test Firm

Shenzhen HUAK Testing Technology Co., Ltd.Jason Zhou
[email protected]+86-755-23029901

Technical Specifications

#Rule PartsFrequency RangePower Output
115C0.125 MHz - 0.125 MHz-
Confidentiality
Long Term