Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.
Page 1 of 5 Model: RCB04A Standard Thermostatic On/Off Remote Control INSTALLATION AND OPERATING INSTRUCTIONS IF YOU CANNOT READ OR UNDERSTAND THESE INSTALLATION INSTRUCTIONS DO NOT ATTEMPT TO INSTALL OR OPERATE INSTRUCTION: This wireless thermostatic on/off/ remote control system provides a safe, reliable, and user- friendly remote control for millivolt valve gas appliances. The system can be thermostatically or manually turned on and off with the transmitter. Always check the appliance home owner’s manual for additional information, or warnings regarding accessory installation before connecting this remote control system. Carefully inspect the contents for shipping damage. If any parts are missing or damaged, immediately contact the dealer from whom you purchased the kit. Do not attempt to install any part of the kit unless all parts are in good condition. Please keep these instructions for future reference. CONTENTS OF KIT Description Quantity RCB04A Thermostat remote control Transmitter 1 Installation Instructions 1 Screws (for install Transmitterl) 2 Screws Cap (for install Transmitterl) 2 Wall Clip (for install Transmitter) 1 NOTE:Due to the sensitive temperature monitoring components in the transmitter,it is necessary to allow the transmitter to stabilize to room temperature before accurate room temperature are displayed, If the transmitter is activated from a severe cold condition allow 15 minutes for accurate temperature reading to appear on the LCD. WARNING Important Safety Information Read this manual thoroughly prior to installing, programming or operating any remote control. This remote control system is designed for use with a millivolt or 24V gas valve system. Do not use this remote control system on applications with voltages above 24 Volts AC/DC and 1 amp current. This remote control Transmitter requires two (2) “AAA” alkaline batteries to power the transmitter FEATURES/SPECIFICATIONS Easy Access Thermostatic Control Low Battery Indication Child Proof Lock-out Select Between °C and °F display. 4 bits DIP Switches Select Security Codes Page 2 of 5 Transmitter: Installing Batteries: The remote transmitter uses two (2) “AAA” batteries. To install batteries: 1. Press down the battery door and remove the battery door. 2. Install uses two (2) “AAA” batteries batteries as indicated on transmitter. 3. Close the battery door by snapping in place. 4. The batteries should be replaced when the low battery indicator display in LCD. 5. When both batteries are installed, the transmitter will initialize for 1 seconds and then is ready for use. LEARNING TRANSMITTER TO RECEIVER 1. The transmitter privacy (DIP) switches are preset at the factory. Setting the 4 bits DIP Switches on transmitter to select a security code. 2. Put the receiver slide switch to “REMOTE” location. Using a small screwdriver or end of a paper clip gently press and Hold the LEARN button on the receiver to accept the transmitter security code upon initial use,When you release the LEARN button the receiver will emit an audible “beep 3. After the receiver emits the beep. press the transmitter “ON “or “OFF” button and release at once. The receiver will emit several beeps indicating that the transmitter’s code has been accepted into the receiver. 4. If you are unsuccessful in matching the security code on the first attempt repeat step 1-3 WARN ING Do not use two (2) or more remote control systems in the same area with the same dip switch settings, as they will communicate with each other. This may cause the appliances to malfunction. Dip Switch (Default) Transmitter Page 3 of 5 OPERATIONS: Transmitter: General: The RCB04A Remote Control has two (2) operating modes: Manual and Thermostatic. The control system can be set to temperature ranges between 45°F and 99°F. The transmitter will operate the remote receiver from 1 foot to 30 feet. The distance is reduced when batteries are low or when the receiver is inside a metal enclosure. Initial start up: 1. After initial power up the transmitter is reset. 2. During system reset, all features of the LCD will be visible. After one second, the LCD will be initialized. A typical reset display is shown right. After reset the transmitter is operating. The real room temperature is shown as right. Manual Mode: 1. Press the” ON” button once to turn on the appliance. 2. Press the” OFF” button once again to turn off the appliance. 3. Press” ON” and” OFF” button at same time for 1 second to select between °C and °F display. Thermostatic mode: 1. Press the ”MODE” button to enter the thermostatic mode. ROOM and TEMP icon will appear on the lower LCD screen 2. In thermostatic mode, press and hold the ”SET” button to set the desired set temperature between 45°F and 99°F. 3. Once the setting is completed, the transmitter will automatically turn on the fireplace when the room temperature is below the set temperature and turn off the appliance when the room temperature is above the set temperature within 1 degree. 4. There will be a slight delay in the response of the unit (on/off) to a temperature. Room temperature is monitored every 3 minutes. 5. Press the”ON” button or”OFF”button or”MODE”button to exit the thermostatic mode (Return to Manual Mode). The “ROOM” temp icon will disappear on the lower LCD display. The transmitter will be in the manual on/off mode Low-battery detection: 1. When the battery voltage of remote less than 2.2V, the low battery icon will appear on the LCD screen. The battery will be checked every3 minute. If the battery voltage of remote is less than 1.5V, the remote will send the flame off command to the receiver and only low battery icon display on the LCD, Change the battery before the battery is too weak for normal operation. TURN THE UNIT OFF BEFORE REPLACING BATTERIES. Child-proof protection: 1. Press and hold ”ON” and”MODE” button at same time for 5 seconds to activate child- proof mode. The letters CP will appear in the TEMP frame on the LCD screen.…
Text truncated - open the document above for the full version.
Declaration Letter We, Sunwell Technology Company Limited declared that our product Fireplace Remote Control item No.: IF-BTSS, IF-SSKT, RCB04A, RCB04B, RCB04C, RCB05A were identical inside, the electrical circuit design, layout, components used and internal wiring, with only difference being model name and for different areas. Sincerely yours Signature: Name/Title: Tim TAO / Manager Tel. No.: 86-755-84672832 E-Mail: [email protected] Date:2020-6-30
C5266091_X8_Ed.1 1/1 Letter of Authorization Sunwell Technology Company Limited Company: Sunwell Technology Company Limited Address: Building 2.Unit 2.Floor 4A. Jinlong Garden,Nanlian Community,Longgang Street,Shenzhen.China Product Name: Fireplace Remote Control Model Number: IF-BTSS;IF-SSKT;RCB04A;RCB04B;RCB04C;RCB05A FCC Identifier: 2AWRZ-IF-BTSS-TX We authorize LGAI Technological Center S.A., Ronda de la Font del Carme, s/n, 08193 Bellaterra, Spain, to act on our behalf on all matters concerning the above named equipment. Any individual within LGAI Technological Center S.A. is authorized to act on our behalf and take action on the application. We declare that authorize LGAI Technological Center S.A., Ronda de la Font del Carme, s/n, 08193 Bellaterra, Spain, is allowed to forward all information related to the approval project to the Federal Communication Commission and to discuss any issues concerning the approval application. Any and all acts carried out by LGAI Technological Center S.A. on our behalf shall have the same effect as acts of our own. Name: Tim TAO Date: 2020-6-30 Title: manager Signature of applicant:
C5266091_X10_Ed.2 1/1 Sunwell Technology Company Limited Office of Engineering Technology Federal Communications Commission 7435 Oakland Mills Road Columbia, MD 21046 Date: 2020-06-30 Subject: Request for Confidentiality FCC ID: 2AWRZ-IF-BTSS-TX To Whom It May Concern, Pursuant to the provisions of Sections 0.457 and 0.459 of Commission's rules (47CFR0.457, 0.459), we are requesting the Commission to withhold the following attachment(s) as confidential document from public disclosure. Exhibits Long-Term Confidentiality Short-Term Confidentiality NOTE 2 ID Label/Location No No Attestation Statement No No External Photos No ☐ Block Diagram ☑ ☐ Schematics ☑ ☐ Test Report No No Test Setup Photos No ☐ User’s Manual ☐ NOTE 1 No Internal Photos ☑ NOTE 1 ☐ Parts List / Tune Up ☑ ☐ RF Exposure Info No No Operational Description ☑ ☐ Cover Letter(s) No No SDR Software / Security Info No NOTE 1: Long-Term Confidentiality may be permitted under special conditions (See II. LONG-TERM CONFIDENTIALITY, Section 3 of KDB 726920, use last in force) NOTE 2: Short-Term Confidentiality can be requested for a maximum of 180 days from the date of the grant. Above mentioned document contains detailed system and equipment description are considered as proprietary information in operation of the equipment. The public disclosure of above documents might be harmful to our company and would give competitor an unfair advantage in the market. In case of short-term Confidentiality, the applicant requests the exhibits selected above are withheld from public view for a period of ___180___ days from the date of the Grant of Equipment Authorization and prior to marketing. It is our understanding that all measurement test reports, FCC ID label format and correspondent during certification review process cannot be granted as confidential documents and those information will be available for public review once the grant of equipment authorization is issued. Sincerely, Signature: Name: Tim TAO Title: Manager ☐
Report No: CCISE200601201 Shenzhen Zhongjian Nanfang Testing Co., Ltd. Project No.: CCISE2006012 No.110~116, Building B, Jinyuan Business Building, Xixiang Road, Bao’an District, Shenzhen, Guangdong, China Tel: +86-755-23118282, Fax: +86-755-23116366 Page 25 of 30 8 EUT Constructional Photos Report No: CCISE200601201 Shenzhen Zhongjian Nanfang Testing Co., Ltd. Project No.: CCISE2006012 No.110~116, Building B, Jinyuan Business Building, Xixiang Road, Bao’an District, Shenzhen, Guangdong, China Tel: +86-755-23118282, Fax: +86-755-23116366 Page 26 of 30 Report No: CCISE200601201 Shenzhen Zhongjian Nanfang Testing Co., Ltd. Project No.: CCISE2006012 No.110~116, Building B, Jinyuan Business Building, Xixiang Road, Bao’an District, Shenzhen, Guangdong, China Tel: +86-755-23118282, Fax: +86-755-23116366 Page 27 of 30
FCC ID: THIS DEVICE COMPLIES WITH PART15 OF THE FCC RULES. OPERATION OF THIS DEVICE IS SUBJECT TO THE FOLLOWING CONDITIONS: 1)THIS DEVICE MAY NOT CAUSE HARMFUL INTERFERENCE. AND 2)THIS DEVICE MUST ACCEPT ANY INTERFERENCE RECEIVED INCLUDING INTERFERENCE THAT MAY CAUSE UNDESIRED OPERATIONS MODEL NO: IF-SSKT RCB04ARCB04BRCB04CRCB05A IF-BTSS 2AWRZ-IF-BTSS-TX FCC Label LOCATION AND SIZE MODEL:RCB04A
Report No: CCISE200601201 Shenzhen Zhongjian Nanfang Testing Co., Ltd. Project No.: CCISE2006012 No.110~116, Building B, Jinyuan Business Building, Xixiang Road, Bao’an District, Shenzhen, Guangdong, China Tel: +86-755-23118282, Fax: +86-755-23116366 Page 28 of 30 Report No: CCISE200601201 Shenzhen Zhongjian Nanfang Testing Co., Ltd. Project No.: CCISE2006012 No.110~116, Building B, Jinyuan Business Building, Xixiang Road, Bao’an District, Shenzhen, Guangdong, China Tel: +86-755-23118282, Fax: +86-755-23116366 Page 29 of 30 MC96F7616A Report No: CCISE200601201 Shenzhen Zhongjian Nanfang Testing Co., Ltd. Project No.: CCISE2006012 No.110~116, Building B, Jinyuan Business Building, Xixiang Road, Bao’an District, Shenzhen, Guangdong, China Tel: +86-755-23118282, Fax: +86-755-23116366 Page 30 of 30 ------End of report------
Shenzhen Zhongjian Nanfang Testing Co., Ltd. Report No: CCISE200601201 Authorized Signature: Bruce Zhang Laboratory Manager This report details the results of the testing carried out on one sample. The results contained in this test report do not relate to other samples of the same product and does not permit the use of the CCIS product certification mark. The manufacturer should ensure that all products in series production are in conformity with the product sample detailed in this report. This report may only be reproduced and distributed in full. If the product in this report is used in any configuration other than that detailed in the report, the manufacturer must ensure the new system complies with all relevant standards. This document cannot be reproduced except in full, without prior written approval of the Company. Any unauthorized alteration, forgery or falsification of the content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law. Unless otherwise stated the results shown in this test report refer only to the sample(s) tested and such sample(s) are retained for 90 days only. 1 Cover Page FCC REPORT Applicant: Sunwell Technology Company Limited Address of Applicant: Building 2.Unit 2.Floor 4A. Jinlong Garden,Nanlian Community, Longgang Street, Longgang District, Shenzhen. China Equipment Under Test (EUT) Product Name: Fireplace Remote Control Model No.: IF-BTSS, IF-SSKT, RCB04A, RCB04B, RCB04C, RCB05A FCC ID: 2AWRZ-IF-BTSS-TX Applicable standards: FCC CFR Title 47 Part 15 Subpart C Section 15.231 Date of sample receipt: 04 Jun., 2020 Date of Test: 04 Jun., to 24 Jun., 2020 Date of report issue: 28 Jun., 2020 Test Result: PASS* * In the configuration tested, the EUT complied with the standards specified above. Report No: CCISE200601201 Shenzhen Zhongjian Nanfang Testing Co., Ltd. Project No.: CCISE2006012 No.110~116, Building B, Jinyuan Business Building, Xixiang Road, Bao’an District, Shenzhen, Guangdong, China Tel: +86-755-23118282, Fax: +86-755-23116366 Page 2 of 30 2 Version Version No. Date Description 00 28 Jun., 2020 Original Prepared By: Date: 28 Jun., 2020 Test Engineer Check By: Date: 28 Jun., 2020 Project Engineer Report No: CCISE200601201 Shenzhen Zhongjian Nanfang Testing Co., Ltd. Project No.: CCISE2006012 No.110~116, Building B, Jinyuan Business Building, Xixiang Road, Bao’an District, Shenzhen, Guangdong, China Tel: +86-755-23118282, Fax: +86-755-23116366 Page 3 of 30 3 Contents Page 1 COVER PAGE ....................................................................................................................................................... 1 2 VERSION ............................................................................................................................................................... 2 3 CONTENTS ........................................................................................................................................................... 3 4 TEST SUMMARY .................................................................................................................................................. 4 5 GENERAL INFORMATION .................................................................................................................................. 5 5.1 CLIENT INFORMATION ............................................................................................................................................ 5 5.2 GENERAL DESCRIPTION OF E.U.T. ....................................................................................................................... 5 5.3 TEST MODE ............................................................................................................................................................ 5 5.4 DESCRIPTION OF SUPPORT UNITS ........................................................................................................................ 6 5.5 MEASUREMENT UNCERTAINTY .............................................................................................................................. 6 5.6 ADDITIONS TO, DEVIATIONS, OR EXCLUSIONS FROM THE METHOD....................................................................... 6 5.7 LABORATORY FACILITY .......................................................................................................................................... 6 5.8 LABORATORY LOCATION ....................................................................................................................................... 6 5.9 TEST INSTRUMENTS LIST ....................................................................................................................................... 7 6 TEST RESULTS AND MEASUREMENT DATA ................................................................................................ 8 6.1 ANTENNA REQUIREMENT ....................................................................................................................................... 8 6.2 RADIATED EMISSION ............................................................................................................................................. 9 6.2.1 Field Strength Of The Fundamental Signal .............................................................................................. 11 6.2.2 Spurious Emissions ..................................................................................................................................... 15 6.3 20DB BANDWIDTH ............................................................................................................................................... 20 6.4 DURATION TIME ................................................................................................................................................... 22 7 TEST SETUP PHOTOS............................................................................................................…
Text truncated - open the document above for the full version.
Report No: CCISE200601201 Shenzhen Zhongjian Nanfang Testing Co., Ltd. Project No.: CCISE2006012 No.110~116, Building B, Jinyuan Business Building, Xixiang Road, Bao’an District, Shenzhen, Guangdong, China Tel: +86-755-23118282, Fax: +86-755-23116366 Page 24 of 30 7 Test Setup Photos Radiated Emission Below 1GHz Above 1GHz
Shenzhen · China
| # | Rule Parts | Frequency Range | Power Output |
|---|---|---|---|
| 1 | 15.231 | 304.03 MHz - 304.03 MHz | - |

RF REMOTE CONTROL
Equipment Class
DSC - Part 15 Security/Remote Control Transmitter