2AWS4KW2DRFID smart reader

IDEC Corporation
RFID smart reader - FCC ID 2AWS4KW2D - IDEC Corporation
Click to zoom

Application Details

Equipment Class
DXX - Part 15 Low Power Communication Device Transmitter
Date of Grant
Aug 03, 2020
Application Purpose
Original Equipment
Date of Application
Aug 03, 2020
Equipment Note
RFID smart reader
Frequency Range
13.56000000 - 13.56000000
Company
IDEC Corporation
Country
Japan

Documents & Files

Select a file to view

Users Manual

↗

Cover Letter(s)

↗
↗

External Photos

↗

ID Label/Location Info

↗

Internal Photos

↗

Test Report

↗

Test Setup Photos

↗

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

Users Manual

%  KW2D Series RFID Reader User’s Manual Preface-1KW2D Series RFID Reader User’s Manual KW9Y-B2163 Thank you for purchasing this IDEC product. Before using this product, please confirm that there are no mistakes with your order. Carefully read this manual and use this product correctly. Safety Precautions • Read the "KW2D Series User’s Manual" to ensure correct operation before starting installation, wiring, operation, maintenance, and inspection of the KW2D Series. •*GUIFFRVJQNFOUJTVTFEJOBNBOOFSOPUTQFDJGJFECZUIFNBOVGBDUVSFS UIFQSPUFDUJPOQSPWJEFECZUIFFRVJQNFOUNBZCFJNQBJSFE • All KW2D Series modules are manufactured under IDEC’s rigorous quality control system, but users must add a backup or failsafe provision to the control system when using the KW2D Series in applications where heavy damage or personal injury may be caused, in case the KW2D Series should fail. • Implement security measures, such as those for unauthorized access to this product from external devices, on the network system side. IDEC Corporation bears no responsibility for losses, damages, and/or other expenses that occur directly or indirectly as a result of unauthorized access or other security failures. • As a security measure, always use a firewall or another tool and block accessible IP addresses and ports. • In this manual, safety precautions are categorized in order of importance: Warning notices are used to emphasize that improper operation may cause severe personal injury or death. Caution notices are used where inattention might cause personal injury or damage to equipment. • This product is not designed for use in applications requiring a high degree of reliability and safety, such as applications for medical devices, nuclear power, railroads, aerospace, and automotive devices. The KW2D Series should not be used for such applications. • Turn off power to the KW2D Series before installation, removal, wiring, maintenance, and inspection of the KW2D Series. Failure to turn power off may cause damage, electrical shocks or fire hazard. If such a circuit is configured inside the KW2D Series, Failure of the KW2D Series may cause disorder of the control system, damage, or accidents. • Special expertise is required to install, wire, and operate the KW2D Series. People without such expertise must not use the KW2D Series. • Install the KW2D Series according to the instructions described in the "KW2D Series User’s Manual". Improper installation will result in falling, failure, or malfunction of the KW2D Series. • Install the KW2D Series in environments described in the "KW2D Series User’s Manual". If the KW2D Series is used in places where the KW2D Series is subjected to high-temperature, high-humidity, condensation, corrosive gases, excessive vibrations, or excessive shocks, then electrical shocks, fire hazard, or malfunction will result. • Prevent the KW2D Series from falling while moving or transporting the KW2D Series, otherwise damage or malfunction of the KW2D Series will result. • Wiring must use lead sizes that are appropriate for the applied voltage and current. • Prevent metal fragments and pieces of wire from dropping inside the KW2D Series housing. Put a cover on the KW2D Series modules during installation and wiring. Ingress of such fragments and chips may cause fire hazard, damage, or malfunction. • Use SELV power supply that is reinforced or double-insulated from MAINS without any risk of electric shock, and Limited Energy (LIM) Circuit. • Do not disassemble, repair, or modify the KW2D Series modules. There is a risk of serious accident, such as electric shock, damage, fire, and malfunction. This device complies with part 15 of FCC Rules and Innovation, Science and Economic Development Canada’s licence- exempt RSS(s). Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. Le présent appareil est conforme à la partie 15 des règles de la FCC et aux normes des CNR d’Innovation, Sciences et Développement économique Canada applicables aux appareils radio exempts de licence. L'exploitation est autorisée aux deux conditions suivantes : (1) l'appareil ne doit pas produire de brouillage, et (2) l'appareil doit accepter tout brouillage subi, même si le brouillage est susceptible d'en compromettre le fonctionnement. FCC CAUTION Changes or modifications not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment. • Electromagnetic waves are generated from the front unit, so—excluding when using tags—stay more than 5 cm away from the front unit. • When disposing of the KW2D Series, do so in accordance with national and local regulations. Warning Warning Caution Warning Warning Caution KW2D Series RFID Reader User’s ManualPreface-2 KW9Y-B2163 Note: • This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense. • Use a Category 5 or higher STP shielded cable for the LAN cable. Introduction This manual describes the functions, configuration methods, and safety precautions of the KW2D Series RFID Reader and the KW RFID Configurator configuration software. Read this manual to ensure the correct understanding of the functions and performance of the KW2D Series RFID Reader and the …

Text truncated - open the document above for the full version.

Cover Letter(s)

Letter of Authorization Date: July 7, 2020 UL Japan, Inc. 4383-326 Asama-cho, Ise-shi, Mie 516-0021 Japan FCC ID : 2AWS4KW2D Applicant : IDEC Corporation To whom it may concern: Please be advised we authorize Yukari Ito of Consumer Technology Division, UL Japan, Inc. to act on our behalf, until otherwise notified, for applications submitted for Federal Communication Commission Radio equipment applications submitted to UL Japan, Inc. We certify that we are not subject to denial of federal benefits, that includes FCC benefits, pursuant to Section 5301 of the Anti-Drug Abuse ACT of 1988, U.S.C. 862. Further, no party, as defined in 47 CFR 1.2002(b), to the application is subject to denial of federal benefits, that includes FCC benefits. The application for the subject equipment has not been submitted to another TCB for certification. Thank you for your attention to this matter. Sincerely, Lanny Schuberg IDEC Corporation

Cover Letter(s)

Request for Confidentiality Date: July 7, 2020 UL Japan, Inc. 4383-326 Asama-cho, Ise-shi, Mie 516-0021 Japan FCC ID : 2AWS4KW2D Applicant : IDEC Corporation To whom it may concern: Please be advised that the following information is to be held confidential based on the FCC rules 0.457 and 0.459: Block Diagram Theory of Operation Schematics The application contains technical information which we deem to be trade secrets and proprietary. If made public, the information might be used to the disadvantage of the applicant in the market place. Thank you for your attention to this matter. Sincerely, Lanny Schuberg IDEC Corporation

External Photos

External Photo IDEC Corporation RFID smart reader [Model: KW2D-R100Q4E, KW2D-RH100Q4E] Front Rear External Photo IDEC Corporation RFID smart reader [Model: KW2D-R100Q4E, KW2D-RH100Q4E] Top Bottom External Photo IDEC Corporation RFID smart reader [Model: KW2D-R100Q4E, KW2D-RH100Q4E] Right Left

ID Label/Location Info

7<3(.:'5+4(7. 32:(5 9'&P$ 8VH0LQƒ&:LUH /RW1R  6HHLQVWU0DQXDOIRUPRGXOHV 0D[6XUURXQGLQJ$LU )&&,'$:6.:' 0$'(,1-$3$1 ,&.:' FRSSHUFRQGXFWRURQO\ WREHXVHG 7HPSHUDWXUHƒ& 㻖㻖㻖㻖㻖㻖㻖㻖㻖㻖㻖㻖㻖㻖 ➨㻖㻖㻖㻖㻖㻖㻖㻖ྕ ⥲ົ┬ᣦᐃ ( 6$)(7<86䞉&$ 6WULSOHQJWK PP

Internal Photos

Internal Photo IDEC Corporation RFID smart reader [Model: KW2D-R100Q4E, KW2D-RH100Q4E] Internal Photo IDEC Corporation RFID smart reader [Model: KW2D-R100Q4E, KW2D-RH100Q4E] Internal Photo IDEC Corporation RFID smart reader [Model: KW2D-R100Q4E, KW2D-RH100Q4E]

Test Report

Test report No. : 13350488H-A-R1 Page : 1 of 40 Issued date : August 5, 2020 FCC ID : 2AWS4KW2D UL Japan, Inc. Ise EMC Lab. 4383-326 Asama-cho, Ise-shi, Mie-ken 516-0021 JAPAN Telephone : +81 596 24 8999 Facsimile : +81 596 24 8124 Report Cover Page - 13-EM-F0429 Issue # 17.0 RADIO TEST REPORT Test Report No. : 13350488H-A-R1 Applicant : IDEC Corporation Type of EUT : RFID smart reader Model Number of EUT : KW2D-R100Q4E Test regulation : FCC Part 15 Subpart C: 2020 FCC ID : 2AWS4KW2D Test Result : Complied (Refer to SECTION 3.2) Date of test: June 16 to July 14, 2020 Representative test engineer: Akihiko Maeda Engineer Consumer Technology Division Approved by: Shinichi Miyazono Engineer Consumer Technology Division This report contains data that are not covered by the NVLAP accreditation. There is no testing item of "Non-accreditation". 1. This test report shall not be reproduced in full or partial, without the written approval of UL Japan, Inc. 2. The results in this report apply only to the sample tested. 3. This sample tested is in compliance with the limits of the above regulation. 4. The test results in this test report are traceable to the national or international standards. 5. This test report covers Radio technical requirements. It does not cover administrative issues such as Manual or non-Radio test related Requirements. (if applicable) 6. The all test items in this test report are conducted by UL Japan, Inc. Ise EMC Lab. 7. This test report must not be used by the customer to claim product certification, approval, or endorsement by NVLAP, NIST, or any agency of the U.S. Government. 8. The information provided from the customer for this report is identified in Section 1. 9. This report is a revised version of 13350488H-A. 13350488H-A is replaced with this report. This laboratory is accredited by the NVLAP LAB CODE 200572-0, U.S.A. The tests reported herein have been performed in accordance with its terms of accreditation. *As for the range of Accreditation in NVLAP, you may refer to the WEB address, http://japan.ul.com/resources/emc_accredited/ Test report No. : 13350488H-A-R1 Page : 2 of 40 Issued date : August 5, 2020 FCC ID : 2AWS4KW2D UL Japan, Inc. Ise EMC Lab. 4383-326 Asama-cho, Ise-shi, Mie-ken 516-0021 JAPAN Telephone : +81 596 24 8999 Facsimile : +81 596 24 8124 REVISION HISTORY Original Test Report No.: 13350488H-A Revision Test report No. Date Page revised Contents - (Ori ginal) 13350488H-A August 3, 2020 - - 1 13350488H-A-R1 August 5, 2020 P.35 Addition of Local ID: MCH-04 in the Test equi pment table of APPENDIX 2. Test report No. : 13350488H-A-R1 Page : 3 of 40 Issued date : August 5, 2020 FCC ID : 2AWS4KW2D UL Japan, Inc. Ise EMC Lab. 4383-326 Asama-cho, Ise-shi, Mie-ken 516-0021 JAPAN Telephone : +81 596 24 8999 Facsimile : +81 596 24 8124 Reference: Abbreviations (Including words undescribed in this report) A2LA The American Association for Laboratory Accreditation MCS Modulation and Coding Scheme AC Alternating Current MRA Mutual Recognition Arrangement AFH Adaptive Frequency Hopping N/A Not Applicable AM Amplitude Modulation NIST National Institute of Standards and Technology Amp, AMP Amplifier NS No signal detect. ANSI American National Standards Institute NSA Normalized Site Attenuation Ant, ANT Antenna NVLAP National Voluntary Laboratory Accreditation Program AP Access Point OBW Occupied Band Width ASK Amplitude Shift Keying OFDM Orthogonal Frequency Division Multiplexing Atten., ATT Attenuator P/M Power meter AV Average PCB Printed Circuit Board BPSK Binary Phase-Shift Keying PER Packet Error Rate BR Bluetooth Basic Rate PHY Physical Layer BT Bluetooth PK Peak BT LE Bluetooth Low Energy PN Pseudo random Noise BW BandWidth PRBS Pseudo-Random Bit Sequence Cal Int Calibration Interval PSD Power Spectral Density CCK Complementary Code Keying QAM Quadrature Amplitude Modulation Ch., CH Channel QP Quasi-Peak CISPR Comite International Special des Perturbations Radioelectriques QPSK Quadri-Phase Shift Keying CW Continuous Wave RBW Resolution Band Width DBPSK Differential BPSK RDS Radio Data System DC Direct Current RE Radio Equipment D-factor Distance factor RF Radio Frequency DFS Dynamic Frequency Selection RMS Root Mean Square DQPSK Differential QPSK RSS Radio Standards Specifications DSSS Direct Sequence Spread Spectrum Rx Receiving EDR Enhanced Data Rate SA, S/A Spectrum Analyzer EIRP, e.i.r.p. Equivalent Isotropically Radiated Power SG Signal Generator EMC ElectroMagnetic Compatibility SVSWR Site-Voltage Standing Wave Ratio EMI ElectroMagnetic Interference TR Test Receiver EN European Norm Tx Transmitting ERP, e.r.p. Effective Radiated Power VBW Video BandWidth EU European Union Vert. Vertical EUT Equipment Under Test WLAN Wireless LAN Fac. Factor FCC Federal Communications Commission FHSS Frequency Hopping Spread Spectrum FM Frequency Modulation Freq. Frequency FSK Frequency Shift Keying GFSK Gaussian Frequency-Shift Keying GNSS Global Navigation Satellite System GPS Global Positioning System Hori. Horizontal ICES Interference-Causing Equipment Standard IEC International Electrotechnical Commission IEEE Institute of Electrical and Electronics Engineers IF Intermediate Frequency ILAC International Laboratory Accreditation Conference ISED Innovation, Science and Economic Development Canada ISO International Organization for Standardization JAB Japan Accreditation Board LAN Local Area Network LIMS Laboratory Information Management System Test report No. : 13350488H-A-R1 Page : 4 of 40 Issued date : August 5, 2020 FCC ID : 2AWS4KW2D UL Japan, Inc. Ise EMC Lab. 4383-326 Asama-cho, Ise-shi, Mie-ken 516-0021 JAPAN Telephone : +81 596 24 8999 Facsimile : +81 596 24 8124 CONTENTS PAGE SECTION 1: Customer information ....................................................................................................... 5 SECTION 2: Equipment under test (EUT) ............................................................................................ 5 SECTION 3: Te…

Text truncated - open the document above for the full version.

Test Setup Photos

Test report No. : 13350488H-A-R1 Page : 36 of 40 Issued date : August 5, 2020 FCC ID : 2AWS4KW2D UL Japan, Inc. Ise EMC Lab. 4383-326 Asama-cho, Ise-shi, Mie-ken 516-0021 JAPAN Telephone : +81 596 24 8999 Facsimile : +81 596 24 8124 APPENDIX 3: Photographs of test setup Conducted Emission Photo 1 Photo 2 Test report No. : 13350488H-A-R1 Page : 37 of 40 Issued date : August 5, 2020 FCC ID : 2AWS4KW2D UL Japan, Inc. Ise EMC Lab. 4383-326 Asama-cho, Ise-shi, Mie-ken 516-0021 JAPAN Telephone : +81 596 24 8999 Facsimile : +81 596 24 8124 Radiated Emission Photo 1 Photo 2 Test report No. : 13350488H-A-R1 Page : 38 of 40 Issued date : August 5, 2020 FCC ID : 2AWS4KW2D UL Japan, Inc. Ise EMC Lab. 4383-326 Asama-cho, Ise-shi, Mie-ken 516-0021 JAPAN Telephone : +81 596 24 8999 Facsimile : +81 596 24 8124 Worst Case Position Below 30 MHz Z-axis Above 30 MHz Horizontal: Y-axis / Vertical: Y-axis X-axis Y-axis Z-axis Test report No. : 13350488H-A-R1 Page : 39 of 40 Issued date : August 5, 2020 FCC ID : 2AWS4KW2D UL Japan, Inc. Ise EMC Lab. 4383-326 Asama-cho, Ise-shi, Mie-ken 516-0021 JAPAN Telephone : +81 596 24 8999 Facsimile : +81 596 24 8124 With/Without Tag With Tag Without Tag Test report No. : 13350488H-A-R1 Page : 40 of 40 Issued date : August 5, 2020 FCC ID : 2AWS4KW2D UL Japan, Inc. Ise EMC Lab. 4383-326 Asama-cho, Ise-shi, Mie-ken 516-0021 JAPAN Telephone : +81 596 24 8999 Facsimile : +81 596 24 8124 Frequency Tolerance Photo End of Report

Contact Information

Applicant

Ainei Cho(Wizard)
[email protected]+81663982513Fax: +81663982544

Technical Contact

UL Japan, Inc.Shinichi Miyazono
[email protected]81-596-24-8999

4383-326 Asama-cho, Ise-shi · Mie-ken · Japan

Test Firm

UL Japan, Inc.Masamichi Ishii
[email protected]81-596-24-8999Fax: 81-596-24-8124

Technical Specifications

#Rule PartsFrequency RangePower Output
115C13.56 MHz - 13.56 MHz-
Confidentiality
Long Term