FCCID.CO- FCC ID Database
HomeCompaniesEquipment ClassesSearch

© 2026 FCC ID Database. All rights reserved.

AboutContactData sourced from FCC public records
  1. Home/
  2. Zhejiang Zuozhou Technology Co.,Ltd./
  3. 2AWSU-ZZ-SZ306

2AWSU-ZZ-SZ306Massager Appliances(Vibration Plate)

Zhejiang Zuozhou Technology Co.,Ltd.
Massager Appliances(Vibration Plate) - FCC ID 2AWSU-ZZ-SZ306 - Zhejiang Zuozhou Technology Co.,Ltd.
Click to zoom

Application Details

Equipment Class
DTS - Digital Transmission System
Date of Grant
Jul 26, 2020
Application Purpose
Original Equipment
Date of Application
Jul 26, 2020
Equipment Note
Massager Appliances(Vibration Plate)
Frequency Range
2402.00000000 - 2480.00000000
Company
Zhejiang Zuozhou Technology Co.,Ltd.
Country
China

Documents & Files

Select a file to view

Users Manual

↗

Cover Letter(s)

↗
↗
↗

External Photos

↗

ID Label/Location Info

↗
↗

Internal Photos

↗

RF Exposure Info

↗

Test Report

↗
↗

Test Setup Photos

↗

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

Users Manual

Massager Appliances(Vibration Plate) 120V

Cover Letter(s)

ZhejiangZuozhouTechnologyCo.,Ltd. AgentAuthorization Company:ZhejiangZuozhouTechnologyCo.,Ltd. Address:5thBuilding,3rdDistrict,ChengxiLogisticsCenter,99thHuachengMiddle Road,YongkangCity,ZhejiangProvince,China ProductName:MassagerAppliances(VibrationPlate) ModelNumber(s):ZZ-SZ306,ZZ-SZ305,ZZ-SZ304 ProductDescription:MassagerAppliances(VibrationPlate) WeauthorizeMiCOMLabsInc.,575BoulderCourt,Pleasanton,California94566,USA, toactonourbehalfonallmattersconcerningthecertificationofabovenamed equipment. WedeclarethatMiCOMLabsInc.isallowedtoforwardallinformationrelatedtothe approvalandcertificationofequipmenttotheregulatoryagenciesasrequiredandto discussanyissuesconcerningtheapprovalapplication.Anyandallactscarriedoutby MiCOMLabsonourbehalfshallhavethesameeffectasactsofourown. Signature:Date:2020.07.20 Name:ChenJunqin Title:GeneralManager Company:ZhejiangZuozhouTechnologyCo.,Ltd.

Cover Letter(s)

ZhejiangZuozhouTechnologyCo.,Ltd. Date:2020-07-20 Statement ProductDescription:MassagerAppliances(VibrationPlate) Modelname:ZZ-SZ306,ZZ-SZ305,ZZ-SZ304 FCCID:2AWSU-ZZ-SZ306 Weherebystatethatthesemodelsareidenticalinpowersupplymethods,safetystructure, electricalcircuitsandkeycomponents,andjustthemodelnamingisdifferentforthemarketing requirement.Yourassistanceonthismatterishighlyappreciated. Sincerely, <Signature> NameChenJunqin TitleGeneralManager CompanyZhejiangZuozhouTechnologyCo.,Ltd.

Cover Letter(s)

ZhejiangZuozhouTechnologyCo.,Ltd. OfficeofEngineeringTechnology FederalCommunicationsCommission 7435OaklandMillsRoad Columbia,MD21046 USA Date:2020.07.20 Subject;RequestforConfidentiality FCCID:2AWSU-ZZ-SZ306 ToWhomItMayConcern, PursuanttotheprovisionsoftheCommission’srulesTitle47Sections§0.457and§0.459,we arerequestingtheCommissiontowithholdthefollowingattachment(s)asconfidential documentsfrompublicdisclosureindefinitely. Thesedocumentscontaindetailedsystemandequipmentdescriptionsandareconsideredas proprietaryinformationinoperationoftheequipment.Thepublicdisclosureofthesedocuments mightbeharmfultoourcompanyandwouldgivecompetitorsanunfairadvantageinthemarket. SchematicDiagram BlockDiagram PartsList OperationalDescription Tune-upProcedure Inadditionaltoabovementioneddocuments,inordertocomplywiththemarketingregulations inTitle47CFR§2.803andtheimportationrulesinTitle47CFR§2.1204,whileensuringthat businesssensitiveinformationremainsconfidentialuntiltheactualmarketingofnewly authorizeddevices,werequestShortTermConfidentialityofthefollowingattachment(s); ExternalPhotos TestSetupPhotos InternalPhotos UserManual For45days,pursuanttoPublicNoticeDA04-1705. OR For180dayspursuanttoKDB726920D01. Itisourunderstandingthatallmeasurementtestreports,FCCIDlabelformatand correspondenceduringthecertificationreviewprocesscannotbegrantedasconfidential documentsandthisinformationwillbeavailableforpublicreviewoncethegrantofequipment authorizationisissued. Sincerely, Signature: Name:ChenJunqin Title:GeneralManager

External Photos

ExternalPhotographs

ID Label/Location Info

LabelLocation Size:70*40mm

ID Label/Location Info

Size:70*40mm ProductName:MassagerAppliances(VibrationPlate) Model:ZZ-SZ306 FCCID:2AWSU-ZZ-SZ306 Input:AC120V/60Hz;MaxPower:200W

Internal Photos

InternalPhotographs RFAntenna

RF Exposure Info

(( KSIGN® KSIGN (Gua ngdong) Testi ng C o ., Lt d . ‘叭/estSide of 1 /F., Building C, Zone A, Fuyuan New Factory, Jiujiu Industrial Park, -Minzhu,Shatou, Shajing, Bao ’ an District, Shenzhen, Guangdon� , People ’ s Republic of China Tel.· + (86)755-29852678 Fax: + (86)755-29852397巳mail:info@旦dks1gn.cnWebsite: www.gdksign.com REQUIREMENT RF Exposure Evaluation FCC ID: 2AWSU-ZZ-SZ306 KDB447498 001 General RF Exposure Guidance v06, Clause 4.3.1 (a) [ ( max. power of channel, including tune-up tolerance,mW ) I ( min. test separation distance , 『n m) ] · [ -v'f(GHz)]三3.0 Where -f(GHz) is the RF channel transmit frequency in GHz -Power and distance are rounded to the nea『est mW and mm before calculation ”The test exclusions a『e applicable only when the minimum test separation distance is :s 50 mm, and for transmission frequencies between 100 MHz and 6 GHz. When the minimum test separation distance is < 5 mm, a distance of 5 mm according to 4.1 f) is applied to determine SAR test exclusion. TEST RESULT 因Passed 口Not Applicable BT5.0 Channel Max. Max. Maximum Tune up Frequency Measure d Tune up Outpu | }白’白『 . .. · ;:, I L i m i t I R e s u l t s Power tolerance Power Power ( M Hz) (dB m ) ( d B m ) ( d Bm) ( mW ) Test mode 2402 1.01 1.01士1 2.01 1.589 GFSK 2440 0.45 0.45±1 1.45 1.396 2480 -0.30- 0.30±1 0.70 1.175 Note: -The maximum antenna gain is OdBi -The exposure safety distance is less than 5mm. ****材********柑******THE E ND**柑*********材灿***** KSIGN(Guangdong) Testing Co., Ltd.

Test Report

(( KSIEiN ® KSIGN (Guangdong) Testi ng Co., Ltd. ‘West Side of 1/F., Building C, Zone A, Fuyuan New Facto「y, Jiujiu Industrial Park, 一Minzhu,Shatou,Shajing, Bao ’ an District, Shenzhen, Guangdong, Pe。pie ’ s Republic of China Tel.: + (86)755-29852678 Fax: + (86)755-29852397 E-mail: [email protected] Website: www.gdksign.com TEST REPORT Report No ........................................ : KS2006S00194E FC C I D··...........................· • ••• ···· : 2AWSU-ZZ-SZ306 Applicant ......................................... : Zhejiang Zu。zhouTechnol。gy Co.,Ltd. Address ............................ : 5th Building, 3rd District, Chengxi Logistics Center, 99th Huacheng Middle Road, Yongkang City, Zh叫iangProvince, China Manufacturer .................................... : Zhejiang Zuozhou Technology Co.,Ltd. Address ............................................ : 5th Building, 3rd District, Chengxi Logistics Center, 99th Huacheng Middle Road, Yongkang City, Zhejiang Province, China Factory ...........”.............................. : Zhejiang Zuozhou Technology Co.,Ltd. Address ............................................. : 5th Building, 3rd District, Chengxi Logistics Center, 99th Huacheng Middle Road, Yongkang City, Zhejiang Province, China Product Name ................................. : Massager Appliances(Vibrati。n Plate) Trade Mark. Model/Type reference ...................... : ZZ-SZ306 Listed Model(s) ................................. : ZZ-SZ305, ZZ-SZ304 Standard .......................................... : F C C CFR Title 47 Part 15 Subpart C Section 15.247 Date of Receipt ......··‘................... Jun. 16,2020 Date of Test Date ....‘..................... Jun. 17, 2020圄Jul. 10, 2020 Date of issue ..... .. .... .. . .. .. •. . ....... .. .. .. ... . Jul. 10, 2020 Test result ....................................... : Pass Compiled by: (Printed name+signature) Supervised by: ( Printed name+signature) Approved by: ( Printed name+signature) Testing Laborat。可Name........... Address .... Emiya Lin Kelly Cheng Cary Luo KS I GN(Guangdong) Testing c。.,Ltd. West Side of 1/F., Building C, Zone A, Fuyuan New Factory, Jiujiu Industrial Park, Minzhu,Shatou, Shajing, Bao'an Dist「ict, Shenzhen, Guangdong, People ’ s Republic of China This test report may be duplicated completely for legal use with the approval of the applicant. It should not be rep「oducedexcept in full, without the written approval of our laboratory. The client should not use it to claim p「oductendorsement by KSIGN. The test results in the report only apply to the tested sample. The test report shall be invalid without all the signatures of testing enginee「s, reviewer and approver. Any objections must be 「aisedto KSIGN within 15 days since the date when the report is received. It will not be taken into consideration beyond this limit. The test report merely co「respondto the test sample. Page 2 of 43 ReportNo.:KS2006S00194E KSIGN(Guangdong)TestingCo.,Ltd. TABLEOFCONTENTSPage 1.TESTSUMMARY ....................................................................................................................................................................... 3 1.1. TESTSTANDARDS ................................................................................................................................................................... 3 1.2.REPORTVERSION ................................................................................................................................................................... 3 1.3.TESTDESCRIPTION ................................................................................................................................................................. 4 1.4.TESTFACILITY .................................................................................................................................................................. 5 1.5.MEASUREMENTUNCERTAINTY ................................................................................................................................................. 6 1.6.ENVIRONMENTALCONDITIONS ................................................................................................................................................. 6 2.GENERALINFORMATION ......................................................................................................................................................... 7 2.1. CLIENTINFORMATION ............................................................................................................................................................ 7 2.2.GENERALDESCRIPTIONOFEUT ............................................................................................................................................... 7 2.3.OPERATIONSTATE .................................................................................................................................................................. 8 2.4. MEASUREMENTINSTRUMENTSLIST ........................................................................................................................................... 9 2.5.TESTSOFTWARE ..................................................................................................................................................................... 9 3.TESTITEMANDRESULTS ........................................................................................................................................................ 10 3.1. ANTENNAREQUIREMENT ....................................................................................................................................................... 10 3.2. CONDUCTEDEMISSION ......................................................................................................................................................... 11 3.3.BANDEDGEANDSPURIOUSEMISSION(CONDUCTED) ..................................................................................................…

Text truncated - open the document above for the full version.

Test Report

Page 29 of 43 ReportNo.:KS2006S00194E KSIGN(Guangdong)TestingCo.,Ltd. TestVoltage:AC120V/60Hz Ant.Pol.Horizontal TestMode:TXBLEMode2480MHz EmissionLevel=ReadLevel+CorrectFactor Page 30 of 43 ReportNo.:KS2006S00194E KSIGN(Guangdong)TestingCo.,Ltd. TestVoltage:AC120V/60Hz Ant.Pol.Vertical TestMode:TXBLEMode2480MHz EmissionLevel=ReadLevel+CorrectFactor Page 31 of 43 ReportNo.:KS2006S00194E KSIGN(Guangdong)TestingCo.,Ltd. 3.8.SpuriousEmission(Radiated) Limit RadiatedEmissionLimits(9kHz~1000MHz) Frequency (MHz) FieldStrength (microvolt/meter) MeasurementDistance (meters) 0.009~0.4902400/F(KHz)300 0.490~1.70524000/F(KHz)30 1.705~30.03030 30~881003 88~2161503 216~9602003 Above9605003 RadiatedEmissionLimit(Above1000MHz) Frequency (MHz) DistanceMeters(at3m) PeakAverage Above10007454 Note: (1)Thetighterlimitappliesatthebandedges. (2)EmissionLevel(dBuV/m)=20logEmissionLevel(uV/m). TestConfiguration Below30MHzTestSetup Page 32 of 43 ReportNo.:KS2006S00194E KSIGN(Guangdong)TestingCo.,Ltd. Below1000MHzTestSetup Below1000MHzTestSetup Above1GHzTestSetup TestProcedure 1.TheEUTwassetupandtestedaccordingtoANSIC63.10:2013 2.TheEUTisplacedonaturntablewhichis0.8meterabovegroundforbelow1GHz,and1.5mforabove1 GHz.Theturntableisrotated360degreestodeterminethepositionofthemaximumemissionlevel. 3.TheEUTwasset3metersfromthereceivingantenna,whichwasmountedonthetopofavariableheight antennatower. 4.Foreachsuspectedemission,theEUTwasarrangedtoitsworstcaseandthentunetheAntennatower (from1mto4m)andturntable(from0degreeto360degrees)tofindthemaximumreading.Apre-amp andahighpassfilterareusedforthetestinordertogetbettersignalleveltocomplywiththeguidelines. 5.SettothemaximumpowersettingandenabletheEUTtransmitcontinuously. 6.Usethefollowingspectrumanalyzersettings (1)Spanshallwideenoughtofullycapturetheemissionbeingmeasured; (2)Below1GHz: RBW=120kHz,VBW=300kHz,Sweep=auto,Detectorfunction=peak,Trace=maxhold; IftheemissionleveloftheEUTmeasuredbythepeakdetectoris3dBlowerthantheapplicablelimit,the peakemissionlevelwillbereported.Otherwise,theemissionmeasurementwillberepeatedusingthe quasi-peakdetectorandreported. (3)From1GHzto10 th harmonic: RBW=1MHz,VBW=3MHzPeakdetectorforPeakvalue. RBW=1MHz,VBW=10HzRMSdetectorforAveragevalue. Page 33 of 43 ReportNo.:KS2006S00194E KSIGN(Guangdong)TestingCo.,Ltd. TestMode Pleaserefertotheclause2.3. TestResult 9KHz~30MHzand18GHz~25GHz From9KHz~30MHzand18GHz~25GHz:Conclusion:PASS Note: 1)Measurement=Readinglevel+CorrectFactor CorrectFactor=AntennaFactor+CableLoss-PreamplifierFactor 2)Thepeaklevelislowerthanaveragelimit(54dBuV/m),thisdataisthetooweakinstrumentofsignalis unabletotest. 3)Theemissionlevelsofotherfrequenciesareverylowerthanthelimitandnotshowintestreport. 4)Theamplitudeofspuriousemissionswhichareattenuatedbymorethan20dBbelowthepermissiblevalue hasnoneedtobereported. 5)Pre-scanCH00,CH19andCH39modulation,andfoundtheCH00whichitisworsecasefor30MHz-1GHz, soonlyshowthetestdataforworsecase. Page 34 of 43 ReportNo.:KS2006S00194E KSIGN(Guangdong)TestingCo.,Ltd. 30MHz-1GHz TestVoltage:AC120V/60Hz Ant.Pol.Horizontal TestMode:TX2402MHz EmissionLevel=ReadLevel+CorrectFactor Page 35 of 43 ReportNo.:KS2006S00194E KSIGN(Guangdong)TestingCo.,Ltd. TestVoltage:AC120V/60Hz Ant.Pol.Vertical TestMode:TX2402MHz EmissionLevel=ReadLevel+CorrectFactor Page 36 of 43 ReportNo.:KS2006S00194E KSIGN(Guangdong)TestingCo.,Ltd. Adobe1GHz TestVoltage:AC120V/60Hz Ant.Pol.Horizontal TestMode:TXBLEMode2402MHz Remark:Noreportfortheemissionwhichmorethan10dBbelowthe prescribedlimit. EmissionLevel=ReadLevel+CorrectFactor Page 37 of 43 ReportNo.:KS2006S00194E KSIGN(Guangdong)TestingCo.,Ltd. TestVoltage:AC120V/60Hz Ant.Pol.Vertical TestMode:TXBLEMode2402MHz Remark:Noreportfortheemissionwhichmorethan10dBbelowthe prescribedlimit. EmissionLevel=ReadLevel+CorrectFactor Page 38 of 43 ReportNo.:KS2006S00194E KSIGN(Guangdong)TestingCo.,Ltd. TestVoltage:AC120V/60Hz Ant.Pol.Horizontal TestMode:TXBLEMode2440MHz Remark:Noreportfortheemissionwhichmorethan10dBbelowthe prescribedlimit. EmissionLevel=ReadLevel+CorrectFactor Page 39 of 43 ReportNo.:KS2006S00194E KSIGN(Guangdong)TestingCo.,Ltd. TestVoltage:AC120V/60Hz Ant.Pol.Vertical TestMode:TXBLEMode2440MHz Remark:Noreportfortheemissionwhichmorethan10dBbelowthe prescribedlimit. EmissionLevel=ReadLevel+CorrectFactor Page 40 of 43 ReportNo.:KS2006S00194E KSIGN(Guangdong)TestingCo.,Ltd. TestVoltage:AC120V/60Hz Ant.Pol.Horizontal TestMode:TXBLEMode2480MHz Remark:Noreportfortheemissionwhichmorethan10dBbelowthe prescribedlimit. EmissionLevel=ReadLevel+CorrectFactor Page 41 of 43 ReportNo.:KS2006S00194E KSIGN(Guangdong)TestingCo.,Ltd. TestVoltage:AC120V/60Hz Ant.Pol.Vertical TestMode:TXBLEMode2480MHz Remark:Noreportfortheemissionwhichmorethan10dBbelowthe prescribedlimit. EmissionLevel=ReadLevel+CorrectFactor Page 42 of 43 ReportNo.:KS2006S00194E KSIGN(Guangdong)TestingCo.,Ltd. 4.EUTTESTPHOTOS ReferencetothedocumentNo.:TestPhotos. Page 43 of 43 ReportNo.:KS2006S00194E KSIGN(Guangdong)TestingCo.,Ltd. 5.PHOTOGRAPHSOFEUTCONSTRUCTIONAL ReferencetothedocumentNo.:ExternalPhotosandInternalPhotos. ******THEEND******

Test Setup Photos

FCCID:2AWSU-ZZ-SZ306 RadiatedEmissions (30MHz~1000MHz) RadiatedEmissions (Above1GHz) RFConducted ConductedEmissionForACMainsPowerPorts

Contact Information

Applicant

Chen Junqin(General Manager)
[email protected]13857951222Fax: 0579-87145588

Technical Contact

Zhejiang Zuozhou Technology Co.,Ltd.
[email protected]

China

Test Firm

KSIGN (Guangdong) Testing Co., Ltd.Neil Wan
[email protected]86 0755 2985 2678

Technical Specifications

#Rule PartsFrequency RangePower Output
115C2.40 GHz - 2.48 GHz1.26 mW
Confidentiality
Long Term
Grant Notes
Output power listed is conducted power.

Other Applications from Zhejiang Zuozhou Technology Co.,Ltd.

Massager Appliances(Vibration Plate) - FCC ID 2AWSU-ZZ-SZ314 - Zhejiang Zuozhou Technology Co.,Ltd.
2AWSU-ZZ-SZ314

Massager Appliances(Vibration Plate)

Aug 26, 2024

Equipment Class

DSS - Part 15 Spread Spectrum Transmitter