Application Details

Equipment Class
DTS - Digital Transmission System
Date of Grant
Dec 23, 2020
Application Purpose
Original Equipment
Date of Application
Dec 23, 2020
Equipment Note
router
Frequency Range
2422.00000000 - 2452.00000000
Company
Guangdong Xintengda Communication Technology Co.,Ltd.
Country
China

Documents & Files

Select a file to view

Users Manual

↗

Attestation Statements

↗

Cover Letter(s)

↗
↗

External Photos

↗

ID Label/Location Info

↗

Internal Photos

↗

RF Exposure Info

↗

Test Report

↗
↗
↗
↗

Test Setup Photos

↗

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

Users Manual

MK600UserManual UserManual/V1.0 2 Copyright Statement XTD is the registered trademark of Guangdong Xin teng da Communication Technolgy Co., Ltd. Other trademark or trade name mentioned herein are the trademark or registered trademark of the company. Copyright of the whole product as integration, including its accessories and software, belongs to Guangdong Xin teng da Communication Technolgy Co., Ltd. Without the permission of Guangdong Xin teng da Communication Technolgy Co., Ltd. individual or party is not allowed to copy, plagiarize, imitate or translate it into other languages. All the photos and product specifications mentioned in this manual are for references only, as the upgrading of software and hardware, there will be changes. And if there are changes, XTD is not responsible for informing in advance. If you want to know more information about our products, please connect us. FCC ID:2AWTP-MK600 This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. changes or modifications not expressly approved by the party responsible for compliance could void the user's authority to operate the equipment. NOTE: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures: -- Reorient or relocate the receiving antenna. -- Increase the separation between the equipment and receiver. -- Connect the equipment into an outlet on a circuit different 3 from that to which the receiver is connected. -- Consult the dealer or an experienced radio/TV technician for help. The distance between user and products should be no less than 20cm i TableofContents 4GCPERouter CONTENTS Chapter1:Introduction ..................................................................... 1 ProductOverview ............................................................................... 1 MainFeatures ..................................................................................... 3 Chapter2QuickuseguideInstallation .......................................... 4 Firststep: ........................................................................................................... 4 Secondstep: ...................................................................................................... 4 Threesetp: ........................................................................................................ 5 Chapter3Detailedsettingdescription .......................................... 6 ConfiguretheComputer’sIPAddress ............................................... 6 Routerstatusview ............................................................................ 12 ChangeWi-Fipassword .................................................................... 15 ModifyLANSetting .......................................................................... 15 ModifyWANSetting ......................................................................... 17 ModifyFirewallSetting .................................................................... 18 ModifyAdministratorSetting .......................................................... 19 ViewSystemLOGfile ....................................................................... 21 4GCPERouter 1 Chapter1:Introduction Chapter1:Introduction ProductOverview Mk600isaWiFiwirelessindoorCPEdesignedforhomecompanyapplications.Itconformsto IEEE802.11b/g/nstandardandhasthecharacteristicsofhightransmissionrateandhigh receivingsensitivity.Theshelladoptsenvironmentalprotectionintegratedmoldingdesign,which notonlycanpreventdust,butalsocanfullyadapttovariousworkingenvironments. FrontPanel 4GCPERouter 2 Chapter1:Introduction PowerLED:ThePowerLEDlightsupwhentheRouterispoweredon. SYSLED:TheSYSLEDlightsupwhenthesystemisrun.ItflasheswhensystemrunOK. WLANLED:TheWirelessLEDlightsupwhenthewirelessfeatureisenabled.Itflasheswhenthe Routersendsorreceivesdataoverthewirelessnetwork. LAN(1~4):TheseLEDsarecorrespondingwiththeLANportsontherearpanel.TheLEDis continuouslylitwhentheRouterisconnectedtoadevicethroughthatport.Itflashestoindicate networkactivityoverthatport. SignalLED:The4GSignalLEDlightsupwhenthe4GSignalOK.4Gsignalindicatorindicates4G signalstrength· Itisredwhenthesignalisweak,purplewhenthesignalismedium,andbluewhenthesignalis strong 4GLED:The4GLEDlightsupwhen4Gisonline.Flashingwhen4Gdialing. WhentheRoutergoesthroughitsself-diagnosticmodeduringeveryboot-up,theLEDflashes. Whenthediagnosticiscomplete,theLEDiscontinuouslylit. LEDStatusDescription POWER OnPowerison OffPowerisoff SYSBlinkingSystemisok WLANOn Thewirelessfunctionisenabled 4G CPE Router 3 Chapter 1: Introduction OffThe wireless function is disabled BlinkingSending or receiving data over wireless network LAN (Port 1-4) OnLAN port is connected OffLAN port is unconnected BlinkingData is transmitting Signal LED RedSignal is weak PurpleSignal is medium BlueSignal is strong 4G LED Blinking4G is dialing ON4G is online Main Features 1.2.4GHz 1T1R 300mbps technology is adopted to meet multi-user connection application; 2.Minipcie interface and SIM card slot are provided to support the expansion of built-in 3G / 4G applications; 3.Support 4 100…

Text truncated - open the document above for the full version.

Attestation Statements

Declaration of difference We Guangdong Xintengda Communication Technology Co.,Ltd. , declare that all models: MK600, MK700, MK700, MK800, MK900 are electrically identical ,Only the models and colors are different. Signature: Company: Guangdong Xintengda Communication Technology Co.,Ltd.

Cover Letter(s)

DATE 2020/11 /27 Equipme nt Autorisation Division Federal Communications Commission 7 435 Oakland Mills Road Columbia, MD 21046 FCC ID: 2AWTP-MK600 Product Name: router Request for Confidentiality Pursuant to Sections 0.457 and 0.459 of the commissions rules, we hereby request that the following documents be held confidential: (List here the documents for which you are seeking confidentiality - for example ... ) • Schematics • Block diagram • Operation description These materials contain trade secrets and proprietary information and are not customarily released to the public. The public disclosure of this information might be harmful to the company and provide unjustified benefits to our competitors. <Signature> Name Cao Ning Title Manager Applicant Company Guangdong Xintengda Communication Technology Co .• Ltd.

External Photos

Model No.: MK600

ID Label/Location Info

40mm 20mm Model:MK600 FCC ID: 2AWTP-MK600 Contains FCC ID:XMR201808EC25AF

Internal Photos

Model No.: MK600

RF Exposure Info

Page 1 of 2 Product Name: router Model No.:MK600, MK700, MK800, MK900 FCC ID:2AWTP-MK600 RF Exposure Evaluation 1.1 RF Exposure Compliance Requirement 1.1.1 Limits A ccording to FCC Part1.1310: The criteria listed in the following table shall be used to evaluate the environment impact of human exposure to radio frequency (RF) radiation as specified in part1.1307(b) F= Frequency in MHz Friis Formula Friis transmission formula: Pd = (Pout*G)/(4* Pi * R 2) Where Pd = power density in mW/cm2 Pout = output power to antenna in mW G = gain of antenna in linear scale Pi = 3.1416 R = distance between observation point and center of the radiator in cm Pd id the limit of MPE, 1 mW/cm2 . If we know the maximum gain of the antenna and the total power input to the antenna, through the calculation, we will know the distance r where the MPE limit is reached. 1.1.2 Test Procedure Software provided by client enabled the EUT to transmit and receive data at lowest, middle and highest channel individually. 1.1.3 EUT RF Exposure Evaluation Antenna Gain: 4dBi Antenna Gain: The maximum Gain measured in fully anechoic chamber is 2.512 in linear scale. Output Power Into Antenna & RF Exposure Evaluation Distance: Channel Frequency (MHz) Max Conducted Output Power (dBm) Output Power to Antenna (mW) Power Density at R = 20 cm (mW/cm 2 ) Limit Result Highest 2462 17.11 51.40 0.026 1.0 PASS Note: The distance for calculate is 20 cm Page 2 of 2

Test Report

Page 1 of134 BlueAsia of Technical Services(Shenzhen) Co., Ltd. Add:No. 448, Bulong Road, Bantian Street, Longgang District, Shenzhen, China Tel: +86-755-23059481 Email: [email protected] www.cblueasia.com TEST REPORT Product Name: router Brand Mark: NBKEY Model No.: MK600 , MK700, MK800, MK900 FCC ID: 2AWTP-MK600 Report Number: BLA-EMC-202010-A1601 Date of Sample Receipt : 2020/10/13 Date of Test: 2020/10/13 to 2020/11/18 Date of Issue : 2020/11/18 Test Standard: 47 CFR Part 15, Subpart C 15.247 Test Result:Pass Prepared for: Guangdong Xintengda Communication Technology Co.,Ltd. 3rd Floor,No.256,Mingyue 2 Road,Luangang Village,Shiwan Town,Boluo County,Huizhou City,Guangdong Province Prepared by: BlueAsia of Technical Services(Shenzhen) Co.,Ltd. IOT Test Centre of BlueAsia No. 448 Bulong Road, Bantian Street, Longgang District, Shenzhen,China TEL: +86-755-23059481 Compiled by:Review by: Approved by:Date: 2020/11/18 Report No.: BLA-EMC-202010-A1601 Page 2 of134 BlueAsia of Technical Services(Shenzhen) Co., Ltd. Tel: +86-755-23059481 Email: [email protected] www.cblueasia.com REPORT REVISE RECORD Version No.DateDescription 002020/11/18Original Report No.: BLA-EMC-202010-A1601 Page 3 of134 BlueAsia of Technical Services(Shenzhen) Co., Ltd. Tel: +86-755-23059481 Email: [email protected] www.cblueasia.com TABLE OF CONTENTS 1 TEST SUMMARY ........................................................................................................................................6 2 GENERAL INFORMATION .........................................................................................................................7 3 GENERAL DESCRIPTION OF E.U.T. .........................................................................................................7 4 TEST ENVIRONMENT ................................................................................................................................8 5 TEST MODE ................................................................................................................................................8 6 MEASUREMENT UNCERTAINTY ..............................................................................................................8 7 DESCRIPTION OF SUPPORT UNIT...........................................................................................................9 8 LABORATORY LOCATION .........................................................................................................................9 9 TEST INSTRUMENTS LIST ..................................................................................................................... 10 RADIATED SPURIOUS EMISSIONS ............................................................................................................... 13 LIMITS ............................................................................................................................................................................. 13 BLOCK DIAGRAM OF TEST SETUP .................................................................................................................................... 14 PROCEDURE ................................................................................................................................................................... 14 TEST DATA ........................................................................................................................................................................ 16 RADIATED EMISSIONS WHICH FALL IN THE RESTRICTED BANDS ......................................................... 42 LIMITS ............................................................................................................................................................................. 42 BLOCK DIAGRAM OF TEST SETUP .................................................................................................................................... 43 PROCEDURE ................................................................................................................................................................... 43 TEST DATA ........................................................................................................................................................................ 45 CONDUCTED SPURIOUS EMISSIONS ........................................................................................................... 74 LIMITS ............................................................................................................................................................................. 74 BLOCK DIAGRAM OF TEST SETUP .................................................................................................................................... 74 TEST DATA ........................................................................................................................................................................ 75 CONDUCTED BAND EDGES MEASUREMENT ............................................................................................. 76 LIMITS ............................................................................................................................................................................. 76 BLOCK DIAGRAM OF TEST SETUP .................................................................................................................................... 76 TEST DATA ........................................................................................................................................................................ 77 MINIMUM 6DB BANDWIDTH ........................................................................................................................... 78 LIMITS ............................................................................................................................................................................. …

Text truncated - open the document above for the full version.

Test Report

Report No.: BLA-EMC-202010-A1601 Page 46 of134 BlueAsia of Technical Services(Shenzhen) Co., Ltd. Tel: +86-755-23059481 Email: [email protected] www.cblueasia.com [TestMode: TX]; [Polarity: Vertical] Test Result: Pass Report No.: BLA-EMC-202010-A1601 Page 47 of134 BlueAsia of Technical Services(Shenzhen) Co., Ltd. Tel: +86-755-23059481 Email: [email protected] www.cblueasia.com AVG Value: [TestMode: TX]; [Polarity: Vertical] Test Result: Pass Report No.: BLA-EMC-202010-A1601 Page 48 of134 BlueAsia of Technical Services(Shenzhen) Co., Ltd. Tel: +86-755-23059481 Email: [email protected] www.cblueasia.com Highest channel [TestMode: TX]; [Polarity: Horizontal] Test Result: Pass Report No.: BLA-EMC-202010-A1601 Page 49 of134 BlueAsia of Technical Services(Shenzhen) Co., Ltd. Tel: +86-755-23059481 Email: [email protected] www.cblueasia.com [TestMode: TX]; [Polarity: Vertical] Test Result: Pass Report No.: BLA-EMC-202010-A1601 Page 50 of134 BlueAsia of Technical Services(Shenzhen) Co., Ltd. Tel: +86-755-23059481 Email: [email protected] www.cblueasia.com 802.11g: lowest channel [TestMode: TX]; [Polarity: Horizontal] Test Result: Pass Report No.: BLA-EMC-202010-A1601 Page 51 of134 BlueAsia of Technical Services(Shenzhen) Co., Ltd. Tel: +86-755-23059481 Email: [email protected] www.cblueasia.com [TestMode: TX]; [Polarity: Horizontal] Test Result: Pass Report No.: BLA-EMC-202010-A1601 Page 52 of134 BlueAsia of Technical Services(Shenzhen) Co., Ltd. Tel: +86-755-23059481 Email: [email protected] www.cblueasia.com [TestMode: TX]; [Polarity: Vertical] Test Result: Pass Report No.: BLA-EMC-202010-A1601 Page 53 of134 BlueAsia of Technical Services(Shenzhen) Co., Ltd. Tel: +86-755-23059481 Email: [email protected] www.cblueasia.com [TestMode: TX]; [Polarity: Vertical] Test Result: Pass Report No.: BLA-EMC-202010-A1601 Page 54 of134 BlueAsia of Technical Services(Shenzhen) Co., Ltd. Tel: +86-755-23059481 Email: [email protected] www.cblueasia.com Highest channel: [TestMode: TX]; [Polarity: Horizontal] Test Result: Pass Report No.: BLA-EMC-202010-A1601 Page 55 of134 BlueAsia of Technical Services(Shenzhen) Co., Ltd. Tel: +86-755-23059481 Email: [email protected] www.cblueasia.com [TestMode: TX]; [Polarity: Horizontal] Test Result: Pass Report No.: BLA-EMC-202010-A1601 Page 56 of134 BlueAsia of Technical Services(Shenzhen) Co., Ltd. Tel: +86-755-23059481 Email: [email protected] www.cblueasia.com [TestMode: TX]; [Polarity: Vertical] Test Result: Pass Report No.: BLA-EMC-202010-A1601 Page 57 of134 BlueAsia of Technical Services(Shenzhen) Co., Ltd. Tel: +86-755-23059481 Email: [email protected] www.cblueasia.com [TestMode: TX]; [Polarity: Vertical] Test Result: Pass Report No.: BLA-EMC-202010-A1601 Page 58 of134 BlueAsia of Technical Services(Shenzhen) Co., Ltd. Tel: +86-755-23059481 Email: [email protected] www.cblueasia.com 802.11n20: lowest channel [TestMode: TX]; [Polarity: Horizontal] Test Result: Pass Report No.: BLA-EMC-202010-A1601 Page 59 of134 BlueAsia of Technical Services(Shenzhen) Co., Ltd. Tel: +86-755-23059481 Email: [email protected] www.cblueasia.com [TestMode: TX]; [Polarity: Horizontal] Test Result: Pass Report No.: BLA-EMC-202010-A1601 Page 60 of134 BlueAsia of Technical Services(Shenzhen) Co., Ltd. Tel: +86-755-23059481 Email: [email protected] www.cblueasia.com [TestMode: TX]; [Polarity: Vertical] Test Result: Pass Report No.: BLA-EMC-202010-A1601 Page 61 of134 BlueAsia of Technical Services(Shenzhen) Co., Ltd. Tel: +86-755-23059481 Email: [email protected] www.cblueasia.com [TestMode: TX]; [Polarity: Vertical] Test Result: Pass Report No.: BLA-EMC-202010-A1601 Page 62 of134 BlueAsia of Technical Services(Shenzhen) Co., Ltd. Tel: +86-755-23059481 Email: [email protected] www.cblueasia.com Highest channel: [TestMode: TX]; [Polarity: Horizontal] Test Result: Pass Report No.: BLA-EMC-202010-A1601 Page 63 of134 BlueAsia of Technical Services(Shenzhen) Co., Ltd. Tel: +86-755-23059481 Email: [email protected] www.cblueasia.com [TestMode: TX]; [Polarity: Horizontal] Test Result: Pass Report No.: BLA-EMC-202010-A1601 Page 64 of134 BlueAsia of Technical Services(Shenzhen) Co., Ltd. Tel: +86-755-23059481 Email: [email protected] www.cblueasia.com [TestMode: TX]; [Polarity: Vertical] Test Result: Pass Report No.: BLA-EMC-202010-A1601 Page 65 of134 BlueAsia of Technical Services(Shenzhen) Co., Ltd. Tel: +86-755-23059481 Email: [email protected] www.cblueasia.com [TestMode: TX]; [Polarity: Vertical] Test Result: Pass Report No.: BLA-EMC-202010-A1601 Page 66 of134 BlueAsia of Technical Services(Shenzhen) Co., Ltd. Tel: +86-755-23059481 Email: [email protected] www.cblueasia.com 802.11n40: lowest channel [TestMode: TX]; [Polarity: Vertical] Test Result: Pass Report No.: BLA-EMC-202010-A1601 Page 67 of134 BlueAsia of Technical Services(Shenzhen) Co., Ltd. Tel: +86-755-23059481 Email: [email protected] www.cblueasia.com [TestMode: TX]; [Polarity: Vertical] Test Result: Pass Report No.: BLA-EMC-202010-A1601 Page 68 of134 BlueAsia of Technical Services(Shenzhen) Co., Ltd. Tel: +86-755-23059481 Email: [email protected] www.cblueasia.com [TestMode: TX]; [Polarity: Horizontal] Test Result: Pass Report No.: BLA-EMC-202010-A1601 Page 69 of134 BlueAsia of Technical Services(Shenzhen) Co., Ltd. Tel: +86-755-23059481 Email: [email protected] www.cblueasia.com [TestMode: TX]; [Polarity: Horizontal] Test Result: Pass Report No.: BLA-EMC-202010-A1601 Page 70 of134 BlueAsia of Technical Services(Shenzhen) Co., Ltd. Tel: +86-755-23059481 Email: [email protected] www.cblueasia.com Highest channel: [TestMode: TX]; [Polarity: Horizontal] Test Result: Pass Report No.: BLA-EMC-202010-A1601 Page 71 of134 BlueAsia of Technical Services(Shenzhen) Co., Ltd. Tel: +86-755-23059481 Email: [email protected] www.cblueasia.com [TestMode: TX]; [Polarity: Horizontal] Test Result: P…

Text truncated - open the document above for the full version.

Test Report

Report No.: BLA-EMC-202010-A1601 Page 86 of134 BlueAsia of Technical Services(Shenzhen) Co., Ltd. Tel: +86-755-23059481 Email: [email protected] www.cblueasia.com ANTENNA REQUIREMENT Test Standard 47 CFR Part 15, Subpart C 15.247 Test Method N/A CONCLUSION Standard Requirement: An intentional radiator shall be designed to ensure that no antenna other than that furnished by the responsible party shall be used with the device. The use of a antenna that uses a unique coupling to the intentional radiator, the manufacturer may design the unit permanently attached antenna or of an so that a broken antenna can be replaced by the user, but the use of a standard antenna jack or electrical connector is prohibited. EUT Antenna: The antenna is integrated on the main PCB and no consideration of replacement. The best case gain of the antenna is 4.0dBi. Report No.: BLA-EMC-202010-A1601 Page 87 of134 BlueAsia of Technical Services(Shenzhen) Co., Ltd. Tel: +86-755-23059481 Email: [email protected] www.cblueasia.com 10 APPENDIX Appendix1 10.1 APPENDIXA: DTS BANDWIDTH Test Result TestMode Antenna Channel DTS BW [MHz] FL[MHz] FH[MHz] Limit[MHz] Verdict 11B Ant1 2412 9.640 2407.480 2417.120 >=0.5 PASS 2437 9.400 2432.440 2441.840 >=0.5 PASS 2462 9.640 2457.480 2467.120 >=0.5 PASS 11G Ant1 2412 13.880 2405.680 2419.560 >=0.5 PASS 2437 13.880 2430.680 2444.560 >=0.5 PASS 2462 10.120 2456.960 2467.080 >=0.5 PASS 11N20SISO Ant1 2412 15.160 2404.520 2419.680 >=0.5 PASS 2437 10.920 2430.720 2441.640 >=0.5 PASS 2462 12.960 2456.640 2469.600 >=0.5 PASS 11N40SISO Ant1 2422 30.160 2406.960 2437.120 >=0.5 PASS 2437 34.000 2420.680 2454.680 >=0.5 PASS 2452 30.320 2435.680 2466.000 >=0.5 PASS Report No.: BLA-EMC-202010-A1601 Page 88 of134 BlueAsia of Technical Services(Shenzhen) Co., Ltd. Tel: +86-755-23059481 Email: [email protected] www.cblueasia.com Test Graphs 11B_Ant1_2412 11B_Ant1_2437 11B_Ant1_2462 11G_Ant1_2412 Report No.: BLA-EMC-202010-A1601 Page 89 of134 BlueAsia of Technical Services(Shenzhen) Co., Ltd. Tel: +86-755-23059481 Email: [email protected] www.cblueasia.com 11G_Ant1_2437 11G_Ant1_2462 11N20SISO_Ant1_2412 Report No.: BLA-EMC-202010-A1601 Page 90 of134 BlueAsia of Technical Services(Shenzhen) Co., Ltd. Tel: +86-755-23059481 Email: [email protected] www.cblueasia.com 11N20SISO_Ant1_2437 11N20SISO_Ant1_2462 11N40SISO_Ant1_2422 Report No.: BLA-EMC-202010-A1601 Page 91 of134 BlueAsia of Technical Services(Shenzhen) Co., Ltd. Tel: +86-755-23059481 Email: [email protected] www.cblueasia.com 11N40SISO_Ant1_2437 11N40SISO_Ant1_2452 Report No.: BLA-EMC-202010-A1601 Page 92 of134 BlueAsia of Technical Services(Shenzhen) Co., Ltd. Tel: +86-755-23059481 Email: [email protected] www.cblueasia.com 10.2 APPENDIXB: OCCUPIED CHANNEL BANDWIDTH Test Result TestMode Antenna Channel OCB [MHz] FL[MHz] FH[MHz] Limit[MHz] Verdict 11B Ant1 2412 14.346 2404.971 2419.317 --- PASS 2437 14.453 2429.922 2444.375 --- PASS 2462 14.352 2454.927 2469.279 --- PASS 11G Ant1 2412 16.768 2403.739 2420.507 --- PASS 2437 16.783 2428.726 2445.509 --- PASS 2462 16.748 2453.688 2470.436 --- PASS 11N20SISO Ant1 2412 17.703 2403.204 2420.907 --- PASS 2437 17.699 2428.207 2445.906 --- PASS 2462 17.717 2453.204 2470.921 --- PASS 11N40SISO Ant1 2422 35.886 2404.127 2440.013 --- PASS 2437 36.082 2419.029 2455.111 --- PASS 2452 35.919 2434.142 2470.061 --- PASS Report No.: BLA-EMC-202010-A1601 Page 93 of134 BlueAsia of Technical Services(Shenzhen) Co., Ltd. Tel: +86-755-23059481 Email: [email protected] www.cblueasia.com Test Graphs 11B_Ant1_2412 11B_Ant1_2437 11B_Ant1_2462 11G_Ant1_2412 Report No.: BLA-EMC-202010-A1601 Page 94 of134 BlueAsia of Technical Services(Shenzhen) Co., Ltd. Tel: +86-755-23059481 Email: [email protected] www.cblueasia.com 11G_Ant1_2437 11G_Ant1_2462 11N20SISO_Ant1_2412 Report No.: BLA-EMC-202010-A1601 Page 95 of134 BlueAsia of Technical Services(Shenzhen) Co., Ltd. Tel: +86-755-23059481 Email: [email protected] www.cblueasia.com 11N20SISO_Ant1_2437 11N20SISO_Ant1_2462 11N40SISO_Ant1_2422 Report No.: BLA-EMC-202010-A1601 Page 96 of134 BlueAsia of Technical Services(Shenzhen) Co., Ltd. Tel: +86-755-23059481 Email: [email protected] www.cblueasia.com 11N40SISO_Ant1_2437 11N40SISO_Ant1_2452 Report No.: BLA-EMC-202010-A1601 Page 97 of134 BlueAsia of Technical Services(Shenzhen) Co., Ltd. Tel: +86-755-23059481 Email: [email protected] www.cblueasia.com 10.3 APPENDIXC: MAXIMUM CONDUCTED OUTPUT POWER Test Result TestMode Antenna Channel Result[dBm] Limit[dBm] Verdict 11B Ant1 2412 15.67 <=30 PASS 2437 15.98 <=30 PASS 2462 17.11 <=30 PASS 11G Ant1 2412 14.47 <=30 PASS 2437 14.51 <=30 PASS 2462 15.36 <=30 PASS 11N20SISO Ant1 2412 14.11 <=30 PASS 2437 13.85 <=30 PASS 2462 15.35 <=30 PASS 11N40SISO Ant1 2422 14.65 <=30 PASS 2437 14.05 <=30 PASS 2452 14.04 <=30 PASS Report No.: BLA-EMC-202010-A1601 Page 98 of134 BlueAsia of Technical Services(Shenzhen) Co., Ltd. Tel: +86-755-23059481 Email: [email protected] www.cblueasia.com Test Graphs 11B_Ant1_2412 11B_Ant1_2437 11B_Ant1_2462 Report No.: BLA-EMC-202010-A1601 Page 99 of134 BlueAsia of Technical Services(Shenzhen) Co., Ltd. Tel: +86-755-23059481 Email: [email protected] www.cblueasia.com 11G_Ant1_2412 11G_Ant1_2437 11G_Ant1_2462 Report No.: BLA-EMC-202010-A1601 Page 100 of134 BlueAsia of Technical Services(Shenzhen) Co., Ltd. Tel: +86-755-23059481 Email: [email protected] www.cblueasia.com 11N20SISO_Ant1_2412 11N20SISO_Ant1_2437 11N20SISO_Ant1_2462 Report No.: BLA-EMC-202010-A1601 Page 101 of134 BlueAsia of Technical Services(Shenzhen) Co., Ltd. Tel: +86-755-23059481 Email: [email protected] www.cblueasia.com 11N40SISO_Ant1_2422 11N40SISO_Ant1_2437 11N40SISO_Ant1_2452 Report No.: BLA-EMC-202010-A1601 Page 102 of134 BlueAsia of Technical Services(Shenzhen) Co., Ltd. Tel: +86-755-23059481 Email: [email protected] www.cblueasia.com Report No.: BLA-EMC-202010-A1601 Page 103 of134 BlueAsia o…

Text truncated - open the document above for the full version.

Test Report

Report No.: BLA-EMC-202010-A1601 Page 108 of134 BlueAsia of Technical Services(Shenzhen) Co., Ltd. Tel: +86-755-23059481 Email: [email protected] www.cblueasia.com Report No.: BLA-EMC-202010-A1601 Page 109 of134 BlueAsia of Technical Services(Shenzhen) Co., Ltd. Tel: +86-755-23059481 Email: [email protected] www.cblueasia.com 10.5 APPENDIXE:BAND EDGE MEASUREMENTS Test Result TestMode Antenna ChName Channel RefLevel[dBm] Result[dBm] Limit[dBm] Verdict 11B Ant1 Low 2412 11.36 -45.03 <=-18.64 PASS High 2462 7.45 -51.08 <=-22.55 PASS 11G Ant1 Low 2412 4.02 -49.4 <=-25.98 PASS High 2462 6.78 -49.46 <=-23.22 PASS 11N20SISO Ant1 Low 2412 5.59 -46.6 <=-24.41 PASS High 2462 6.41 -48.8 <=-23.59 PASS 11N40SISO Ant1 Low 2422 3.00 -38.35 <=-27.01 PASS High 2452 2.38 -44.04 <=-27.62 PASS Report No.: BLA-EMC-202010-A1601 Page 110 of134 BlueAsia of Technical Services(Shenzhen) Co., Ltd. Tel: +86-755-23059481 Email: [email protected] www.cblueasia.com Test Graphs 11B_Ant1_Low_2412 11B_Ant1_High_2462 11G_Ant1_Low_2412 11G_Ant1_High_2462 Report No.: BLA-EMC-202010-A1601 Page 111 of134 BlueAsia of Technical Services(Shenzhen) Co., Ltd. Tel: +86-755-23059481 Email: [email protected] www.cblueasia.com 11N20SISO_Ant1_Low_2412 11N20SISO_Ant1_High_2462 11N40SISO_Ant1_Low_2422 Report No.: BLA-EMC-202010-A1601 Page 112 of134 BlueAsia of Technical Services(Shenzhen) Co., Ltd. Tel: +86-755-23059481 Email: [email protected] www.cblueasia.com 11N40SISO_Ant1_High_2452 Report No.: BLA-EMC-202010-A1601 Page 113 of134 BlueAsia of Technical Services(Shenzhen) Co., Ltd. Tel: +86-755-23059481 Email: [email protected] www.cblueasia.com 10.6 APPENDIXF:CONDUCTED SPURIOUSEMISSION Test Result TestMode Antenna Channel FreqRange [Mhz] RefLevel [dBm] Result [dBm] Limit [dBm] Verdict 11BAnt1 2412 Reference 6.35 6.35 --- PASS 30~100030~1000-55.163<=-23.65 PASS 1000~26500 1000~26500 -46.095<=-23.65 PASS 2437 Reference 6.24 6.24 --- PASS 30~1000 30~1000 -55.15<=-23.76 PASS 1000~26500 1000~26500 -49.285<=-23.76 PASS 2462 Reference7.247.24---PASS 30~1000 30~1000 -55.941<=-22.76 PASS 1000~26500 1000~26500 -53.163<=-22.76 PASS 11GAnt1 2412 Reference 3.26 3.26 --- PASS 30~1000 30~1000 -53.777<=-26.74 PASS 1000~265001000~26500-50.327<=-26.74 PASS 2437 Reference 4.61 4.61 --- PASS 30~100030~1000-53.972<=-25.39PASS 1000~26500 1000~26500 -52.751<=-25.39 PASS 2462 Reference 4.32 4.32 --- PASS 30~100030~1000-54.534<=-25.68PASS 1000~26500 1000~26500 -53.854<=-25.68 PASS 11N20SISOAnt1 2412 Reference4.854.85---PASS 30~1000 30~1000 -53.955<=-25.15 PASS 1000~26500 1000~26500 -50.924<=-25.15 PASS 2437 Reference 4.86 4.86 --- PASS 30~1000 30~1000 -53.731<=-25.14 PASS 1000~265001000~26500-51.091<=-25.14PASS 2462 Reference 5.49 5.49 --- PASS 30~1000 30~1000 -54.728<=-24.51 PASS 1000~26500 1000~26500 -52.94<=-24.51 PASS 11N40SISOAnt1 2422 Reference 2.18 2.18 --- PASS 30~100030~1000-51.73<=-27.82PASS 1000~26500 1000~26500 -53.076<=-27.82 PASS 2437 Reference 3.03 3.03 --- PASS 30~1000 30~1000 -51.899<=-26.97 PASS 1000~26500 1000~26500 -53.342<=-26.97 PASS 2452 Reference2.302.30---PASS 30~1000 30~1000 -52.55<=-27.7 PASS 1000~265001000~26500-53.453<=-27.7PASS Report No.: BLA-EMC-202010-A1601 Page 114 of134 BlueAsia of Technical Services(Shenzhen) Co., Ltd. Tel: +86-755-23059481 Email: [email protected] www.cblueasia.com …

Text truncated - open the document above for the full version.

Contact Information

Applicant

Cao Ning(Manager)
[email protected]+86 0752-6832636Fax: N/A

Test Firm

BlueAsia of Technical Services (Shenzhen)Blue Zheng
[email protected]+86 755-23059481-815

Technical Specifications

#Rule PartsFrequency RangePower Output
215C2.42 GHz - 2.45 GHz29.17 mW
Confidentiality
Long Term
Grant Notes
Power output listed is conducted. This device has a 20 MHz and 40 MHz bandwidth mode.The antenna(s) used for this transmitter must be installed to provide a separation distance of at least 20 cm from all persons and must not be co-located or operating in conjunction with any other transmitter. End-users and installers must be provided with antenna installation instructions and transmitter operating conditions for satisfying RF exposure compliance.

Other Applications from Guangdong Xintengda Communication Technology Co.,Ltd.

WIFI REPEATER - FCC ID 2AWTP-KP300 - Guangdong Xintengda Communication Technology Co.,Ltd.
2AWTP-KP300

WIFI REPEATER

Jul 08, 2020

Equipment Class

DTS - Digital Transmission System