FCCID.CO- FCC ID Database
HomeCompaniesEquipment ClassesSearch

© 2026 FCC ID Database. All rights reserved.

AboutContactData sourced from FCC public records
  1. Home/
  2. IoTEC Co., Ltd./
  3. 2AWWO-PWF-500

2AWWO-PWF-500Petmom water

IoTEC Co., Ltd.
Petmom water - FCC ID 2AWWO-PWF-500 - IoTEC Co., Ltd.
Click to zoom

Application Details

Equipment Class
DCD - Part 15 Low Power Transmitter Below 1705 kHz
Date of Grant
Jul 18, 2020
Application Purpose
Original Equipment
Date of Application
Jul 18, 2020
Equipment Note
Petmom water
Frequency Range
0.11100000 - 0.20500000
Company
IoTEC Co., Ltd.
Country
South Korea

Documents & Files

Select a file to view

Users Manual

↗

Cover Letter(s)

↗
↗

External Photos

↗

ID Label/Location Info

↗

Internal Photos

↗

RF Exposure Info

↗

Test Report

↗

Test Setup Photos

↗

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

Users Manual

영문 영문 영문 영문 영문 영문 영문 영문 FCC Information to User This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one of the following measures: •Reorient or relocate the receiving antenna. •Increase the separation between the equipment and receiver. •Connect the equipment into an outlet on a circuit different from that to which the receiver is con-nected. •Consult the dealer or an experienced radio/TV technician for help. Caution Modifications not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment. FCC Compliance Information : This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. IMPORTANT NOTE: FCC RF Radiation Exposure Statement: This equipment should be installed and operated with a minimum distance of 20 centimeters between the radiator and your body. This transmitter must not be co- located or operating in conjunction with any other antenna or transmitter. 영문

Cover Letter(s)

<IoTEC Co., Ltd.> Office of Engineering Technology Federal Communications Commission 7435 Oakland Mills Road Columbia, MD 21046 Date: July 16, 2020 Subject; Request for Confidentiality FCC ID: 2AWWO-PWF-500 To Whom It May Concern, Pursuant to the provisions of Sections 0.457 and 0.459 of Commission's rules (47CFR0.457, 0.459), we are requesting the Commission to withhold the following attachment(s) as confidential document from public disclosure indefinitely. • Schematic Diagram • Block Diagram • Part List • Operational Description Above mentioned document contains detailed system and equipment description are considered as proprietary information in operation of the equipment. The public disclosure of above documents might be harmful to our company and would give competitor an unfair advantage in the market. In additional to above mentioned documents, pursuant to Public Notice DA 04-1705 of the Commission' s policy, in order to comply with the marketing regulations in 47 CFT §2.803 and the importation rules in 47 CFR §2.1204, while ensuring that business sensitive information remains confidential until the actual marketing of newly authorized devices. We are requesting the commission to grant shot-term confidentiality request on the following attachment(s) for 180 days after the grant as outlined in Public Notice DA 04-1705. • External Photos • Internal Photos • Test Setup Photos • User Manual It is our understanding that all measurement test reports, FCC ID label format and correspondent during certification review process cannot be granted as confidential documents and those information will be available for public review once the grant of equipment authorization is issued. Sincerely, Signature: Name: GO JAE SOO Title: CEO

Cover Letter(s)

IoTEC Co., Ltd. Letter of Authorization Company: IoTEC Co., Ltd. Address: 802, MARIO tower 28, Digital-ro 30-gil, Guro-gu. Seouk Korea Product Name: Petmom water Model Number: PWF-500 FCC Identifier: 2AWWO-PWF-500 We authorize MiCOM Labs Inc, 575 Boulder Court, Pleasanton, California 94566, USA, to act on our behalf on all matters concerning the above named equipment. Any individual within MiCOM Labs is authorized to act on our behalf and take action on the application. We declare that MiCOM Labs Inc, 575 Boulder Court, Pleasanton, California 94566, USA, is allowed to forward all information related to the approval project to the Federal Communication Commission and to discuss any issues concerning the approval application. Any and all acts carried out by MiCOM Labs on our behalf shall have the same effect as acts of our own. Name: GO JAE SOO Date: July 16, 2020 Title: CEO Signature of applicant:

ID Label/Location Info

Page 1 of 1 IDENTIFICATION LABEL: PROPOSED FCC ID LABEL The FCC ID shall be permanently affixed in the rear side of the equipment Authorized Person - Print Name: GO JAE SOO Date: July 16, 2020 Signature: This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operations. Made in Korea FCC ID : 2AWWO-PWF-500

RF Exposure Info

Page 1 of 23 Report No. : OT-207-RWD-006 It should not be reproduced except in full, without the written approval of ONETECH Corp. EMC-003 (Rev.2) ONETECH Corp.: 43-14, Jinsaegol-gil, Chowol-eup, Gwangju-si, Gyeonggi-do, 12735, Korea (TEL: 82-31-799-9500, FAX: 82-31-799-9599) RF PERFORMANCE TEST REPORT Test Report No. : OT-207-RWD-006 AGR No : A19DA-098 Applicant : IoTEC Co., Ltd. Address : 802, MARIO tower 28, Digital-ro 30-gil, Guro-gu. Seouk Korea Manufacturer : IoTEC Co., Ltd. Address : 802, MARIO tower 28, Digital-ro 30-gil, Guro-gu. Seouk Korea Type of Equipment : Petmom water FCC ID. : 2AWWO-PWF-500 Model Name : PWF-500 Multiple Model Name : N/A Serial number : N/A Total page of Report : 23 pages (including this page) Date of Incoming : December 11, 2019 Date of issue : July 09, 2020 SUMMARY The equipment complies with the regulation; FCC CFR47 Part 15 Subpart C Section 15.207 and 15.209 This test report only contains the result of a single test of the sample supplied for the examination. It is not a generally valid assessment of the features of the respective products of the mass-production. Reviewed by: Approved by: Ha-Ram Lee / Manager Ki-Hong, Nam / General Manager ONETECH Corp. ONETECH Corp. Page 2 of 23 Report No. : OT-207-RWD-006 It should not be reproduced except in full, without the written approval of ONETECH Corp. EMC-003 (Rev.2) ONETECH Corp.: 43-14, Jinsaegol-gil, Chowol-eup, Gwangju-si, Gyeonggi-do, 12735, Korea (TEL: 82-31-799-9500, FAX: 82-31-799-9599) CONTENTS PAGE 1. VERIFICATION OF COMPLIANCE ............................................................................................. 5 2. TEST SUMMARY .............................................................................................................................. 6 2.1 TEST ITEMS AND RESULTS ............................................................................................................................................. 6 2.2 ADDITIONS, DEVIATIONS, EXCLUSIONS FROM STANDARDS ........................................................................................... 6 2.3 RELATED SUBMITTAL(S) / GRANT(S) ............................................................................................................................ 6 2.4 PURPOSE OF THE TEST ................................................................................................................................................... 6 2.5 TEST METHODOLOGY .................................................................................................................................................... 6 2.6 TEST FACILITY ............................................................................................................................................................... 6 3. GENERAL INFORMATION ............................................................................................................ 7 3.1 PRODUCT DESCRIPTION ................................................................................................................................................. 7 3.2 ALTERNATIVE TYPE(S)/MODEL(S); ALSO COVERED BY THIS TEST REPORT. ................................................................ 7 4. EUT MODIFICATIONS .................................................................................................................... 7 5. SYSTEM TEST CONFIGURATION ............................................................................................... 8 5.1 JUSTIFICATION ............................................................................................................................................................... 8 5.2 PERIPHERAL EQUIPMENT .............................................................................................................................................. 8 5.3 MODE OF OPERATION DURING THE TEST ...................................................................................................................... 8 5.4 CONFIGURATION OF TEST SYSTEM ............................................................................................................................... 9 5.5 ANTENNA REQUIREMENT .............................................................................................................................................. 9 6. PRELIMINARY TEST .................................................................................................................... 10 6.1 AC POWER LINE CONDUCTED EMISSIONS TESTS ....................................................................................................... 10 6.2 GENERAL RADIATED EMISSIONS TESTS ..................................................................................................................... 10 7. 20 DB BANDWIDTH ....................................................................................................................... 11 7.1 OPERATING ENVIRONMENT ......................................................................................................................................... 11 7.2 TEST SET-UP ................................................................................................................................................................. 11 7.3 TEST DATA .................................................................................................................................................................... 12 8. SPURIOUS EMISSION TEST ........................................................................................................ 13 8.1 REGULATION ................................................................................................................................................................ 13 8.2 TEST SET-UP ................................................................................................................................................................. 13 8.3 TEST DATA FOR USING MAX LOAD (1 000 MA) …

Text truncated - open the document above for the full version.

Test Report

Page 1 of 10 Report No.: OT-207-RWD-005 It should not be reproduced except in full, without the written approval of ONETECH Corp. EMC-003 (Rev.2) ONETECH Corp.: 43-14, Jinsaegol-gil, Chowol-eup, Gwangju-si, Gyeonggi-do, 12735, Korea (TEL: 82-31-799-9500, FAX: 82-31-799-9599) EMF TEST REPORT Test Report No. : OT-207-RWD-005 AGR No. : A19DA-098 Applicant : IoTEC Co., Ltd. Address : 802, MARIO tower 28, Digital-ro 30-gil, Guro-gu. Seoul Korea Manufacturer : IoTEC Co., Ltd. Address :802, MARIO tower 28, Digital-ro 30-gil, Guro-gu. Seoul Korea Type of Equipment : Petmom water FCC ID. : 2AWWO-PWF-500 Model Name : PWF-500 Multiple Model Name : N/A Serial number : N/A Total page of Report : 10 pages (including this page) Date of Incoming : December 11, 2019 Date of issue : July 09, 2020 SUMMARY The equipment complies with the regulation; FCC CFR 47 PART 1.1310 This test report only contains the result of a single test of the sample supplied for the examination. It is not a generally valid assessment of the features of the respective products of the mass-production. Reviewed by: Approved by: Ha-Ram Lee / Manager Ki-Hong, Nam / General Manager ONETECH Corp. ONETECH Corp. Page 2 of 10 Report No.: OT-207-RWD-005 It should not be reproduced except in full, without the written approval of ONETECH Corp. EMC-003 (Rev.2) ONETECH Corp.: 43-14, Jinsaegol-gil, Chowol-eup, Gwangju-si, Gyeonggi-do, 12735, Korea (TEL: 82-31-799-9500, FAX: 82-31-799-9599) CONTENTS PAGE 1. VERIFICATION OF COMPLIANCE ............................................................................................. 4 2. GENERAL INFORMATION ............................................................................................................ 5 2.1 PRODUCT DESCRIPTION ................................................................................................................................................. 5 2.2 ALTERNATIVE TYPE(S)/MODEL(S); ALSO COVERED BY THIS TEST REPORT. ................................................................ 5 3. EUT MODIFICATIONS .................................................................................................................... 5 4. RADIO FREQUENCY EXPOSURE ................................................................................................ 6 4.1 ENVIRONMENTAL EVALUATION AND EXPOSURE LIMIT ................................................................................................ 6 4.2 E / H FIELD STRENGTH ................................................................................................................................................... 8 4.2.1 EUT Operating condition ....................................................................................................................................8 4.2.2 EUT Operating condition ....................................................................................................................................8 4.2.3 Measurement procedure .......................................................................................................................................8 4.2.4 E - field strength .................................................................................................................................................9 4.2.5 H - field strength .................................................................................................................................................9 4.3 LIST OF TEST EQUIPMENT ................................................................................................................................... 10 Page 3 of 10 Report No.: OT-207-RWD-005 It should not be reproduced except in full, without the written approval of ONETECH Corp. EMC-003 (Rev.2) ONETECH Corp.: 43-14, Jinsaegol-gil, Chowol-eup, Gwangju-si, Gyeonggi-do, 12735, Korea (TEL: 82-31-799-9500, FAX: 82-31-799-9599) Revision History Issue Report No. Issued Date Revisions Effect Section OT-207-RWD-005 July 09, 2020 Initial Release All Page 4 of 10 Report No.: OT-207-RWD-005 It should not be reproduced except in full, without the written approval of ONETECH Corp. EMC-003 (Rev.2) ONETECH Corp.: 43-14, Jinsaegol-gil, Chowol-eup, Gwangju-si, Gyeonggi-do, 12735, Korea (TEL: 82-31-799-9500, FAX: 82-31-799-9599) 1. VERIFICATION OF COMPLIANCE Applicant : IoTEC Co., Ltd. Address : 802, MARIO tower 28, Digital-ro 30-gil, Guro-gu. Seoul Korea Contact Person : GO JAE SOO / CEO Telephone No. : +82-2-6672-0400 FCC ID : 2AWWO-PWF-500 Model Name : PWF-500 Serial Number : N/A Date : July 09, 2020 EQUIPMENT CLASS DCD – Part 15 Low Power Transmitter Below 1 705 kHz KIND OF EQUIPMENT Petmom water THIS REPORT CONCERNS Original Grant MEASUREMENT PROCEDURES ANSI C63.10: 2013 TYPE OF EQUIPMENT TESTED Pre-Production KIND OF EQUIPMENT AUTHORIZATION REQUESTED Certification EQUIPMENT WILL BE OPERATED UNDER FCC RULES PART(S) FCC CFR 47 PART 1.1310 MODIFICATIONS ON THE EQUIPMENT TO ACHIEVE COMPLIANCE No FINAL TEST WAS CONDUCTED ON 3 m, Semi Anechoic Chamber -. The above equipment was tested by ONETECH Corp. for compliance with the requirement set forth in the FCC Rules and Regulations. This said equipment in the configuration described in this report, shows the maximum emission levels emanating from equipment are within the compliance requirements. Page 5 of 10 Report No.: OT-207-RWD-005 It should not be reproduced except in full, without the written approval of ONETECH Corp. EMC-003 (Rev.2) ONETECH Corp.: 43-14, Jinsaegol-gil, Chowol-eup, Gwangju-si, Gyeonggi-do, 12735, Korea (TEL: 82-31-799-9500, FAX: 82-31-799-9599) 2. GENERAL INFORMATION 2.1 Product Description The IoTEC Co., Ltd., Model: PWF-500 (referred to as the EUT in this report) is an Petmom water. Product specification information described herein was obtained from product data sheet or user’s manual. DEVICE TYPE Wireless Charger OPERATING FREQUENCY 111 kHz ~ 205 kHz RATED RF OUTPUT POWER 80.4 dBμV/m ANTENNA TYPE Coil Antenna MODULATION ASK RA…

Text truncated - open the document above for the full version.

Test Setup Photos

Page 1 of 6 - Conducted Emission Test Page 2 of 6 - Radiated Emission Test (9 kHz ~ 30 MHz) Page 3 of 6 - Radiated Emission Test (30 MHz ~ 1 GHz) Page 4 of 6 - EMF Test Portion A Portion B Page 5 of 6 Portion C Portion D Page 6 of 6 Portion E Portion F

Contact Information

Applicant

JAE SOO GO(CEO)
[email protected]82-2-6672-0400Fax: 82-2-6673-0430

Technical Contact

IoTEC Co., Ltd.
[email protected]

South Korea

Test Firm

ONETECH Corp.Ki Hong Nam
[email protected]82-31-799-9580Fax: 82-31-799-9599

Technical Specifications

#Rule PartsFrequency RangePower Output
115C0.111 MHz - 0.205 MHz-
Confidentiality
Long Term