Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.
POWER PACK Wireless Charging Function: When the external power supply is plugged in to charge the product, the wireless charging function will start automatically. When there is no external power supply, put phone on the wireless charging device, press the button to begin wireless charging, then press the button again to complete wireless charging when finished. Power Display Function: Press button once to display the current power level. Port Charging Function: Device can be charged via type-c cable included in box. Model Number: PB02 Battery Capacity: 10000 mAh (34WhA) Battery Type: Lithium Type-C Power Input: 5V 2A (Max) USB-A Power Output: 5V2.1A (Max) Wireless Charger Power Output: 5V1A USB-A Power Export Type-C Power Input Button Wireless Charge Area Power Percentage W arning: Read all instructions and warnings prior to using this product. Improper use of this product may result in product damage, excess heat, toxic fumes, fire or explosion, for which damages you (“purchaser”), and not Planet Beyond (“Manufacturer”) are responsible. • Do not store battery in high temperature environments, including intense sunlight or heat. Do not place battery in fire or other excessively hot environments. • Be cautious of excessive drops, bumps, abrasions or other impacts to this battery. If there is any damage to the battery such as dents, punctures, tears, deformities or corrosion, due to any cause, discontinue use and contact manufacturer or dispose of in an appropriate manner. • Do not disassemble this battery or attempt to repair or modify it in any manner. • Do not expose this battery to moisture or submerge it in liquid. Keep battery dry at all times. • Do not attempt to charge battery using any other method, apparatus or connection other than the device’s USB connector. For questions or instructions for the various ways to charge, refer to the product’s User Manual. • Do not attempt to replace any part of this battery. • If this battery is intended by purchaser to be used by a minor, purchasing adult agrees to provide detailed instructions and warnings to any minor prior to use. Failure to do so is sole responsibility of purchaser, who agrees to identify manufacturer for any unintended use or misuse by a minor. • All batteries have gone through a thorough quality assurance inspection. If you find that your battery is excessively hot, is emitting odor, is deformed, has abrasions, cuts or is experiencing or demonstrating an abnormal phenomenon, immediately stop all battery use and contact manufacturer. • For extended storage, first charge your battery for one hour. • Never dispose of batteries in the garbage. Disposal of batteries in the garbage is unlawful under state and federal environmental laws and regulations. Always take used batteries to your local battery-recycling center. Legal: This Battery is meant for use only in conjunction with the appropriate mobile entertainment device. Please consult your device packaging to determine whether this battery is compatible with your particular mobile entertainment device. Manufacturer is not responsible for any damages to any mobile entertainment device incurred through the use of this product. Manufacturer shall not in any way be liable to you or to any third party for any damages you or any third party may suffer as a result of use, intended or unintended, or misuse of this Battery in conjunction with any device or accessory other than the appropriate mobile entertainment device for which this battery is designed. Manufacturer will not be responsible for any damages you or any third party may suffer as a result of misuse of this Battery as outlined above. If you are responsible for battery use with an unintended mobile entertainment device and damages result from such use, you agree to indemnify Manufacturer for any resulting injuries to any third part(ies). FCC Statement: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures: -- Increase the separation between the equipment and receiver. -- Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. -- Consult an experienced radio/TV technician for help. This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) This device must accept any interference received, including interference that may cause undesired operation. Caution: changes or modifications not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment. This equipment complies with FCC radiation exposure limits set forth for an uncontrolled environment. This transmitter must not be co-located or operating in conjunction with any other antenna or transmitter. FCC ID: 2AX2J-PB02 The distance between user and products should be no less than 20cm
November 12, 2020 Federal Communications Commission Authorization & Evaluation Division 7345 Oakland Mills Road Columbia, Maryland 21046 Authority to Act as Agent On our behalf, I appoint Shenzhen Timeway Testing Laboratories/ Zone C, 1st Floor, Block B, Jun Xiang Da Building, Zhongshan Park Road West, Tong Le Village, Nanshan District, Shenzhen, China. (Name of Agent company name and address) to act as our agent in the preparation of this application for equipment certification. I certify that submitted documents properly describe the device or system for which equipment certification is sought. I also certify that each unit manufactured, imported or marketed, as defined in the Federal Communications Commission’s regulations will have affixed to it a label identical to that submitted for approval with this application. For instances where our authorized agent signs the application for certification on our behalf, I acknowledge that all responsibility for complying with the terms and conditions for certification, still resides with Planet Beyond LLC / 31 Hudson Yards, NEW YORK, NY 10001, United States <Signature> NameChristian Melvin TitleCo-Founder CompanyPlanet Beyond LLC
November 12, 2020 Equipment Autorisation Division Federal Communications Commission 7435 Oakland Mills Road Columbia, MD 21046 FCC ID: 2AX2J-PB02 Product Name: PB02 Request for Confidentiality Pursuant to Sections 0.457 and 0.459 of the commissions rules, we hereby request that the following documents be held confidential: (List here the documents for which you are seeking confidentiality – for example ...) • Schematics • Block diagram • Operation description These materials contain trade secrets and proprietary information and are not customarily released to the public. The public disclosure of this information might be harmful to the company and provide unjustified benefits to our competitors. <Signature> NameChristian Melvin TitleCo-Founder CompanyPlanet Beyond LLC
FCC ID: 2AX2J-PB02 Model: PB02 Capacity: 10000mAh(34Wh) Input:5V 2A Output: 5V 2.1A
Label Location
FCC ID: 2AX2J-PB02 RF Exposure Evaluation 1 Measuring Standard KDB 680106 D01 RF Exposure Wireless Charging App v03 And KDB Tracking Number 671578 ; TCB Workshop, October 2018, 5.2 RF Exposure Procedures 2 Requirements According to the item 5 of KDB 680106 D01 RF Exposure Wireless Charging App v03: (1) Power transfer frequency is less than 1 MHz. Yes (2) Output power from each primary coil is less than or equal to 15 watts. Yes (3) The transfer system includes only single primary and secondary coils. This includes charging systems that may have multiple primary coils and clients that are able to detect and allow coupling only between individual pairs of coils. Yes (3) Client device is placed directly in contact with the transmitter. Yes (5) Mobile exposure conditions only (portable exposure conditions are not covered by this exclusion). No (6) The aggregate H-field strengths at 15 cm surrounding the device and 20 cm above the top surface from all simultaneous transmitting coils are demonstrated to be less than 50% of the MPE limit. Yes Limits The criteria listed in the following table shall be used to evaluate the environment impact of human exposure to radio frequency (RF) radiation as specified in 1.1307(b) Limits for Maximum Permissible Exposure (MPE) Report No.: TW2010056-H Page 2 of 5 Date: 2020-10-22 The report refers only to the sample tested and does not apply to the bulk. This report is issued in confidence to the client and it will be strictly treated as such by the SHENZHEN TIMEWAY TESTING LABORATORIES.It may not be reproduced rather in its entirety or in part and it may not be used for adverting. The client to whom the report is issued may, however, show or send it . or a certified copy there of prepared by the SHENZHEN TIMEWAY TESTING LABORATORIES. to his customer. Supplier or others persons directly concerned. SHENZHEN TIMEWAY TESTING LABORATORIES. will not, without the consent of the client enter into any discussion of correspondence with any third party concerning the contents of the report. In the event of the improper use of the report. The SHENZHEN TIMEWAY TESTING LABORATORIES.reserves the rights to withdraw it and to adopt any other remedies which may be appropriate. 3 Test Setup A: B: Report No.: TW2010056-H Page 3 of 5 Date: 2020-10-22 The report refers only to the sample tested and does not apply to the bulk. This report is issued in confidence to the client and it will be strictly treated as such by the SHENZHEN TIMEWAY TESTING LABORATORIES.It may not be reproduced rather in its entirety or in part and it may not be used for adverting. The client to whom the report is issued may, however, show or send it . or a certified copy there of prepared by the SHENZHEN TIMEWAY TESTING LABORATORIES. to his customer. Supplier or others persons directly concerned. SHENZHEN TIMEWAY TESTING LABORATORIES. will not, without the consent of the client enter into any discussion of correspondence with any third party concerning the contents of the report. In the event of the improper use of the report. The SHENZHEN TIMEWAY TESTING LABORATORIES.reserves the rights to withdraw it and to adopt any other remedies which may be appropriate. 4 Test Procedure 1) The RF exposure test was performed in an echoic chamber; 2) The measurement probe was placed at test distance(15 cm from edges, 20 cm from top) Which is between the edge of the charger and the geometric center of probe, for test setup A; 3) In addition to what is described in KDB 680106 D01, please measure and provide magnetic and electrical field strength at a distance 10cm to 1cm at 1cm iteration, i.e. at a distance of 10cm, 9cm, 8cm, ....... 1cm. Which is between the edge of the charger and the edge of probe, for test setup B; 4) The highest emission level was recorded and compared with limit as soon as measurement of each points (A,B, C,D, E)were completed; 5) The EUT was measured according to the dictates of KDB680106D01v03; And KDB Tracking Number 671578 ; TCB Workshop, October 2018, 5.2 RF Exposure Procedures Remark:The EUT’ s test position A, B,C, D and E is valid for the E and H field measurements. 5 Test Instruments list Test Equipment Manufacturer Model No. SN. Cal.Date (mm-dd-yy) Cal.Due date (mm-dd-yy) EMF Meter NARDA ELT-400 N-0356 Oct 10, 2020 Oct 9, 2021 EMF probe NARDA B-Field Probe M-0812 Oct 10, 2020 Oct 9, 2021 6 Test Result Test Result for Test setup A: Note: Frequency Range 0.1115-0.205 (MHz); <5%, 50 %,> 90% load all have been tested, Only worse case Max load (>90%) is reported. E-Filed Strength at (15 cm from edges A, B, C, D, 20 cm from top E) surrounding the EUT (V/m) Charging Load Worse case Test Position A(V/m) Test Position B(V/m) Test Position C(V/m) Test Position D(V/m) Test Position E(V/m) Limits (V/m) Max load 1.36 1.29 1.24 1.18 1.26 614 H-Filed Strength at (15 cm from edges A, B, C, D, 20 cm from top E) surrounding the EUT (A/m) Charging Load Worse case Test Position A(A/m) Test Position B(A/m) Test Position C(A/m) Test Position D(A/m) Test Position E(A/m) Limits (A/m) Max load 0.53 0.49 0.41 0.38 0.32 1.63 Report No.: TW2010056-H Page 4 of 5 Date: 2020-10-22 The report refers only to the sample tested and does not apply to the bulk. This report is issued in confidence to the client and it will be strictly treated as such by the SHENZHEN TIMEWAY TESTING LABORATORIES.It may not be reproduced rather in its entirety or in part and it may not be used for adverting. The client to whom the report is issued may, however, show or send it . or a certified copy there of prepared by the SHENZHEN TIMEWAY TESTING LABORATORIES. to his customer. Supplier or others persons directly concerned. SHENZHEN TIMEWAY TESTING LABORATORIES. will not, without the consent of the client enter into any discussion of correspondence with any third party concerning the contents of the report. In the event of the improper use of the report. The SHENZHEN TIMEWAY TESTING LABORATORIES.reserves the rights to withdraw it and to adopt any …
Text truncated - open the document above for the full version.
Ref Lvl 0 dBm Ref Lvl 0 dBm RF Att 10 dB A 1MA UnitdBm Center 175 kHzSpan 10 kHz1 kHz/ RBW 1 kHz VBW 3 kHz SWT 150 ms 1MAX -90 -80 -70 -60 -50 -40 -30 -20 -10 -100 0 1 T1 T2 Marker 1 [T1 ndB] ndB 20.00 dB BW 3.38677355 kHz 1 [T1] -40.63 dBm 174.96993988 kHz ndB 20.00 dB BW 3.38677355 kHz T1 [T1] -60.81 dBm 173.32665331 kHz T2 [T1] -60.65 dBm 176.71342685 kHz Date: 21.OCT.2020 10:17:14
Conducted Emission Te s t Setup: Radiated Emission Te s t Setup:
| # | Rule Parts | Frequency Range | Power Output |
|---|---|---|---|
| 1 | 15C | 0.1115 MHz - 0.205 MHz | - |

PB01X
Equipment Class
DTS - Digital Transmission System