Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.
HYPERVIBE OWNERS MANUAL HOME 1 | Page Contents Introduction ..................................................... 2 Gravity Resistance Training (GRT) .................... 3 Benefits of GRT ............................................... 5 Instruction Manual ............................................ 6 Important Health Precautions ....................... 11 Assembly Instructions .................................... 13 Upper body resistance bands ......................... 15 Safe & Effective Use ...................................... 17 Using the Control panel ................................. 21 Getting started .............................................. 21 Maintenance .................................................. 22 Specifications ................................................. 23 Troubleshooting ............................................ 24 2 | Page Introduction Congratulations on your purchase of the Hypervibe - G14 Home, Gravity Resistance Training machine. Small, lightweight and powerful, the G14 Home is a portable powerhouse coupled with innovation. Not only does the G14 Home bring you power that is typically unheard of in similar portable platforms, but for the first time ever, Hypervibe brings you a vibration machine with an Android based touch screen that allows you to control or program the machine via devices such as smartphones, MP3 players, and tablets. Simply connect the Hypervibe G14 software to Wi-Fi and the App will tell the G14 Home what to do and show you how to work out through your choice of 40 goal-based programs. The Hypervibe G14 Home app includes live G-Force readings 1 corresponding to a Low, Medium, and High position on the platform. G-Force is the key to vibration intensity, and for most benefits, the key to getting results. Yet other machines don’t provide you with this crucial information, often it’s not even provided in the technical specifications. 1 G-Force readings are calculated theoretical values. 3 | Page Gravity Resistance Training (GRT) There is a wide spread myth about Whole Body Vibration originating in Russia during the 70’s and used for the health of their cosmonauts and the performance of their Olympic athletes. The reality is that modern Whole-Body Vibration began in Germany during the mid-nineties. The pioneering machines were very powerful and designed to increase the gravitational forces acting on a user by applying rapid pulses of vertical force under the users’ feet, triggering a range of responses and benefits. Over the years as more manufacturers started to release less powerful Whole-Body Vibration platforms, the original concept became somewhat lost. Gravity Resistance Training refers to the actual training principle by which users of a Whole- Body Vibration platform experience tremendous benefit to their muscles, bones, and bodies. What sets apart a GRT machine from a regular vibration machine, is its ability to produce high levels of gravity (acceleration), just like the pioneering technology from Germany. In simple terms, this means that the platform’s upward vertical force can simulate more than 10 times the strength of Earth’s gravity. While manufacturers of low powered machines attempt to use smoke and mirrors, we at Hypervibe focus on the reality of Whole Body Vibration technology and what sets it apart from other approaches to health and fitness. We focus on its ability to provide true Gravity Resistance! After all, is Gravity not the force we fight against every day in our lives. Is not our failure to fight gravity 4 | Page responsible for many of the physical issues we face? No matter how you look at it, the fundamental need to maintain our ability to counter gravity is what defines our strength, stability, balance, function, and most importantly, our healthy lifestyle. It’s time to stop just shaking the body and begin to actually improve its performance and integrity. It’s time for Whole Body Vibration to become Gravity Resistance Training. 5 | Page Benefits of GRT At the time this was written, the effects of GRT had been studied for almost 20 years, with hundreds of clinical papers published in scientific journals. Improved Balance Improved Bone Density Increased Muscle Strength Increased Circulation Increased Flexibility Improved Body Composition Improved Hormonal Profile Cellulite Reduction Increased Muscle Power Pre-Exercise Warm-Up Improved Exercise Recovery Lower Back Pain Relief Joint Protection Reduced Swelling Neurological Stimulation Treatment of Systemic Conditions 6 | Page Instruction Manual Familiarize yourself with this manual and look it over carefully. Be sure you understand the control panel operation and the safe exercise positions before using the G14 Home. ! - NEITHER HYPERVIBE NOR ITS REPRESENTATIVES CAN ACCEPT RESPONSIBILITY FOR ANY DAMAGE OR INJURY INCURRED AS A RESULT FROM INFORMATION PRESENTED IN THIS MANUAL EXCEPT UNDER THE TERMS OF THE PRODUCT WARRANTY. Important Product Safety Instructions ! - DANGER: WHEN USING AN ELECTRICAL APPLIANCE, BASIC PRECAUTIONS SHOULD ALWAYS BE FOLLOWED, INCLUDING THE FOLLOWING. READ ALL INSTRUCTIONS BEFORE USING THIS MACHINE. To reduce risk of burns, fire, electrical shock or injury to persons: 1. Always ensure proper operation of your Hypervibe, it is recommended that your Hypervibe machine be connected to a dedicated 120V 60Hz (North America) or 240 V 50Hz (Asia Pacific/ Europe) electrical circuit. DO NOT USE ELECTRICAL EXTENSION CORDS OR POWER ADAPTORS. 2. Always unplug this machine from the electrical outlet immediately after using and before cleaning. 7 | Page 3. The machine should never be left unattended when plugged in. Unplug from outlet when not in use and before putting on or taking off parts. • Do not operate under blanket or pillow. Excessive heating can occur and cause fire, electric shock or injury to persons. • Close supervision is necessary when this machine is used by, on or near children, invalids or disabled persons. • Use this machine …
Text truncated - open the document above for the full version.
CONFIDENTIALITY REQUEST for Certification Service in USA Federal Communication Commission Equipment Authorization Division, Application Processing Branch 7435 Oakland Mills Road Columbia, MD 21046 < Nov. 14, 2020 > TO WHOM IT MAY CONCERN Pursuant to Paragraphs §0.457 and 0.459 of the Commission’s Rules (47 C.F.R.) and Section §552(b)(4) of the Freedom of Information Act, we requests confidentiality for the following products: Name CUSTOM DESIGN MOTORVATO Model G14 HOME V3 FCC ID 2AX2Q-HVG14-2020 For the product stated above, we request that the following information be held confidential; Exhibits Long-Term Confidentiality Short-Term Confidentiality Short-Term Confidentiality Days External Photos Internal Photos Block Diagram Schematics Test Setup Photos User’s Manual Parts List Tune Up Operational Descriptions The long-term confidentiality exhibits contain our trade secrets and proprietary information that could be of benefit to our competitors. The short-term confidentiality on the basis of ensuring that business sensitive information remains confidential until the actual marketing of our new device. If you have any questions, please feel free to contact me at the address shown below. Sincerely, (Signed) Name / Title: Wang Ronghui/ Product Development Engineer Company: ZHANGZHOU LI-YUAN SPORTING GOODS CO., LTD Address: No.198,East Xingtai Road,Xingtai Industrial Park,Changtai,Zhangzhou, Fujian,China Phone: 0596-7022792 E-Mail: [email protected]
ZHANGZHOU LI-YUAN SPORTING GOODS CO., LTD No.198,East Xingtai Road,Xingtai Industrial Park,Changtai,Zhangzhou, Fujian,China Federal Communications Commission Authorization and Evaluation Division Equipment Authorization Branch 7435 Oakland Mills Road Columbia, MD 21046 11/14/2020 To whom it may concern: We, ZHANGZHOU LI-YUAN SPORTING GOODS CO., LTD the undersigned, hereby authorize Eurofins Product Service GmbH to act on our behalf in all matters relating to applications for equipment authorization FCC ID: 2AX2Q-HVG14-2020 including the signing of all documents related to these matters. Any and all acts carried out by Eurofins Product Service GmbH on our behalf shall have the same effect as acts of our own. We also hereby certify that no party to this application is subject to a denial of benefits, including FCC benefits, pursuant to Section 5301 of the Anti-Drug Abuse Act of 1988, 21 U.S.C. 862. Sincerely, (Signed) Name / Title: Wang Ronghui/ Product Development Engineer Company: ZHANGZHOU LI-YUAN SPORTING GOODS CO., LTD Address: No.198,East Xingtai Road,Xingtai Industrial Park,Changtai,Zhangzhou, Fujian,China Phone: 0596-7022792 E-Mail: [email protected]
FCC ID: 2AX2Q-HVG14-2020 FCC ID: 2AX2Q-HVG14-2020 FCC ID: 2AX2Q-HVG14-2020
FCC ID: 2AX2Q-HVG14-2020 FCC ID: 2AX2Q-HVG14-2020 FCC ID: 2AX2Q-HVG14-2020 FCC ID: 2AX2Q-HVG14-2020 FCC ID: 2AX2Q-HVG14-2020
RF Exposure evaluation FCC ID: 2AX2Q-HVG14-2020 1. Reference According to §1.1307(b)(1), systems operating under the provisions of this section shall be operated in a manner that ensures that the public is not exposed to radio frequency energy level in excess of the Commission’s guidelines. According to §1.1310 and §2.1091 RF exposure is calculated. KDB447498 D01: Mobile and Portable Devices RF Exposure Procedures and Equipment Authorization Policies 2. Limit Limits for Maximum Permissible Exposure (MPE)/Controlled Exposure Frequency Range(MHz) Electric Field Strength(V/m) Magnetic Field Strength(A/m) Power Density (mW/cm²) Averaging Time (minute) Limits for Occupational/Controlled Exposure 0.3 – 3.0 3.0 – 30 30 – 300 300 – 1500 1500 – 100,000 614 1842/f 61.4 / / 1.63 4.89/f 0.163 / / (100) * (900/f 2 )* 1.0 f/300 5 6 6 6 6 6 Limits for Maximum Permissible Exposure (MPE)/Uncontrolled Exposure Frequency Range(MHz) Electric Field Strength(V/m) Magnetic Field Strength(A/m) Power Density (mW/cm²) Averaging Time (minute) Limits for Occupational/Controlled Exposure 0.3 – 3.0 3.0 – 30 30 – 300 300 – 1500 1500 – 100,000 614 824/f 27.5 / / 1.63 2.19/f 0.073 / / (100) * (180/f 2 )* 0.2 f/1500 1.0 30 30 30 30 30 F=frequency in MHz *=Plane-wave equivalent power density 3. Manufacturing tolerance Frequency (MHz) IEEE 802.11b (Peak) 2412 2437 2462 Target (dBm) 17.00 17.00 17.00 Tolerance ± (dB) 1.0 1.0 1.0 Frequency (MHz) IEEE 802.11g (Peak) 2412 2437 2462 Target (dBm) 18.50 18.50 18.50 Tolerance ± (dB) 1.0 1.0 1.0 Frequency (MHz) IEEE 802.11n HT20 (Peak) 2412 2437 2462 Target (dBm) 18.50 18.50 18.50 Tolerance ± (dB) 1.0 1.0 1.0 Frequency (MHz) IEEE 802.11n HT20 (Peak) 2422 2437 2452 Target (dBm) 19.0 19.0 19.0 Tolerance ± (dB) 1.0 1.0 1.0 4. MPE Calculation Method Predication of MPE limit at a given distance Equation from page 18 of OET Bulletin 65, Edition 97-01 S=PG/4πR² Where: S=power density P=power input to antenna G=power gain of the antenna in the direction of interest relative to an isotropic radiator R=distance to the center of radiation of the antenna 5. Result As declared by the Applicant, the EUT is a wireless device used in a fix application, at least 20 cm from any body part of the user or nearby persons; from the maximum EUT RF output power, the minimum separation distance, r =15cm, as well as the gain of the used antenna is 1.00 dBi, the RF power density can be obtained. Modulation Type Max tune up power tolerance(dBm) Max Output power to antenna (mW) Antenna Gain (dBi) Antenna Gain (Numeric) Power Density at R=15cm (mW/cm2) Limit (mW/cm2) Result 11b 18.0 63.09573 1.0 1.258925 0.015811 1.0 Pass 11g 19.5 89.12509 1.0 1.258925 0.022333 1.0 Pass 11n(HT20) 19.5 89.12509 1.0 1.258925 0.022333 1.0 Pass 11n(HT40) 20.0 100.0000 1.0 1.258925 0.025058 1.0 Pass 6. Conclusion The measurement results comply with the FCC Limit per 47 CFR 2.1091 for the uncontrolled RF Exposure of mobile device.
Shenzhen Global Test Service Co.,Ltd. No.7-101 and 8A-104, Building 7 and 8, DCC Cultural and Creative Garden, No.98, Pingxin North Road, Shangmugu Community, Pinghu Street, Longgang District, Shenzhen, Guangdong FCC PART 15 SUBPART C TEST REPORT FCC PART 15.247 Report Reference No. ..................... : FCC ID. ............................................ : GTS20201030003-1-1 2AX2Q-HVG14-2020 Compiled by ( position+printed name+signature) .. : File administrators Jimmy Wang Supervised by ( position+printed name+signature) .. : Test Engineer Aaron Tan Approved by ( position+printed name+signature) .. : Manager Jason Hu Date of issue ..................................... : Nov.07, 2020 Representative Laboratory Name .: Shenzhen Global Test Service Co.,Ltd. Address ............................................ : No.7-101 and 8A-104, Building 7 and 8, DCC Cultural and Creative Garden, No.98, Pingxin North Road, Shangmugu Community, Pinghu Street, Longgang District, Shenzhen, Guangdong, China Applicant’s name ............................ : ZHANGZHOU LI-YUAN SPORTING GOODS CO., LTD Address ............................................ : No.198,East Xingtai Road,Xingtai Industrial Park,Changtai,Zhangzhou,Fujian,China Test specification ...........................: Standard ........................................... : FCC Part 15.247 Shenzhen Global Test Service Co.,Ltd. All rights reserved. This publication may be reproduced in whole or in part for non-commercial purposes as long as the Shenzhen Global Test Service Co.,Ltd. is acknowledged as copyright owner and source of the material. Shenzhen Global Test Service Co.,Ltd. takes no responsibility for and will not assume liability for damages resulting from the reader's interpretation of the reproduced material due to its placement and context. Test item description .....................: CUSTOM DESIGN MOTORVATO Trade Mark ....................................... : N/A Manufacturer ................................... : ZHANGZHOU LI-YUAN SPORTING GOODS CO., LTD Model/Type reference....................... : G14 HOME V3 Listed Models .................................. : N/A Ratings ............................................. : AC 120V/60Hz Modulation ....................................... : CCK/DSSS, OFDM Hardware version ............................. : V3 Software version .............................. : V3 Frequency .......................................... From 2412MHz to 2462MHz Result................................................ : PASS Report No.: GTS20201030003-1-1 Page 2 of 43 T E S T R E P O R T Test Report No. : GTS20201030003-1-1 Nov.07, 2020 ____________________________________________________________________________________ Date of issue Equipment under Test : CUSTOM DESIGN MOTORVATO Model /Type : G14 HOME V3 Listed Models : N/A Applicant : ZHANGZHOU LI-YUAN SPORTING GOODS CO., LTD Address : No.198,East Xingtai Road,Xingtai Industrial Park,Changtai, Zhangzhou,Fujian,China Manufacturer : ZHANGZHOU LI-YUAN SPORTING GOODS CO., LTD Address : No.198,East Xingtai Road,Xingtai Industrial Park,Changtai, Zhangzhou,Fujian,China Test Result: PASS The test report merely corresponds to the test sample. It is not permitted to copy extracts of these test result without the written permission of the test laboratory. Report No.: GTS20201030003-1-1 Page 3 of 43 Contents 1 T E S T S T A N D A R D S ................................................................. 4 2 S U M M A R Y ............................................................................ 5 2.1 General Remarks 5 2.2 Product Description 5 2.3 Equipment Under Test 5 2.4 Short description of the Equipment under Test (EUT) 5 2.5 EUT operation mode 6 2.6 Block Diagram of Test Setup 6 2.7 Special Accessories 6 2.8 Related Submittal(s) / Grant (s) 6 2.9 Modifications 6 3 TES T E N V I R O N M E N T .............................................................. 7 3.1 Address of the test laboratory 7 3.2 Test Facility 7 3.3 Environmental conditions 7 3.4 Test Description 8 3.5 Statement of the measurement uncertainty 9 3.6 Equipments Used during the Test 9 4 T E S T C O N D I T I O N S A N D R E S U L T S ........................................... 11 4.1 AC Power Conducted Emission 11 4.2 Radiated Emission 14 4.3 Maximum Conducted Output Power 20 4.4 Power Spectral Density 21 4.5 6dB Bandwidth 24 4.6 Out-of-band Emissions 27 4.7 Antenna Requirement 34 5 T E S T S E T U P P H O T O S O F T H E E U T ......................................... 35 6 P H O T O S O F T H E E U T ........................................................... 36 Report No.: GTS20201030003-1-1 Page 4 of 43 1 T E S T S T A N D A R D S The tests were performed according to following standards: FCC Rules Part 15.247: Frequency Hopping, Direct Spread Spectrum and Hybrid Systems that are in operation within the bands of 902-928 MHz, 2400-2483.5 MHz, and 5725-5850 MHz. ANSI C63.10-2013: American National Standard for Testing Unlicensed Wireless Devices KDB558074 D01 V05r02: Guidance for Compliance Measurements on Digital Transmission Systems (DTS) ,Frequency Hopping Spread Spectrum System(HFSS), and Hybrid System Devices Operating Under §15.247 of The FCC rules. Report No.: GTS20201030003-1-1 Page 5 of 43 2 S U M M A R Y 2.1 General Remarks Date of receipt of test sample : Oct. 20, 2020 Testing commenced on : Oct. 20, 2020 Testing concluded on : Nov. 07, 2020 2.2 Product Description Product Description: CUSTOM DESIGN MOTORVATO Model/Type reference: G14 HOME V3 Power supply: AC 120V/60Hz Testing sample ID: GTS20201030003-1-1#(Engineer sample), GTS20201030002-1-2#(Normal sample) WIFI Supported type: 802.11b/802.11g/802.11n(H20)/802.11n(H40) Modulation: 802.11b: DSSS 802.11g/802.11n(H20)/ 802.11n(H40): OFDM Operation frequency: 802.11b/802.11g/802.11n(H20): 2412MHz~2462MHz 802.11n(H40): 2422MHz~2452MHz Channel number: 802.11b/802.11g/802.11n(H20): 11 802.11n(H40): 7 Channel separation: 5MHz Antenna type: PCB antenna Antenna g…
Text truncated - open the document above for the full version.
FCC ID: 2AX2Q-HVG14-2020 FCC ID: 2AX2Q-HVG14-2020
| # | Rule Parts | Frequency Range | Power Output |
|---|---|---|---|
| 2 | 15C | 2.42 GHz - 2.45 GHz | 96.80 mW |

CUSTOM DESIGN MOTORVATO
Equipment Class
DTS - Digital Transmission System
CUSTOM DESIGN MOTORVATO
Equipment Class
DTS - Digital Transmission System