Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.
Project No.: 2105C130 Page 1 of 11 ATTACHMENT PHOTOGRAPHS OF EUT Project No.: 2105C130 Page 2 of 11 Project No.: 2105C130 Page 3 of 11 Project No.: 2105C130 Page 4 of 11 Project No.: 2105C130 Page 5 of 11 Project No.: 2105C130 Page 6 of 11 Model: SA182V-120150U Project No.: 2105C130 Page 7 of 11
Project No.: 2105C130 Page 8 of 11 5G Ant3 2.4G Ant2 5G Ant2 5G Ant1 5G Ant4 2.4G Ant1 Project No.: 2105C130 Page 9 of 11 Project No.: 2105C130 Page 10 of 11 Project No.: 2105C130 Page 11 of 11
Report No.: BTL-FCCP-3-2105C130 Page 1 of 5 FCC RF EXPOSURE REPORT FCC ID: 2AX3BCTG6 Project No. : 2105C130 Equipment : AC2100 DUAL BAND GIGABIT WIFI ROUTER Brand Name : Connectize Test Model : G6 Series Model : G6X (X can be A, B, C, D, E, F, G, H, I, J, K, L, M, N, O, P, Q, R, S, T, U, V, W, X, Y, Z and blank.) Applicant : SHENZHEN TENO NETWORK TECHNOLOGIES CO.,LTD Address : NO.415, 4F, ZHONGZHI NEXONE BUILDING, SANLIAN COMMUNITY, LONGHUA STREET, LONGHUA DISTRICT, SHENZHEN, CHINA Manufacturer : SHENZHEN TENO NETWORK TECHNOLOGIES CO.,LTD Address : NO.415, 4F, ZHONGZHI NEXONE BUILDING, SANLIAN COMMUNITY, LONGHUA STREET, LONGHUA DISTRICT, SHENZHEN, CHINA Date of Receipt : May 20, 2021 Date of Test : May 20, 2021~ Jun. 18, 2021 Issued Date : Jun. 29, 2021 Report Version : R00 Test Sample : Engineering Sample No.: DG2021052034 Standard(s) : FCC Part 2.1091 FCC Title 47 Part 2.1091 KDB 447498 D01 General RF exposure guidance v06 The above equipment has been tested and found compliance with the requirement of the relative standards by BTL Inc. Prepared by : Maker Qi Approved by : Issac Song Add: No. 29, Jintang Road, Tangzhen Industry Park, Pudong New Area, Shanghai 201210,China TEL: +86-021-61765666 Web: www.newbtl.com Report No.: BTL-FCCP-3-2105C130 Page 2 of 5 REPORT ISSUED HISTORY Report Version Description Issued Date R00 Original Issue. Jun. 29, 2021 Report No.: BTL-FCCP-3-2105C130 Page 3 of 5 1. MPE CALCULATION METHOD Calculation Method of RF Safety Distance: where: S = power density P = power input to the antenna G = power gain of the antenna in the direction of interest relative to an isotropic radiator R = distance to the center of radiation of the antenna Table for Filed Antenna For 2.4G Ant. Brand Model Name Antenna Type Connector Gain(dBi) 1 N/A N/A Dipole N/A 5 2 N/A N/A Dipole N/A 5 Note: 1. This EUT supports CDD, all antennas have the same gain, any transmit signals are correlated with each other, so for power spectral density measurements, the Directional gain=G ANT +Array Gain, that is Directional gain=5+10log(2/1) =8.01; Power spectral density limit is 8-8.01+6=5.99. For power meansurements, Directional gain =G ANT MAX. +Array Gain, Array Gain=0dB(N ANT ≤4), so the Directional gain=5. 2. The antenna gain is provided by the manufacturer. Operating Mode TX Mode Ant. 1 Ant. 2 Ant. 1+2 IEEE 802.11b ˟ IEEE 802.11g ˟ IEEE 802.11n(HT20) IEEE 802.11n(HT40) Report No.: BTL-FCCP-3-2105C130 Page 4 of 5 For 5G Ant. Brand Model Name Antenna Type Connector Gain(dBi) 1 N/A N/A Dipole N/A 5 2 N/A N/A Dipole N/A 5 3 N/A N/A Dipole N/A 5 4 N/A N/A Dipole N/A 5 Note: 1.This EUT supports Beamforming and CDD, all antennas have the same gain, any transmit signals are correlated with each other, so 1) Beamforming: Directional gain = 10log[(10 G1/20 +10 G2/20 +....+10 GN/20 ) 2 /N ANT ]dBi, that is Directional gain=10log[(10 G1/20 +10 G2/20 +....+10 GN/20 ) 2 /N ANT ]dBi =11.02; Then, the UNII-1, UNII-3 output power limit is 30-11.02+6=24.98. The UNII-1 power spectral density limit is 17-11.02+6=11.98, the UNII-3 power spectral density limit is 30-11.02+6=24.98. 2) CDD: For power spectral density measurements, the Directional gain=G ANT +Array Gain, that is Directional gain=5+10log(4/1) =6.01; Then, the UNII-1 power spectral density limited is 17-11.02+6=11.98, the UNII-3 power spectral density limit is 30-11.02+6=24.98. For power meansurements, Directional gain= G ANT MAX. +Array Gain. Array Gain=0dB(N ANT ≤4), so the Directional gain=5. 2. The antenna gain and beamforming gain are provided by the manufacturer. Operating Mode TX Mode Ant. 1 Ant. 2 Ant. 3 Ant. 4 Ant. 1+2+3+4 IEEE 802.11a ˟ IEEE 802.11n(HT20) IEEE 802.11n(HT40) IEEE 802.11ac(VHT20) IEEE 802.11ac(VHT40) IEEE 802.11ac(VHT80) Report No.: BTL-FCCP-3-2105C130 Page 5 of 5 2. TEST RESULTS For 2.4GHz: CDD: Antenna Gain (dBi) Antenna Gain (numeric) Max. tune up Power (dBm) Max. tune up Power (mW) Power Density (S) (mW/cm 2 ) Limit of Power Density (S) (mW/cm 2 ) Test Result 5.00 3.1623 22.00 158.4893 0.099708 1 Complies For 5GHz : Beamforming Antenna Gain (dBi) Antenna Gain (numeric) Max. tune up Power (dBm) Max. tune up Power (mW) Power Density (S) (mW/cm 2 ) Limit of Power Density (S) (mW/cm 2 ) Test Result 11.02 12.6474 24.00 251.1886 0.632019 1 Complies CDD: Antenna Gain (dBi) Antenna Gain (numeric) Max. tune up Power (dBm) Max. tune up Power Power (mW) Power Density (S) (mW/cm 2 ) Limit of Power Density (S) (mW/cm 2 ) Test Result 5.00 3.1623 25.00 316.2278 0.198945 1 Complies For the max simultaneous transmission MPE: 2.4G+5G Power Density (S) (mW/cm 2 ) Power Density (S) (mW/cm 2 ) Total Limit of Power Density (S) (mW/cm 2 ) Test Result 2.4GHz 5GHz 0.099708 0.632019 0.731727 1 Complies Note: The calculated distance is 20 cm. Output power including tune up tolerance. End of Test Report
Report No.: BTL-FCCP-1-2105C130 Page 1 of 109 FCC Radio Test Report FCC ID: 2AX3BCTG6 This report concerns: Original Grant Project No. : 2105C130 Equipment : AC2100 DUAL BAND GIGABIT WIFI ROUTER Brand Name : Connectize Test Model : G6 Series Model : G6X (X can be A, B, C, D, E, F, G, H, I, J, K, L, M, N, O, P, Q, R, S, T, U, V, W, X, Y, Z and blank.) Applicant : SHENZHEN TENO NETWORK TECHNOLOGIES CO.,LTD Address : NO.415, 4F, ZHONGZHI NEXONE BUILDING, SANLIAN COMMUNITY, LONGHUA STREET, LONGHUA DISTRICT, SHENZHEN, CHINA Manufacturer : SHENZHEN TENO NETWORK TECHNOLOGIES CO.,LTD Address : NO.415, 4F, ZHONGZHI NEXONE BUILDING, SANLIAN COMMUNITY, LONGHUA STREET, LONGHUA DISTRICT, SHENZHEN, CHINA Date of Receipt : May 20, 2021 Date of Test : May 20, 2021~Jun. 18, 2021 Issued Date : Jun. 29, 2021 Report Version : R00 Test Sample : Engineering Sample No.: DG2021052034 Standard(s) : FCC CFR Title 47, Part 15, Subpart C FCC KDB 558074 D01 15.247 Meas Guidance v05r02 FCC KDB 662911 D01 Multiple Transmitter Output v02r01 ANSI C63.10-2013 The above equipment has been tested and found compliance with the requirement of the relative standards by BTL Inc. Prepared by : Maker Qi Approved by : Issac Song Add: No. 29, Jintang Road, Tangzhen Industry Park, Pudong New Area, Shanghai 201210,China TEL: +86-021-61765666 Web: www.newbtl.com Report No.: BTL-FCCP-1-2105C130 Page 2 of 109 Declaration BTL represents to the client that testing is done in accordance with standard procedures as applicable and that test instruments used has been calibrated with standards traceable to international standard(s) and/or national standard(s). BTL's reports apply only to the specific samples tested under conditions. It is manufacture’s responsibility to ensure that additional production units of this model are manufactured with the identical electrical and mechanical components. BTL shall have no liability for any declarations, inferences or generalizations drawn by the client or others from BTL issued reports. The report must not be used by the client to claim product certification, approval, or endorsement by NVLAP, NIST, A2LA, or any agency of the U.S. Government. This report is the confidential property of the client. As a mutual protection to the clients, the public and ourselves, the test report shall not be reproduced, except in full, without our written approval. BTL’s laboratory quality assurance procedures are in compliance with the ISO/IEC 17025 requirements, and accredited by the conformity assessment authorities listed in this test report. BTL is not responsible for the sampling stage, so the results only apply to the sample as received. The information, data and test plan are provided by manufacturer which may affect the validity of results, so it is manufacturer’s responsibility to ensure that the apparatus meets the essential requirements of applied standards and in all the possible configurations as representative of its intended use. Limitation For the use of the authority's logo is limited unless the Test Standard(s)/Scope(s)/Item(s) mentioned in this test report is (are) included in the conformity assessment authorities acceptance respective. Please note that the measurement uncertainty is provided for informational purpose only and are not use in determining the Pass/Fail results. Report No.: BTL-FCCP-1-2105C130 Page 3 of 109 Table of Contents Page REPORT ISSUED HISTORY 6 1 . SUMMARY OF TEST RESULTS 7 1.1 TEST FACILITY 8 1.2 MEASUREMENT UNCERTAINTY 8 1.3 TEST ENVIRONMENT CONDITIONS 8 2 . GENERAL INFORMATION 9 2.1 GENERAL DESCRIPTION OF EUT 9 2.2 DESCRIPTION OF TEST MODES 11 2.3 PARAMETERS OF TEST SOFTWARE 13 2.4 DUTY CYCLE 14 2.5 BLOCK DIAGRAM SHOWING THE CONFIGURATION OF SYSTEM TESTED 16 2.6 SUPPORT UNITS 16 3 . AC POWER LINE CONDUCTED EMISSIONS 17 3.1 LIMIT 17 3.2 TEST PROCEDURE 17 3.3 DEVIATION FROM TEST STANDARD 17 3.4 TEST SETUP 18 3.5 EUT OPERATION CONDITIONS 18 3.6 TEST RESULTS 18 4 . RADIATED EMISSIONS 19 4.1 LIMIT 19 4.2 TEST PROCEDURE 20 4.3 DEVIATION FROM TEST STANDARD 21 4.4 TEST SETUP 21 4.5 EUT OPERATION CONDITIONS 22 4.6 TEST RESULTS - 9 KHZ TO 30 MHZ 22 4.7 TEST RESULTS - 30 MHZ TO 1000 MHZ 22 4.8 TEST RESULTS - ABOVE 1000 MHZ 22 5 . BANDWIDTH 23 5.1 LIMIT 23 5.2 TEST PROCEDURE 23 5.3 DEVIATION FROM STANDARD 23 5.4 TEST SETUP 23 Report No.: BTL-FCCP-1-2105C130 Page 4 of 109 Table of Contents Page 5.5 EUT OPERATION CONDITIONS 23 5.6 TEST RESULTS 23 6 . MAXIMUM OUTPUT POWER 24 6.1 LIMIT 24 6.2 TEST PROCEDURE 24 6.3 DEVIATION FROM STANDARD 24 6.4 TEST SETUP 24 6.5 EUT OPERATION CONDITIONS 24 6.6 TEST RESULTS 24 7 . CONDUCTED SPURIOUS EMISSIONS 25 7.1 LIMIT 25 7.2 TEST PROCEDURE 25 7.3 DEVIATION FROM STANDARD 25 7.4 TEST SETUP 25 7.5 EUT OPERATION CONDITIONS 25 7.6 TEST RESULTS 25 8 . POWER SPECTRAL DENSITY 26 8.1 LIMIT 26 8.2 TEST PROCEDURE 26 8.3 DEVIATION FROM STANDARD 26 8.4 TEST SETUP 26 8.5 EUT OPERATION CONDITIONS 26 8.6 TEST RESULTS 26 9 . MEASUREMENT INSTRUMENTS LIST 27 10 . EUT TEST PHOTO 29 APPENDIX A - AC POWER LINE CONDUCTED EMISSIONS 32 APPENDIX B - RADIATED EMISSION - 9 KHZ TO 30 MHZ 37 APPENDIX C - RADIATED EMISSION - 30 MHZ TO 1000 MHZ 38 APPENDIX D - RADIATED EMISSION- ABOVE 1000 MHZ 41 APPENDIX E - BANDWIDTH 90 APPENDIX F - MAXIMUM OUTPUT POWER 95 APPENDIX G - CONDUCTED SPURIOUS EMISSIONS 99 Report No.: BTL-FCCP-1-2105C130 Page 5 of 109 Table of Contents Page APPENDIX H - POWER SPECTRAL DENSITY 106 Report No.: BTL-FCCP-1-2105C130 Page 6 of 109 REPORT ISSUED HISTORY Report Version Description Issued Date R00 Original Issue. Jun. 29, 2021 Report No.: BTL-FCCP-1-2105C130 Page 7 of 109 1. SUMMARY OF TEST RESULTS Test procedures according to the technical standard(s): FCC CFR Title 47, Part 15, Subpart C Standard(s) Section Test Item Test Result Judgment Remark 15.207 AC Power Line Conducted Emissions APPENDIX A PASS ------ 15.247(d) 15.205(a) 15.209(a) Radiated Emissions APPENDIX B APPENDIX C APPENDIX D PASS ------ 15.247(a)(2) Bandwidth APPENDIX E PASS ------ 15.247(b)(3) Maxim…
Text truncated - open the document above for the full version.
Report No.: BTL-FCCP-1-2105C130 Page 29 of 109 10. EUT TEST PHOTO AC Power Line Conducted Emissions Test Photos Report No.: BTL-FCCP-1-2105C130 Page 30 of 109 Radiated Emissions Test Photos 30 MHz to 1 GHz Report No.: BTL-FCCP-1-2105C130 Page 31 of 109 Radiated Emissions Test Photos Above 1 GHz
| # | Rule Parts | Frequency Range | Power Output |
|---|---|---|---|
| 1 | 15C | 2.41 GHz - 2.46 GHz | 137.10 mW |

AX1800 Dual Band Gigabit WiFi Router
Equipment Class
DTS - Digital Transmission System