Equipment Class
NII - Unlicensed National Information Infrastructure TX
Date of Grant
Dec 22, 2020
Application Purpose
Original Equipment
Date of Application
Dec 22, 2020
Equipment Note
Mini computer
Frequency Range
5745.00000000 - 5825.00000000
Company
Guangzhou Cal-Boz Electrical Science &Technology Co., Ltd
Country
China

Documents & Files

Select a file to view

Users Manual

↗

Cover Letter(s)

↗
↗
↗

External Photos

↗

ID Label/Location Info

↗

Internal Photos

↗

RF Exposure Info

↗

Test Report

↗
↗
↗

Test Setup Photos

↗

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

Users Manual

FCC Warning: This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. Changes or modifications not expressly approved by the party responsible for compliance could void the user's authority to operate the equipment. RF exposure warning: This equipment must be installed and operated in accordance with provided instructions and the antenna(s) used for this transmitter must be installed to provide a separation distance of at least 20 cm from all persons and must not be co-located or operating in conjunction with any other antenna or transmitter. End-users and installers must be provide with antenna installation instructions and transmitter operating conditions for satisfying RFexposure compliance.

Cover Letter(s)

FCC Software Configuration Control Declaration Rev1.1 (2)-2 Guangzhou Cal-Boz Electrical Science &Technology Co., Ltd FCC Software Configuration Control Declaration Date: December 21, 2020 Federal Communications Commission 7435 Oakland Mills Road Columbia, MD 21046 USA Attn: OET Dept. Product/ Model Number: Mini computer / Z83II Regarding FCC Country Code Selection guidelines identified in KDB 594280. “All applications for equipment authorization for transmitters that can have radio parameters, or other technical parameters, reported to the Commission set by software must have an attestation indicating that no third party will have software, or configuration control, to program the device out of compliance of the technical rules under which it has been certified.” We declare that no third party will have software, or configuration control, to program the device out of compliance of the technical rules under which it has been certified. Name : wang lei Date: 2020-12-10 Title: Manager Signature of applicant

Cover Letter(s)

Guangzhou Cal-Boz Electrical Science &Technology Co., Ltd Office of Engineering Technology Federal Communications Commission 7435 Oakland Mills Road Columbia, MD 21046 Date: 2020-12-08 Subject; Request for Long Term Confidentiality FCC ID: 2AX54-Z83II To Whom It May Concern, Pursuant to the provisions of the Commission’s rules Title 47 Sections §0.457 and §0.459, we are requesting the Commission to withhold the following attachment(s) as confidential documents from public disclosure indefinitely. These documents contain detailed system and equipment descriptions and are considered as proprietary information in operation of the equipment. The public disclosure of these documents might be harmful to our company and would give competitors an unfair advantage in the market. Schematic Diagram Block Diagram Operational Description It is our understanding that all measurement test reports, FCC ID label format and correspondence during the certification review process cannot be granted as confidential documents and this information will be available for public review once the grant of equipment authorization is issued. Sincerely, Signature: Name: wang lei Title: Manager

Cover Letter(s)

Guangzhou Cal-Boz Electrical Science &Technology Co., Ltd Letter of Authorization Company: Guangzhou Cal-Boz Electrical Science &Technology Co., Ltd Address: Building A-1, No.4 Weiwu Road, Zengjiang Street, Zengcheng District, Guangzhou City,Guangdong Province, China Product Name: Mini computer Model Number(s): Z83II We authorize MiCOM Labs Inc., 575 Boulder Court, Pleasanton, California 94566, USA, to act on our behalf on all matters concerning the certification of above named equipment. We declare that MiCOM Labs Inc. is allowed to forward all information related to the approval and certification of equipment to the regulatory agencies as required and to discuss any issues concerning the approval application. Any and all acts carried out by MiCOM Labs on our behalf shall have the same effect as acts of our own. Signature: Date: 2020.12.07 Name: wang lei Title: Manager Company: Guangzhou Cal-Boz Electrical Science &Technology Co., Ltd

ID Label/Location Info

Label and label location Location

Internal Photos

Antenna

RF Exposure Info

RF Exposure Report FCCID: 2AX54-Z83II RF Exposure Measurement The limit for Maximum Permissible Exposure (MPE) specified in FCC 1.1310 is followed. The gain of the antennas used in the product is extracted from the Antenna data sheets provided and also the maximum total power input to the antenna is measured. Through the Friis transmission formula and the maximum gain of the antenna, we can calculate the distance, away from the product, where the limit of MPE is reached. Although the Friis Transmission formula is far field assumption, the calculated result of that is an over-prediction for near field power density. It is taken as worst case to specify the safety range. RF Exposure Limit According to FCC 1.1310: The criteria listed in the following table shall be used to evaluate the environmental impact of the human exposure to radio-frequency (RF) radiation as specified in 1.1307 (b) Limits for Maximum Permissible Exposure (MPE) F= Frequency in MHz Frequency Range (MHz) Electric Field Strength (V/m) Magnetic Field Strength (A/m) Power Density (mW/cm²) Limits for Occupational / controlled Exposures 300 - 1500 -- -- F/300 1500 – 100000 -- -- 5.0 Limits for General population / Uncontrolled Exposure 300 - 1500 -- -- F/1500 1500 – 100000 -- -- 1.0 Friss Formula Friss Transmission Formula: Pd= (Pout * G) / (4*pi*r²) Where Pd = power density in mW/cm² Pout = output power to antenna in mW G = gain of antenna in linear scale Pi = 3.1416 R = Distance between observation point and the center of radiator in cm If we know the maximum gain of the antenna and the total output power to the antenna, through calculation, we will know MPE value at distance 20cm. EUT Operation condition EUT was enabled to transmit and receive at lowest, middle and highest channels. Classification The antenna of this product, under normal use condition, is at least 20cm away from the body of the user. Warning statement to the user for keeping at least 20cm or more separation distance from the antenna should be included in the User manual. So, this device is classified as Mobile device. ANT Gain (G) Antenna gain: 1.44dBi (gain of antenna in linear scale=1.393) 2.4G WIFI Mode 802.11b/g/n20:2412-2462MHz 802.11n40:2422-2452MHz Detector AVG 802.11b 14±1dBm 802.11g 19±1dBm 802.11n20 18±1dBm 802.11n40 18±1dBm Protocol ANT Gain(gain of antenna in linear scale) Channel Frequency (MHz) Output Power to Antenna (dBm) Output Power to Antenna (mW) Power Density (mW/cm²) Limit (mW/cm²) 802.11b 1.393 2412 15 31.6228 0.008771 802.11g 1.393 2462 20 100.0000 0.027731 802.11n20 1.393 2462 19 79.4328 0.022021 802.11n40 1.393 2422 19 79.4328 0.022021 5G WIFI Antenna gain: 1.44dBi (gain of antenna in linear scale=1.393) Mode IEEE 802.11a/ n(HT20)/ac(VHT20): 5.180GHz-5.240GHz IEEE 802.11n(HT40)/ac(VHT40): 5.190GHz-5.230GHz Detector AVG IEEE 802.11a/ n(HT20)/ac(VHT20): 9±1dBm IEEE 802.11n(HT40)/ac(VHT40): 8±1dBm Protocol ANT Gain(gain of antenna in linear scale) Channel Frequenc y (MHz) Output Power to Antenna (dBm) Output Power to Antenna (mW) Power Density (mW/cm²) Limit (mW/cm²) 802.11a/n/ac(HT 20) 1.393 5180 10 10.0000 0.00277 1 802.11a/n/ac(HT 40) 1.393 5190 9 7.9433 0.00220 1 5G WIFI Antenna gain: 1.44dBi (gain of antenna in linear scale=1.393) Mode IEEE 802.11a/ n/ac(HT20) 5.260GHz-5.300GHz IEEE 802.11n/ac(HT40) 5.270GHz-5.310GHz Detector AVG IEEE 802.11a/ n(HT20)/ac(VHT20): 8.5±1dBm IEEE 802.11n(HT40)/ac(VHT40): 7±1dBm Protocol ANT Gain(gain of antenna in linear scale) Channel Frequency (MHz) Output Power to Antenna (dBm) Output Power to Antenna (mW) Power Density (mW/cm²) Limit (mW/cm²) 802.11a/n/ac(HT 20) 1.393 5260 9.5 8.9125 0.00247 1 802.11a/n/ac(HT 40) 1.393 5270 8 6.3096 0.00175 1 5G WIFI Antenna gain: 1.44dBi (gain of antenna in linear scale=1.393) ANT Gain (G) Protocol ANT Gain(gain of antenna in linear scale) Channel Frequency (MHz) Output Power to Antenna (dBm) Output Power to Antenna (mW) Power Density (mW/cm²) Limit (mW/cm²) 802.11a/n/ac(HT 20) 1.393 5580 9.5 8.9125 0.00247 1 802.11a/n/ac(HT 40) 1.393 5670 8 6.3096 0.00175 1 Mode IEEE 802.11a/ n/ac(HT20) 5.500GHz-5.700GHz IEEE 802.11n/ac(HT40) 5.510GHz-5.6700GHz Detector AVG IEEE 802.11a/ n(HT20)/ac(VHT20): 8.5±1dBm IEEE 802.11n(HT40)/ac(VHT40): 8±1dBm 5G WIFI ANT Gain (G) Mode IEEE 802.11a/ n/ac(HT20) 5.745GHz-5.825GHz IEEE 802.11n/ac(HT40) 5.755GHz-5.795GHz Detector AVG IEEE 802.11a/ n(HT20)/ac(VHT20): 8.5±1dBm IEEE 802.11n(HT40)/ac(VHT40 ): 8±1dBm Antenna gain: 1.44dBi (gain of antenna in linear scale=1.393) Protocol ANT Gain(gain of antenna in linear scale) Channel Frequency (MHz) Output Power to Antenna (dBm) Output Power to Antenna (mW) Power Density (mW/cm²) Limit (mW/cm²) 802.11a/n/ac(HT 20) 1.393 5825 9.5 8.9125 0.00247 1 802.11a/n/ac(HT 40) 1.393 5755 9 7.9433 0.00220 1 According to the maximum gain of the antenna and the total output power to the antenna, through calculation, we will know max MPE value 0.02773 at distance 20cm. This is less than the limit 1.So SAR testing is not required.

Test Report

FCC Test Report Report No: FCS202011056W02 Issued for Applicant: Guangzhou Cal-Boz Electrical Science &Technology Co., Ltd Address: Building A-1, No.4 Weiwu Road, Zengjiang Street, Zengcheng District, Guangzhou City,Guangdong Province, China Product Name: Mini computer Brand Name: NA Model Name: Z83II Series Model: NA FCC ID: 2AX54-Z83II Issued By: Flux Compliance Service Laboratory Add: Room 105 Floor Bao hao Technology Building 1 NO.15 Gong ye West Road Hi-Tech Industrial, Song shan lake Dongguan Tel: 769-27280901 Fax:769-27280901 http://www.FCS-lab.com Page 2 of 86 Report No.: FCS202011056W02 Flux Compliance Service Laboratory Room 105 Floor Bao hao Technology Building 1 NO.15 Gong ye West Road Hi-Tech Industrial, Song shan lake Dongguan Tel: 769-27280901 Fax:769-27280901 http://www.FCS-lab.com TEST RESULT CERTIFICATION Applicant’s Name ................... : Guangzhou Cal-Boz Electrical Science &Technology Co., Ltd Address .................................. : Building A-1, No.4 Weiwu Road, Zengjiang Street, Zengcheng District, Guangzhou City,Guangdong Province, China Manufacture's Name .............. : Guangzhou Cal-Boz Electrical Science &Technology Co., Ltd Address .................................. : Building A-1, No.4 Weiwu Road, Zengjiang Street, Zengcheng District, Guangzhou City,Guangdong Province, China Product Description Product Name ........................ : Mini computer Model Name ........................... : Z83II Series Model .......................... : N/A Te s t Standards ....................... : CFR 47 FCC Part15E section 15.407 Te s t Procedure ....................... : ANSI C63.10-2013 KDB 789033 D02 General U-NII Test Procedures New Rules v02r01 This device described above has been tested by Flux Compliance Service Laboratory, the test results show that the equipment under test (EUT) is in compliance with the FCC requirements. And it is applicable only to the tested sample identified in the report. This report shall not be reproduced except in full, without the written approval of Flux Compliance Service Laboratory, this document may be altered or revised by Flux Compliance Service Laboratory, personal only, and shall be noted in the revision of the document.. Date of Test .............................. : Date (s) of performance of tests : 05 Nov, 2020 ~ 19 Nov, 2020 Date of Issue ............................. : 20 Nov, 2020 Test Result ................................. : Pass Tested by : (Scott Shen) Reviewed by : (Duke Qian) Approved by : (Kait Chen) Page 3 of 86 Report No.: FCS202011056W02 Flux Compliance Service Laboratory Room 105 Floor Bao hao Technology Building 1 NO.15 Gong ye West Road Hi-Tech Industrial, Song shan lake Dongguan Tel: 769-27280901 Fax:769-27280901 http://www.FCS-lab.com Table of Contents Page 1. SUMMARY OF TEST RESULTS 6 1.1 TEST FACTORY 7 1.2 MEASUREMENT UNCERTAINTY 7 2. GENERAL INFORMATION 8 2.1 GENERAL DESCRIPTION OF THE EUT 8 2.2 BLOCK DIGRAM SHOWING THE CONFIGURATION OF SYSTEM TESTED 11 2.3 DESCRIPTION OF NECESSARY ACCESSORIES AND SUPPORT UNITS 11 2.4 EQUIPMENTS LIST 12 3. 26DB BANDWIDTH, 6DB BANDWIDTH AND 99% BANDWIDTH 13 3.1 LIMIT 13 3.2 TEST PROCEDURE 13 3.3 TEST SETUP 13 3.4 TEST RESULTS 14 3.5 ORIGINAL TEST DATA 17 4. CONDUCTED OUTPUT POWER 29 4.1 LIMIT 29 4.2 TEST PROCEDURE 29 4.3 TEST SETUP 29 4.4 TEST RESULTS 30 5. POWER SPECTRAL DENSITY 34 5.1 LIMIT 34 5.2 TEST PROCEDURE 34 5.3 TEST SETUP 35 6. DUTY CYCLE 50 6.1 TEST REQUIREMENT 50 6.2 TEST PROCEDURE 50 6.3 TEST SETUP 50 6.4 TEST RESULTS 51 7. RADIATED EMISSION MEASUREMENT 52 7.1 RADIATED EMISSION LIMITS 52 Page 4 of 86 Report No.: FCS202011056W02 Flux Compliance Service Laboratory Room 105 Floor Bao hao Technology Building 1 NO.15 Gong ye West Road Hi-Tech Industrial, Song shan lake Dongguan Tel: 769-27280901 Fax:769-27280901 http://www.FCS-lab.com Table of Contents Page 7.2 TEST PROCEDURE 53 7.3 TESTSETUP 54 7.4 RADIATED EMISSION TEST RESULTS 56 7.5 BANDEDGE TEST RESULT 66 8. CONDUCTED SPURIOUS EMISSIONS AND BANDEDGE 74 8.1 LIMIT 74 8.2 TEST PROCEDURE 74 8.3 TEST SETUP 75 8.4 TEST RESULTS 75 9. CONDUCTED EMISSION TEST 76 10. ANTENNA REQUIREMENT 80 10.1 STANDARD REQUIREMENT 80 10.2 RESULT 80 Page 5 of 86 Report No.: FCS202011056W02 Flux Compliance Service Laboratory Room 105 Floor Bao hao Technology Building 1 NO.15 Gong ye West Road Hi-Tech Industrial, Song shan lake Dongguan Tel: 769-27280901 Fax:769-27280901 http://www.FCS-lab.com Revision History Rev. Issue Date Report NO. Effect Page Contents 00 20 Nov, 2020 FCS202011056W02 ALL Initial Issue Page 6 of 86 Report No.: FCS202011056W02 Flux Compliance Service Laboratory Room 105 Floor Bao hao Technology Building 1 NO.15 Gong ye West Road Hi-Tech Industrial, Song shan lake Dongguan Tel: 769-27280901 Fax:769-27280901 http://www.FCS-lab.com 1. SUMMARY OF TEST RESULTS Test procedures according to the technical standards: Test procedures according to the technical standards: § 15.407,KDB 789033 D02 General U-NII Test Procedures New Rules v02r01 Standard Section Test Item Judgment Remark FCC 15.407 (a) FCC 15.407 (e) 6/26db Bandwidth and 99% Bandwidth PASS -- FCC 15.407 (a) Maximum Conducted Output Power PASS -- FCC 15.407 (a) Power Spectral Density PASS -- FCC 15.407 (g) Frequency Stability Measurement PASS FCC 15.407 (b) FCC 15.209 FCC 15.205 Emissions in restricted frequency bands PASS FCC 15.407 (b) FCC 15.209 FCC 15.205 Band Edge Compliance PASS FCC 15.207 Power Line Conducted Emission PASS FCC 15.203 Antenna requirement PASS -- Page 7 of 86 Report No.: FCS202011056W02 Flux Compliance Service Laboratory Room 105 Floor Bao hao Technology Building 1 NO.15 Gong ye West Road Hi-Tech Industrial, Song shan lake Dongguan Tel: 769-27280901 Fax:769-27280901 http://www.FCS-lab.com 1.1 TEST FACTORY Company Name: Flux Compliance Service Laboratory Address: Room 105 Floor Bao hao Technology Building 1 NO.15 Gong ye West Road Hi-Tech Industrial, Song shan lake Dongguan Telephone: +86-769-27280901 Fax: +86-769-27280901 FCC Test Firm Re…

Text truncated - open the document above for the full version.

Test Report

TR Conducted Spurious&Band edge The frequency emission of peak points that did not show above the forms are at least 20dB below the limit, the frequency emission is mainly from the environment noise. WLAN_Band-1 WLAN_Band-1 W52_11a20_Lower_Conducted Spurious W52_11a20_Middle_Conducted Spurious W52_11a20_Higher_Conducted Spurious W52_11a20_Lower_Band edge W52_11a20_Higher_Band edge W52_11n20_Lower_Conducted Spurious WLAN_Band-1 WLAN_Band-1 W52_11n20_Middle_Conducted Spurious W52_11n20_Higher_Conducted Spurious W52_11n20_Lower_Band edge W52_11n20_Higher_Band edge W52_11n40_Lower_Conducted Spurious W52_11n40_Higher_Conducted Spurious WLAN_Band-1 WLAN_Band-1 W52_11n40_Lower_Band edge W52_11n40_Higher_Band edge W52_11ac20_Lower_Conducted Spurious W52_11ac20_Middle_Conducted Spurious W52_11ac20_Higher_Conducted Spurious W52_11ac20_Lower_Band edge WLAN_Band-1 WLAN_Band-1 W52_11ac20_Higher_Band edge W52_11ac40_Lower_Conducted Spurious W52_11ac40_Higher_Conducted Spurious W52_11ac40_Lower_Band edge W52_11ac40_Higher_Band edge WLAN_Band-2 WLAN_Band-2 W53_11a20_Lower_Conducted Spurious W53_11a20_Middle_Conducted Spurious W53_11a20_Higher_Conducted Spurious W53_11a20_Lower_Band edge W53_11a20_Higher_Band edge W53_11n20_Lower_Conducted Spurious WLAN_Band-2 WLAN_Band-2 W53_11n20_Middle_Conducted Spurious W53_11n20_Higher_Conducted Spurious W53_11n20_Lower_Band edge W53_11n20_Higher_Band edge W53_11n40_Lower_Conducted Spurious W53_11n40_Higher_Conducted Spurious WLAN_Band-2 WLAN_Band-2 W53_11n40_Lower_Band edge W53_11n40_Higher_Band edge W53_11ac20_Lower_Conducted Spurious W53_11ac20_Middle_Conducted Spurious W53_11ac20_Higher_Conducted Spurious W53_11ac20_Lower_Band edge WLAN_Band-2 WLAN_Band-2 W53_11ac20_Higher_Band edge W53_11ac40_Lower_Conducted Spurious W53_11ac40_Higher_Conducted Spurious W53_11ac40_Lower_Band edge W53_11ac40_Higher_Band edge WLAN_Band-3 WLAN_Band-3 W56_11a20_Lower_Conducted Spurious W56_11a20_Middle_Conducted Spurious W56_11a20_Higher_Conducted Spurious W56_11a20_Lower_Band edge W56_11a20_Higher_Band edge W56_11n20_Lower_Conducted Spurious WLAN_Band-3 WLAN_Band-3 W56_11n20_Middle_Conducted Spurious W56_11n20_Higher_Conducted Spurious W56_11n20_Lower_Band edge W56_11n20_Higher_Band edge W56_11n40_Lower_Conducted Spurious W56_11n40_Middle_Conducted Spurious WLAN_Band-3 WLAN_Band-3 W56_11n40_Higher_Conducted Spurious W56_11n40_Lower_Band edge W56_11n40_Higher_Band edge W56_11ac20_Lower_Conducted Spurious W56_11ac20_Middle_Conducted Spurious W56_11ac20_Higher_Conducted Spurious WLAN_Band-3 WLAN_Band-3 W56_11ac20_Lower_Band edge W56_11ac20_Higher_Band edge W56_11ac40_Lower_Conducted Spurious W56_11ac40_Middle_Conducted Spurious W56_11ac40_Higher_Conducted Spurious W56_11ac40_Lower_Band edge WLAN_Band-3 WLAN_Band-3 W56_11ac40_Higher_Band edge WLAN_Band-4 WLAN_Band-4 W58_11a20_Lower_Conducted Spurious W58_11a20_Middle_Conducted Spurious W58_11a20_Higher_Conducted Spurious W58_11a20_Lower_Band edge W58_11a20_Higher_Band edge W58_11n20_Lower_Conducted Spurious WLAN_Band-4 WLAN_Band-4 W58_11n20_Middle_Conducted Spurious W58_11n20_Higher_Conducted Spurious W58_11n20_Lower_Band edge W58_11n20_Higher_Band edge W58_11n40_Lower_Conducted Spurious W58_11n40_Higher_Conducted Spurious WLAN_Band-4 WLAN_Band-4 W58_11n40_Lower_Band edge W58_11n40_Higher_Band edge W58_11ac20_Lower_Conducted Spurious W58_11ac20_Middle_Conducted Spurious W58_11ac20_Higher_Conducted Spurious W58_11ac20_Lower_Band edge WLAN_Band-4 WLAN_Band-4 W58_11ac20_Higher_Band edge W58_11ac40_Lower_Conducted Spurious W58_11ac40_Higher_Conducted Spurious W58_11ac40_Lower_Band edge W58_11ac40_Higher_Band edge

Test Report

FCC Test Report Report No: FCS202011056W03 Issued for Applicant: Guangzhou Cal-Boz Electrical Science &Technology Co., Ltd Address: Building A-1, No.4 Weiwu Road, Zengjiang Street, Zengcheng District, Guangzhou City,Guangdong Province, China Product Name: Mini computer Brand Name: NA Model Name: Z83II Series Model: NA FCC ID: 2AX54-Z83II Issued By: Flux Compliance Service Laboratory Add: Room 105 Floor Bao hao Technology Building 1 NO.15 Gong ye West Road Hi-Tech Industrial, Song shan lake Dongguan Tel: 769-27280901 Fax:769-27280901 http://www.FCS-lab.com Page 2 of 26 Report No.: FCS202011056W03 Flux Compliance Service Laboratory Room 105 Floor Bao hao Technology Building 1 NO.15 Gong ye West Road Hi-Tech Industrial, Song shan lake Dongguan Tel: 769-27280901 Fax:769-27280901 http://www.FCS-lab.com TEST RESULT CERTIFICATION Applicant’s Name ................... : Guangzhou Cal-Boz Electrical Science &Technology Co., Ltd Address .................................. : Building A-1, No.4 Weiwu Road, Zengjiang Street, Zengcheng District, Guangzhou City,Guangdong Province, China Manufacture's Name .............. : Guangzhou Cal-Boz Electrical Science &Technology Co., Ltd Address .................................. : Building A-1, No.4 Weiwu Road, Zengjiang Street, Zengcheng District, Guangzhou City,Guangdong Province, China Product Description Product Name ........................ : Mini computer Model Name ........................... : Z83II Series Model .......................... : N/A Test Standards ....................... : FCC Part 15.407 Te s t Procedure ....................... : 905462 D02 UNII DFS Compliance Procedures New Rules v02 905462 D03 UNII Clients Without Radar Detection New Rules This device described above has been tested by Flux Compliance Service Laboratory, the test results show that the equipment under test (EUT) is in compliance with the FCC requirements. And it is applicable only to the tested sample identified in the report. This report shall not be reproduced except in full, without the written approval of Flux Compliance Service Laboratory, this document may be altered or revised by Flux Compliance Service Laboratory, personal only, and shall be noted in the revision of the document.. Date of Test .............................. : Date (s) of performance of tests : 05 Nov, 2020 ~ 19 Nov, 2020 Date of Issue ............................. : 20 Nov, 2020 Test Result ................................. : Pass Tested by : (Chris Chen) Reviewed by : (Jack Chen) Approved by : ( Andy yue) Page 3 of 26 Report No.: FCS202011056W03 Flux Compliance Service Laboratory Room 105 Floor Bao hao Technology Building 1 NO.15 Gong ye West Road Hi-Tech Industrial, Song shan lake Dongguan Tel: 769-27280901 Fax:769-27280901 http://www.FCS-lab.com Table of Contents Page 1. SUMMARY OF TEST RESULTS 5 1.1 TEST FACTORY 6 1.2 MEASUREMENT UNCERTAINTY 6 2. GENERAL INFORMATION 7 2.1 GENERAL DESCRIPTION OF THE EUT 7 2.2 TEST CONDITIONS AND CHANNEL 9 2.3 EQUIPMENTS LIST 10 3. DFS PARAMETERS 11 3.1 DFS PARAMETERS 11 3.2 DFS –TEST RESULTS 15 Page 4 of 26 Report No.: FCS202011056W03 Flux Compliance Service Laboratory Room 105 Floor Bao hao Technology Building 1 NO.15 Gong ye West Road Hi-Tech Industrial, Song shan lake Dongguan Tel: 769-27280901 Fax:769-27280901 http://www.FCS-lab.com Revision History Rev. Issue Date Effect Page Contents 00 20 Nov, 2020 All Initial Issue Page 5 of 26 Report No.: FCS202011056W03 Flux Compliance Service Laboratory Room 105 Floor Bao hao Technology Building 1 NO.15 Gong ye West Road Hi-Tech Industrial, Song shan lake Dongguan Tel: 769-27280901 Fax:769-27280901 http://www.FCS-lab.com 1. SUMMARY OF TEST RESULTS Test procedures according to the technical standards: KDB 905462 D02 UNII DFS Compliance Procedures New Rules v02 and 905462 D03 UNII Clients Without Radar Detection New Rules v01r02 Part 15.407 Requirement Operational Mode RESULTS Master Client Non-Occupancy Period N/A Ye s Pass DFS Detection Threshold N/A Not required Not required Channel Availability Check Time N/A Not required Not required Channel Closing Transmission Time N/A Ye s Pass Channel Move Time N/A Ye s Pass U-NII Detection Bandwidth N/A Not required Not required Page 6 of 26 Report No.: FCS202011056W03 Flux Compliance Service Laboratory Room 105 Floor Bao hao Technology Building 1 NO.15 Gong ye West Road Hi-Tech Industrial, Song shan lake Dongguan Tel: 769-27280901 Fax:769-27280901 http://www.FCS-lab.com 1.1 TEST FACTORY Company Name: Flux Compliance Service Laboratory Address: Room 105 Floor Bao hao Technology Building 1 NO.15 Gong ye West Road Hi-Tech Industrial, Song shan lake Dongguan Telephone: +86-769-27280901 Fax: +86-769-27280901 FCC Test Firm Registration Number: 514908 Designation number: CN0127 A2LA accreditation number:5545.01 1.2 MEASUREMENT UNCERTAINTY The reported uncertainty of measurement y ±U, where expended uncertainty U is based on a standard uncertainty multiplied by a coverage factor of k=2, providing a level of confidence of approximately 95 %. No. Item Uncertainty 1 RF output power, conducted ±0.71dB 2 Unwanted Emissions, conducted ±2.988 dB 3 Conducted Emission (9KHz-150KHz) ±4.13 dB 4 Conducted Emission (150KHz-30MHz) ±4.74 dB 5 All emissions,radiated(<1G) 30MHz-1000MHz ±5.2 dB 6 All emissions,radiated 1GHz -18GHz ±4.66 dB 7 All emissions,radiated 18GHz -40GHz ±4.31 dB Page 7 of 26 Report No.: FCS202011056W03 Flux Compliance Service Laboratory Room 105 Floor Bao hao Technology Building 1 NO.15 Gong ye West Road Hi-Tech Industrial, Song shan lake Dongguan Tel: 769-27280901 Fax:769-27280901 http://www.FCS-lab.com 2. GENERAL INFORMATION 2.1 GENERAL DESCRIPTION OF THE EUT Product Name Mini computer Trade Name NA Model Name Z83II Series Model N/A Model Difference N/A Channel List Please refer to the Note 2. Operation frequency 802.11a/ 802.11ac20/ 802.11n(HT20): 5260-5230MHz 802.11ac40/ 802.11n(HT40): 5270-5310MHz, Modulation: IIEEE 802.11a/n :OFDM(64QAM, 16QAM, QPSK, BPSK) IEEE 802.11ac :O…

Text truncated - open the document above for the full version.

Test Setup Photos

Radiated emission Conducted emission

Contact Information

Applicant

wang lei
[email protected]15323448796Fax: 15323448796

Technical Contact

Guangzhou Cal-Boz Electrical Science &Technology C
[email protected]

China

Test Firm

Flux Compliance Service LaboratoryAndy Yue
[email protected]13510297284

Technical Specifications

#Rule PartsFrequency RangePower Output
415E5.75 GHz - 5.83 GHz9.00 mW
Confidentiality
Long Term
Grant Notes
Output power listed is conducted power. This device contains 20 and 40 MHz signal bandwidth. The antenna used with this transmitter must be installed to provide a minimum separation distance of at least 20 cm from all persons and must not be co-located or operating in conjunction with any other antenna or transmitter, except in accordance with FCC multi- transmitter product procedures. End-users must be provided with operating procedures for satisfying RF exposure compliance.