Andritz AG
Wireles BLE Condition Monitoring Sensor recording vibration and temperature - FCC ID 2AX58METRISVIBEPRO - Andritz AG
Click to zoom

Application Details

Equipment Class
DTS - Digital Transmission System
Date of Grant
Mar 24, 2026
Application Purpose
Original Equipment
Equipment Note
Wireles BLE Condition Monitoring Sensor recording vibration and temperature
Frequency Range
2402.00000000 - 2480.00000000
Company
Andritz AG
Country
Austria

Documents & Files

Select a file to view

Users Manual

↗

Attestation Statements

↗
↗

Cover Letter(s)

↗

External Photos

↗

ID Label/Location Info

↗

Internal Photos

↗

RF Exposure Info

↗

Test Report

↗
↗
↗

Test Setup Photos

↗

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

Users Manual

ANDRITZ AG Stattegger Strasse 18 8045 Graz, Austria Phone: +43 (316) 6902 0 Fax: +43 (316) 6902 415 www.andritz.com Legal form: Corporation Company seat: Graz, Court of registry: Landes- und Handelsgericht Graz Company reg. no.: FN 50935 f, DVR: 005 0008, ARA license no.: 7485 VAT (UID): ATU28609707 Bank account: UniCredit Bank Austria AG Bank code: 12000 A/c no.: 00874716400 IBAN: +43 (1100) 0008 74716400 BIC (SWIFT): BKAUATWW Operating Manual Metris Vibe Pro Ex Revision: 09 07 07.11.2024 Operating Manual CSP Draft ! 08 13.02.2025 Operating Manual CSP Draft ! 09 13.1.2026 Operating Manual CSP Operating manual: Metris Vibe Pro Rev.: 09 ANDRITZ Page 2 of 26 February 13, 2025 Table of Contents Abbreviations ......................................................................................................................................... 3 Preface .................................................................................................................................................... 4 Information on the manufacturer ......................................................................................................... 5 1 Introduction .................................................................................................................................... 6 1.1 About this manual .................................................................................................................... 6 1.2 Warranty and liability ................................................................................................................ 6 1.3 Copyright .................................................................................................................................. 7 1.4 Intended use ............................................................................................................................ 7 1.5 Notice of claims ........................................................................................................................ 7 1.6 Shipping ................................................................................................................................... 8 1.7 Storage ..................................................................................................................................... 8 1.7.1 Incoming inspection ................................................................................................................. 8 1.7.2 Packaging ................................................................................................................................ 9 1.7.3 Storage ................................................................................................................................... 10 2 Safety ............................................................................................................................................ 13 2.1 Safety instructions .................................................................................................................. 13 2.2 Basic safety instructions......................................................................................................... 13 3. Metris Vibe Sensor Start Up ....................................................................................................... 15 3.1 Activating the Metris Vibe Pro from Storage mode ................................................................ 15 3.2 Installation instruction ............................................................................................................. 15 3.3 Downloading data .................................................................................................................. 16 3.4 Settings METRIS VIBE PRO sensor ...................................................................................... 16 3.5 Special conditions .................................................................................................................. 17 4. Repair ............................................................................................................................................ 17 5. Battery replacement .................................................................................................................... 17 6. Installation requirements in explosive zones ........................................................................... 18 7. Decommissioning ........................................................................................................................ 18 7.1 Disposal ................................................................................................................................. 18 8. Area of Application ...................................................................................................................... 20 9. Technical data and ambient conditions .................................................................................... 21 10. Outline Drawing ........................................................................................................................... 22 11. RESERVED FOR DECLARATION OF CONFORMITY ................................................................ 23 Place/Date: Graz, February 13, 2025 .................................................................................................. 23 12. FCC and ISED information .......................................................................................................... 24 12.1 Class B digital device .............................................................................................................. 24 12.2 RF Exposure Information according 2.1091 / 2.1093 / KDB 447498 / RSS-102 ................... 25 Operating manual: Metris Vibe Pro Rev.: 09 ANDRITZ Page 3 of 26 February 13, 2025 12.3 Used frequence range, used modes and antena information ................................................ 25 12.4 FCC ID .................................…

Text truncated - open the document above for the full version.

Attestation Statements

ANDRITZ AG Ú Stattegger Strasse 18 Ú 8045 Graz Ú Austria Ú p: +43 316 6902-0 Ú [email protected] Ú andritz.com Legal form: Corporation Ú Company seat: Graz Ú Court of registry: Landes- und Handelsgericht Graz Ú Company reg. no: FN 50935 f DVR. 005 0008 Ú ARA-licence-no: 7485 Ú VAT (UID): ATU28609707 Ú Bank account: UniCredit Bank Austria AG Bank code: 11000 Ú Acc.no.: 00874716400 Ú IBAN: AT08 1100 0008 7471 6400 Ú BIC (SWIFT): BKAUATWW Andritz AG Statteggerstrasse 18 A-8045 Graz Austria Federal Communication Commission Authorization and Evaluation Division 7435 Oakland Mills Road Columbia, MD 21046 USA 03/25/2025 Attestation Statement according to 2.911(d)(5)(i) and 2.911(d)(5)(ii) FCC ID: 2AX58METRISVIBEPRO TO WHOM IT MAY CONCERN: Hereby we certify that the equipment for which authorization is sought is not “covered” equipment prohibited from receiving an equipment authorization pursuant to section 2.903 of the FCC rules. Further we certify that, as of the date of the filing of the application, Andritz AG is not identified on the Covered List as an entity producing “covered” equipment. Page: 2 (total 2) Sincerely, (signature & company stamp) Andritz AG 0036783470 Statteggerstrasse 18 A-8045 Graz Austria Christoph Spielmann +43 316 6902 2886 [email protected]

Attestation Statements

ANDRITZ AG Ú Stattegger Strasse 18 Ú 8045 Graz Ú Austria Ú p: +43 316 6902-0 Ú [email protected] Ú andritz.com Legal form: Corporation Ú Company seat: Graz Ú Court of registry: Landes- und Handelsgericht Graz Ú Company reg. no: FN 50935 f DVR. 005 0008 Ú ARA-licence-no: 7485 Ú VAT (UID): ATU28609707 Ú Bank account: UniCredit Bank Austria AG Bank code: 11000 Ú Acc.no.: 00874716400 Ú IBAN: AT08 1100 0008 7471 6400 Ú BIC (SWIFT): BKAUATWW Andritz AG Statteggerstrasse 18 A-8045 Graz Austria Federal Communication Commission Authorization and Evaluation Division 7435 Oakland Mills Road Columbia, MD 21046 USA 03/25/2025 Attestation Statement according to 2.911(d)(7) FCC ID: 2AX58METRISVIBEPRO TO WHOM IT MAY CONCERN: We, Andritz AG designate ANDRITZ Inc., to act as U.S. agent for service of process. ANDRITZ Inc. hereby acknowledges the obligation of the U.S. agent for service of process. Further Andritz AG accepts to maintain an agent for no less than one year after the grantee has terminated all marketing and importation or the conclusion of any Commission-related proceeding involving the equipment. Page: 2 (total 2) Sincerely (signature & company stamp) Andritz AG 0036783470 Statteggerstrasse 18 A-8045 Graz Austria Christoph Spielmann +43 316 6902 2886 [email protected] (signature & company stamp) ANDRITZ Inc. 0036667590 13560 Morris Road, Suite 1250 Alpharetta Georgia 30004 United States of America Tanaji Mali Telephone No: +1 404 807 8528 Email: [email protected]

Cover Letter(s)

CONFIDENTIALITY REQUEST for Certification Service in USA Federal Communication Commission Equipment Authorization Division, Application Processing Branch 7435 Oakland Mills Road Columbia, MD 21048 <2025-03-25> TO WHOM IT MAY CONCERN Pursuant to Paragraphs §0.457 and 0.459 of the Commission’s Rules (47 C.F.R.) and Section §552(b) (4) of the Freedom of Information Act, we requests confidentiality for the following products: FCC ID 2AX58METRISVIBEPRO Model name METRISVIBEPRO For the product stated above, we request that the following information be held confidential; Exhibits Long-Term Confidentiality Short-Term Confidentiality External Photos Internal Photos Block Diagram Schematics Test Setup Photos User’s Manual Parts List Tune Up Operational Description The long-term confidentiality exhibits contain our trade secrets and proprietary information that could be of benefit to our competitors. The short-term confidentiality on the basis of ensuring that business sensitive information remains confidential until the actual marketing of our new device, which is planned for 09/01/2025 If you have any questions, please feel free to contact me at the address shown below. Sincerely, (Signed) Name / Title: Christoph Spielmann Company: Andritz AG Address: Statteggerstrasse 18. A-8045 Graz, Austria Phone: +43 316 6902 2886 Fax: E-Mail: [email protected]

External Photos

ANDRITZ AG Ú Stattegger Strasse 18 Ú 8045 Graz Ú Austria Ú p: +43 316 6902-0 Ú [email protected] Ú andritz.com Legal form: Corporation Ú Company seat: Graz Ú Court of registry: Landes- und Handelsgericht Graz Ú Company reg. no: FN 50935 f DVR. 005 0008 Ú ARA-licence-no: 7485 Ú VAT (UID): ATU28609707 Ú Bank account: UniCredit Bank Austria AG Bank code: 11000 Ú Acc.no.: 00874716400 Ú IBAN: AT08 1100 0008 7471 6400 Ú BIC (SWIFT): BKAUATWW External Photos MetrisVibePro Christoph Spielmann 01/28/2025 ANDRITZ AG Ú Stattegger Strasse 18 Ú 8045 Graz Ú Austria Ú p: +43 316 6902-0 Ú [email protected] Ú andr itz.com Legal form: Corporation Ú Company seat: Graz Ú Court of registry: Landes- und Handelsgericht Graz Ú Company reg. no: FN 50935 f DVR. 005 0008 Ú ARA-licence-no: 7485 Ú VAT (UID): ATU28609707 Ú Bank account: UniCredit Bank Austria AG Bank code: 11000 Ú Acc.no.: 00874716400 Ú IBAN: AT08 1100 0008 7471 6400 Ú BIC (SWIFT): BKAUATWW Page: 2 (total 5) ANDRITZ AG Ú Stattegger Strasse 18 Ú 8045 Graz Ú Austria Ú p: +43 316 6902-0 Ú [email protected] Ú andr itz.com Legal form: Corporation Ú Company seat: Graz Ú Court of registry: Landes- und Handelsgericht Graz Ú Company reg. no: FN 50935 f DVR. 005 0008 Ú ARA-licence-no: 7485 Ú VAT (UID): ATU28609707 Ú Bank account: UniCredit Bank Austria AG Bank code: 11000 Ú Acc.no.: 00874716400 Ú IBAN: AT08 1100 0008 7471 6400 Ú BIC (SWIFT): BKAUATWW Page: 3 (total 5) ANDRITZ AG Ú Stattegger Strasse 18 Ú 8045 Graz Ú Austria Ú p: +43 316 6902-0 Ú [email protected] Ú andr itz.com Legal form: Corporation Ú Company seat: Graz Ú Court of registry: Landes- und Handelsgericht Graz Ú Company reg. no: FN 50935 f DVR. 005 0008 Ú ARA-licence-no: 7485 Ú VAT (UID): ATU28609707 Ú Bank account: UniCredit Bank Austria AG Bank code: 11000 Ú Acc.no.: 00874716400 Ú IBAN: AT08 1100 0008 7471 6400 Ú BIC (SWIFT): BKAUATWW Page: 4 (total 5) ANDRITZ AG Ú Stattegger Strasse 18 Ú 8045 Graz Ú Austria Ú p: +43 316 6902-0 Ú [email protected] Ú andr itz.com Legal form: Corporation Ú Company seat: Graz Ú Court of registry: Landes- und Handelsgericht Graz Ú Company reg. no: FN 50935 f DVR. 005 0008 Ú ARA-licence-no: 7485 Ú VAT (UID): ATU28609707 Ú Bank account: UniCredit Bank Austria AG Bank code: 11000 Ú Acc.no.: 00874716400 Ú IBAN: AT08 1100 0008 7471 6400 Ú BIC (SWIFT): BKAUATWW Page: 5 (total 5)

Internal Photos

ANDRITZ AG Ú Stattegger Strasse 18 Ú 8045 Graz Ú Austria Ú p: +43 316 6902-0 Ú [email protected] Ú andritz.com Legal form: Corporation Ú Company seat: Graz Ú Court of registry: Landes- und Handelsgericht Graz Ú Company reg. no: FN 50935 f DVR. 005 0008 Ú ARA-licence-no: 7485 Ú VAT (UID): ATU28609707 Ú Bank account: UniCredit Bank Austria AG Bank code: 11000 Ú Acc.no.: 00874716400 Ú IBAN: AT08 1100 0008 7471 6400 Ú BIC (SWIFT): BKAUATWW Internal Photos MetrisVibePro Christoph Spielmann 01/28/2026 o ANDRITZ AG Ú Stattegger Strasse 18 Ú 8045 Graz Ú Austria Ú p: +43 316 6902-0 Ú [email protected] Ú andritz.com Legal form: Corporation Ú Company seat: Graz Ú Court of registry: Landes- und Handelsgericht Graz Ú Company reg. no: FN 50935 f DVR. 005 0008 Ú ARA-licence-no: 7485 Ú VAT (UID): ATU28609707 Ú Bank account: UniCredit Bank Austria AG Bank code: 11000 Ú Acc.no.: 00874716400 Ú IBAN: AT08 1100 0008 7471 6400 Ú BIC (SWIFT): BKAUATWW Page: 2 (total 2)

RF Exposure Info

© cetecom advanced GmbH Page 1 of 12 TEST REPORT Test report no.: 1-7035-23-01-03_TR1-R01 RF Exposure consideration according to FCC447498D04 V1 Testing laboratory Applicant cetecom advanced GmbH Untertuerkheimer Strasse 6 – 10 66117 Saarbruecken / Germany Phone: + 49 681 5 98 - 0 Fax: + 49 681 5 98 - 9075 Internet: https://cetecomadvanced.com e-mail: [email protected] Accredited Testing Laboratory: The testing laboratory (area of testing) is accredited according to DIN EN ISO/IEC 17025 (2018-03) by the Deutsche Akkreditierungsstelle GmbH (DAkkS). The accreditation is valid for the scope of testing procedures as stated in the accreditation certificate with the registration number: D-PL-12047-01-00. ISED Testing Laboratory Recognized Listing Number: DE0001 FCC designation number: DE0002 ANDRITZ AG Stattegger Strasse 18 8045 Graz / AUSTRIA Phone: +43 316 6902 0 Contact: Patrick Leuk e-mail: [email protected] Manufacturer ANDRITZ AG Stattegger Strasse 18 8045 Graz / AUSTRIA Test Item Kind of test item: Condition Monitoring Sensor for vibration and temperature Model name: MetrisVibe Pro FCC ID: 2AX58METRISVIBEPRO Frequency: 2400 MHz to 2483.5 MHz Technology: Bluetooth® LE This test report is electronically signed and valid without handwritten signature. For verification of the electronic signatures, the public keys can be requested at the testing laboratory. Test report authorized: Test performed: Alexander Hnatovskiy Eric Tuettmann Lab Manager Testing Manager Radio Labs Radio Labs Test report no.: 1-7035-23-01-03_TR1-R01 © cetecom advanced GmbH Page 2 of 12 1 Table of contents 1 Table of contents ............................................................................................................................................. 2 2 General Information ......................................................................................................................................... 3 2.1 Notes and Disclaimer ............................................................................................................................ 3 2.2 References ............................................................................................................................................ 3 2.3 Structure of this Document ................................................................................................................... 3 3 General RF Exposure Test Exemptions ............................................................................................................ 4 3.1 1 mW Test Exemption ........................................................................................................................... 5 3.2 MPE-Based Test Exemption ................................................................................................................. 5 3.3 SAR-Based Test Exemption .................................................................................................................. 5 3.4 Simultaneous Transmission ............................................................................................................... 6 4 1 mW Test Exemption ...................................................................................................................................... 7 4.1 Detailed Description .............................................................................................................................. 7 4.2 Results ................................................................................................................................................... 7 5 MPE-Based Test Exemption ............................................................................................................................ 8 5.1 Detailed Description .............................................................................................................................. 8 5.2 Results ................................................................................................................................................... 9 6 SAR-Based Test Exemption ........................................................................................................................... 10 6.1 Detailed Description ............................................................................................................................ 10 6.2 Results ................................................................................................................................................. 10 7 Simultaneous Transmission .......................................................................................................................... 11 7.1 Detailed Description ............................................................................................................................ 11 7.2 Result................................................................................................................................................... 11 8 Conclusion ...................................................................................................................................................... 12 Test report no.: 1-7035-23-01-03_TR1-R01 © cetecom advanced GmbH Page 3 of 12 2 General Information 2.1 Notes and Disclaimer The test results of this test report relate exclusively to the test item specified in this test report. cetecom advanced GmbH does not assume responsibility for any conclusions and generalizations drawn from the test results with regard to other specimens or samples of the type of the equipment represented by the test item. The test report may only be reproduced or published in full. Reproduction or publication of extracts from the report requires the prior written approval of cetecom advanced GmbH. The testing service provided by cetecom advanced GmbH has been rendered under the current "General Terms and Conditions for cetecom advanced GmbH". cetecom advanced GmbH will not be liable…

Text truncated - open the document above for the full version.

Test Report

Institute of Microwave and Photonic Engineering A. ARSANJANI, M. MEDEBACH, M. GADRINGER Bluetooth Vibration Sensor –Antenna design 06/09/2023 Scope Design an antenna for 2.45 GHz •Improved radiation performance •Rejection of second harmonic 2 Design Preliminary antenna design 3 Design Preliminary antenna design 4 Design Preliminary antenna design 5 Conclusion Why we need to know exact dimensions of the antenna board? “Ground plane effects on planar inverted-F antenna (PIFA) performance”: https://doi.org/10.1049/ip-map:20030551 1.The gain of PIFA is low for a ground plane size <0.4*lambda 2.Ground plane size significantly influences antenna radiation pattern - Why this is not a problem with other devices? Usually in handheld devices the antenna is connected to a large ground which will improve the radiation and performance of the antenna, however, since we have a small ground in this scenario, the design of the antenna is more tricky, and susceptible to changes if 6 7 Contact: [email protected] Michael Gadringer Graz University of Technology Scope Andritz antenna design 8 Scope Andritz antenna design 9 Scope Andritz antenna design 10

Test Report

TEST REPORT Test report no.: 1-7035-23-01-02_TR1-R02 Testing laboratory Applicant cetecom advanced GmbH Untertuerkheimer Strasse 6 – 10 66117 Saarbruecken / Germany Phone: + 49 681 5 98 - 0 Fax: + 49 681 5 98 - 9075 Internet: https://cetecomadvanced.com e-mail: [email protected] Accredited Testing Laboratory: The testing laboratory (area of testing) is accredited according to DIN EN ISO/IEC 17025 (2018-03) by the Deutsche Akkreditierungsstelle GmbH (DAkkS). The accreditation is valid for the scope of testing procedures as stated in the accreditation certificate with the registration number: D-PL-12047-01-00. ISED Testing Laboratory Recognized Listing Number: DE0001 FCC designation number: DE0002 ANDRITZ AG Stattegger Strasse 18 8045 Graz / AUSTRIA Phone: +43 316 6902 0 Contact: Patrick Leuk e-mail: [email protected] Manufacturer ANDRITZ AG Stattegger Strasse 18 8045 Graz / AUSTRIA Test standard/s FCC - Title 47 CFR Part 15 FCC - Title 47 of the Code of Federal Regulations; Chapter I; Part 15 - Radio frequency devices RSS - 247 Issue 4 Digital Transmission Systems, Frequency Hopping Systems and Licence-Exempt Local Area Network Devices in 902-928 MHz, 2400-2483.5 MHz, 5150-5350 MHz, and 5470-5895 MHz bands For further applied test standards please refer to section 3 of this test report. Test Item Kind of test item: Condition Monitoring Sensor for vibration and temperature Model name: MetrisVibe Pro FCC ID: 2AX58METRISVIBEPRO ISED certification number: 26689-MVIBEPRO Frequency: 2400 MHz to 2483.5 MHz Technology tested: Bluetooth ® LE Antenna: Integrated antenna Power supply: 2.6 V to 3.7 V DC by internal battery Temperature range: -40°C to +85°C This test report is electronically signed and valid without handwritten signature. For verification of the electronic signatures, the public keys can be requested at the testing laboratory. Test report authorized: Test performed: On behalf of Marco Bertolino Andreas Curette Supervisor Radio Services Lab Manager Radio Labs Radio Labs Test report no.: 1-7035-23-01-02_TR1-R02 © cetecom advanced GmbH Page 2 of 42 1 Table of contents 1 Table of contents .................................................................................................................................... 2 2 General information ................................................................................................................................ 3 2.1 Notes and disclaimer .................................................................................................................... 3 2.2 Application details ........................................................................................................................ 3 2.3 Test laboratories sub-contracted .................................................................................................. 3 3 Test standard/s, references and accreditations ....................................................................................... 4 4 Reporting statements of conformity – decision rule ................................................................................ 5 5 Test environment.................................................................................................................................... 6 6 Test item ................................................................................................................................................ 6 6.1 General description ...................................................................................................................... 6 6.2 Additional information .................................................................................................................. 6 7 Sequence of testing ................................................................................................................................ 7 7.1 Sequence of testing radiated spurious 9 kHz to 30 MHz ................................................................ 7 7.2 Sequence of testing radiated spurious 30 MHz to 1 GHz ............................................................... 8 7.3 Sequence of testing radiated spurious 1 GHz to 18 GHz ................................................................ 9 7.4 Sequence of testing radiated spurious above 18 GHz .................................................................. 10 8 Description of the test setup ................................................................................................................. 11 8.1 Shielded semi anechoic chamber ................................................................................................ 12 8.2 Shielded fully anechoic chamber ................................................................................................ 13 8.3 Radiated measurements > 18 GHz .............................................................................................. 14 8.4 Conducted measurements Bluetooth system .............................................................................. 15 9 Measurement uncertainty ..................................................................................................................... 16 10 Summary of measurement results ..................................................................................................... 17 11 Additional comments ........................................................................................................................ 18 12 Measurement results ........................................................................................................................ 19 12.1 System gain ............................................................................................................................ 19 12.2 Power spectral density ............................................................................................................ 20 12.3 DTS bandwidth – 6 dB bandwidth ....................................…

Text truncated - open the document above for the full version.

Test Report

Conducted test results No.1-7035-23-01-02_TR1-A201-R1 February 04, 2025 Test Standard(s)NA - NI FCC 15.247 - NI FCC 15.247, ISED RSS247 - NI This document is electronically signed and valid without handwritten signature. Public keys for verification of the electronic signatures can be requested at the testing laboratory. Authorized Andreas Curette Lab Manager Radio Labs cetecom advanced GmbH Untertürkheimer Str. 6-10, 66117 Saarbrücken Document No. 1-7035-23-01-02_TR1-A201-R1 Release 1 - Page 1 of 82 Table of Content NA # Peak output power 3MHz/3MHz ~ BT LE 1 Msps3 FCC 15.247 # Maximum peak conducted output power DTS ~ BT LE 1 Msps9 FCC 15.247 # Bandwidth 6dB DTS ~ BT LE 1 Msps17 FCC 15.247 # Peak psd DTS ~ BT LE 1 Msps22 FCC 15.247, ISED RSS247 # Bandwidth 99PCT and 20dB ~ BT LE 1 Msps27 FCC 15.247 # TX spurious conducted 20dBc ~ BT LE 1 Msps38 FCC 15.247 # Maximum peak conducted output power DTS ~ BT LE 2 Msps46 FCC 15.247 # Bandwidth 6dB DTS ~ BT LE 2 Msps54 FCC 15.247 # Peak psd DTS ~ BT LE 2 Msps59 FCC 15.247, ISED RSS247 # Bandwidth 99PCT and 20dB ~ BT LE 2 Msps64 FCC 15.247 # TX spurious conducted 20dBc ~ BT LE 2 Msps75 cetecom advanced GmbH Untertürkheimer Str. 6-10, 66117 Saarbrücken Document No. 1-7035-23-01-02_TR1-A201-R1 Release 1 - Page 2 of 82 NA # Peak output power 3MHz/3MHz ~ BT LE 1 Msps References TC start04.02.2025 10:16:44 Ambit temp (test rack) [°C] | humidity [rel%] not enabled | not enabled System version5.1.6.4 Standard | Version NA | NI Method DescriptionPeak OP 3MHz/3MHz - BT LE 1 Msps Information EUT Common Settings BT Low Energy Intermodulation value N 3 Image freq. Low | Mid | High [MHz] 0 | 0 | 0 Power class2 1 Mbps supported True | TXpayload 255 | RXpayload 255 2 Mbps supported True | TXpayload 255 | RXpayload 255 Longrange S8 supported True | TXpayload 255 | RXpayload 255 Longrange S2 supportedTrue | TXpayload 255 | RXpayload 255 Signaling settings WS_USB_RS232 | HCI | 4 | 115200 | None | S1 | None | On Signaling RF settings RF1com | 0 | 0 | On | User interaction No Equipment Signal analyzer,Rohde&Schwarz,FSV-30,1321.3008K30/103170,3.70 Switch matrix,cetecom advanced GmbH,USM,A001,1.0.0 Test Parameter Technology to testBT LE 1 Msps EUT portEUT1 Temperaturenom Voltagenom Frequency low to testTrue | Freq [MHz] 2402 Frequency mid to testTrue | Freq [MHz] 2440 Frequency high to testTrue | Freq [MHz] 2480 Auto control enabled power supply | Climatic Box No | No Additional path loss [dB]0.7 Full path typeEUT_SA_GEN_SIG Full path nameEUT1.MP.SIG1/EUT1.SA/EUT1.GEN1/EUT1.GEN2/ cetecom advanced GmbH Untertürkheimer Str. 6-10, 66117 Saarbrücken Document No. 1-7035-23-01-02_TR1-A201-R1 Release 1 - Page 3 of 82 Test Parameter Switch bits 00010001:00010001:00000000:00000001 cetecom advanced GmbH Untertürkheimer Str. 6-10, 66117 Saarbrücken Document No. 1-7035-23-01-02_TR1-A201-R1 Release 1 - Page 4 of 82 Test at TX 2402 MHz RESULT: Reference power cond. DESCRIPTIONLOWER LIMITUPPER LIMITMEASUREDUNITVERDICT Ref. power 1MHz/1MHz cond. ------3.38dBmINFO Ref. frequency------2402.300MHzINFO READ SA SETTINGS: RefLevel [dBm] | RefLevelOffset [dB] | InpAtt [dB]13.38 | 8.85 | 20 Start [MHz] | Stop [MHz]2399.500 | 2404.500 RBW [MHz] | VBW [MHz]3.000000 | 3.000000 Detector | TraceModePOS | MAXH Sweep: time [ms] | count | points per Section | type1000 | 10 | 1001 | SWE 2399.502400.002400.5…

Text truncated - open the document above for the full version.

Contact Information

Applicant

Elisa De Podesta Gomes(MSc. MBA)
[email protected]Fax: +433166902473

Technical Contact

ANDRITZ Inc.Tanaji Mali
[email protected]

13560 Morris Road, Suite 1250 · Alpharetta, Georgia, 30004 · United States

Test Firm

cetecom advanced GmbHGerald Schmidt
[email protected]Fax: 49-681-598-8775

Technical Specifications

#Rule PartsFrequency RangePower Output
115C2.40 GHz - 2.48 GHz2.19 mW
Confidentiality
Long Term
Grant Notes
Output power listed is peak conducted. RF exposure compliance is addressed for 1.1310 and 2.1091 MPE limits.