Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.
Hard floor cleaner BMFC01 Manual Instruction Model No.: BMHC01 Instruction Manual Contents: ο¬ Safety Instruction ο¬ Product introduction ο¬ Installation ο¬ Daily maintain & installation ο¬ Common faults ο¬ Specification Safety instruction About the manual ο¬ Please follow the manual instruction to install the machines and keep this manual instruction. If you transfer the product to any third party to use, please attach this manual instruction. Any discrepant operation might lead to the damage of the product or possible personal hurt. ο¬ We would be free of any charge if there is any loss due to operate not according to the manual instruction. Product Safety Instruction ο¬ When you clean or maintain the machine, do take the plug out. ο¬ The product is assumed to be used at home, not for commercial or industrial use. ο¬ The product is assumed to be used on hard floor, including rubber floor, marble floor, granite floor, terrazzo floor, solid wood floor, composite floor, bamboo floor, and all kinds of mirror surface tile, Porcelain tile etc which has a flat surface. This product effect might not be so good on the none-flat surface. ο¬ This product is not suitable to those who is capable on physical, Psychological (including kids). ο¬ Don't touch this electrical part with wet hands in case of any risk ο¬ Don't use this machine near to the heater, or stove which are too hot in case of machine plastic deformation. ο¬ Don't wet the machine body in case of any risk of water inlet and then leads to fire, or electric shock etc. ο¬ When using this machine, if there is situation like too much heat, or strange noise, or bad smell come out, please stop to use this machine immediately. ο¬ When the plug is damaged, please don't use the machine and ask for the after sale service for further help. ο¬ Please use our original adaptor for the charging and don't use other brand adaptor which might lead to some damage to the circuit and cause fire risk. ο¬ If you don't use this machine for a long time, please turn off this machine and take off the plug. ο¬ When you finish using the machine, make sure clean the dirty water tank in case of any risk of dirty block. ο¬ There are electrical parts on the body and lower brush, please don't immerse whole machine into water. ο¬ Please don't try to disassemble the machines and try to use this machine for other purpose, which might cause the damage of the machine. ο¬ Please use the correct voltage range to use this machine, the voltage range is indicated in the rating label. ο¬ When cleaning the stairs, please make sure you hold the machine well in case of any falling down. ο¬ After using the machine, please put the machine on the body. ο¬ Please equip the water tank(clean water and dirty water) well before using. Product parts introduction: The install of the machine: How to use this machine: Preparation when you start to use the machine, includes: ο¬ Please make sure that the machines install well and check whether the battery power is enough. ο¬ Please make sure that there is clean water in the clean water tank. Start to use: ο¬ Switch on the machine after adding the clean water into the "clean water" tank, press the switch buttons for 1~2s to let the machine work, which shall wet the rollers. ο¬ Hold the handle and move the machine on the hard floor and do the mopping. ο¬ Press the switch again to turn off the machine. ο¬ When the machine finish working, please clean the dirty water tank and clean water tank, and add 100ml~150ml water in the base and then put the machine on the base to work another 3minutes to do the self cleaning of the rollers. ο¬ Take off the rollers and dry them on the base. Start to use: Power indicator: ο¬ Power indicator lighting, indicates: 100%, 65%,30% of the power. ο¬ Three lights power range <100%, >65%. ο¬ Two lights power range: >30%, <65%. ο¬ One light power range: <30%. ο¬ Three lights twinkle: nearly no power and need to charge immediately. Charge: ο¬ Insert the adaptor to the machine, and connect with the power. Daily maintains and installs: Daily maintains and installs: Daily maintains and installs: Common faults: Common faults: Possible reason Solution Product does not work: 1. No power or shorted powered Please charge the machine 2. Dirty water tank is fulfilled. Take out the water tank and clean it. 3. Roller is blocked by the air things Clean the roller 4. If none is as above Please contact us. Product is weak in cleaning or water leakage 1. Water tank is installed in the wrong position Install the water tank again 2. Roller is blocked by hair things. Clean the roller 3. Lower battery Please charge the machine 4. If none is as above Please contact us. Machine shakes terribly: 1. Roller is not installed well. Install the roller again. 2.If none is above. Please contact us. Product could not be charged: 1. The adaptor is not collected well. Please check the adaptor connect well. 2.If none is above. Please contact us. Clean water does not come out: 1. No clean water in the clean water tank Add clean water 2. the water tank is not installed well. Re-install the water tank 3. If none is above Please contact us. Product Spec: Product Data Rated voltage: DC 11.1V Rated currence: 3.2A Battery capacity: 2200mAh Clean water tank: 400ml Dirty water tank: 250ml Charging time: 2-3h Working time after fully charging: 30min Product size: 304*250*1220mm Net weight: 2.5kg Special Safety Instructions 1. Do not use the hard floor cleaner in the immediate proximity to sources of heat and do not mop hot objects such as cigarette butts or ashes. 2. Always connect the power plug into the socket with dry hands. 3. Before you start using the machine, first remove large or sharp object from the floor in order to avoid possible damages. 4. When disconnecting the power plug, do not pull the cord, firmly grasp the plug. Cleaning and Maintenance β’ Parts of the device must not be cleaned in the dishwasher except the roller. β’ To clean the casing, switch the device off and disconnect the adaptor β¦
Text truncated - open the document above for the full version.
C5266091_X8_Ed.1 1/1 Letter of Authorization SUZHOU BENM KITCHEN CO., LTD Company: SUZHOU BENM KITCHEN CO., LTD Address: NO.555 HEAN RD. PUZHUANG TOWN WUZHONG DISTRICT, SUZHOU, CHINA Product Name: Hard floor cleaner Model Number: BMFC01 FCC Identifier: 2AX5A-BMFC01 We authorize LGAI Technological Center S.A., Ronda de la Font del Carme, s/n, 08193 Bellaterra, Spain, to act on our behalf on all matters concerning the above named equipment. Any individual within LGAI Technological Center S.A. is authorized to act on our behalf and take action on the application. We declare that authorize LGAI Technological Center S.A., Ronda de la Font del Carme, s/n, 08193 Bellaterra, Spain, is allowed to forward all information related to the approval project to the Federal Communication Commission and to discuss any issues concerning the approval application. Any and all acts carried out by LGAI Technological Center S.A. on our behalf shall have the same effect as acts of our own. Name: Merry Ma Date: Nov.04.2020 Title: Manager Signature of applicant:
C5266091_X10_Ed.2 1/1 SUZHOU BENM KITCHEN CO., LTD Office of Engineering Technology Federal Communications Commission 7435 Oakland Mills Road Columbia, MD 21046 Date: Nov.04.2020 Subject: Request for Confidentiality FCC ID: 2AX5A-BMFC01 To Whom It May Concern, Pursuant to the provisions of Sections 0.457 and 0.459 of Commission's rules (47CFR0.457, 0.459), we are requesting the Commission to withhold the following attachment(s) as confidential document from public disclosure. Exhibits Long-Term Confidentiality Short-Term Confidentiality NOTE 2 ID Label/Location No No Attestation Statement No No External Photos No β Block Diagram β β Schematics β β Test Report No No Test Setup Photos No β Userβs Manual β NOTE 1 β Internal Photos β NOTE 1 β Parts List / Tune Up β β RF Exposure Info No No Operational Description β β Cover Letter(s) No No SDR Software / Security Info β No NOTE 1: Long-Term Confidentiality may be permitted under special conditions (See II. LONG-TERM CONFIDENTIALITY, Section 3 of KDB 726920, use last in force) NOTE 2: Short-Term Confidentiality can be requested for a maximum of 180 days from the date of the grant. Above mentioned document contains detailed system and equipment description are considered as proprietary information in operation of the equipment. The public disclosure of above documents might be harmful to our company and would give competitor an unfair advantage in the market. In case of short-term Confidentiality, the applicant requests the exhibits selected above are withheld from public view for a period of ____45 __ days from the date of the Grant of Equipment Authorization and prior to marketing. It is our understanding that all measurement test reports, FCC ID label format and correspondent during certification review process cannot be granted as confidential documents and those information will be available for public review once the grant of equipment authorization is issued. C5266091_X10_Ed.2 1/1 Sincerely, Signature: Name: Merry Ma Title: Manager
External Photos FCC ID: 2AX5A-BMFC01 Receiver Transmitter
Model: BMFC01 FCC ID: 2AX5A-BMFC01 Label Location
Internal Photos F C C I D : 2 A X 5 A -B M F C 0 1 ANT
Shenzhen CTB Testing Technology Co., Ltd. Report No.: CTB201104029RFX Report Tel: 4008-707-283 Web: http://www.ctb-lab.netPage 1 of 30 TEST REPORT Compiled by: Reviewed by: Approved by: Arron Liu Bin Mei Rita Xiao / Director The test report is effective only with both signature and specialized stamp. This result(s) shown in this report refer only to the sample(s) tested. Without written approval of Shenzhen CTB Testing Technology Co., Ltd. this report canβt be reproduced except in full. The tested sample(s) and the sample information are provided by the client. Product Name: Hard floor cleaner FCC ID: 2AX5A-BMFC01 Trademark: N/A Model Number: BMFC01 Prepared For: SUZHOU BENM KITCHEN CO., LTD. Address: NO. 555 HEAN RD. PUZHUANG TOWN WUZHONG DISTRICT, SUZHOU, CHINA Manufacturer: SUZHOU BENM KITCHEN CO., LTD. Address: NO. 555 HEAN RD. PUZHUANG TOWN WUZHONG DISTRICT, SUZHOU, CHINA Prepared By: Shenzhen CTB Testing Technology Co., Ltd. Address: Floor 1&2, Building A, No. 26 of Xinhe Road, Xinqiao Street, Baoan District, Shenzhen China Sample Received Date: Oct. 31, 2020 Sample tested Date: Oct. 31, 2020 - Nov. 03, 2020 Issue Date: Nov. 03, 2020 Report No.: CTB201104029RFX Test Standards FCC Part15.231 ANSI C63.10:2013 Test Results PASS Remark: This is 433MHz radio test report. Shenzhen CTB Testing Technology Co., Ltd. Report No.: CTB201104029RFX Report Tel: 4008-707-283 Web: http://www.ctb-lab.net Page 2 of 30 TABLE OF CONTENT Test Report Declaration Page 1. VERSION............................................................ 3 2. TEST SUMMARY ..................................................... 4 3. MEASUREMENT UNCERTAINTY ....................................... 5 4. PRODUCT INFORMATION AND TEST SETUP ........................... 6 4.1 Product Information ..................................................... 6 4.2 Test Setup Configuration ................................................ 6 4.3 Support Equipment ..................................................... 6 4.4 Test Mode ............................................................. 7 4.5 Test Environment ....................................................... 7 5. TEST FACILITY AND TEST INSTRUMENT USED ......................... 8 5.1 Test Facility ............................................................ 8 5.2 Test Instrument Used ................................................... 8 6. AC POWER LINE CONDUCTED EMISSION .............................. 10 6.1 Block Diagram Of Test Setup............................................ 10 6.2 Limit ................................................................. 10 6.3 Test procedure ........................................................ 10 6.4 Test Result ........................................................... 12 7. RADIATED EMISSION ............................................... 14 7.1 Block Diagram Of Test Setup............................................ 14 7.2 Limit ................................................................. 15 7.3 Test procedure ........................................................ 16 7.4 Test Result ........................................................... 17 8. DWELL TIME ....................................................... 23 8.1 Block Diagram Of Test Setup............................................ 23 8.2 Limit ................................................................. 23 8.3 Test procedure ........................................................ 23 8.4 Test Result ........................................................... 24 9. OCCUPIED BANDWIDTH ............................................. 25 9.1 Block Diagram Of Test Setup............................................ 25 9.2 Limit ................................................................. 25 9.3 Test procedure ........................................................ 25 9.4 Test Result ........................................................... 26 10. ANTENNA REQUIREMENT ........................................... 27 11. EUT PHOTOGRAPHS ................................................ 28 12. EUT TEST SETUP PHOTOGRAPHS ................................... 29 (Note: N/A means not applicable) Shenzhen CTB Testing Technology Co., Ltd. Report No.: CTB201104029RFX Report Tel: 4008-707-283 Web: http://www.ctb-lab.net Page 3 of 30 1. VERSION Report N o. Issue Date Description Approved CTB201104029RFX Nov. 04, 2020 Original Valid Shenzhen CTB Testing Technology Co., Ltd. Report No.: CTB201104029RFX Report Tel: 4008-707-283 Web: http://www.ctb-lab.net Page 4 of 30 2. TEST SUMMARY The Product has been tested according to the following specifications: Test Item Test Requirement Test method Result AC Power Line Conducted Emission 47 CFR Part 15 Subpart C Section 15.207 ANSI C63.10-2013 N/A Radiated Emission 47 CFR Part 15 Subpart C Section 15.209; 15.231(b) ANSI C63.10-2013 PASS Dwell Time 47 CFR Part 15 Subpart C Section 15.231 (a) ANSI C63.10-2013 PASS Occupied Bandwidth 47 CFR Part 15 Subpart C Section 15.231(c) ANSI C63.10-2013 PASS Antenna requirement 47 CFR Part 15 Subpart C Section 15.203 ANSI C63.10-2013 PASS Shenzhen CTB Testing Technology Co., Ltd. Report No.: CTB201104029RFX Report Tel: 4008-707-283 Web: http://www.ctb-lab.net Page 5 of 30 3. MEASUREMENT UNCERTAINTY Where relevant, the following measurement uncertainty levels have been estimated for tests performed on the Product as specified in CISPR 16-4-2. This uncertainty represents an expanded uncertainty expressed at approximately the 95% confidence level using a coverage factor of k=2. Item Uncertainty Occupancy bandwidth U=Β±54.3Hz Conducted output power Above 1G U=Β±1 .0 dB Conducted output power below 1G U=Β±0.9dB Power Spectral Density , Conduction U=Β±1.0dB Conduction spurious emissions U=Β±2.8dB Out of band emission U=Β±54Hz 3m camber Radiated spurious emission(30MHz-1GHz) U=Β±4.3dB 3m chamber Radiated spurious emission(1GHz-18GHz) U=Β±4.5dB humidity uncertainty U=Β±5.3% Temperature uncertainty U=Β±0.59Β°C Supply voltages U=Β±3β¦
Text truncated - open the document above for the full version.
Radiated Emission Below 1GHz A bove 1GHz FCC ID: 2AX5A-BMFC01 Conducted Emission
Shenzhen Β· China
| # | Rule Parts | Frequency Range | Power Output |
|---|---|---|---|
| 1 | 15.231 | 433.92 MHz - 433.925 MHz | - |