Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.
Model No: YF658G Bidet Toilet Seat USER MANUAL Edition:V 2020.10.13 FUNCTIONS MANUAL Dearcustomers, 01 Before beginning installation, read all instructions first. Save these instructions for future use. This product is subject to standard of UL 1431. Thank you for purchasing our intelligent toilet series products, to ensure safety before using this product, please read this instruction carefully and keep it carefully for reference. IMPORTANT SAFEGUARDS --------------------------------------------------- 02 PRODUCT FUNCTIONS --------------------------------------------------------- 06 USINGGUIDE ---------------------------------------------------------------------- 06 PACKING LIST -------------------------------------------------------------------- 06 PRODUCT SIZE ------------------------------------------------------------------- 06 SIDE BUTTON --------------------------------------------------------------------- 06 TECHNICAL DATA ---------------------------------------------------------------- 07 REMOTE CONTROL USER MANUAL --------------------------------------- 08 PRODUCT INSTALLATION METHODS ------------------------------------- 10 PRODUCT CLEANING AND MAINTENANCE METHODS ------------- 12 HOW TO DEAL WITH COMMON PROBLEMS ---------------------------- 14 02 FUNCTIONS MANUAL IMPORTANT SAFEGUARDS When using electrical products, especially when children are present, basic safety precautions should always be followed, including the following: READ ALL INSTRUCTIONS BEFORE USING DANGER – To reduce the risk of electrocution: 1. Do not pour water or detergent on the power plug. It may cause fire, electric shock and other accidents. Ne versez pas d'eau ou de détergent sur la prise d'alimentation. Cela peut causer un incendie, un choc électrique ou d'autres accidents. 2. Do not bring lit cigarettes or burning species close to the product. It may cause a fire. N'amenez pas de cigarettes allumées ou d'espèces en feu à proximité du produit. Cela pourrait provoquer un incendie. 3. Please do not continue to use the product when the product fails. Please contact the after-sales service staff for maintenance. When the following situation occurs, please remove the power plug and close the inlet angle valve. ①Leakage from the inside of the product line; ② The product is unusually hot; ③ The product makes an abnormal sound and smell; ④The product is burnt. If the product is still used in the event of malfunction, it may cause problems such as fire, electric shock, water inflow in the room. (The normal life of this product is six years, the continued use beyond the service life may lead to accidents.) Veuillez ne pas continuerà utiliser le produit lorsqu'il tombe en panne. Veuillezcontacter le personnel du service après-vente pour la maintenance. Lorsque la situation suivante se produit, veuillez retirer la fiche d'alimentation et fermer la vanne d'angle d'entrée. ①Fuite de l'intérieur de la ligne de produits; ② le produit est anormalement chaud; ③ le produit émet un bruit et une odeur anormaux; ④ le produit est brûlé. Si le produit est encore utilisé en cas de dysfonctionnement, il peut causer des problèmes tels qu'incendie, choc électrique, infiltration d'eau dans la pièce (la durée de vie normale de ce produit est de six ans, la poursuite de son utilisation au-delà de la durée de vie peut entraîner des accidents). 4.①This product belongs to the electrical products, do not put it in places where there is water or the places of high humidity. When used in the bathroom, please install ventilation fan or ventilation port to keep the bathroom in good air circulation. Otherwise, it may cause a fire or electric shock. ② If the power cord is damaged, do not disassemble it yourself and must be replaced by the manufacturer or its service department or relative department. ①Ce produit est un produit électrique, ne le placez pas là où il y a de l'eau ou où l'humidité est élevée. e le mettez pas dans des endroits où il y a de l'eau ou des endroits très humides. Lorsqu'il est utilisé dans la salle de bain, veuillez installer un ventilateur ou un orifice de ventilation pour maintenir la salle de bain en bonne circulation d'air. Dans le cas contraire, cela pourrait provoquer un incendie ou un choc électrique. ② Si le cordon d'alimentation est endommagé, ne le démontez pas vous-même et il doit être remplacé par le fabricant ou son service après-vente ou le service concerné. WARNING – To reduce the risk of burns, electrocution, fire, or injury to persons. 1. It is absolutely forbidden to disassemble, repair and transform this product by yourself. It may cause fire, electric shock and other accidents. Il est absolument interdit de démonter, réparer et transformer ce produit par vous-même. Il peut causer un incendie, un choc électrique et d'autres accidents. 2.Only tap water can be used. Otherwise may cause infectious dermatitis and other diseases. N'utilisez que de l'eau courante. Sinon, cela peut causer une dermatite infectieuse et d'autres maladies. FUNCTIONS MANUAL 3. Forbiddance sitting on the seat for a long time, the seat temperature should be adjusted in low-grade, please note that low-temperature burns. The following personnel should set the seat temperature at low-grade when using the toilet. ①Children and elderly people who cannot adjust the temperature to the right degree. ② Patients, persons with disabilities and other people who can not move freely. ③ Lethargic crowd because of taking hypnotics (Such as sleeping pills, cold medicine, etc.) deep drinking and over fatigue. Ne vous asseyez pas sur le siège pendant une longue période, la température du siège doit être ajustée en bas de gamme, veuillez noter les brûlures à basse température. Les personnes suivantes doivent régler la température du siège à un niveau bas lorsqu'elles utilisent les toilettes. ①Les enfants et les personnes âgées qui ne peuvent pas régler la température au bon degré. ② Les patient…
Text truncated - open the document above for the full version.
External Photographs Page 2 of 3 UL Verification Services (Guangzhou) Co., Ltd, Song Shan Lake Branch This report shall not be reproduced except in full, without the written approval of UL Verification Services (Guangzhou) Co., Ltd, Song Shan Lake Branch. . View of EUT-1 View of EUT-2 Page 3 of 3 UL Verification Services (Guangzhou) Co., Ltd, Song Shan Lake Branch This report shall not be reproduced except in full, without the written approval of UL Verification Services (Guangzhou) Co., Ltd, Song Shan Lake Branch. . View of EUT-3 View of EUT-4
按键平鼓包 ć‰©ć•Łé€Źĺ…‰ĺ” STOP / POWERFRONT WASHREAR WASHAIR DRYING WATER TEMP. SEAT TEMP. AIR TEMP. DEFECATION CLEAN COLD & HOTCHILDREN ONE TOUCH NOZZLE CLEANING NIGHT LIGHT ENERGY SAVER NOZZLE POSITION WATER PRESSURE STOP / POWERFRONT WASHREAR WASHAIR DRYING WATER TEMP. SEAT TEMP. AIR TEMP. DEFECATION CLEAN COLD & HOTCHILDREN ONE TOUCH NOZZLE CLEANING NIGHT LIGHT ENERGY SAVER NOZZLE POSITION WATER PRESSURE IC: 26730-YJR201EN FCC ID: 2AX6BYJR201EN Model number: YJR201EN This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) this device may not cause harmful Interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.
Internal Photographs Page 2 of 3 UL Verification Services (Guangzhou) Co., Ltd, Song Shan Lake Branch This report shall not be reproduced except in full, without the written approval of UL Verification Services (Guangzhou) Co., Ltd, Song Shan Lake Branch. Internal View of EUT-1 Internal View of EUT-2 Page 3 of 3 UL Verification Services (Guangzhou) Co., Ltd, Song Shan Lake Branch This report shall not be reproduced except in full, without the written approval of UL Verification Services (Guangzhou) Co., Ltd, Song Shan Lake Branch. Internal View of EUT-3 Internal View of EUT-4 Antenna
The results reported herein have been performed in accordance with the laboratory’s terms of accreditation. This report shall not be reproduced except in full without the written approval of the Laboratory. The results in this report apply to the test sample(s) mentioned above at the time of the testing period only and are not to be used to indicate applicability to other similar products. CFR 47 FCC PART 15 SUBPART C ISED RSS-210 ISSUE 10 TEST REPORT For Remote Control MODEL NUMBER: YJR201EN FCC ID: 2AX6BYJR201EN IC: 26730-YJR201EN REPORT NUMBER: 4789709534-1 ISSUE DATE: December 30, 2020 Prepared for Guangdong Wealwell Technology Co., Ltd. Fuzhong Industrial Zone, Guxiang District, Chaozhou City, Guangdong Province, China 521000 Prepared by UL Verification Services (Guangzhou) Co., Ltd, Song Shan Lake Branch Building 10, Innovation Technology Park, No. 1, Li Bin Road, Song Shan Lake Hi- Tech Development Zone Dongguan, 523808, People’s Republic of China Tel: +86 769 22038881 Fax: +86 769 33244054 Website: www.ul.com REPORT NO.: 4789709534-1 Page 2 of 48 UL Verification Services (Guangzhou) Co., Ltd, Song Shan Lake Branch FORM NO.: 10-SL-F0058 This report shall not be reproduced except in full, without the written approval of UL Verification Services (Guangzhou) Co., Ltd, Song Shan Lake Branch. Revision History Rev. Issue Date Revisions Revised By V0 11/26/2020 Initial Issue REPORT NO.: 4789709534-1 Page 3 of 48 UL Verification Services (Guangzhou) Co., Ltd, Song Shan Lake Branch FORM NO.: 10-SL-F0058 This report shall not be reproduced except in full, without the written approval of UL Verification Services (Guangzhou) Co., Ltd, Song Shan Lake Branch. Summary of Test Results Clause Test Items FCC/ISED Rules Test Results 1 20 dB Bandwidth and 99 % Occupied Bandwidth CFR 47 FCC §15.215 (c) ISED RSS-Gen Clause 6.7 Pass 2 Radiated Emission CFR 47 FCC §15.249 (a)(d)(e) ISED RSS-210 Annex B B.10 CFR 47 FCC §15.205 and §15.209 RSS-GEN Clause 8.9 RSS-GEN Clause 8.10 Pass 3 Antenna Requirement CFR 47 FCC §15.203 ISED RSS-Gen Clause 6.3 Pass Note 1: This test report is only published to and used by the applicant, and it is not for evidence purpose in China. Note 2: The measurement result for the sample received is <Pass> according to < CFR 47 FCC PART 15 SUBPART C, ISED RSS-210 Issue 10 and ISED RSS-GEN Issue 5 > when <Accuracy Method> decision rule is applied. REPORT NO.: 4789709534-1 Page 4 of 48 UL Verification Services (Guangzhou) Co., Ltd, Song Shan Lake Branch FORM NO.: 10-SL-F0058 This report shall not be reproduced except in full, without the written approval of UL Verification Services (Guangzhou) Co., Ltd, Song Shan Lake Branch. TABLE OF CONTENTS 1. ATTESTATION OF TEST RESULTS ................................................................................. 5 2. TEST METHODOLOGY ..................................................................................................... 6 3. FACILITIES AND ACCREDITATION ................................................................................. 6 4. CALIBRATION AND UNCERTAINTY ................................................................................ 7 4.1. MEASURING INSTRUMENT CALIBRATION .............................................................. 7 4.2. MEASUREMENT UNCERTAINTY ............................................................................... 7 5. EQUIPMENT UNDER TEST ............................................................................................... 8 5.1. DESCRIPTION OF EUT .............................................................................................. 8 5.2. MAXIMUM FIELD STRENGTH .................................................................................... 8 5.3. CHANNEL LIST ........................................................................................................... 8 5.4. DESCRIPTION OF AVAILABLE ANTENNAS .............................................................. 9 5.5. TEST ENVIRONMENT ................................................................................................ 9 5.6. DESCRIPTION OF TEST SETUP ...............................................................................10 5.7. MEASURING INSTRUMENT AND SOFTWARE USED ..............................................11 6. ANTENNA PORT TEST RESULTS ...................................................................................13 6.1. ON TIME AND DUTY CYCLE .....................................................................................13 6.2. 20 dB BANDWIDTH AND 99 % OCCUPIED BANDWIDTH ........................................15 7. RADIATED TEST RESULTS .............................................................................................18 7.1. LIMITS AND PROCEDURE ........................................................................................18 7.2. FIELD STRENGTH OF FUNDAMENTAL ....................................................................25 7.3. RESTRICTED BANDEDGE AND FIELD STRENGTH OF INTENTIONAL EMISSIONS 29 7.4. SPURIOUS EMISSIONS (1~3 GHz) ...........................................................................33 7.5. SPURIOUS EMISSIONS (3~18 GHz) .........................................................................37 7.6. SPURIOUS EMISSIONS (18~26 GHz) .......................................................................41 7.7. SPURIOUS EMISSIONS BELOW 30 MHz .................................................................43 7.8. SPURIOUS EMISSIONS BELOW 1 GHz AND ABOVE 30 MHz .................................46 8. ANTENNA REQUIREMENTS ............................................................................................48 REPORT NO.: 4789709534-1 Page 5 of 48 UL Verification Services (Guangzhou) Co., Ltd, Song Shan Lake Branch FORM NO.: 10-SL-F0058 This report shall not be reproduced except in full, without the written approval of UL Verification Services (Guangzhou) Co., Ltd, Song Shan Lake Branch. 1. ATTESTATION OF TEST RESULTS Appli…
Text truncated - open the document above for the full version.
Appendix II Setup Photographs RADIATED RF MEASUREMENT SETUP (ABOVE 1 GHz) MEASUREMENT POSITION (X axis) MEASUREMENT POSITION (Y axis) MEASUREMENT POSITION (Z axis) RADIATED RF MEASUREMENT SETUP (30MHz~1GHz) RADIATED RF MEASUREMENT SETUP (Below 30MHz)
| # | Rule Parts | Frequency Range | Power Output |
|---|---|---|---|
| 1 | 15C | 2.41 GHz - 2.44 GHz | - |