Marostica, 18/03/2026 DEKRA Testing and Certification, S.A.U. Parque TecnolĂłgico de AndalucĂa C/ Severo Ochoa 2 & 6 29590 Campanillas Málaga, España Certifications concerning “covered” equipment. Section 2.911(d)(5)(i)- (ii) FCC ID: 2AX78 – 41009-D1 We, Vimar Spa, Viale Vicenza 14 36063 Marostica VI Italy, certify that: - the equipment for which authorization is sought is not “covered” equipment prohibited from receiving an equipment authorization pursuant to section 2.903 of the FCC rules. - as of the date of the filing of the application, the applicant is not identified on the Covered List as an entity producing “covered” equipment. Also, we certify that the equipment for which authorization is sought does not contain or includes equipment with integrated cybersecurity and anti-virus software produced or provided by Kaspersky Lab, Inc. or any of its successors and assignees. Sincerely, __________________________ By: Ermanno Tosin Title: Industrial Operations - Standards and Certifications Company: Vimar SpA Telephone: +390424488179 e-mail: [email protected]
Marostica, 18/03/2026 DEKRA Testing and Certification, S.A.U. Parque TecnolĂłgico de AndalucĂa C/ Severo Ochoa 2 & 6 29590 Campanillas Málaga, España Ref: sDoC declaration letter for equipment with FCC ID: 2AX78 – 41009-D1 Pursuant to §15.101 of the Commission’s Rules (47 C.F.R.), Vimar Spa hereby declare that the device above mentioned is classified under the following equipment class/classes: JAB Part 15 Class B Digital Device JAD Part 15 Class A Digital Device JAV Other Non-Digital SDoC Devices JBP Part 15 Class B Computing Device/Personal Computer JBC Part 15 Class B Computing Device/Personal Computer CXX Communications Rcvr for use w/ licensed Tx and CBs CRR Superregenerative Receiver CYY Communications Receiver used w/Pt 15 Transmitter HID Part 15 TV Interface Device And will follow the Authorization procedure Supplier’s Declaration of Conformity prior to the initiation of marketing. Sincerely, __________________________ By: Ermanno Tosin Title: Industrial Operations - Standards and Certifications Company: Vimar SpA Telephone: +390424488179 e-mail: [email protected]
iCertifi Control Number - IC2026ASOP12324 Federal Communications Commission Authorization and Evaluation Division 7435 Oakland Mills Road Columbia, MD 21046 USA Date: 27/04/2026 Ref: Attestation Statement Part 2.911(d)(7) Filing FCC ID: 2AX78-41009-D1 VIMAR SpA certifies that, as of the dates of this application, Americas Compliance Consulting LLC dba iCertifi is our designated U.S. agent for service of process for the above referenced FCC ID. Manufacturer accepts to maintain an agent for no less than two year after the grantee has terminated all marketing and importation or the conclusion of any commission-related proceeding involving the equipment. iCertifi accepts, as of the date of the filing of the application, the obligation of the designated U.S. agent for service process for the above referenced FCC ID. Designated U.S. Agent Information: Name: Americas Compliance Consulting LLC dba iCertifi FCC FRN: 0033399411 Address: 5809 US-2, Suite B, Albeni Plaza Priest River, Idaho 83856, United States Contact Person: Paul Preston Tel: +1 (866) 885-4575 Email: [email protected] Sincerely, VIMAR SpAAmericas Compliance Consulting LLC dba iCertifi FRN: FRN: 0033399411 Ermanno TosinPaul Preston [email protected]@icertifi.com +39 0424 488 179+1 (866) 885-4575 Signature: Signature: 0030202410
Marostica, 18/03/2026 DEKRA Testing and Certification, S.A.U. Parque TecnolĂłgico de AndalucĂa C/ Severo Ochoa 2 & 6 29590 Campanillas Málaga, España Ref: Agent letter for FCC ID: 2AX78–41009-D1 We, Vimar Spa, Viale Vicenza 14 36063 Marostica VI Italy, hereby authorize DEKRA Testing and Certification srl, Via della Fisica, 20 – 36016 – Thiene (VI) Mr. Carraro Fabio, e-mail: [email protected], Phone: +390445367702 to act as our agent in the preparation of this application for equipment certification, including the signing of all documents relating to these matters. The present authorization considers the development of documents on behalf of the client, written under his own letterhead and related to the necessary information to be provided on his behalf to complete the certification process. We also hereby certify that neither we nor any party to this application are subject to a denial of U.S. Federal benefits, which include FCC benefits, pursuant to Section 5301 of the Anti-Drug Abuse Act of 1988, U.S.C. 862 because of conviction for possession or distribution of controlled substance. For instances where our authorized agent signs the application for certification on our behalf, I acknowledge that all responsibility for complying with the terms and conditions for Certification, as specified by DEKRA Testing and Certification, S.A.U., still resides with us. This agreement expires one year from the current date. Sincerely, __________________________ By: Ermanno Tosin Title: Industrial Operations - Standards and Certifications Company: Vimar SpA Telephone: +390424488179 e-mail: [email protected]
Marostica, 18/03/2026 DEKRA Testing and Certification, S.A.U. Parque TecnolĂłgico de AndalucĂa C/ Severo Ochoa 2 & 6 29590 Campanillas Málaga, España Ref: Confidentiality request for FCC ID: 2AX78–41009-D1 To whom it may concern: Pursuant to §0.457(d)(1)(ii) and §0.459 of the Commission’s Rules (47 C.F.R.) and §552 (b)(4) of the Freedom of Information Act, Vimar Spa hereby requests that a part of the subject FCC application be held confidential to avoid release of sensitive information of the product to the public. For the product stated above, we request that the following information be withheld from public disclose: Type of Confidentiality Requested Exhibit Short Term Permanent Block Diagrams Short Term External Photos Short Term Internal Photos Short Term Permanent Operation Description Short Term Permanent Parts List & Placement/BOM Short Term Permanent Tune-Up Procedure Short Term Permanent Schematics Short Term Test Setup Photos Short Term User’s Manual Short Term Permanent SDR software and security information Permanent Confidentiality: The above materials contain trade secrets and proprietary information not customarily released to the public. The public disclosure of these matters might be harmful to us and provide unjustified benefits to our competitors. Short-Term Confidentiality: We hereby request short-term confidentiality for the product stated above to avoid premature release of sensitive information prior to marketing or release of the product to the public. Release date of short term confidentiality is: 45 days from grant date marked 90 days from grant date marked 135 days from grant date marked 180 days from grant date marked Specific date: We are also aware that we are responsible to notify DEKRA in the event information regarding the product or the product is made available to the public. DEKRA will then release the documents listed above for public disclosure pursuant to FCC Public Notice DA 04-1705. Sincerely, __________________________ By: Ermanno Tosin Title: Industrial Operations - Standards and Certifications Company: Vimar SpA Telephone: +390424488179 e-mail: [email protected]
Marostica, 18/03/2026 DEKRA Testing and Certification, S.A.U. Parque TecnolĂłgico de AndalucĂa C/ Severo Ochoa 2 & 6 29590 Campanillas Málaga, España Declaration of RF Exposure Compliance for FCC ID: 2AX78 – 41009-D1 We, Vimar Spa, Viale Vicenza 14 36063 Marostica VI Italy, confirm compliance with the RF radiation exposure requirements specified in §§1.1307(b), 1.1310, 2.1091, and 2.1093 of the Commission’s Rules (47 C.F.R.) as appropriate. Sincerely, __________________________ By: Ermanno Tosin Title: Industrial Operations - Standards and Certifications Company: Vimar SpA Telephone: +390424488179 e-mail: [email protected]
DEKRA Testing and Certification S.r.l. Via della Fisica 20, 36016 Thiene (VI) - Italy Tel. +39 0445 367702 - [email protected] Report nr.: R25161301 rev. 1.0 Page 1 of 17 (#) information provided by the customer Test report nr. R25161301 Federal Communication Commission (FCC) Customer Vimar S.p.A. Viale Vicenza, 14 – 36063 Marostica (VI) – Italy (#) FCC ID 2AX78-41009-D1 (#) Description of item tested 2F+ A/V + teleloop front unit (#) Trademark Elvox (#) Model and/or type reference 41009.D1 (#) Manufacturer Vimar S.p.A. Viale Vicenza, 14 – 36063 Marostica (VI) – Italy (#) Rating(s) 28 Vdc from BUS Test method requested, standard(s) KDB 447498 D01 General RF Exposure Guidance v06 Tested by (name / position & signature) G. Gandini Technician Approved by (name / position & signature) F. Marenda Laboratory manager Date of issue 01.12.2025 General disclaimer The test results presented in this report relate only to the item tested. This report shall not be reproduced, except in full, without the written approval of DEKRA Testing and Certification S.r.l. Report template No FCC_SAR_mobile_DEKRA DEKRA Testing and Certification S.r.l. Via della Fisica 20, 36016 Thiene (VI) - Italy Tel. +39 0445 367702 - [email protected] Report nr.: R25161301 rev. 1.0 Page 2 of 17 Summary SUMMARY ..................................................................................................................................................... 2 COMPETENCES AND GUARANTEES ......................................................................................................... 3 GENERAL CONDITIONS ............................................................................................................................... 3 DATA PROVIDED BY THE CUSTOMER ...................................................................................................... 3 REFERENCE STANDARDS .......................................................................................................................... 4 USAGE OF SAMPLES ................................................................................................................................... 5 TEST SAMPLE DESCRIPTION ..................................................................................................................... 6 PHOTOS OF THE TEST ITEM ...................................................................................................................... 7 TESTING PERIOD AND PLACE .................................................................................................................... 9 DOCUMENT HISTORY .................................................................................................................................. 9 LIST OF ATTACHMENTS .............................................................................................................................. 9 ENVIRONMENTAL CONDITIONS ............................................................................................................... 10 REMARKS AND COMMENTS ..................................................................................................................... 11 DEVIATIONS FROM TEST SPECIFICATION ............................................................................................. 11 TESTING VERDICTS ................................................................................................................................... 11 VERDICT SUMMARY .................................................................................................................................. 12 TEST RESULTS ........................................................................................................................................... 13 RF EXPOSURE ANALYSIS ............................................................................................................................ 13 ATTACHMENT 1 .......................................................................................................................................... 15 DEKRA Testing and Certification S.r.l. Via della Fisica 20, 36016 Thiene (VI) - Italy Tel. +39 0445 367702 - [email protected] Report nr.: R25161301 rev. 1.0 Page 3 of 17 Competences and guarantees In order to assure the traceability to other national and international laboratories, DEKRA Testing and Certification S.r.l. has a calibration and maintenance program for its measurement equipment. DEKRA Testing and Certification S.r.l. guarantees the reliability of the data presented in this report, which is the result of the measurements and the tests performed to the item under test on the date and under the conditions stated on the report and, it is based on the knowledge and technical facilities available at DEKRA Testing and Certification S.r.l. at the time of performance of the test. DEKRA Testing and Certification S.r.l. is liable to the customer for the maintenance of the confidentiality of all information related to the item under test and the results of the test. General conditions 1. This report is only referred to the item that has undergone the test. 2. This report does not constitute or imply on its own an approval of the product by the Certification Bodies or competent Authorities. 3. This document is only valid if complete; no partial reproduction can be made without previous written permission of DEKRA Testing and Certification S.r.l. 4. This test report cannot be used partially or in full for publicity and/or promotional purposes without previous written permission of DEKRA Testing and Certification S.r.l. and the Accreditation Bodies. Data provided by the customer Information relating to the description of the sample, components list, and software/hardware version (if reported) are provided by the customer/manufacturer. DEKRA Testing and Certification S.r.l. cannot be considered responsible for this information, for any other document provided by the customer/manufacturer and…
Text truncated - open the document above for the full version.
Model: MMD00000000204 Athena S.r.l. (socio unico) Tel: +39 045 7514261 Via Nenni 7 Fax: +39 045 4743082 37024 Negrar di Valpolicella (VR) Italy www.rationalseed.com Document Code: TRL00103604902 Title: Radiation Lobes of Vimar Pixel for FCC/ISED Regulations Date: 11/06/2026 Authors: Massimo Legnani Revision: - Approval: Massimo Legnani Total pages: copertina+13 State: Final Distribution: Internal; Vimar S.p.A. Versions Code Date Authors Notes TRL00103604901 20/11/2025 ML TRL00103604902 11/06/2026 ML Total Gain Peak Synthetic results added. Model: MMD00000000204 TRL00103604902 Authors: ML Date: 11/06/2026 Radiation Lobes of Vimar Pixel for FCC/ISED Regulations Modello: MMD00000000204 I 1 Acronyms, Glossary, Conventions ................................................................................ 1 2 Bibliography and Reference Documents ...................................................................... 2 3 Document Subject ........................................................................................................ 3 4 RF Conducted measures .............................................................................................. 3 5 Relevant Radiation Lobes for FCC/ISED Regulations .................................................. 5 5.1 2402MHz ............................................................................................................... 6 5.2 2440MHz ............................................................................................................... 8 5.3 2480MHz ............................................................................................................. 10 6 Antenna Gains ............................................................................................................ 12 TRL00103604902 Authors: ML Date: 11/06/2026 Radiation Lobes of Vimar Pixel for FCC/ISED Regulations Modello: MMD00000000204 1 di 12 1 Acronyms, Glossary, Conventions Table 1-1 introduces the acronyms used inside the document: Acronym Meaning EIRP Effective Isotropic Radiated Power RF Radio Frequency Table 1-1 Table 1-2 introduces the Glossary of terms used inside the document: Term Meaning Table 1-2 Table 1-3 introduces the conventions list adopted by the document: Convention Meaning Table 1-3 TRL00103604902 Authors: ML Date: 11/06/2026 Radiation Lobes of Vimar Pixel for FCC/ISED Regulations Modello: MMD00000000204 2 di 12 2 Bibliography and Reference Documents Table 2-1 shows the list of books, articles and documents cited within the document and the correlation with the code used for their citation: Citation Data Code “Test Report nr. R25159501 Radio Spectrum Matters”; Dekra Testing and Certifications S.r.l. [1] Table 2-1 TRL00103604902 Authors: ML Date: 11/06/2026 Radiation Lobes of Vimar Pixel for FCC/ISED Regulations Modello: MMD00000000204 3 di 12 3 Document Subject The document reports the radiation lobes of Vimar Pixel. In detail the document reports: • RF Conducted measures • Relevant radiation lobes for FCC/ISED 4 RF Conducted measures The peak conducted measures are realized removing the BALUN circuit and changing the value of C34 (part the antenna matching circuit to 50Ω) with and inductance with the value of 2.4nH (50Ω impedance matching with the instrument). The results are reported below: Figure 4-1 TRL00103604902 Authors: ML Date: 11/06/2026 Radiation Lobes of Vimar Pixel for FCC/ISED Regulations Modello: MMD00000000204 4 di 12 Figure 4-2 Figure 4-3 TRL00103604902 Authors: ML Date: 11/06/2026 Radiation Lobes of Vimar Pixel for FCC/ISED Regulations Modello: MMD00000000204 5 di 12 5 Relevant Radiation Lobes for FCC/ISED Regulations All the measures are realized with compensation related to the peak radiated measures realized in the Dekra chamber used for [1] compliance measures. Specifically: Peak power at 2402MHz: 2,16dBm EIRP (20°C) Peak power at 2444MHz: 1,70dBm EIRP (20°C) Peak power at 2480MHz: 1,99dBm EIRP (20°C) The nominal RF conducted output power adopted is derived from the measures documented in chapter 4. The measure set up is shown in Figure 5-1: Figure 5-1 TRL00103604902 Authors: ML Date: 11/06/2026 Radiation Lobes of Vimar Pixel for FCC/ISED Regulations Modello: MMD00000000204 6 di 12 5.1 2402MHz Without any compensation the EIRP peak measured is 2,99dBm. To calibrate the measure with the EIRP peak reported in [1], a correction of -0,83dB (offset 0,83dB) is applied. The final results are shown in Figure 5-2, Figure 5-3, Figure 5-4, Figure 5-5: Figure 5-2 Figure 5-3 TRL00103604902 Authors: ML Date: 11/06/2026 Radiation Lobes of Vimar Pixel for FCC/ISED Regulations Modello: MMD00000000204 7 di 12 Figure 5-4 Figure 5-5 TRL00103604902 Authors: ML Date: 11/06/2026 Radiation Lobes of Vimar Pixel for FCC/ISED Regulations Modello: MMD00000000204 8 di 12 5.2 2440MHz Without any compensation the EIRP peak measured is 7,68dBm. To calibrate the measure with the EIRP peak reported in [1], a correction of -5,98dB (offset 5,98dB) is applied. The final results are shown in Figure 5-6, Figure 5-7, Figure 5-8, Figure 5-9: Figure 5-6 Figure 5-7 TRL00103604902 Authors: ML Date: 11/06/2026 Radiation Lobes of Vimar Pixel for FCC/ISED Regulations Modello: MMD00000000204 9 di 12 Figure 5-8 Figure 5-9 TRL00103604902 Authors: ML Date: 11/06/2026 Radiation Lobes of Vimar Pixel for FCC/ISED Regulations Modello: MMD00000000204 10 di 12 5.3 2480MHz Without any compensation the EIRP peak measured is 7,84dBm. To calibrate the measure with the EIRP peak reported in [1], a correction of -5,85dB (offset 5,85dB) is applied. The final results are shown in Figure 5-10, Figure 5-11, Figure 5-12, Figure 5-13: Figure 5-10 Figure 5-11 TRL00103604902 Authors: ML Date: 11/06/2026 Radiation Lobes of Vimar Pixel for FCC/ISED Regulations Modello: MMD00000000204 11 di 12 Figure 5-12 Figure 5-13 TRL00103604902 Authors: ML Date: 11/06/2026 Radiation Lobes of Vimar Pixel for FCC/ISED Regulations Modello: MMD00000000204 12 di 12 6 Antenna Gains The antenna peak gai…
Text truncated - open the document above for the full version.
DEKRA Testing and Certification S.r.l. Via della Fisica 20, 36016 Thiene (VI) - Italy Tel. +39 0445 367702 - [email protected] Report nr.: R25181101 rev. 1.0 Page 1 of 75 00152 (#) information provided by the customer Test report nr. R25181101 Federal Communication Commission (FCC) Customer Vimar S.p.A. Viale Vicenza, 14 – 36063 Marostica (VI) – Italy (#) FCC ID 2AX78-41009-D1 (#) Description of item tested 2F+ A/V + teleloop front unit (#) Trademark Elvox (#) Model and/or type reference 41009.D1 (#) Manufacturer Vimar S.p.A. Viale Vicenza, 14 – 36063 Marostica (VI) – Italy (#) Rating(s) 28 Vdc from BUS Test method requested, standard(s) FCC Rules & Regulations, Title 47:2024 Part 15 paragraph(s): 203, 204, 205, 207, 209, 215 and 247 Tested by (name / position & signature) G. Gandini Technician Approved by (name / position & signature) F. Marenda Laboratory manager Date of issue 01.12.2025 General disclaimer The test results presented in this report relate only to the item tested. This report shall not be reproduced, except in full, without the written approval of DEKRA Testing and Certification S.r.l. Report template No 15-247_DTS_DEKRA DEKRA Testing and Certification S.r.l. Via della Fisica 20, 36016 Thiene (VI) - Italy Tel. +39 0445 367702 - [email protected] Report nr.: R25181101 rev. 1.0 Page 2 of 75 00152 Summary SUMMARY ..................................................................................................................................................... 2 COMPETENCES AND GUARANTEES ......................................................................................................... 3 GENERAL CONDITIONS ............................................................................................................................... 3 DATA PROVIDED BY THE CUSTOMER ...................................................................................................... 3 REFERENCE STANDARDS .......................................................................................................................... 4 USAGE OF SAMPLES ................................................................................................................................... 5 TEST SAMPLE DESCRIPTION ..................................................................................................................... 6 PHOTOS OF THE TEST ITEM ...................................................................................................................... 7 TESTING PERIOD AND PLACE .................................................................................................................... 9 DOCUMENT HISTORY .................................................................................................................................. 9 LIST OF ATTACHMENTS .............................................................................................................................. 9 ENVIRONMENTAL CONDITIONS ............................................................................................................... 10 REMARKS AND COMMENTS ..................................................................................................................... 11 DEVIATIONS FROM TEST SPECIFICATION ............................................................................................. 11 TESTING VERDICTS ................................................................................................................................... 11 VERDICT SUMMARY .................................................................................................................................. 12 TEST RESULTS ........................................................................................................................................... 13 ANTENNA REQUIREMENTS ........................................................................................................................... 13 CONDUCTED EMISSION ................................................................................................................................ 14 EMISSIONS IN RESTRICTED FREQUENCY BANDS AND IN UNRESTRICTED FREQUENCY BANDS ............................. 24 DTS BANDWIDTH ........................................................................................................................................ 53 20 DB BANDWIDTH ...................................................................................................................................... 57 BAND EDGE ................................................................................................................................................ 61 FUNDAMENTAL EMISSION OUTPUT POWER .................................................................................................... 65 MAXIMUM POWER SPECTRAL DENSITY LEVEL IN THE FUNDAMENTAL EMISSION ................................................ 69 ATTACHMENT 1 .......................................................................................................................................... 73 DEKRA Testing and Certification S.r.l. Via della Fisica 20, 36016 Thiene (VI) - Italy Tel. +39 0445 367702 - [email protected] Report nr.: R25181101 rev. 1.0 Page 3 of 75 00152 Competences and guarantees In order to assure the traceability to other national and international laboratories, DEKRA Testing and Certification S.r.l. has a calibration and maintenance program for its measurement equipment. DEKRA Testing and Certification S.r.l. guarantees the reliability of the data presented in this report, which is the result of the measurements and the tests performed to the item under test on the date and under the conditions stated on the report and, it is based on the knowledge and technical facilities available at DEKRA Testing and Certification S.r.l. at the time of performance of the test. DEKRA Testing and Certification S.r.l. is liable to the customer for the maintenan…
Text truncated - open the document above for the full version.
SETUP PHOTO
5809 US-2, Suite B, Albeni Plaza Priest River · Idaho, 83856 · United States
| # | Rule Parts | Frequency Range | Power Output |
|---|---|---|---|
| 1 | 15C | 2.40 GHz - 2.48 GHz | 1.18 mW |