Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.
Specifications: • Power:10W/7.5W/5W • Input: 5V-2A, 9V-1.67A • Output: 5V/1A 9V/1.1A • Coil type: single coil • Transmission distance: ≤5mm • Working frequency: 137KHZ • Conversion efficiency: ≥75% Includes: • Wireless Charger • Micro Cable (Cord plugs into USB-A outlets.) Charging Devices: Plug USB cord into USB port, make sure the micro plug in the charging pad is connected/secure. Small LED light on charging pad will light up when plugged into USB port. Place phone/device on charging pad. Check/Confirm, LED light will change from Red to Blue when device is charging. Reposition device if charger not engaging. Attention: 1. Please keep the charger away from water or other liquid. 2. Please make sure it’s not connected with power supply when you need to clean the charger. 3. Using environmental temperature remains 0-45°C Note: Wireless charger is intelligent item with simple design, compatible with any mobile phones with Qi standard. Please note that receiver is required if your phone doesn’t support. Made in China This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, (2) this device must accept any interference received, including interference that may cause undesired operation. Any Changes or modifications not expressly approved by the party responsible for compliance could void the user's authority to operate the equipment. This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures: - Reorient or relocate the receiving antenna. - Increase the separation between the equipment and receiver. - Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. - Consult the dealer or an experienced radio/TV technician for help. FCC RF exposure statement: The equipment complies with FCC radiation exposure limits set forth for an uncontrolled environment. During the operation of device a distance of 15 cm surrounding the device and 20 cm above the top surface of the device must be respected .
Keytech Intelligent Technologies Limited. Statement Product Name: Wireless charger Model No.: KQI043,KQI043BK, KQI043BU, KQI043RD, KQIWH We(Keytech Industrial Park, Liaokeng, Shiyan, Baoan District, Shenzhen ) hereby state that all models above are identical in interior structure, electrical circuits and components, All the models are of the same circuit and RF module, except the model No. and color. Signature: Name / title:Weng Yimiao / Manager Tel: +0755-84847799-8031 Date: 2019/7/17
C5266091_X8_Ed.1 1/1 Letter of Authorization Keytech Intelligent Technologies Limited Company: Keytech Intelligent Technologies Limited Address: Keytech Industrial Park, Liaokeng, Shiyan, Baoan District, Shenzhen Product Name: Wireless charger Model Number: KQI043, KQI043BK, KQI043BU, KQI043RD, KQIWH FCC Identifier: 2AXEM-KQI043 We authorize LGAI Technological Center S.A., Ronda de la Font del Carme, s/n, 08193 Bellaterra, Spain, to act on our behalf on all matters concerning the above named equipment. Any individual within LGAI Technological Center S.A. is authorized to act on our behalf and take action on the application. We declare that authorize LGAI Technological Center S.A., Ronda de la Font del Carme, s/n, 08193 Bellaterra, Spain, is allowed to forward all information related to the approval project to the Federal Communication Commission and to discuss any issues concerning the approval application. Any and all acts carried out by LGAI Technological Center S.A. on our behalf shall have the same effect as acts of our own. Name: Weng Yimiao Date: 9/16/2020 Title: Manager Signature of applicant:
C5266091_X10_Ed.1 1/1 Keytech Intelligent Technologies Limited Office of Engineering Technology Federal Communications Commission 7435 Oakland Mills Road Columbia, MD 21046 Date: 9/16/2020 Subject: Request for Confidentiality FCC ID: 2AXEM-KQI043 To Whom It May Concern, Pursuant to the provisions of Sections 0.457 and 0.459 of Commission's rules (47CFR0.457, 0.459), we are requesting the Commission to withhold the following attachment(s) as confidential document from public disclosure. Exhibits Long-Term Confidentiality Short-Term Confidentiality ID Label/Location No No Attestation Statement No No External Photos No Block Diagram Schematics Test Report No No Test Setup Photos No User’s Manual Internal Photos Parts List / Tune Up RF Exposure Info Operational Description Cover Letter(s) No No SDR Software / Security Info No Above mentioned document contains detailed system and equipment description are considered as proprietary information in operation of the equipment. The public disclosure of above documents might be harmful to our company and would give competitor an unfair advantage in the market. It is our understanding that all measurement test reports, FCC ID label format and correspondent during certification review process cannot be granted as confidential documents and those information will be available for public review once the grant of equipment authorization is issued. Sincerely, Signature: Name: Weng Yimiao Date: 9/16/2020 Title: Manager
- Page 1 of 4 - Report No.: MTi20081408-2E1-1 Tel:(86-755)88850135 Fax: (86-755) 88850136 Web: http://www.mtitest.com E-mail: [email protected] Address: 101, No. 7, Zone 2, Xinxing Industrial Park, Fuhai Avenue, Xinhe Community, Fuhai Street, Bao’ an District, Shenzhen, Guangdong, China. APPENDIX 1: EUT PHOTO Photo 1 (For model KQI043) Photo 2 - Page 2 of 4 - Report No.: MTi20081408-2E1-1 Tel:(86-755)88850135 Fax: (86-755) 88850136 Web: http://www.mtitest.com E-mail: [email protected] Address: 101, No. 7, Zone 2, Xinxing Industrial Park, Fuhai Avenue, Xinhe Community, Fuhai Street, Bao’ an District, Shenzhen, Guangdong, China. Photo 3 Photo 4 - Page 3 of 4 - Report No.: MTi20081408-2E1-1 Tel:(86-755)88850135 Fax: (86-755) 88850136 Web: http://www.mtitest.com E-mail: [email protected] Address: 101, No. 7, Zone 2, Xinxing Industrial Park, Fuhai Avenue, Xinhe Community, Fuhai Street, Bao’ an District, Shenzhen, Guangdong, China. Photo 5 Photo 6 - Page 4 of 4 - Report No.: MTi20081408-2E1-1 Tel:(86-755)88850135 Fax: (86-755) 88850136 Web: http://www.mtitest.com E-mail: [email protected] Address: 101, No. 7, Zone 2, Xinxing Industrial Park, Fuhai Avenue, Xinhe Community, Fuhai Street, Bao’ an District, Shenzhen, Guangdong, China. Photo 7 ----END OF REPORT----
40mm*50mm Wireless charger Model: KQI043 Rating Input: 4.3V-5.5V/2A, 8.5V-9.5V/1.67A Keytech Intelligent Technologies Limited Address:Keytech Industrial Park, Liaokeng, Shiyan, Baoan District, Shenzhen FCC ID: 2AXEM-KQI043 Importer: Keytech Intelligent Technologies Limited Address : Keytech Industrial Park, Liaokeng, Shiyan, Baoan District, Shenzhen Cochin, Kerala, India
This test report is valid for the tested samples only. It cannot be reproduced except in full without prior written consent of Shenzhen Microtest Co., Ltd. Tel:(86-755)88850135 Fax: (86-755) 88850136 Web: http://www.mtitest.com E-mail: [email protected] Address: 101, No. 7, Zone 2, Xinxing Industrial Park, Fuhai Avenue, Xinhe Community, Fuhai Street, Bao’ an District, Shenzhen, Guangdong, China. Test Report FCC ID:2AXEM-KQI043 Date of issue: Aug. 28, 2020 Report number: MTi20081408-2E1 Sample description: Wireless charger Mo d e l( s ) : KQI043, KQI043BK, KQI043BU, KQI043RD, KQIWH Applicant: Keytech Intelligent Technologies Limited Address: Keytech Industrial Park, Liaokeng, Shiyan, Baoan District, Shenzhen Date of test: Aug. 24, 2020 – Aug. 28, 2020 Shenzhen Microtest Co., Ltd. http://www.mtitest.com - Page 2 of 24 - Report No.: MTi20081408-2E1 Tel:(86-755)88850135 Fax: (86-755) 88850136 Web: http://www.mtitest.com E-mail: [email protected] Address: 101, No. 7, Zone 2, Xinxing Industrial Park, Fuhai Avenue, Xinhe Community, Fuhai Street, Bao’ an District, Shenzhen, Guangdong, China. Table of Contents 1 GENERAL INFORMATION ................................................................................................................................... 4 1.1 FEATURE OF EQUIPMENT UNDER TEST (EUT) ................................................................................................................... 4 1.2 TEST MODE .............................................................................................................................................................. 4 1.3 EUT TEST SETUP........................................................................................................................................................ 5 1.4 ANCILLARY EQUIPMENT .............................................................................................................................................. 5 2 SUMMARY OF TEST RESULT ............................................................................................................................... 6 2.1 OPERATION CHANNEL LIST ........................................................................................................................................... 6 2.2 TEST CHANNEL .......................................................................................................................................................... 6 3 TEST FACILITIES AND ACCREDITATIONS .............................................................................................................. 7 3.1 TEST LABORATORY ..................................................................................................................................................... 7 3.2 ENVIRONMENTAL CONDITIONS ..................................................................................................................................... 7 3.3 MEASUREMENT UNCERTAINTY ...................................................................................................................................... 7 3.4 TEST SOFTWARE ........................................................................................................................................................ 7 4 LIST OF TEST EQUIPMENT .................................................................................................................................. 8 5 TEST RESULTS ..................................................................................................................................................... 9 5.1 ANTENNA REQUIREMENT ............................................................................................................................................ 9 5.1.1 Standard requirement ................................................................................................................................. 9 5.1.2 EUT Antenna ............................................................................................................................................... 9 5.2 CONDUCTED EMISSION ............................................................................................................................................. 10 5.2.1 Limits ......................................................................................................................................................... 10 5.2.2 Test Procedures ......................................................................................................................................... 10 5.2.3 Test Setup .................................................................................................................................................. 10 5.2.4 Test Result ................................................................................................................................................. 10 5.3 RADIATED EMISSION ................................................................................................................................................. 15 5.3.1 Limits ......................................................................................................................................................... 15 5.3.2 Test Procedures ......................................................................................................................................... 16 5.3.3 Test Setup .................................................................................................................................................. 17 5.3.4 Test Result ................................................................................................................................................. 17 5.4 OCCUPIED BANDWIDTH............................................................................................................................................. 21 5.4.1 Test method ............................................................…
Text truncated - open the document above for the full version.
Model: KQI043 Radiated emission Conducted emission
| # | Rule Parts | Frequency Range | Power Output |
|---|---|---|---|
| 1 | 15C | 0.115 MHz - 0.205 MHz | - |