2AXFP-VICKER350SPortable power station

Hengke Energy (GuangDong) Co. Ltd
Portable power station - FCC ID 2AXFP-VICKER350S - Hengke Energy (GuangDong) Co. Ltd
Click to zoom

Application Details

Equipment Class
DCD - Part 15 Low Power Transmitter Below 1705 kHz
Date of Grant
Sep 10, 2020
Application Purpose
Original Equipment
Date of Application
Sep 10, 2020
Equipment Note
Portable power station
Frequency Range
0.11000000 - 0.20500000
Company
Hengke Energy (GuangDong) Co. Ltd
Country
China

Documents & Files

Select a file to view

Users Manual

↗

Attestation Statements

Cover Letter(s)

↗
↗

External Photos

↗

ID Label/Location Info

↗

Internal Photos

↗

RF Exposure Info

↗

Test Report

↗

Test Setup Photos

↗

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

Cover Letter(s)

Date: 04/17/2018 VCB_F-01: Operating Procedures Form – FCC Authorization v02 Page 1 of 1 Hengke Energy (GuangDong) Co. Ltd Federal Communications Commission Authorization and Evaluation Division 1435 Oakland Mills Road Columbia, MD 21046 Date: 2020/9/9 SUBJECT: FCC Application for (FCC ID: 2AXFP-VICKER350S) To Whom It May Concern: We, the undersigned, hereby authorize Alisa Feng in Shenzhen Huaxia Testing Technology Co., Ltd at 1F., Block A of Tongsheng Technology Building, Huahui Road, Dalang Street, Longhua District, Shenzhen, China on our behalf, to apply to the Federal Communications Commission on our equipment. Any and all acts carried out by Shenzhen Huaxia Testing Technology Co., Ltd on our behalf shall have the same effect as acts of our own. This is to advise that we are in full compliance with the Anti- Drug Abuse Act. We, the applicant, are not subject to a denial of federal benefits pursuant to Section 5301 of the Anti-Drug Act of 1988, 21 USC853a, and no party to the application is subject to a denial of federal benefits pursuant to that section. Sincerely, (Must be signed by the person that is listed on the FCC Website) Signature: Contact name: Leo Jia Company name: Hengke Energy (GuangDong) Co. Ltd Address: No.17,JinlingRoad,Zhangmutou,Dongguan Guangdong Province

Cover Letter(s)

Date: 04/17/2018 VCB_F-01: Operating Procedures Form – FCC Confidentiality v02 Page 1 of 1 Hengke Energy (GuangDong) Co. Ltd Federal Communications Commission Authorization and Evaluation Division Confidentiality Request regarding application for certification of FCC ID: 2AXFP-VICKER350S Pursuant to Sections 0.457 and 0.459 of the Commission’s Rules, we hereby request confidential treatment of information accompanying this application as outlined below: Exhibit Type File Name 1. Block Diagram, 2. Schematics, 3. Operational Description 1. 2AXFP-VICKER350S-Block diagram 2. 2AXFP-VICKER350S-SCH 3. 2AXFP-VICKER350S-Operational description The above materials contain trade secrets and proprietary information not customarily released to the public. The public disclosure of these materials may be harmful to the applicant and provide unjustified benefits to its competitors. The applicant understands that pursuant to Section 0.457 of the Rules, disclosure of this application and all accompanying documentation will not be made before the date of the Grant for this application. Pursuant to DA04-1705 June 15, 2004 of the Commission’s public notice, we also request temporary confidential treatment of information accompanying this application as outlined below for an initial period of xxxx (ie- “45”, “90” or “180”) days: Exhibit Type File Name N/A N/A Signature: Contact name: Leo Jia Company name: Hengke Energy (GuangDong) Co. Ltd Address: No.17,JinlingRoad,Zhangmutou,Dongguan Guangdong Province

External Photos

FCC ID: 2AXFP-VICKER350S FCC ID: 2AXFP-VICKER350S FCC ID: 2AXFP-VICKER350S

ID Label/Location Info

尺寸:27.14x18.84mm FCC ID: 2AXFP-VICKER350S Product Name: Protable power station Model No.: Vickers350 This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.

Internal Photos

FCC ID: 2AXFP-VICKER350S FCC ID: 2AXFP-VICKER350S FCC ID: 2AXFP-VICKER350S FCC ID: 2AXFP-VICKER350S FCC ID: 2AXFP-VICKER350S FCC ID: 2AXFP-VICKER350S FCC ID: 2AXFP-VICKER350S

RF Exposure Info

Shenzhen Huaxia Testing Technology Co., Ltd 1F., Block A of Tongsheng Technology Building, Huahui Road, Dalang Street, Longhua District, Shenzhen, China Telephone: +86-755-26648640 Fax: +86-755-26648637 Website: www.cqa-cert.com Report Template Version: V04 Report Template Revision Date: 2018-07-06 RF Exposure Evaluation Report The test report is effective only with both signature and specialized stamp, The result(s) shown in this report refer only to the sample(s) tested. Without written approval of CQA, this report can’t be reproduced except in full. Report No.: CQASZ20200800927E-02 Applicant: Hengke Energy (GuangDong) Co. Ltd Address of Applicant: No.17,JinlingRoad,Zhangmutou,Dongguan,Guangdong Province Equipment Under Test (EUT): Product: Protable power station Model No.: Vickers350, Vickers600, Vickers1000, G200, G300, G600, G1000, R85, R100, R150, R200, R300, R350, R500, R1000 Test Model No.: Vickers350 Brand Name: N/A FCC ID: 2AXFP-VICKER350S Standards: 47 CFR Part 1.1307 47 CFR Part 1.1310 KDB 680106 D01 RF Exposure Wireless Charging Base App v03 Date of Receipt: 2020-08-26 Date of Test: 2020-08-26 to 2020-09-09 Date of Issue: 2020-09-09 Test Result : PASS* *In the configuration tested, the EUT complied with the standards specified above Tested By: ( Tiny You ) Reviewed By: ( Sheek Luo ) Approved By: ( Jack Ai ) Shenzhen Huaxia Testing Technology Co., Ltd Report No.: CQASZ20200800927E-02 Page:2 of 11 1 Version Revision History Of Report Report No. Version Description Issue Date CQASZ20200800927E-02 Rev.01 Initial report 2020-09-09 Shenzhen Huaxia Testing Technology Co., Ltd Report No.: CQASZ20200800927E-02 Page:3 of 11 2 Contents Page 1 VERSION .....................................................................................................................................................................2 2 CONTENTS .................................................................................................................................................................3 3 GENERAL INFORMATION ......................................................................................................................................4 3.1 CLIENT INFORMATION ...............................................................................................................................................4 3.2 GENERAL DESCRIPTION OF EUT ...............................................................................................................................4 3.3 PRODUCT SPECIFICATION SUBJECTIVE TO THIS STANDARD ........................................................................................4 3.4 TEST ENVIRONMENT ..................................................................................................................................................5 3.5 DESCRIPTION OF SUPPORT UNITS ..............................................................................................................................5 3.6 TEST LOCATION .........................................................................................................................................................6 3.7 TEST FACILITY ..........................................................................................................................................................6 3.8 EQUIPMENT LIST .......................................................................................................................................................6 4 RF EXPOSURE EVALUATION ................................................................................................................................7 4.1 RF EXPOSURE COMPLIANCE REQUIREMENT ..............................................................................................................7 4.1.1 Limits ..............................................................................................................................................................7 4.1.2 Test Procedure ..............................................................................................................................................7 4.1.3 Test Setup......................................................................................................................................................8 4.1.4 Test Results ...................................................................................................................................................8 APPENDIX A: PHOTOGRAPHS OF TEST SETUP..................................................................................................... 11 Shenzhen Huaxia Testing Technology Co., Ltd Report No.: CQASZ20200800927E-02 Page:4 of 11 3 General Information 3.1 Client Information Applicant: Hengke Energy (GuangDong) Co. Ltd Address of Applicant: No.17,JinlingRoad,Zhangmutou,Dongguan,Guangdong Province Manufacturer: Hengke Energy (GuangDong) Co. Ltd Address of Manufacturer: No.17,JinlingRoad,Zhangmutou,Dongguan,Guangdong Province Factory: Hengke Energy (GuangDong) Co. Ltd Address of Factory: No.17,JinlingRoad,Zhangmutou,Dongguan,Guangdong Province 3.2 General Description of EUT Product Name: Protable power station Model No.: Vickers350, Vickers600, Vickers1000, G200, G300, G600, G1000, R85, R100, R150, R200, R300, R350, R500, R1000 Test Model No.: Vickers350 Brand Name: N/A Hardware Version: V1.0 Software Version: V1.0 EUT Power Supply: lithium battery: DC 14.8V, Input: DC 12.4~19V or AC 100~240V 50/60Hz 3.3 Product Specification subjective to this standard Equipment Category: Non-ISM frequency Operation Frequency range: 110kHz~205kHz Modulation Type: Induction Antenna Type: Induction coil Antenna Gain: 0dBi Power: Output: 10W(Max) Note: 1. In section 15.31(m), regards to the operating frequency range less 1 MHz. 2. Model No.: Vickers350, Vickers600, Vickers1000, G200, G300, G600, G1000, R85, R100, R150, R200, R300, R350, R500, R1000 Only the model Vickers350 was tested, since the electrical circuit…

Text truncated - open the document above for the full version.

Test Report

Shenzhen Huaxia Testing Technology Co., Ltd 1F., Block A of Tongsheng Technology Building, Huahui Road, Dalang Street, Longhua District, Shenzhen, China Telephone: +86-755-26648640 Fax: +86-755-26648637 Website: www.cqa-cert.com Report Template Version: V04 Report Template Revision Date: 2018-07-06 Test Report The test report is effective only with both signature and specialized stamp, The result(s) shown in this report refer only to the sample(s) tested. Without written approval of CQA, this report can’t be reproduced except in full. Report No.: CQASZ20200800927E-01 Applicant: Hengke Energy (GuangDong) Co. Ltd Address of Applicant: No.17,JinlingRoad,Zhangmutou,Dongguan,Guangdong Province Equipment Under Test (EUT): Product: Protable power station Model No.: Vickers350, Vickers600, Vickers1000, G200, G300, G600, G1000, R85, R100, R150, R200, R300, R350, R500, R1000 Test Model No.: Vickers350 Brand Name: N/A FCC ID: 2AXFP-VICKER350S Standards: 47 CFR Part 15, Subpart C Date of Receipt: 2020-08-26 Date of Test: 2020-08-26 to 2020-09-09 Date of Issue: 2020-09-09 Test Result: PASS* *In the configuration tested, the EUT complied with the standards specified above Tested By: ( Tiny You ) Reviewed By: ( Sheek Luo ) Approved By: ( Jack Ai ) Shenzhen Huaxia Testing Technology Co., Ltd Report No.: CQASZ20200800927E-01 Page:2 of 31 1 Version Revision History Of Report Report No. Version Description Issue Date CQASZ20200800927E-01 Rev.01 Initial report 2020-09-09 Shenzhen Huaxia Testing Technology Co., Ltd Report No.: CQASZ20200800927E-01 Page:3 of 31 2 Test Summary Test Item Test Requirement Test method Result Antenna Requirement 47 CFR Part 15, Subpart C Section 15.203 ANSI C63.10 2013 PASS AC Power Line Conducted Emission 47 CFR Part 15, Subpart C Section 15.207 ANSI C63.10 2013 PASS 20dB Occupied Bandwidth 47 CFR Part 15, Subpart C Section 15.215 ANSI C63.10 2013 PASS Radiated Emission , Radiated Spurious Emissions 47 CFR Part 15, Subpart C Section 15.209 ANSI C63.10 2013 PASS Shenzhen Huaxia Testing Technology Co., Ltd Report No.: CQASZ20200800927E-01 Page:4 of 31 3 Contents Page 1 VERSION .................................................................................................................................................................. 2 2 TEST SUMMARY .................................................................................................................................................... 3 3 CONTENTS .............................................................................................................................................................. 4 4 GENERAL INFORMATION ................................................................................................................................... 5 4.1 CLIENT INFORMATION .......................................................................................................................................... 5 4.2 GENERAL DESCRIPTION OF EUT .......................................................................................................................... 5 4.3 PRODUCT SPECIFICATION SUBJECTIVE TO THIS STANDARD .................................................................................. 5 4.4 TEST ENVIRONMENT ............................................................................................................................................ 6 4.5 DESCRIPTION OF SUPPORT UNITS ......................................................................................................................... 6 4.6 STATEMENT OF THE MEASUREMENT UNCERTAINTY ............................................................................................. 7 4.7 TEST LOCATION ................................................................................................................................................... 7 4.8 TEST FACILITY ..................................................................................................................................................... 7 4.9 DEVIATION FROM STANDARDS ............................................................................................................................. 7 4.10 OTHER INFORMATION REQUESTED BY THE CUSTOMER ........................................................................................ 7 4.11 EQUIPMENT LIST .................................................................................................................................................. 8 5 TEST RESULTS AND MEASUREMENT DATA ................................................................................................ 9 5.1 ANTENNA REQUIREMENT ..................................................................................................................................... 9 5.2 CONDUCTED EMISSIONS ..................................................................................................................................... 10 5.3 20DB OCCUPY BANDWIDTH ............................................................................................................................... 13 5.4 RADIATED SPURIOUS EMISSION & RESTRICTED BANDS ..................................................................................... 15 5.4.1 Spurious Emissions ................................................................................................................................ 15 6 PHOTOGRAPHS - EUT TEST SETUP .............................................................................................................. 20 6.1 RADIATED EMISSION .......................................................................................................................................... 20 6.2 CONDUCTED EMISSION ...................................................................................................................................... 21 7 PHOTOGRAPHS - EUT CONSTRUCTIONAL DETAILS ..........................................................................…

Text truncated - open the document above for the full version.

Test Setup Photos

FCC ID: 2AXFP-VICKER350S 1 Photographs - EUT Test Setup 1.1 Radiated Emission 9kHz~30MHz: 30MHz~1GHz: FCC ID: 2AXFP-VICKER350S 1.2 Conducted Emission

Contact Information

Applicant

Leo Jia
[email protected]+86-0769-89386595Fax: +86-0769-89386595

Test Firm

Shenzhen Huaxia Testing Technology Co., LtdJack Ai
[email protected]+8613902988375

Technical Specifications

#Rule PartsFrequency RangePower Output
115C0.11 MHz - 0.205 MHz-
Confidentiality
Long Term