Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.
OWNER’S MANUAL CHI LIFE UV LIGHT LAMP When the light is on! Please close the hood or stay away! Please read this manual carefully before use to avoid injuries! DO NOT STARE DIRECTLY AT THE LIGHT! CL1008 Owner’s Instructions Before operating the appliance, please read these instructions carefully and keep them for future reference FAROUK SYSTEMS, INC. 250 PENNBRIGHT DR. HOUSTON, TEXAS 77090 TEL: 281-876-2000 CHI.COM 3 FREQUENCY: 50/60 Hz TIMER: 30/60/120 Mins NM WAVELENGTHS: 253.7 UV LAMP STERILIZATION PRINCIPLE - This UV-C lamp operates at 254nm which is within the wavelength proven to destroy bacteria and viruses by altering the DNA of the cells harmful contaminants, even microorganisms naked to the human eye. SERVICE LIFE - 6,000 hours USE RANGE - Air sterilization for indoor or enclosed spaces SPACES PRODUCT DESCRIPTION: 1. This product is an indoor air germicidal lamp using a UV-C light source. 2. This product incorporates three movable side covers to control ultraviolet light exposure. They can be kept open when there are no people around, or all three side covers can be closed when people are nearby. Fans built inside the unit circulate the air in the room so that it passes through the germicidal chamber of the purifier to be decontaminated from microbes. SAFETY WARNINGS: 1. This product is limited to air sterilization indoors or enclosed spaces. Do not operate with covers open in public spaces. 2. UV-C light is harmful to the eyes, skin, plants and animals. Do not expose UV-C light to people, plants or pets. Do not stare at the UV-C light. 3. KEEP AWAY FROM CHILDREN. DO NOT ALLOW CHILDREN NEAR THE DEVICE OR ALLOW CHILDREN TO TOUCH OR PLAY WITH THE DEVICE. 4. This product is not waterproof. Do not expose to rain or wash with water or other liquids. 5. Make sure this machine works at the voltage required by this product. PRODUCT: CHI LIFE UV Lamp (CL1008) RATED VOLTAGE: 110-130VPOWER: 40W 4 GENERAL INFORMATION: timer button 5 OPERATION INSTRUCTIONS 1. Press the “Power On/Off” button. A red indicator light will turn on, and a “welcome” voice prompt will activate. 2. Press the “Power On/Off” button once again and a voice prompt will activate stating that the device will automatically turn on after 30 seconds. Please close the covers or open the covers and exit the room within the 30 seconds. “The lamp will turn on after 30 seconds. 3. Press the timer button to select 30 minutes, 1 hour or 2 hours. The unit will function for the period of time selected. 4. Press the “Power ON/Off” button to turn off the unit if it is operating. 5. Press the Fan button to turn the fan on or off. 6. Press the Timer button 4 (four) times to place the unit on standby mode. TIMING BUTTON: 1. First press the “Power On / Off” button, the red indicator light is on, and the voice pr ompt “Welcome to use a microcomputer ultraviolet germicidal lamp”: Then press the “Timer” key once, and the blue indicator light flashing corresponding to the “30 minute timer” voice guide (The indicator red light is always on) Press the “Power On / Off” button again, and you can hear voice prompt “UV disinfection and sterilization function is enabled, it will automatically turn on after 30 seconds, please close the covers or stay away”, and the fans and light will turn on at the same time after the voice prompt is completed . At this time, the working time of the UV light and fans is 30 minutes. When the 30 minutes is complete, the voice prompt” Thank you for your use, please unplug the power plug” which means this machine is turned off. 2. First press the “On / Off” key, the red indicator light is on, and the voice prompt “Welcome to use a microcomputer ultraviolet germicidal lamp”; then press the “Timer” key twice, and the voice prompt “Timer 1 hour” blue and green lights flash at the same time (The red indicator light is always on, then press the “Power On / Off” button, the voice prompt “UV disinfection and sterilization function is enabled, it will automatically turn on after 30 seconds, 6 please close the covers or stay away.” 30 seconds after the voice prompt is completed, the fans and light are turned on at the same time: At this time, the working time of the lamp and fans will be 1 hour. When the hour is completed, a voice prompt “Thank you for your use, please unplug the power plug”. The light and fans are all turned off. 3. First press the “Power On / Off” button, the red indicator light is on, and the voice prompt “Welcome to use a microcomputer ultraviolet germicidal lamp”; then press the “Timer” button three times, the voice prompt is “Timed 2 hours”, blue, green and red indicator lights flashing at the same time: Press the “Power On / Off” key again, and the voice prompt “UV disinfection and sterilization function is enabled, automatically turn on after 30 seconds, please close the covers or stay away”. After the voice prompt is completed,the fans and the light are turned on at the same time. At this time, the working time of the lamp and fans will be 2 hours. When the 2 hours are completed, the voice prompt “Thank you for your use, please unplug the power plug”. The lamp and fan are all turned off. 4. Press the “Timer” button four times in succession, the timer function is canceled, and the voice prompt “Timer Cancel” is displayed. This UV germicidal light returns to standby status. The fans will turn on or off when you hear the voice prompts “fan on” and “fan off”. REMOTE CONTROL: 1. The operation of the remote is the same as the controls on the panel. 2. The operation of the “Fan” button is the same as the panel control. 3. How to use the “open” button: When the “Power On/Off” button is turned on (the red indicator light is on), press the ”Open” button once, and a voice prompt will state that the unit sterilization function will automatically turn on after 30 seconds. This operates the same as pressing the On/Off button on the panel the second time. Please close the hood and exit the room. 7 4. When the “Power On …
Text truncated - open the document above for the full version.
Applicant Declaration Applicant Declaration Rev:0.0 SGS North America Inc. 620 Old Peachtree Road SUITE 100 Suwanee, Georgia 30024 United States Applicant Legal Business Name Ningbo UV Light & Electricity Co., Ltd. Address No. 99 Huandao West Rd., Xiexi Industrial Zone, Daxie Development Zone, Ningbo City Grantee Code 2AXHI FCC ID 2AXHIUVLAMPTDZ-101 Authorized Contact Name Matt Wang Contact Email [email protected] Contact Phone +86 57486766682 I, the undersigned, certify that I am an authorized signatory for the Applicant and therefore declare; a) in accordance with 47CFR2.911(d), all of the statements herein and the exhibits attached hereto are true and correct to the best of my knowledge and belief. b) in accepting a Grant of Equipment Authorization issued by a TCB, under the authority of the FCC, as a result of the representations made in this application, the Applicant is responsible for: (1) labeling the equipment with the exact FCC ID as specified in this application, (2) compliance statement labeling pursuant to the applicable rules, (3) compliance of the equipment with the applicable technical rules, c) if the Applicant is not the actual manufacturer of the equipment, appropriate arrangements have been made with the manufacturer to ensure that production units of this equipment will continue to comply with the FCC’s technical requirements. d) in accordance with 47 CFR 2.909 and KDB394321, the Applicant has read, understood and agrees to accept that they are the responsible party and agree to abide by their responsibilities as specified under 47 CFR 2.909 and KDB394321. e) in accordance with ISO17065, FCC KDB641163, FCC KDB610077, KDB394321 and RSP-100, the Applicant has read, understood, accepts and agrees to abide by the post market surveillance requirements. (1) the Applicant understands, accepts and agrees that a sample may be requested for surveillance testing. (2) the Applicant shall make provisions to always have a production sample available upon request by SGS, FCC and/or ISED. (3) the Applicant shall, upon request by SGS, at the Applicant’s expense, provide a production sample of the requested product to SGS, FCC and/or ISED as instructed. The sample shall include all support devices, cables, software, accessories or other hardware or software required for evaluation, review, certification and audit surveillance of products certified by SGS. f) neither the Applicant nor any party to the application is subject to a denial of Federal benefits, that includes FCC benefits, pursuant to Section 5301 of the Anti-Drug Abuse Act of 1988, 21 U.S.C. §862 because of a conviction for possession or distribution of a controlled substance. See 47CFR 1.2002(b) for the definition of a “party” for these purposes. g) the Applicant has read, understood, accepts and agrees to abide by the SGS North America, Inc.(TCB) terms and conditions. Link to CFRs: https://www.fcc.gov/wireless/bureau-divisions/technologies-systems-and-innovation-division/rules-regulations-title-47 Link to KDBs: https://apps.fcc.gov/oetcf/kdb/index.cfm Link to RSP-100: https://www.ic.gc.ca/eic/site/smt-gst.nsf/eng/sf01130.html Applicant Signature: Date:2020-09-08 Print Name: Matt Wang Title: Sales *NOTE: This declaration cannot be signed by an Agent, it shall be signed by an authorized person listed in the FCC database
Ningbo UV Light & Electricity Co., Ltd. Date: 2020-09-08 TO: Federal Communication Commission Equipment Authorization Branch 7435 Oakland Mills Road Columbia, MID 21046 Regarding:FCC ID: 2AXHIUVLAMPTDZ-101 To whom it may concern: We, the undersigned, hereby authorize Parlam Zhan to act on our behalf in all manners relating to application for equipment authorization with respect to the FCC ID above, including signing of all documents relating to these matters. Any and all acts carried out by the agent on our behalf shall have the same effect as acts of our own. We, the undersigned, hereby certify that we are not subject to a denial of federal benefits, that includes FCC benefits, pursuant to Section 5301 of the Anti-Drug Abuse Act of 1988, 21 U.S.C. 853(a). Where our agent signs the application for certification on our behalf, I acknowledge that all responsibility for complying with the terms and conditions for Certification, as specified by SGS North America, Inc., still resides with <<Ningbo UV Light & Electricity Co., Ltd.>>. This authorization is valid until further written notice from the applicant. Name (Printed): Matt Wang Title: Sales Signature: On behalf of Company: Ningbo UV Light & Electricity Co., Ltd. Telephone: +86 574 8676 6682
Ningbo UV Light & Electricity Co., Ltd. To: SGS North America Inc. 620 Old Peachtree Road SUITE 100 Suwanee, Georgia United States From: Ningbo UV Light & Electricity No. 99 Huandao West Rd., Xiexi Industrial Zone, Daxie Development Zone Ningbo City, Zhejiang, China Regarding: Confidentiality Request regarding application for FCC ID 2AXHIUVLAMPTDZ-101 LONG TERM CONFIDENTIALITY Pursuant to 47 CFR Section 0.459 and 0.457 of the commission’s rules, the applicant hereby request confidential treatment of the documents listed below, associated with the certification application referenced above. Schematic(s) Block Diagrams Operational Descriptions The documents above contain proprietary information not released to the public. Public disclosure of this information may prove harmful to the business of the applicant. Sincerely, Signature: Printed Name (on file with the FCC associated with the Grantee Code): Matt Wang Title: Sales Company Name: Ningbo UV Light & Electricity Co., Ltd.
SGS-CSTC Standards Technical Services Co., Ltd. Shanghai Branch Page: 1 of 2 Page 1 of 2 External Photos Applicant: Ningbo UV Light & Electricity Co., Ltd. Address of Applicant: No. 99 Huandao West Rd., Xiexi Industrial Zone, Daxie Development Zone, Ningbo City, Zhejiang, China. Equipment Under Test (EUT): Product Name: UV LAMP REMOTE Model No.: TDZ-101R SGS-CSTC Standards Technical Services Co., Ltd. Shanghai Branch Page: 2 of 2 Page 2 of 2 End
Label & label location
SGS-CSTC Standards Technical Services Co., Ltd. Shanghai Branch Page: 1 of 2 Page 1 of 2 Internal Photos Applicant: Ningbo UV Light & Electricity Co., Ltd. Address of Applicant: No. 99 Huandao West Rd., Xiexi Industrial Zone, Daxie Development Zone, Ningbo City, Zhejiang, China. Equipment Under Test (EUT): Product Name: UV LAMP REMOTE Model No.: TDZ-101R SGS-CSTC Standards Technical Services Co., Ltd. Shanghai Branch Page: 2 of 2 Page 2 of 2 End
SGS-CSTC Standards Technical Services Co., Ltd. Shanghai Branch Report No.: SHEM200800703601 Page: 1 of 19 Parlam Zhan E&E Section Manager The manufacturer should ensure that all products in series production are in conformity with the product sample detailed in this report. If the product in this report is used in any configuration other than that detailed in the report, the manufacturer must ensure the new system complies with all relevant standards. Any mention of SGS International Electrical Approvals or testing done by SGS International Electrical Approvals in connection with, distribution or use of the product described in this report must be approved by SGS International Electrical Approvals in writing. 1 Cover Page RF REPORT Application No.: SHEM2008007036CR FCC ID: 2AXHIUVLAMPTDZ-101 Applicant: Ningbo UV Light & Electricity Co., Ltd. Address of Applicant: No. 99 Huandao West Rd., Xiexi Industrial Zone, Daxie Development Zone, Ningbo City, Zhejiang, China. Manufacturer: Ningbo UV Light & Electricity Co., Ltd. Address of Manufacturer: No. 99 Huandao West Rd., Xiexi Industrial Zone, Daxie Development Zone, Ningbo City, Zhejiang, China. Factory: Ningbo UV Light & Electricity Co., Ltd. Address of Factory: No. 99 Huandao West Rd., Xiexi Industrial Zone, Daxie Development Zone, Ningbo City, Zhejiang, China. Equipment Under Test (EUT): EUT Name: UV LAMP REMOTE Model No.: TDZ-101R Trade mark: Standard(s) : 47 CFR Part 15, Subpart C 15.231 Date of Receipt: 2020-08-21 Date of Test: 2020-08-26 to 2020-09-18 Date of Issue: 2020-09-21 Test Result: Pass* * In the configuration tested, the EUT complied with the standards specified above. SGS-CSTC Standards Technical Services Co., Ltd. Shanghai Branch Report No.: SHEM200800703601 Page: 2 of 19 Revision Record Version Description Date Remark 00 Original 2020-09-21 / Authorized for issue by: Bill Wu / Project Engineer Parlam Zhan /Reviewer SGS-CSTC Standards Technical Services Co., Ltd. Shanghai Branch Report No.: SHEM200800703601 Page: 3 of 19 2 Test Summary Test Item FCC Requirement Test method Result Antenna Requirement Part 15.203 / PASS Conducted Emission Part 15.207 ANSI C63.10 (2013) Section 6.2 N/A Field Strength of the Fundamental Part 15.231 (b ) ANSI C63.10 (2013) Section 6.4 PASS Radiated Spurious emissions Part 15.209 15.231(b) ANSI C63.10 (2013) Section 6.4&6.5&6.6 PASS 20dB Bandwidth Part 15.231 (c) ANSI C63.10 (2013) Section 6.9.2 PASS Dwell Time Part 15.231 (a ) ANSI C63.10 (2013) Section 7.8.4 PASS N/A: Not applicable. Please refer to Section 6.2 of this report for details. SGS-CSTC Standards Technical Services Co., Ltd. Shanghai Branch Report No.: SHEM200800703601 Page: 4 of 19 3 Contents Page 1 COVER PAGE .............................................................................................................................................1 2 TEST SUMMARY ........................................................................................................................................3 3 CONTENTS ..................................................................................................................................................4 4 GENERAL INFORMATION .......................................................................................................................5 4.1 GENERAL DESCRIPTION OF E.U.T..............................................................................................................5 4.2 TECHNICAL SPECIFICATIONS: ....................................................................................................................5 4.3 DESCRIPTION OF SUPPORT UNITS ..............................................................................................................5 4.4 TEST LOCATION .......................................................................................................................................5 4.5 TEST FACILITY .........................................................................................................................................6 4.6 MEASUREMENT UNCERTAINTY .................................................................................................................6 5 EQUIPMENTS USED DURING TEST .......................................................................................................7 6 TEST RESULTS AND MEASUREMENT DATA .......................................................................................8 6.1 ANTENNA REQUIREMENT ..........................................................................................................................8 6.2 CONDUCTED EMISSIONS AT AC POWER LINE (150KHZ-30MHZ) ................................................................9 6.2.1 E.U.T. Operation .............................................................................................................................9 6.2.2 Test Setup Diagram..........................................................................................................................9 6.2.3 Measurement Procedure and Data ................................................................................................ 10 6.3 SPURIOUS EMISSIONS.............................................................................................................................. 11 6.3.1 Field Strength of the Fundamental Signal ....................................................................................... 13 6.3.2 Spurious Emissions ........................................................................................................................ 14 6.4 20DB BANDWIDTH ................................................................................................................................. 17 6.5 DWELL TIME .......................................................................................................................................... 18 7 TEST SETUP PHOTOGRAPHS ..........................................................…
Text truncated - open the document above for the full version.
SGS-CSTC Standards Technical Services Co., Ltd. Shanghai Branch Page: 1 of 4 Page 1 of 4 Test Setup Photos-FCC Applicant: Ningbo UV Light & Electricity Co., Ltd. Address of Applicant: No. 99 Huandao West Rd., Xiexi Industrial Zone, Daxie Development Zone, Ningbo City, Zhejiang, China. Equipment Under Test (EUT): Product Name: UV LAMP REMOTE Model No.: TDZ-101R SGS-CSTC Standards Technical Services Co., Ltd. Shanghai Branch Page: 2 of 4 Page 2 of 4 1 Contents Page 1 CONTENTS............................................................................................................... 2 2 EQUIPMENT UNDER TEST PICTURES ............................................................ 3 2.1 Radiated Emission Test Setup .......................................................................... 3 SGS-CSTC Standards Technical Services Co., Ltd. Shanghai Branch Page: 3 of 4 Page 3 of 4 2 EQUIPMENT UNDER TEST PICTURES 2.1 Radiated Emission Test Setup 30MHz to 1GHz Above 1GHz SGS-CSTC Standards Technical Services Co., Ltd. Shanghai Branch Page: 4 of 4 Page 4 of 4 Zoom: End
588 West Jindu Road, Xinqiao, Songjiang · ShangHai · China
| # | Rule Parts | Frequency Range | Power Output |
|---|---|---|---|
| 1 | 15C | 433.92 MHz - 433.92 MHz | - |