Zero FCC Statement This device complies with part 15 and part 18 of the FCC Rules. Operation is Subject To the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. Changes or modifications not explicitly approved by the party responsible for compliance could void the user's authority to operate this equipment. Note: this equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 and part 18 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures: • Reorient or relocate the receiving antenna. • Increase the separation between the equipment and receiver. • Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. • Consult the dealer or an experienced radio/TV technician for help. The equipment complies with FCC radiation exposure limits set forth for an uncontrolled environment. During the operation of device a distance of 15 cm surrounding the device and 20 cm above the top surface of the device must be respected. This device complies with Part 18 of the FCC Rules. This equipment generates uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures: ●Increase the separation between the equipment and any other radio device. ●Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
ZeroInternationalLimited OfficeofEngineeringTechnology FederalCommunicationsCommission 7435OaklandMillsRoad Columbia,MD21046 USA Date:2020-10-30 Subject;RequestforConfidentiality FCCID:2AXIQ-AP20A1 ToWhomItMayConcern, PursuanttotheprovisionsoftheCommission’srulesTitle47Sections§0.457and§0.459,we arerequestingtheCommissiontowithholdthefollowingattachment(s)asconfidential documentsfrompublicdisclosureindefinitely. Thesedocumentscontaindetailedsystemandequipmentdescriptionsandareconsideredas proprietaryinformationinoperationoftheequipment.Thepublicdisclosureofthesedocuments mightbeharmfultoourcompanyandwouldgivecompetitorsanunfairadvantageinthemarket. SchematicDiagram BlockDiagram OperationalDescription Inadditionaltoabovementioneddocuments,inordertocomplywiththemarketingregulations inTitle47CFR§2.803andtheimportationrulesinTitle47CFR§2.1204,whileensuringthat businesssensitiveinformationremainsconfidentialuntiltheactualmarketingofnewly authorizeddevices,werequestShortTermConfidentialityofthefollowingattachment(s); ExternalPhotos TestSetupPhotos InternalPhotos UserManual For45days,pursuanttoPublicNoticeDA04-1705. OR For180dayspursuanttoKDB726920D01. Itisourunderstandingthatallmeasurementtestreports,FCCIDlabelformatand correspondenceduringthecertificationreviewprocesscannotbegrantedasconfidential documentsandthisinformationwillbeavailableforpublicreviewoncethegrantofequipment authorizationisissued. Sincerely, Signature: Name:LuJiang Title:ProductManager
SHENZHENLCSCOMPLIANCETESTINGLABORATORYLTD.FCCID:2AXIQ-AP20A1 Thisreportshallnotbereproducedexceptinfull,withoutthewrittenapprovalofShenzhenLCSComplianceTestingLaboratoryLtd. Page1of3 ExternalPhotosoftheEUT Fig.1 Fig.2 SHENZHENLCSCOMPLIANCETESTINGLABORATORYLTD.FCCID:2AXIQ-AP20A1 Thisreportshallnotbereproducedexceptinfull,withoutthewrittenapprovalofShenzhenLCSComplianceTestingLaboratoryLtd. Page2of3 Fig.3 Fig.4 SHENZHENLCSCOMPLIANCETESTINGLABORATORYLTD.FCCID:2AXIQ-AP20A1 Thisreportshallnotbereproducedexceptinfull,withoutthewrittenapprovalofShenzhenLCSComplianceTestingLaboratoryLtd. Page3of3 Fig.5 Fig.6
SHENZHENLCSCOMPLIANCETESTINGLABORATORYLTD.FCCID:2AXIQ-AP20A1 Thisreportshallnotbereproducedexceptinfull,withoutthewrittenapprovalofShenzhenLCSComplianceTestingLaboratoryLtd. Page 1 of1 LabelandLocation Size:L:3.0cm*W:2.0cm Material:Tagboard Glue:adhesivesticker Fontcolor:White Labelcolor:Black LabelLocation
SHENZHENLCSCOMPLIANCETESTINGLABORATORYLTD.FCCID:2AXIQ-AP20A1 Thisreportshallnotbereproducedexceptinfull,withoutthewrittenapprovalofShenzhenLCSComplianceTestingLaboratoryLtd. Page1of3 InternalPhotosoftheEUT Fig.1 Fig.2 SHENZHENLCSCOMPLIANCETESTINGLABORATORYLTD.FCCID:2AXIQ-AP20A1 Thisreportshallnotbereproducedexceptinfull,withoutthewrittenapprovalofShenzhenLCSComplianceTestingLaboratoryLtd. Page2of3 Fig.3 Fig.4 CoilAntenna SHENZHENLCSCOMPLIANCETESTINGLABORATORYLTD.FCCID:2AXIQ-AP20A1 Thisreportshallnotbereproducedexceptinfull,withoutthewrittenapprovalofShenzhenLCSComplianceTestingLaboratoryLtd. Page3of3 Fig.5
SHENZHENLCSCOMPLIANCETESTINGLABORATORYLTD.FCCID:2AXIQ-AP20A1 ___________________________________________________________________________ Thisreportshallnotbereproducedexceptinfull,withoutthewrittenapprovalofShenzhenLCSComplianceTestingLaboratoryLtd. Page 1 of 10 RFExposureEvaluationReport 1.ProductInformation FCCID:2AXIQ-AP20A1 ProductNameZeroWirelessQiPad ModelNumberZERO-QI-3000 PowerSupply Input:5V2V(USB-C+Pinx2) Output:5V2V(USB-C),QI:5W ProductCapacity:Type-C1800mAh(5V/2A) Qi1500mAh(5V1V) CellCapacity:3000mAh/3.8V/11.4Wh ModulationTypeCW(ContinuousWave) FrequencyRange110KHz-205KHz OperationFrequency128.0KHz AntennaTypeCoilAntenna Hardwareversion/ Softwareversion/ AccessoriesMobilephone ExposurecategoryGeneralpopulation/uncontrolledenvironment EUTTypeProductionUnit DeviceTypeMobileDevice 2.EvaluationMethod PerKDB680106D01Section3.RFExposureRequirements; 1)ConsumerwirelesspowertransferdevicesapprovedunderPart18insomecaseshavetodemonstrate compliancewithRFexposurerequirements.Thepotentialforexposuremustbeassessedaccordingto theoperatingconfigurationsofthewirelesssystemandtheexposureconditionsofusersand bystanders.RFexposuremustbeevaluatedwiththeclientdevice(s)beingchargedbytheprimaryat maximumoutputpower.TheRFexposurerequirementsmustbedeterminedinconjunctionwiththe deviceoperatingcharacteristics,accordingtothemobileandportableexposurerequirementsin Section2.1091andSection2.1093oftherules.SARandMPElimitsdonotcoverthefrequencyrange forwirelesspowertransferapplicationswhichoperatebelow100kHzand300kHzrespectively; therefore,RFexposurecomplianceneedstobedeterminedwithrespectto1.1307(c)and(d)ofthe FCCrules. 2)Basedonthedesignandimplementationofthepowertransferapplication,itmustbeclearlyidentified ifmobileorportableRFexposureconditionsapply.Devicesthatareinstalledtoprovideseparationof atleast20cmfromusersandbystandersmayqualifyformobileexposureconditions.Forsome conditionswhereusersandbystandersmaybeexposedatcloserthan20cm,section2.1091(d)(4)of therulesmayapply. 3)Fordevicesdesignedfortypicaldesktopapplications,suchawirelesschargingpads,RFexposure evaluationshouldbeconductedassumingauserseparationdistanceof15cm.EandHfieldstrength measurementsornumericalmodelingmaybeusedtodemonstratecompliance.Measurementsshould bemadefromallsidesandthetopoftheprimary/clientpair,withthe15cmmeasuredfromthe centeroftheprobe(s)totheedgeofthedevice.Emissionsbetween100kHzto300kHzshouldbe SHENZHENLCSCOMPLIANCETESTINGLABORATORYLTD.FCCID:2AXIQ-AP20A1 ___________________________________________________________________________ Thisreportshallnotbereproducedexceptinfull,withoutthewrittenapprovalofShenzhenLCSComplianceTestingLaboratoryLtd. Page 2 of 10 assessedversusthelimitsat300kHzinTable1ofSection1.1310:614V/mand1.63A/m.AKDB inquiryisrequiredtodeterminetheapplicableexposurelimitsbelow100kHz. 4)Portableexposureconditionsfrom100kHzto6GHzaredeterminedwithrespecttoSARrequirements. ExistingSARsystemsandtestproceduresaregenerallyintendedformeasurementsabove100MHz. Whilenumericalmodelingcanbeanalternative,theconstraintsofsubstantialcomputational resourcesatlowfrequenciescouldintroducefurtherlimitations.Underthesecircumstances,including operationsbelow100kHz,theCommissionmayconsideracombinationofanalyticalanalysis,field strength,radiatedandconductedpowermeasurements,inconjunctionwithsomelimitednumerical modelingtoassesscompliance. 5)Dependingontheoperatingfrequency,existingSARandMPEmeasurementproceduresmaybe adaptedtoevaluatewirelesspowertransferdevicesforcompliancewithrespecttomobileorportable exposureconditions.IfthegranteeoritstestlabhaveanyquestionsregardingRFexposureevaluation theyshouldcontacttheFCCLaboratorywithsufficientsystemoperatingconfigurationdetailsto determineifRFexposureevaluationisnecessaryand,ifrequired,howtoapplyspecifictestprocedures. Below100MHz,whenSARtestingisrequiredandthedeviceisoperatingatcloseproximitytopersons, informationondevicedesign,implementation,operatingconfigurations,exposureconditionsofusers andbystandersareneededtodeterminetheevaluationandtestingrequirements.Inaddition,the influenceofnearbyobjectsmayalsoneedconsiderationaccordingtothewirelesspowertransfer systemimplementation;forexample,theeffectsofplacingthedevice,itscoilsorradiatingelements onornearmetallicsurfaces 3.EvaluationLimit 3.1Referevaluationmethod ANSIC95.1–1999:IEEEStandardforSafetyLevelswithRespecttoHumanExposuretoRadioFrequency ElectromagneticFields,3kHzto300GHz. FCCKDBpublication680106D01RFExposureWirelessChargingAppsv03:RFExposureConsiderations forLowPowerConsumerWirelessPowerTransferApplications FCCCFR47part11.1310:Radiofrequencyradiationexposurelimits. FCCCFR47part22.1091:Radiofrequencyradiationexposureevaluation:mobiledevices FCCCFR47part18.107:Indusial,Scientific,andMedicalEquipment 3.2Limit LimitsforMaximumPermissibleExposure(MPE)/ControlledExposure Frequency Range(MHz) ElectricField Strength(V/m) MagneticField Strength(A/m) PowerDensity (mW/cm²) AveragingTime (minute) LimitsforOccupational/ControlledExposure 0.3-3.06141.63*1006 3.0-301842/f4.89/f*900/f 2 6 30-30061.40.1631.06 300-1,500//f/3006 1,500-100,000//56 SHENZHENLCSCOMPLIANCETESTINGLABORATORYLTD.FCCID:2AXIQ-AP20A1 ___________________________________________________________________________ Thisreportshallnotbereproducedexceptinfull,withoutthewrittenapprovalofShenzhenLCSComplianceTestingLaboratoryLtd. Page 3 of 10 LimitsforMaximumPermissibleExposure(MPE)/UncontrolledExposure Frequency Range(MHz) ElectricField Strength(V/m) MagneticField Strength(A/m) PowerDensity (mW/cm²) AveragingTime (minute) LimitsforGeneralPopulation/UncontrolledExposure 0.3-1.346141.63*10030 1.34-30824/f2.19/f*180/f 2 30 30-30027.50.0730.230 300-1,500//f/150030 1,500-100,000//1.030 F=frequencyinMHz *=Plane-waveequivalentpowerdensity AccordingtoFCCKDB680106D01Section3.RFExposureRequirementsclause3theEmission-Limits inthefrequencyrangefrom100KHzto300KHzshouldbeassessedversusthelimitsat300KHzin Table1ofCFR47–Section1.310asfollowing(measureddistanceshallbe15cmfromthecenterof theprobetotheedgeofth…
Text truncated - open the document above for the full version.
SHENZHENLCSCOMPLIANCETESTINGLABORATORYLTD.FCCID:2AXIQ-AP20A1ReportNo.:LCS200813045AEA Thisreportshallnotbereproducedexceptinfull,withoutthewrittenapprovalofShenzhenLCSComplianceTestingLaboratoryLtd. Page1of22 FCCTESTREPORT For ZeroInternationalLimited ZeroWirelessQiPad TestModel:ZERO-QI-3000 AdditionalModelNo.:N/A Preparedfor:ZeroInternationalLimited Address: 20955PathfinderRoad,Suite100DiamondBar,CA91765, USA Preparedby:ShenzhenLCSComplianceTestingLaboratoryLtd. Address: 101,201BldgA&301BldgC,JujiIndustrialParkShajing Street,BaoanDistrict,Shenzhen,China Tel:(+86)755-82591330 Fax:(+86)755-82591332 Web:www.LCS-cert.com Mail:[email protected] Dateofreceiptoftestsample:August17,2020 Numberoftestedsamples:1 Serialnumber:Prototype DateofTest:August17,2020~August21,2020 DateofReport:August31,2020 SHENZHENLCSCOMPLIANCETESTINGLABORATORYLTD.FCCID:2AXIQ-AP20A1ReportNo.:LCS200813045AEA Thisreportshallnotbereproducedexceptinfull,withoutthewrittenapprovalofShenzhenLCSComplianceTestingLaboratoryLtd. Page2of22 FCCTESTREPORT FCCCFR47PART18 ReportReferenceNo......................:LCS200813045AEA DateOfIssue......................................:August31,2020 TestingLaboratoryName..............:ShenzhenLCSComplianceTestingLaboratoryLtd. Address................................................: 101,201BldgA&301BldgC,JujiIndustrialParkShajingStreet, BaoanDistrict,Shenzhen,China TestingLocation/Procedure............ : FullapplicationofHarmonisedstandards■PartialapplicationofHarmonisedstandards□ Otherstandardtestingmethod□ Applicant’sName.............................:ZeroInternationalLimited Address................................................:20955PathfinderRoad,Suite100DiamondBar,CA91765,USA TestSpecification Standard..............................................:FCCCFR47PART18 TestReportFormNo.........................:LCSEMC-1.0 TRFOriginator....................................:ShenzhenLCSComplianceTestingLaboratoryLtd. MasterTRF.........................................:Dated2011-03 ShenzhenLCSComplianceTestingLaboratoryLtd.Allrightsreserved. Thispublicationmaybereproducedinwholeorinpartfornon-commercialpurposesaslongasthe ShenzhenLCSComplianceTestingLaboratoryLtd.isacknowledgedascopyrightownerandsourceof thematerial.ShenzhenLCSComplianceTestingLaboratoryLtd.takesnoresponsibilityforandwillnot assumeliabilityfordamagesresultingfromthereader'sinterpretationofthereproducedmaterialdueto itsplacementandcontext. TestItemDescription.....................:ZeroWirelessQiPad TradeMark..........................................:ZERO TestModel...........................................:ZERO-QI-3000 PowerSupply......................................: PleaseReferToPage6 Result..................................................: Positive Compiledby:Supervisedby:Approvedby: ScentHu/FileadministratorsJinWang/TechniqueprincipalGavinLiang/Manager SHENZHENLCSCOMPLIANCETESTINGLABORATORYLTD.FCCID:2AXIQ-AP20A1ReportNo.:LCS200813045AEA Thisreportshallnotbereproducedexceptinfull,withoutthewrittenapprovalofShenzhenLCSComplianceTestingLaboratoryLtd. Page3of22 FCCTESTREPORT TestResultPositive Thetestreportmerelycorrespondstothetestsample. Itisnotpermittedtocopyextractsofthesetestresultwithoutthewrittenpermissionofthetest laboratory. TestReportNo.:LCS200813045AEA August31,2020 Dateofissue TestModel..............................:ZERO-QI-3000 EUT.........................................:ZeroWirelessQiPad Applicant...............................:ZeroInternationalLimited Address..................................:20955PathfinderRoad,Suite100DiamondBar,CA91765,USA Telephone...............................:/ Fax..........................................:/ Manufacturer........................:ZhangzhouAucopoEnergyTechnologyCo.,Ltd Address...................................: No.198,Highway319,Jingcheng,Nanjing,Zhangzhou,Fujian Province,PR.China Telephone...............................:/ Fax..........................................:/ Factory...................................:ZhangzhouAucopoEnergyTechnologyCo.,Ltd Address...................................: No.198,Highway319,Jingcheng,Nanjing,Zhangzhou,Fujian Province,PR.China Telephone...............................:/ Fax..........................................:/ SHENZHENLCSCOMPLIANCETESTINGLABORATORYLTD.FCCID:2AXIQ-AP20A1ReportNo.:LCS200813045AEA Thisreportshallnotbereproducedexceptinfull,withoutthewrittenapprovalofShenzhenLCSComplianceTestingLaboratoryLtd. Page4of22 RevisionHistory RevisionIssueDateRevisionsRevisedBy 000August31,2020InitialIssueGavinLiang SHENZHENLCSCOMPLIANCETESTINGLABORATORYLTD.FCCID:2AXIQ-AP20A1ReportNo.:LCS200813045AEA Thisreportshallnotbereproducedexceptinfull,withoutthewrittenapprovalofShenzhenLCSComplianceTestingLaboratoryLtd. Page5of22 TABLEOFCONTENTS 1.GENERALINFORMATION.........................................................................................................6 1.1DescriptionofDevice(EUT)...............................................................................................................6 1.2SupportequipmentList........................................................................................................................6 1.3ExternalI/OCable................................................................................................................................6 1.4DescriptionofTestFacility..................................................................................................................6 1.5StatementoftheMeasurementUncertainty.....................................................................................7 1.6MeasurementUncertainty...................................................................................................................7 1.7DescriptionofTestModes..................................................................................................................7 2.TESTMETHODOLOGY......................................................................................................…
Text truncated - open the document above for the full version.
SHENZHENLCSCOMPLIANCETESTINGLABORATORYLTD.FCCID:2AXIQ-AP20A1 _______________________________________________________________________________________________ Thisreportshallnotbereproducedexceptinfull,withoutthewrittenapprovalofShenzhenLCSComplianceTestingLaboratoryLtd. Page 1 of 2 AppendixA PhotographsofTestSetup ConductedEmission-ACadapterchargemode RadiatedEmissionbelow30MHz SHENZHENLCSCOMPLIANCETESTINGLABORATORYLTD.FCCID:2AXIQ-AP20A1 _______________________________________________________________________________________________ Thisreportshallnotbereproducedexceptinfull,withoutthewrittenapprovalofShenzhenLCSComplianceTestingLaboratoryLtd. Page 2 of 2 RadiatedEmissionBelow1GHz
| # | Rule Parts | Frequency Range | Power Output |
|---|---|---|---|
| 1 | 18 | 0.11 MHz - 0.205 MHz | - |

Zero Home Dock
Equipment Class
8CC - Part 18 Consumer Device