FCCID.CO- FCC ID Database
HomeCompaniesEquipment ClassesSearch

© 2026 FCC ID Database. All rights reserved.

AboutContactData sourced from FCC public records
  1. Home/
  2. Texas Instruments Incorporated/
  3. 2AXJSIWRL6432BAFCLI

2AXJSIWRL6432BAFCLICertified 60GHz mmWave Radar Module For Motion and Presence Detection

Texas Instruments Incorporated

Application Details

Equipment Class
FDS - Part 15 Field Disturbance Sensor
Date of Grant
Jul 23, 2026
Application Purpose
Original Equipment
Equipment Note
Certified 60GHz mmWave Radar Module For Motion and Presence Detection
Frequency Range
57000.00000000 - 59400.00000000
Company
Texas Instruments Incorporated
Country
United States

Documents & Files

Select a file to view

Attestation Statements

↗
↗

Cover Letter(s)

↗
↗
↗

ID Label/Location Info

↗

RF Exposure Info

↗

Test Report

↗

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

Attestation Statements

TI Information – Selective Disclosure Texas Instruments, Incorporated 12500 TI Boulevard Dallas, TX 75243 Federal Communications Commission 7435 Oakland Mills Road Columbia MD 21046 Subject: Certification designating a U.S. agent for service of process pursuant to Part 2.911(d)(7) To whom it may concern, Texas Instruments Incorporated, Grantee Code: 2AXJS (“the applicant”) as required by section 2.911(d)(7), will also serve as the agent for service of process for the above referenced FCC Grantee Code. The service of process includes, but is not limited to, delivery of any correspondence, notices, orders, decisions, and requirements of administrative, legal, or judicial process related to Commission proceedings. The applicant acknowledges that they will maintain an agent for service of process in the United States for no less than one year after either the grantee has permanently terminated all marketing and importation of the applicable equipment within the U.S., or the conclusion of any Commission-related administrative or judicial proceeding involving the equipment, whichever is later. The applicant further acknowledges their responsibility to inform the FCC whenever the following agent information changes. Company Name: Texas Instruments Incorporated Company US Address: 12500 TI Boulevard, Dallas, Texas, 75243 United States Contact Person: Yariv Raveh Email: [email protected] Telephone number: 214-479-1184 FRN: 0038390621 Sincerely yours, Signed by the Applicant Yariv Raveh Title: Vice President, Embedded Processing - Radar Email: [email protected] Date: May 14, 2026 Docusign Envelope ID: 420AB8D5-CA90-850D-810B-C468478821C9

Attestation Statements

TI Information – Selective Disclosure Texas Instruments, Incorporated 12500 TI Boulevard Dallas, TX 75243 Federal Communications Commission 7435 Oakland Mills Road Columbia MD 21046 Date: May 14, 2026 Subject: Certifications concerning “covered” equipment pursuant to Part 2.911(d)(5)(i) and (ii) FCC ID: 2AXJSIWRL6432BAFCLI To whom it may concern, Texas Instruments Incorporated (“the applicant”) certifies that the equipment for which authorization is sought is not the equipment on the Covered List, as established pursuant to § 1.50002 of CFR Title 47, that is prohibited from obtaining an equipment authorization under this subpart. This includes equipment that: (1) Has been certified as a modular transmitter; or (2) Meets the modular transmitter requirements of § 15.212 of this chapter and could be certified as a modular transmitter. pursuant to section 2.903 resulting the recent adoption of FCC 25-71 (et al., ET Docket No. 21-232, Second Report and Order); or (3) Uncrewed aircraft systems (UAS) and UAS critical components produced in a foreign country and all communications and video surveillance equipment and services listed in Section 1709(a)(1) of the FY25 National Defense Authorization Act (Pub. L. 118-159) Applicant certifies that, as of the date of the filing of the application, the applicant [is not] identified on the Covered List (as a specifically named entity or any of its subsidiaries or affiliates) as an entity producing “covered” equipment. Applicant further certifies that no Cybersecurity or anti-virus software produced or provided by Kaspersky Lab, Inc. or any of its successors and assignees, including equipment with integrated Kaspersky Lab, Inc. (or any of its successors and assignees) cybersecurity or anti-virus software is installed in the equipment being certified. The above-referenced Covered List is published by the Public Safety and Homeland Security Bureau (PSHSB), pursuant to Section 1.50002 of the Commission’s rules. Sincerely, ________________________ Yariv Raveh [email protected] Docusign Envelope ID: 420AB8D5-CA90-850D-810B-C468478821C9

Cover Letter(s)

TI Information – Selective Disclosure Texas Instruments, Incorporated 12500 TI Boulevard Dallas, TX 75243 FCC Laboratory 7435 Oakland Mills Rd Columbia MD 21046 Subject: Request for Confidentiality FCC ID: 2AXJSIWRL6432BAFCLI To Whom It May Concern, Pursuant to the provisions of Sections 0.457 and 0.459 of Commission’s rules (47CFR§§0.457, 0.459), we are requesting the Commission to withhold the following documents from public disclosure indefinitely. ⚫ Schematic Diagram ⚫ Block Diagram ⚫ Part List ⚫ Operational Description Above mentioned documents which contain detailed system and equipment description are considered as proprietary information in operation of the equipment. The public disclosure of above documents might be harmful to our company and would give competitor an unfair advantage in the market. In additional to above mentioned documents, pursuant to Public Notice DA 04-1705 of the Commission’ s policy, in order to comply with the marketing regulations in 47 CFR §2.803 and the importation rules in 47 CFR §2.1204, while ensuring that business sensitive information remains confidential until the actual marketing of newly authorized devices, we are requesting the Commission to withhold the following documents for 180 days after the grant of equipment authorization is issued: ⚫ External Photos ⚫ Internal Photos ⚫ Test Setup Photos ⚫ User Manual It is our understanding that all measurement test reports, FCC ID label format cannot be granted as confidential documents and those information will be available for public review once the grant of equipment authorization is issued. Best Regards, _______________________ Yariv Raveh [email protected] Docusign Envelope ID: 420AB8D5-CA90-850D-810B-C468478821C9

Cover Letter(s)

TI Information – Selective Disclosure Texas Instruments, Incorporated 12500 TI Boulevard Dallas, TX 75243 Tel: 214-567-2462 Fax: 214-479-5605 Date: May 14, 2026 Request for Modular Approval for FCC ID: 2AXJSIWRL6432BAFCLI Item Requirements Requirement Met EUT 1. The radio elements must have the radio frequency circuitry shielded. Physical components and tuning capacitor(s) may be located external to the shield, but must be on the module assembly Yes The module is equipped with its own shielding case. 2. The module must have buffered modulation/data inputs to ensure that the device will comply with Part 15 requirements with any type of input signal Yes The module has buffer modulation / data inputs. 3. The module must contain power supply regulation on the module Yes The module has its own power supply regulation. 4. The module must contain a permanently attached antenna, or contain a unique antenna connector, and be marketed and operated only with specific antenna(s), per §§ 15.203, 15.204(b), 15.204(c), 15.212(a), 2.929(b) Yes The module has a permanently attached antenna, with the antenna gain 6 dBi 5. The module must demonstrate compliance in a stand-alone configuration Yes The module was tested on evaluation board, and it’s not inside of another device during testing 6. The module must be labeled with its permanently affixed FCC ID label, or use an electronic display Yes The module transmitter will be labeled with its own FCC ID, and for OEM integration the integration manual contains labeling instructions for the host device per Part 15.212 (vi) 7. The module must comply with all specific rules applicable to the transmitter, including all the conditions provided in the integration instructions by the grantee Yes The module approved transmitter complies with all applicable rules and the integration manual contains any specific requirements addressed to the integrator and/or to the end-user of the final end-product. Docusign Envelope ID: 420AB8D5-CA90-850D-810B-C468478821C9 TI Information – Selective Disclosure 8. The module must comply with RF exposure requirements Yes The modular transmitter complies with RF exposure requirement. ______________________ Yariv Raveh [email protected] Docusign Envelope ID: 420AB8D5-CA90-850D-810B-C468478821C9

Cover Letter(s)

TI Information – Selective Disclosure Texas Instruments, Incorporated 12500 TI Boulevard Dallas, TX 75243 FCC Agent Authorization Date: May 14, 2026 To whom it may concern, Texas Instruments Incorporated hereby authorize Sporton International Inc. to act on our behalf in all matters relating to applications for FCC equipment authorization, including the signing of all documents relating to these matters. Any and all acts carried out by Sporton International Inc. on our behalf shall have the same effect as acts of our own. We also hereby certify that neither the applicant nor any party to the application is subject to a denial of Federal benefits that includes FCC benefits pursuant to section 5301 of the Anti-Drug Abuse Act of 1988. 21 U.S.C. 862. This authorization is limited to the following products: FCC ID: 2AXJSIWRL6432BAFCLI This authorization is valid until further written notice from Texas Instruments Incorporated. Sincerely, ________________________ Yariv Raveh [email protected] Docusign Envelope ID: 420AB8D5-CA90-850D-810B-C468478821C9

ID Label/Location Info

Label Location The label location is the top surface of the shield. Label Sample Label Location

RF Exposure Info

TEL : 886-3-327-3456 Page : 1 of 5 FAX : 886-3-328-4978 Issued Date : Jun. 04, 2026 Form version: 220617 RF EXPOSURE EVALUATION REPORT Report No. : FA612101 RF EXPOSURE EVALUATION REPORT FCC ID : 2AXJSIWRL6432BAFCLI Equipment : Certified 60GHz mmWave Radar Module For Motion and Presence Detection Brand Name : Texas Instruments Model Name : IWRL6432BAFCLIMBBR Applicant : Texas Instruments, Inc. 12500 TI BLVD; DALLAS, TX 75243 Manufacturer : Cloud Network Technology Singapore Pte.Ltd. Quang Chau Industrial Zone, Van Trung Ward, Viet Yen Town, Bac Giang Province, Vietnam Standard : 47 CFR Part2.1091 We, SPORTON INTERNATIONAL INC has been evaluated this product in accordance with 47 CFR Part2.1091 and it complies with applicable limit. Sporton Lab is accredited to ISO 17025 by Taiwan Accreditation Foundation (TAF code: 3786) and the FCC designation No. TW3786 under the FCC 2.948(e) by Mutual Recognition Agreement (MRA) in FCC evaluation. The results in this report apply exclusively to the tested model / sample. Without written approval of SPORTON INTERNATIONAL INC. Laboratory, the test report shall not be reproduced except in full SPORTON INTERNATIONAL INC. Wensan Laboratory No.58, Aly. 75, Ln. 564, Wenhua 3rd, Rd., Guishan Dist., Taoyuan City 333010, Taiwan Approved by: Cona Huang / Deputy Manager TEL : 886-3-327-3456 Page : 2 of 5 FAX : 886-3-328-4978 Issued Date : Jun. 04, 2026 Form version: 220617 RF EXPOSURE EVALUATION REPORT Report No. : FA612101 Table of Contents 1. DESCRIPTION OF EQUIPMENT UNDER TEST (EUT) ............................................................................. 4 2. MAXIMUM RF EIRP POWER AMONG PRODUCTION UNITS .................................................................. 4 3. RF EXPOSURE LIMIT INTRODUCTION .................................................................................................... 5 4. RADIO FREQUENCY RADIATION EXPOSURE EVALUATION ............................................................... 5 4.1. Standalone Power Density Calculation ............................................................................................. 5 TEL : 886-3-327-3456 Page : 3 of 5 FAX : 886-3-328-4978 Issued Date : Jun. 04, 2026 Form version: 220617 RF EXPOSURE EVALUATION REPORT Report No. : FA612101 History of this test report Report No. Version Description Issued Date FA612101 Rev. 01 Initial issue of report Jun. 04, 2026 TEL : 886-3-327-3456 Page : 4 of 5 FAX : 886-3-328-4978 Issued Date : Jun. 04, 2026 Form version: 220617 RF EXPOSURE EVALUATION REPORT Report No. : FA612101 1. Description of Equipment Under Test (EUT) Product Feature & Specification EUT Type Certified 60GHz mmWave Radar Module For Motion and Presence Detection Brand Name Texas Instruments Model Name IWRL6432BAFCLIMBBR FCC ID 2AXJSIWRL6432BAFCLI Wireless Technology and Frequency Range 60GHz Radar: 57000MHz ~ 59400MHz Mode FMCW EUT Stage Production Unit Reviewed by: Jason Wang Report Producer: Daisy Peng 2. Maximum RF EIRP power among production units Mode Maximum EIRP power(dBm) 60GHz 19 TEL : 886-3-327-3456 Page : 5 of 5 FAX : 886-3-328-4978 Issued Date : Jun. 04, 2026 Form version: 220617 RF EXPOSURE EVALUATION REPORT Report No. : FA612101 3. RF Exposure Limit Introduction According to ANSI/IEEE C95.1-1992, the criteria listed in Table 1 shall be used to evaluate the environmental impact of human exposure to radio frequency (RF) radiation as specified in §1.1310. The MPE was calculated at 20 cm to show compliance with the power density limit. The following formula was used to calculate the Power Density: 퐒= 퐏퐆 ퟒ훑퐑 ퟐ Where: S = Power Density P = Output Power at Antenna Terminals G = Gain of Transmit Antenna (linear gain) R = Distance from Transmitting Antenna 4. Radio Frequency Radiation Exposure Evaluation 4.1. Standalone Power Density Calculation Band Maximum EIRP (dBm) Maximum PG (mW) Power Density at 20cm (mW/cm^2) Limit (mW/cm^2) 60GHz 19.00 79.43 0.016 1.000 Conclusion: According to 47 CFR §1.1307, the RF exposure analysis concludes that the RF Exposure is FCC compliant.

Test Report

TEL: 886-3-327-0868 Page Number : 1 of 31 FAX: 886-3-327-0855 Issue Date : Jul. 08, 2026 Report Template No.: BU5-FR15.255 Version 1.0 Report Version : 03 FCC RADIO TEST REPORT Report No.: FR612101 FCC RADIO TEST REPORT FCC ID : 2AXJSIWRL6432BAFCLI Equipment : Certified 60GHz mmWave Radar Module For Motion and Presence Detection Brand Name : Texas Instruments Model Name : IWRL6432BAFCLIMBBR Marketing Name : IWRL6432WMOD Applicant : Texas Instruments, Inc. 12500 TI BLVD; DALLAS, TX 75243 Manufacturer : Cloud Network Technology Singapore Pte.Ltd. Quang Chau Industrial Zone, Van Trung Ward, Viet Yen Town, Bac Giang Province, Vietnam Standard : FCC 47 CFR Part 15.255 The product was received on Feb. 24, 2026 and testing was performed from Apr. 14, 2026 to Apr. 20, 2026. We, Sporton International Inc. Wensan Laboratory, would like to declare that the tested sample has been evaluated in accordance with the test procedures and has been in compliance with the applicable technical standards. The test results in this report apply exclusively to the tested model / sample. Without written approval from Sporton International Inc. Wensan Laboratory, the test report shall not be reproduced except in full. Approved by: Louis Wu Sporton International Inc. Wensan Laboratory No.58, Aly. 75, Ln. 564, Wenhua 3rd, Rd., Guishan Dist., Taoyuan City 333010, Taiwan (R.O.C.) TEL: 886-3-327-0868 Page Number : 2 of 31 FAX: 886-3-327-0855 Issue Date : Jul. 08, 2026 Report Template No.: BU5-FR15.255 Version 1.0 Report Version : 03 FCC RADIO TEST REPORT Report No.: FR612101 Table of Contents History of this test report ................................................................................................................................. 3 Summary of Test Result................................................................................................................................... 4 1 General Description ................................................................................................................................... 5 1.1 Feature of Equipment Under Test ..................................................................................................... 5 1.2 Modification of EUT ........................................................................................................................... 5 1.3 Testing Location ................................................................................................................................ 5 1.4 Applied Standards ............................................................................................................................. 5 2 Test Configuration of Equipment Under Test ......................................................................................... 6 2.1 Test Mode.......................................................................................................................................... 6 2.2 Connection Diagram of Test System ................................................................................................ 6 2.3 Far Field Condition for Frequency above 18GHz.............................................................................. 7 3 Radiated Test Items ................................................................................................................................... 8 3.1 Measuring Instruments ...................................................................................................................... 8 3.2 Test Setup ......................................................................................................................................... 8 3.3 Test Result of Radiated Test ............................................................................................................. 9 3.4 Emission Bandwidth ........................................................................................................................ 10 3.5 EIRP Power Measurement .............................................................................................................. 13 3.6 Transmit Spurious Emission ............................................................................................................ 15 3.7 Frequency Stability .......................................................................................................................... 25 4 AC conducted Emission Measurement ................................................................................................. 26 4.1 Limit of AC Conducted Emission ..................................................................................................... 26 4.2 Measuring Instruments .................................................................................................................... 26 4.3 Test Procedures .............................................................................................................................. 26 4.4 Test Setup ....................................................................................................................................... 27 4.5 Test Result of AC Conducted Emission .......................................................................................... 27 5 List of Measuring Equipment .................................................................................................................. 28 6 Measurement Uncertainty ....................................................................................................................... 31 Appendix A. AC Conducted Emission Test Result Appendix B. Setup Photographs TEL: 886-3-327-0868 Page Number : 3 of 31 FAX: 886-3-327-0855 Issue Date : Jul. 08, 2026 Report Template No.: BU5-FR15.255 Version 1.0 Report Version : 03 FCC RADIO TEST REPORT Report No.: FR612101 History of this test report Report No. Version Description Issue Date FR612101 01 Initial issue of report Jun. 04, 2026 FR612101 02 Revise section 1.1 This report is an updat…

Text truncated - open the document above for the full version.

Contact Information

Applicant

Yariv Raveh(Product Line Manager)
[email protected]Fax: 2144795605

Technical Contact

Texas Instruments IncorporatedYariv Raveh
[email protected]

12500 TI Boulevard · Dallas, 75243 · United States

Test Firm

SPORTON International Inc.Alex Chen
[email protected]Fax: +886-3-327-0973

Technical Specifications

#Rule PartsFrequency RangePower Output
115.25557.00 GHz - 59.40 GHz78.50 mW
Modular Type
Single Modular Approval
Confidentiality
Long Term
Grant Notes
Power output listed is peak EIRP. Approved for OEM integration only. The module antenna(s) must be installed to meet the RF exposure compliance separation distance of 20 cm. Co-location of this module with other transmitters that operate simultaneously are required to be evaluated using the FCC multi-transmitter procedures. The host integrator must follow the integration instructions provided by the module manufacturer and ensure that the composite-system end product complies with the FCC requirements by a technical assessment or evaluation to the FCC rules and to KDB Publication 996369. The host integrator must be instructed to ensure that the end user has no manual instructions to remove or install the module. The module grantee is responsible for providing the documentation to the system integrator on restrictions of use, for continuing compliance of the module. Operation on satellites and aircrafts while airborne is prohibited.