Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.
User Guide Wireless Charging PowerBank PB-D100W2 Thanks for purchasing Vogtech product, please read this user guide carefully before operation and keep it for future reference. EN 1. Box Contents: 1 Powerbank 1 USB to Micro USB Cable 1 User Guide 2. Technical Specifications: Battery Type: Capacity: Material: Size: Weight: Lithium Polymer 37.0 Wh(3.7V/10.000 mAh) Plastic 145.0x70.5.0x17.5 mm 236.0 g Output: Input: 3. About the Powerbank: USB 4.5V/5A, 5V/3A, 9V/2A, 12V/1.5A Type C 5V/3A, 9V/2A, 12V/1.5A 5W Type C 5V/3A, 9V/2A Micro USB 5V/2A, 9V/2A (1) USB Output (QC 18W+Huawei 22.5W) (2) Type Input&Output (PD 18W) (3) Micro USB Input (QC 18W) (4) Wireless Charging LED (5) Power On/Off (6) Wireless Charging 5W (7) Lighting Logo (8) Capacity LEDs (9) Quick Charging LED User Guide Vogtech Powerbank Wireless 10.000 mAh 123 5 6 9 8 7 4 ENEN 6-2. Charge with a free USB port on your PC. 5. Charge Your Devices: The powerbank is compatible with all smartphones, tablets and all USB-Powered device with 5V, 9V, 12V input. To charge your device with powerbank, plug the USB charging cable into the USB output or Type C output, and connect the other end to device. * The supplied charging cable supports all smart devices that has a Type C input. For the smart devices that have a different input, please use the cable supplied by its manufacturer. * The Capacity LED on display will light up and one of LEDs will be blinking during charging. * The Powerbank would automatically shut off in a few seconds after finishing charging. 4. Check Your Powerbank Battery Status from the LED: Press the Power On/Off Button to check the remaining capacity. 6. Charge the Powerbank: We suggest that your fully charging the powerbank before each use. To Charge your powerbank, use one of the following 2 charging options: 6-1. Charge with a Power Adapter with USB port. Connect the powerbank to power apdater USB port with the supplied USB to Type C Cable directly. or with your own USB to Micro USB cable. The battery is low, less than 25% remaining . PLEASE recharge. The battery is medium, appx 50% remaining . Please recharge after several use. The battery is healthy, appx 75%remaining. You can take it when you are on-the-go! The battery is sufficient, more than 75% remaining. You can take it when you are on-the-go! 5-1. Charge with a USB Cable. Step 1. Press the power button on the left side until you see the wireless charging LED light up in RED. Step 2. Place down your Qi-Enabled smart phone on the powerbank surface where you can see a wirless charging icon. * The LED light will be blue during charging. * The LED Light will be red after charging. 5-2. Charge Qi-Enabled Smart phone wirelessly. >>> Step 1. Press the power button once, and then press it and hold it for 3 seconds again to activate the small power charging mode. Step 2. Place down your Qi-Enabled gadgets on the powerbank surface where you can see a wirless charging icon. * The LED light will be blue during charging. * The LED Light will be red after charging. 5-3. Charge Qi-Enabled Gadgets(TWS, Mouse etc) with Small Wireless Power >>> Connect the powerbank to a freeUSB port on your PC with the supplied USB to Type C Cable directly. or with your own USB to Micro USB cable. IMPORTANT DISPOSAL: This electrical appliance does not belong in the household waste. For proper disposal, please contact the public collection in your community. EN This device complies with part 15 of the FCC Rules, Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received,including interference that may cause undersired operation. Any changes or modifications not expressly approved by the party responsible for compliance could void the user's authority to operate the equipment. NOTE: This eqiupment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide resonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures: -- Reorient or relocate the receiving antenna. -- Increase the equipment into an outlet on a circuit different from that to which the receiver is connected. -- Consult the dealer or an experienced radio/TV technician for help. FCC Radiation Exposure Statement This equipment complies with FCC radiation exposure limits set forth for an uncontrolled environment. This equipment should be installed and operated with a minimum distance of 20 cm between the radiator and your body Warning: Changes or modifications to this unit not expressly approved by the part responsible for compliance could void the user's authority to operate the equipment. ID: 2AXMQ-PB-D100W2
C5266091_X8_Ed.1 1/1 Letter of Authorization Shenzhen iSonteck Co., Ltd. Company: Shenzhen iSonteck Co., Ltd. Address: F/5, Zhongkong Bldg, Hengfeng Industrial Park, Zhoushi Rd, Xixiang, Bao’an District, Shenzhen China Product Name: Wireless Charging Power Bank Model Number: PB-D100W2 FCC Identifier: 2AXMQ-PBD100W2 We authorize LGAI Technological Center S.A., Ronda de la Font del Carme, s/n, 08193 Bellaterra, Spain, to act on our behalf on all matters concerning the above named equipment. Any individual within LGAI Technological Center S.A. is authorized to act on our behalf and take action on the application. We declare that authorize LGAI Technological Center S.A., Ronda de la Font del Carme, s/n, 08193 Bellaterra, Spain, is allowed to forward all information related to the approval project to the Federal Communication Commission and to discuss any issues concerning the approval application. Any and all acts carried out by LGAI Technological Center S.A. on our behalf shall have the same effect as acts of our own. Name: Sciven W Zao Date: 9/23/2020 Title: General Manager Signature of applicant:
C5266091_X10_Ed.1 1/1 Shenzhen iSonteck Co., Ltd. Office of Engineering Technology Federal Communications Commission 7435 Oakland Mills Road Columbia, MD 21046 Date: 9/23/2020 Subject: Request for Confidentiality FCC ID: 2AXMQ-PBD100W2 To Whom It May Concern, Pursuant to the provisions of Sections 0.457 and 0.459 of Commission's rules (47CFR0.457, 0.459), we are requesting the Commission to withhold the following attachment(s) as confidential document from public disclosure. Exhibits Long-Term Confidentiality Short-Term Confidentiality ID Label/Location No No Attestation Statement No No External Photos No Block Diagram Schematics Test Report No No Test Setup Photos No User’s Manual Internal Photos Parts List / Tune Up RF Exposure Info Operational Description Cover Letter(s) No No SDR Software / Security Info No Above mentioned document contains detailed system and equipment description are considered as proprietary information in operation of the equipment. The public disclosure of above documents might be harmful to our company and would give competitor an unfair advantage in the market. It is our understanding that all measurement test reports, FCC ID label format and correspondent during certification review process cannot be granted as confidential documents and those information will be available for public review once the grant of equipment authorization is issued. Sincerely, Signature: Name: Sciven W Zao Date: 9/23/2020 Title: General Manager
1 - Page 1 of 3 - Report No.: MTi20070209-4E1-1 Tel:(86-755)88850135 Fax: (86-755) 88850136 Web: http://www.mtitest.com E-mail: [email protected] Address: 101, No. 7, Zone 2, Xinxing Industrial Park, Fuhai Avenue, Xinhe Community, Fuhai Street, Bao’ an District, Shenzhen, Guangdong, China. APPENDIX 1: EUT PHOTO Photo 1 (For model PB-D100W2) Photo 2 1 - Page 2 of 3 - Report No.: MTi20070209-4E1-1 Tel:(86-755)88850135 Fax: (86-755) 88850136 Web: http://www.mtitest.com E-mail: [email protected] Address: 101, No. 7, Zone 2, Xinxing Industrial Park, Fuhai Avenue, Xinhe Community, Fuhai Street, Bao’ an District, Shenzhen, Guangdong, China. Photo 3 Photo 4 1 - Page 3 of 3 - Report No.: MTi20070209-4E1-1 Tel:(86-755)88850135 Fax: (86-755) 88850136 Web: http://www.mtitest.com E-mail: [email protected] Address: 101, No. 7, Zone 2, Xinxing Industrial Park, Fuhai Avenue, Xinhe Community, Fuhai Street, Bao’ an District, Shenzhen, Guangdong, China. Photo 5 Photo 6 ----END OF REPORT----
40mm*15mm
1 - Page 1 of 3 - Report No.: MTi20070209-4E1-1 Tel:(86-755)88850135 Fax: (86-755) 88850136 Web: http://www.mtitest.com E-mail: [email protected] Address: 101, No. 7, Zone 2, Xinxing Industrial Park, Fuhai Avenue, Xinhe Community, Fuhai Street, Bao’ an District, Shenzhen, Guangdong, China. APPENDIX 1: EUT PHOTO Photo 1 (For model PB-D100W2) Photo 2 Coil antenna 1 - Page 2 of 3 - Report No.: MTi20070209-4E1-1 Tel:(86-755)88850135 Fax: (86-755) 88850136 Web: http://www.mtitest.com E-mail: [email protected] Address: 101, No. 7, Zone 2, Xinxing Industrial Park, Fuhai Avenue, Xinhe Community, Fuhai Street, Bao’ an District, Shenzhen, Guangdong, China. Photo 3 Photo 4 1 - Page 3 of 3 - Report No.: MTi20070209-4E1-1 Tel:(86-755)88850135 Fax: (86-755) 88850136 Web: http://www.mtitest.com E-mail: [email protected] Address: 101, No. 7, Zone 2, Xinxing Industrial Park, Fuhai Avenue, Xinhe Community, Fuhai Street, Bao’ an District, Shenzhen, Guangdong, China. Photo 5 Photo 6 ----END OF REPORT----
This test report is valid for the tested samples only. It cannot be reproduced except in full without prior written consent of Shenzhen Microtest Co., Ltd. Tel:(86-755)88850135 Fax: (86-755) 88850136 Web: http://www.mtitest.com E-mail: [email protected] Address: 101, No. 7, Zone 2, Xinxing Industrial Park, Fuhai Avenue, Xinhe Community, Fuhai Street, Bao’ an District, Shenzhen, Guangdong, China. EXPOSURE REPORT FCC ID: 2AXMQ-PBD100W2 Date of issue: Sept. 17, 2020 Report Number: MTi20070209-4E2 Sample Description: Wireless Charging Power Bank Mo d e l( s ) : PB-D100W2 Applicant: Shenzhen iSonteck Co., Ltd Address: F/5, Zhongkong Bldg, Hengfeng Industrial Park, Zhoushi Rd, Xixiang, Bao’an District, Shenzhen China Date of Test: July 10, 2020 - Sept. 17, 2020 Shenzhen Microtest Co., Ltd. http://www.mtitest.com - Page 2 of 9 - Report No.: MTi20070209-4E2 Tel:(86-755)88850135 Fax: (86-755) 88850136 Web: http://www.mtitest.com E-mail: [email protected] Address: 101, No. 7, Zone 2, Xinxing Industrial Park, Fuhai Avenue, Xinhe Community, Fuhai Street, Bao’ an District, Shenzhen, Guangdong, China. Test Result Certification Applicant’s name: Shenzhen iSonteck Co., Ltd Address: F/5, Zhongkong Bldg, Hengfeng Industrial Park, Zhoushi Rd, Xixiang, Bao’an District, Shenzhen China Manufacture's name: Shenzhen iSonteck Co., Ltd Address: F/5, Zhongkong Bldg, Hengfeng Industrial Park, Zhoushi Rd, Xixiang, Bao’an District, Shenzhen China Product name: Wireless Charging Power Bank Trademark: Vogtech or OEM Model name: PB-D100W2 Standard: FCC CFR 47 PART 1 , 1.1310 RF Exposure Procedures: KDB 680106 D01 RF Exposure Wireless Charging App v03 This device described above has been tested by Shenzhen Microtest Co., Ltd. and the test results show that the equipment under test (EUT) compliance with the FCC requirements. And it is applicable only to the tested sample identified in the report. Tested by: Demi Mu Sept. 17, 2020 Reviewed by: Leo Su Sept. 17, 2020 Approved by: Tom Xue Sept. 17, 2020 - Page 3 of 9 - Report No.: MTi20070209-4E2 Tel:(86-755)88850135 Fax: (86-755) 88850136 Web: http://www.mtitest.com E-mail: [email protected] Address: 101, No. 7, Zone 2, Xinxing Industrial Park, Fuhai Avenue, Xinhe Community, Fuhai Street, Bao’ an District, Shenzhen, Guangdong, China. 1 General Information 1.1 Description of EUT Product name: Wireless Charging Power Bank Brand name: Vogtech or OEM Model name: PB-D100W2 Series model: N/A Deference in serial model: N/A Operation frequency: 115–205 kHz Operational mode: Wireless charging Modulation type: ASK Antenna type: Coil Antenna Power source: DC 9V from adapter AC 120V/60Hz or DC 3.7V from battery Battery: DC 3.7V 10000mAh Adapter information: N/A 1.2 Ancillary equipment list Equipment Model S/N Manufacturer / / / / / / / / 1.3 Measurement uncertainty Measurement Uncertainty for a Level of Confidence of 95 %, U=2xUc(y) Radiated emission(150kHz~30MHz) ± 2.5 dB Radiated emission(30MHz~1GHz) ± 4.2 dB Radiated emission (above 1GHz) ± 4.3 dB Temperature ±1 degree Humidity ± 5 % - Page 4 of 9 - Report No.: MTi20070209-4E2 Tel:(86-755)88850135 Fax: (86-755) 88850136 Web: http://www.mtitest.com E-mail: [email protected] Address: 101, No. 7, Zone 2, Xinxing Industrial Park, Fuhai Avenue, Xinhe Community, Fuhai Street, Bao’ an District, Shenzhen, Guangdong, China. 2 Testing site Test Site Shenzhen Microtest Co., Ltd Test Site Location 101, No. 7, Zone 2, Xinxing Industrial Park, Fuhai Avenue, Xinhe Community, Fuhai Street, Bao’ an District, Shenzhen, Guangdong, China. FCC Registration No.: 448573 - Page 5 of 9 - Report No.: MTi20070209-4E2 Tel:(86-755)88850135 Fax: (86-755) 88850136 Web: http://www.mtitest.com E-mail: [email protected] Address: 101, No. 7, Zone 2, Xinxing Industrial Park, Fuhai Avenue, Xinhe Community, Fuhai Street, Bao’ an District, Shenzhen, Guangdong, China. 3 List of test equipment Equipment No. Equipment Name Manufacturer Model Serial No. Calibration date Due date MTI-E060 Broadband Field Meter Narda Safety Test Solutions GmbH NBM- 520 D-1699 2020/06/22 2021/06/21 MTI-E061 Probe E-Field Narda Safety Test Solutions EF0691 H-0571 2020/06/22 2021/06/21 - Page 6 of 9 - Report No.: MTi20070209-4E2 Tel:(86-755)88850135 Fax: (86-755) 88850136 Web: http://www.mtitest.com E-mail: [email protected] Address: 101, No. 7, Zone 2, Xinxing Industrial Park, Fuhai Avenue, Xinhe Community, Fuhai Street, Bao’ an District, Shenzhen, Guangdong, China. 4 Test Results 4.4 Maximum permissible exposure 4.4.1 Limit Frequency range(MHz) Electric field strength(V/m) Magnetic field strength(A/m) Power density(mW/cm2) Averaging time(minutes) (A) Limits for Occupational/Controlled Exposure 0.3-3.0 614 1.63 *100 6 3.0-30 1842/f 4.89/f *900/f 2 6 30-300 61.4 0.163 1.0 6 6 300-1500 f/300 6 1500-100000 5 6 (B) Limits for General Population/Uncontrolled Exposure 0.3-1.34 614 1.63 *100 30 1.34-30 824/f 2.19/f *180/f 2 30 30-300 27.5 0.073 0.2 30 300-1500 f/1500 30 1500-100000 1 30 f = frequency in MHz * = Plane-wave equivalent power density 4.4.2 Test Procedures E and H-field measurements should be made with the center of the probe at a distance of 15 cm surrounding the device and 20 cm above the top surface of the primary/client pair. These measurements should be repeated for three different client battery levels, 1%, 50%, and 99%. Record the test results. KDB 680106 D01 RF Exposure Wireless Charging App v03: (1) Power transfer frequency is less than 1MHz. (2) Output power from each primary coil is less than or equal to 15 watts. (3) The transfer system includes only single primary and secondary coils. This includes charging systems that may have multiple primary coils and clients that are able to detect and allow coupling only between individual pairs of coils. (4) Client device is placed directly in contact with the transmitter. (5) Mobile exposure conditions only (portable exposure conditions are not covered by this exclusion). (6) The aggregate H-field strengths at 15 cm surrounding the device and 20 cm above the to…
Text truncated - open the document above for the full version.
This test report is valid for the tested samples only. It cannot be reproduced except in full without prior written consent of Shenzhen Microtest Co., Ltd. Tel:(86-755)88850135 Fax: (86-755) 88850136 Web: http://www.mtitest.com E-mail: [email protected] Address: 101, No. 7, Zone 2, Xinxing Industrial Park, Fuhai Avenue, Xinhe Community, Fuhai Street, Bao’ an District, Shenzhen, Guangdong, China. Test Report FCC ID: 2AXMQ-PBD100W2 Date of issue: Sept. 17, 2020 Report number: MTi20070209-4E1 Sample description: Wireless Charging Power Bank Mo d e l( s ) : PB-D100W2 Applicant: Shenzhen iSonteck Co., Ltd Address: F/5, Zhongkong Bldg, Hengfeng Industrial Park, Zhoushi Rd, Xixiang, Bao’an District, Shenzhen China Date of test: July 10, 2020 - Sept. 17, 2020 Shenzhen Microtest Co., Ltd. http://www.mtitest.com - Page 2 of 24 - Report No.: MTi20070209-4E1 Tel:(86-755)88850135 Fax: (86-755) 88850136 Web: http://www.mtitest.com E-mail: [email protected] Address: 101, No. 7, Zone 2, Xinxing Industrial Park, Fuhai Avenue, Xinhe Community, Fuhai Street, Bao’ an District, Shenzhen, Guangdong, China. Table of Contents 1 GENERAL INFORMATION ................................................................................................................................... 4 1.1 FEATURE OF EQUIPMENT UNDER TEST (EUT) ................................................................................................................... 4 1.2 TEST MODE .............................................................................................................................................................. 4 1.3 EUT TEST SETUP........................................................................................................................................................ 5 1.4 ANCILLARY EQUIPMENT .............................................................................................................................................. 5 2 SUMMARY OF TEST RESULT ............................................................................................................................... 6 2.1 OPERATION CHANNEL LIST ........................................................................................................................................... 6 2.2 TEST CHANNEL .......................................................................................................................................................... 6 3 TEST FACILITIES AND ACCREDITATIONS .............................................................................................................. 7 3.1 TEST LABORATORY ..................................................................................................................................................... 7 3.2 ENVIRONMENTAL CONDITIONS ..................................................................................................................................... 7 3.3 MEASUREMENT UNCERTAINTY ...................................................................................................................................... 7 3.4 TEST SOFTWARE ........................................................................................................................................................ 7 4 LIST OF TEST EQUIPMENT .................................................................................................................................. 8 5 TEST RESULTS ..................................................................................................................................................... 9 5.1 ANTENNA REQUIREMENT ............................................................................................................................................ 9 5.1.1 Standard requirement ................................................................................................................................. 9 5.1.2 EUT Antenna ............................................................................................................................................... 9 5.2 CONDUCTED EMISSION ............................................................................................................................................. 10 5.2.1 Limits ......................................................................................................................................................... 10 5.2.2 Test Procedures ......................................................................................................................................... 10 5.2.3 Test Setup .................................................................................................................................................. 10 5.2.4 Test Result ................................................................................................................................................. 10 5.3 RADIATED EMISSION ................................................................................................................................................. 15 5.3.1 Limits ......................................................................................................................................................... 15 5.3.2 Test Procedures ......................................................................................................................................... 16 5.3.3 Test Setup .................................................................................................................................................. 17 5.3.4 Test Result ................................................................................................................................................. 17 5.4 OCCUPIED BANDWIDTH............................................................................................................................................. 21 5.4.1 Test method ...........................................................…
Text truncated - open the document above for the full version.
Model: PB-D100W2 Radiated emission Conducted emission
| # | Rule Parts | Frequency Range | Power Output |
|---|---|---|---|
| 1 | 15C | 0.115 MHz - 0.205 MHz | - |

Portable Solarpanel
Equipment Class
DCD - Part 15 Low Power Transmitter Below 1705 kHz