FCCID.CO- FCC ID Database
HomeCompaniesEquipment ClassesSearch

© 2026 FCC ID Database. All rights reserved.

AboutContactData sourced from FCC public records
  1. Home/
  2. Zhongshan Dottsun Electronic Co., Ltd/
  3. 2AXPN90-1680-8K

2AXPN90-1680-8KWork Light

Zhongshan Dottsun Electronic Co., Ltd
Work Light - FCC ID 2AXPN90-1680-8K - Zhongshan Dottsun Electronic Co., Ltd
Click to zoom

Application Details

Equipment Class
DSS - Part 15 Spread Spectrum Transmitter
Date of Grant
Aug 11, 2026
Application Purpose
Original Equipment
Equipment Note
Work Light
Frequency Range
2402.00000000 - 2480.00000000
Company
Zhongshan Dottsun Electronic Co., Ltd
Country
China

Documents & Files

Select a file to view

Users Manual

↗

Attestation Statements

↗
↗
↗

Cover Letter(s)

↗
↗

External Photos

↗

ID Label/Location Info

↗

Internal Photos

↗

RF Exposure Info

↗

Test Report

↗
↗
↗

Test Setup Photos

↗

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

Users Manual

1 • Please read and understand this entire manual before attempting to operate the product./ Lea y comprenda completamente este manual antes de intentar operar el producto. SAFETY INFORMATION/INFORMACIÓN DE SEGURIDAD This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures: • Reorient or relocate the receiving antenna. • Increase the separation between the equipment and receiver. • Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. • Consult the dealer or an experienced radio/TV technician for help. Caution: Any changes or modifications to this device not explicitly approved by manufacturer could void your authority to operate this equipment. This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. RF Exposure Information This equipment complies with FCC radiation exposure limits set forth for an uncontrolled environment. This equipment should be installed and operated with minimum distance 20cm between the radiator and your body. FCC STATEMENT •BE EXTREMELY CAREFUL WHEN USING THIS DEVICE. Improper use of this light can result in injury or death. Follow all safeguards stated inthis manual in addition to normal safety precautions in working with electrical devices. DO NOT attempt to service this device. When using indoor safety rules may result in FIRE, ELECTRICAL SHOCK or INJURY./ SEA EXTREMADAMENTE CUIDADOSO AL USAR ESTE DISPOSITIVO. El uso ina- propiado de esta luz de trabajo puede provocar lesiones graves o la muerte. Cumpla con todas las medidas de seguridad indicadas en este manual, además de las precauciones normales de seguridad para trabajar con dispositivos eléctricos. NO intente reparar este dispositivo. Cuandoutilice luces de trabajo portátiles interior, tome siempre las precauciones de seguridad básicas para reducir el riesgo de incendios, descargas eléctri- cas y lesiones personales. El incumplimiento de las siguientes reglas de seguridad podría resultar en INCENDIOS, DESCARGAS ELÉCTRICAS o LESIONES. • Use only 3-wire UL/ETL Listed damp location extension cords that have 3-prong grounded plugs and grounded receptacles that accept the light’s plug. /Use solo extensiones eléctricas para ubicaciones húmedas de tres conductores homologados por UL/ETL, que tengan enchufes con puesta a tierra de tresclavijas y tomacorrientes con puesta a tierra que acepten el enchufe de la luz de trabajo. • To avoid electrical shock, DO NOT use near water or in areas where water may accumulate. Keep light at least 16 ft. from pools or spas. Keep plugs dry. Use only Ground Fault Circuit Interrupter (GFCI) protected receptacles when using this light in damp locations./ Para evitar descargas eléctricas, NO lo use cerca del agua o en áreas donde se pueda acumular agua. Mantenga la luz de trabajo a 4.87 m como mínimo de piscinas o spas. Man-tenga los enchufes secos. Use solo tomacorrientes protegidos por un interruptor de circuito de falla de puesta a tierra (GFCI, por sus siglas en inglés) cuando utilice esta luz de trabajo en ubicaciones húmedas. IMPORTANT INFORMATION/INFORMACIÓN IMPORTANTE Thank you for purchasing this KOBALT product. We’ve created these easy-to-follow instructions to ensure you spend your time enjoying the product instead of putting it together. But, if you need more information than what is provided here, please visit Lowes.com, search the item number and refer to the Guides & Documents tab on the product’s page. Gracias por comprar este producto KOBALT. Hemos creado estas instrucciones fáciles de seguir para garantizar que pase su tiempo disfrutando el producto en lugar de armándolo. No obstante, si necesita más información que la entregada aquí, visite Lowes.com, busque el número de artículo y consulte la pestaña Guides & Documents (Guías y documentos) en la página del producto. DF26363 ITEM/ARTÍCULO #8352115 MODEL/MODELO #FSI 90-1680-8K FOLDING 3-HEAD LED WITH BLUETOOTH ® SPEAKER LUZ DE TRABAJO PLEGABLE DE 3 CABEZALES LED CON ALTAVOZ BLUETOOTH ® KOBALT and logo design are trademarks or registered trademarks of LF, LLC. All rights reserved. KOBALT y el diseño del logotipo son marcas comerciales o marcas registradas de LF, LLC. Todos los derechos reservados. Questions, problems or missing parts? Before returning, contact us on: 866-356-2258, 8 a.m. - 8 p.m., EST, Monday - Sunday. ¿Preguntas, problemas o piezas faltantes? Antes de volver a la tienda, póngase en contacto al: 866-356-2258, de lunes a domingo de 8 a.m. a 8 p.m., hora estándar del Este. WARRANTY/GARANTÍA This product is covered under a 3-year limited warranty. Manufacturer warrants to the original purchaser that this product is free from defects in materials and workmanship for the period of 3 years from the date of purchase. Proof of purchase including date and explanation of complaint is required for warranty ser- vice./Este producto está cubierto por una garantía limitada de 3 años. El fabricante garantiza al comprador original que este producto no presentará defectos ni en los materiales ni de fabricación durante 3 años a partir d…

Text truncated - open the document above for the full version.

Attestation Statements

Covered Equipment Attestation Letter For Certification Service in the USA Federal Communications Commission Equipment Authorization Division, Application Processing Branch 7435 Oakland Mills Road Columbia, MD 21048 To whom it may concern Pursuant to Section 2.911(d)(5)(i)-(ii) of the Commission’s Rules (47 C.F.R.) we attest as follows for the product listed below: FCC ID Model name 2AXPN90-1680-8K FSl 90-1680-8K, 25687 We, Applicant Company Name: Zhongshan Dottsun Electronic Co., Ltd Address: 2nd road of guanglong, jinlong industrial park Zhongshan City, Guangdong 528411, China Phone: +86-760-88558060 certify that the equipment for which authorization is sought is not “covered” equipment prohibited from receiving an equipment authorization pursuant to section 2.903 of the FCC rules. This includes the cybersecurity and anti-virus software produced or provided by Kaspersky Lab, Inc. or any of ist successors and assignees. We certify that, as of the date of the filing of the application, the applicant is not identified on the Covered List as an entity producing “covered” equipment. If you have any questions, please feel free to contact us at the address shown below. Sincerely, 2026-08-11 Signature Date Name / Title: July Meng / Sales Company: Zhongshan Dottsun Electronic Co., Ltd Address: 2nd road of guanglong, jinlong industrial park Zhongshan City, Guangdong 528411, China Phone: +86-760-88558060 Fax: +86-760-88558060 E-Mail: [email protected]

Attestation Statements

Due Diligence Letter For Certification Service in the USA Federal Communications Commission Equipment Authorization Division, Application Processing Branch 7435 Oakland Mills Road Columbia, MD 21048 To whom it may concern FCC ID Model name 2AXPN90-1680-8K FSl 90-1680-8K, 25687 Pursuant to KDB 986446 D01 Covered Equipment Guidance the evaluation of the product above shows compliance for the following reasons: Compliance Evaluation process Results Inherent compliance The chipset(s) used is not capable of running the cybersecurity and/or anti-virus software Compliance The memory used does not allow the running the cybersecurity and/or anti-virus software Compliance The storage capacity does not allow the running the cybersecurity and/or anti-virus software Compliance The operating system used is not capable of running the cybersecurity and/or anti-virus software Compliance No inherent compliance Based on software bill of material Based on scan for running software on the device Based on filesystem scan for cybersecurity and/or anti-virus software The equipment for which authorization is sought complies with the rules and fulfils the requirements as detailed in the above mentioned KDB. Evaluation performed by Company Name: Shenzhen LCS Compliance Testing Laboratory Ltd. Contact Name: Martion Lee Address: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Phone: +86-755-82591330 Email: [email protected] Signature: Date: 2026-07-24

Cover Letter(s)

Confidentiality Request Letter For Certification Service in the USA Federal Communication Commission Equipment Authorization Division, Application Processing Branch 7435 Oakland Mills Road Columbia, MD 21048 To whom it may concern Pursuant to Paragraphs §0.457 and 0.459 of the Commission’s Rules (47 C.F.R.) and Section §552(b)(4) of the Freedom of Information Act, we request confidentiality for the documentation of the following products: FCC ID Model name 2AXPN90-1680-8K FSl 90-1680-8K, 25687 For the products listed above, we request permanent confidentiality for all applicable exhibits as there are: • the Operational Description • the Block Diagram • the Schematics • the Part List • the Tune up Information The above listed exhibits contain trade secrets and proprietary information that could be of benefit to our competitors. If you have any questions, please feel free to contact us at the address shown below. Sincerely, 2026-08-11 Signature Date Name / Title: July Meng / Sales Company: Zhongshan Dottsun Electronic Co., Ltd Address: 2nd road of guanglong, jinlong industrial park Zhongshan City, Guangdong 528411, China Phone: +86-760-88558060 Fax: +86-760-88558060 E-Mail: [email protected]

Cover Letter(s)

Zhongshan Dottsun Electronic Co., Ltd 2nd road of guanglong, jinlong industrial park Zhongshan City, Guangdong 528411, China Date: August 11, 2026 FCC ID: 2AXPN90-1680-8K Model Number: FSl 90-1680-8K, 25687 To: Federal Communication Commission Authorization and Evaluation Division 7435 Oakland Mills Road Columbia, MD 21048 To Whom It May Concern, We, Zhongshan Dottsun Electronic Co., Ltd hereby declare that our product (Work Light) Model Number: FSl 90-1680-8K, 25687 board, Schematic, Hardware version, Software version, structure and internal photos are same, Model named differently due to marketing purposes. Should you have any questions or comments regarding this matter, please have my best attention. Sincerely, (Signed) Name / Title: July Meng / Sales Company: Zhongshan Dottsun Electronic Co., Ltd Address: 2nd road of guanglong, jinlong industrial park Zhongshan City, Guangdong 528411, China Phone: +86-760-88558060 Fax: +86-760-88558060 E-Mail: [email protected]

External Photos

Page1of4FCCID:2AXPN90-1680-8K ShenzhenLCSComplianceTestingLaboratoryLtd. Add:101,201BldgA&301BldgC,JujiIndustrialParkYabianxueziwei,ShajingStreet,BaoanDistrict,Shenzhen, 518000,China Tel:+(86)0755-82591330|E-mail:[email protected]|Web:www.lcs-cert.com Scancodetocheckauthenticity ExternalPhotosoftheEUT Fig.1 Fig.2 Page2of4FCCID:2AXPN90-1680-8K ShenzhenLCSComplianceTestingLaboratoryLtd. Add:101,201BldgA&301BldgC,JujiIndustrialParkYabianxueziwei,ShajingStreet,BaoanDistrict,Shenzhen, 518000,China Tel:+(86)0755-82591330|E-mail:[email protected]|Web:www.lcs-cert.com Scancodetocheckauthenticity Fig.3 Fig.4 Page3of4FCCID:2AXPN90-1680-8K ShenzhenLCSComplianceTestingLaboratoryLtd. Add:101,201BldgA&301BldgC,JujiIndustrialParkYabianxueziwei,ShajingStreet,BaoanDistrict,Shenzhen, 518000,China Tel:+(86)0755-82591330|E-mail:[email protected]|Web:www.lcs-cert.com Scancodetocheckauthenticity Fig.5 Fig.6 Page4of4FCCID:2AXPN90-1680-8K ShenzhenLCSComplianceTestingLaboratoryLtd. Add:101,201BldgA&301BldgC,JujiIndustrialParkYabianxueziwei,ShajingStreet,BaoanDistrict,Shenzhen, 518000,China Tel:+(86)0755-82591330|E-mail:[email protected]|Web:www.lcs-cert.com Scancodetocheckauthenticity Fig.7 Fig.8

ID Label/Location Info

Page1of1FCCID:2AXPN90-1680-8K ShenzhenLCSComplianceTestingLaboratoryLtd. Add:101,201BldgA&301BldgC,JujiIndustrialParkYabianxueziwei,ShajingStreet,BaoanDistrict,Shenzhen, 518000,China Tel:+(86)0755-82591330|E-mail:[email protected]|Web:www.lcs-cert.com Scancodetocheckauthenticity LABELANDLOCATION (Size:L38mmxW30mm)

Internal Photos

Page1of4FCCID:2AXPN90-1680-8K ShenzhenLCSComplianceTestingLaboratoryLtd. Add:101,201BldgA&301BldgC,JujiIndustrialParkYabianxueziwei,ShajingStreet,BaoanDistrict,Shenzhen, 518000,China Tel:+(86)0755-82591330|E-mail:[email protected]|Web:www.lcs-cert.com Scancodetocheckauthenticity InternalPhotosoftheEUT Fig.1 Fig.2 Page2of4FCCID:2AXPN90-1680-8K ShenzhenLCSComplianceTestingLaboratoryLtd. Add:101,201BldgA&301BldgC,JujiIndustrialParkYabianxueziwei,ShajingStreet,BaoanDistrict,Shenzhen, 518000,China Tel:+(86)0755-82591330|E-mail:[email protected]|Web:www.lcs-cert.com Scancodetocheckauthenticity Fig.3 Fig.4 Page3of4FCCID:2AXPN90-1680-8K ShenzhenLCSComplianceTestingLaboratoryLtd. Add:101,201BldgA&301BldgC,JujiIndustrialParkYabianxueziwei,ShajingStreet,BaoanDistrict,Shenzhen, 518000,China Tel:+(86)0755-82591330|E-mail:[email protected]|Web:www.lcs-cert.com Scancodetocheckauthenticity Fig.5 Fig.6 Page4of4FCCID:2AXPN90-1680-8K ShenzhenLCSComplianceTestingLaboratoryLtd. Add:101,201BldgA&301BldgC,JujiIndustrialParkYabianxueziwei,ShajingStreet,BaoanDistrict,Shenzhen, 518000,China Tel:+(86)0755-82591330|E-mail:[email protected]|Web:www.lcs-cert.com Scancodetocheckauthenticity Fig.7 Fig.8 BluetoothAntenna

RF Exposure Info

Page 1 of 9 FCCID:2AXPN90-1680-8KReportNo.:LCSA05296021EB ShenzhenLCSComplianceTestingLaboratoryLtd. Add:101,201BldgA&301BldgC,JujiIndustrialParkYabianxueziwei,ShajingStreet,BaoanDistrict,Shenzhen, 518000,China Tel:+(86)0755-82591330|E-mail:[email protected]|Web:www.lcs-cert.com Scancodetocheckauthenticity RFExposureEvaluation FOR ZhongshanDottsunElectronicCo.,Ltd WorkLight TestModel:FSl90-1680-8K AdditionalModelNo.:PleaseRefertoPage6 Preparedfor:ZhongshanDottsunElectronicCo.,Ltd Address: 2ndroadofguanglong,jinlongindustrialparkZhongshanCity, Guangdong,China Preparedby:ShenzhenLCSComplianceTestingLaboratoryLtd. Address: 101,201BldgA&301BldgC,JujiIndustrialParkYabianxueziwei, ShajingStreet,BaoanDistrict,Shenzhen,518000,China Tel:(+86)755-82591330 Fax:(+86)755-82591332 Web:www.LCS-cert.com Mail:[email protected] Dateofreceiptoftestsample:July14,2026 Numberoftestedsamples:2 SampleNo. : B260622027-1,B260622027-2 Serialnumber:Prototype DateofTest:July14,2026~July23,2026 DateofReport:July24,2026 Page 2 of 9 FCCID:2AXPN90-1680-8KReportNo.:LCSA05296021EB ShenzhenLCSComplianceTestingLaboratoryLtd. Add:101,201BldgA&301BldgC,JujiIndustrialParkYabianxueziwei,ShajingStreet,BaoanDistrict,Shenzhen, 518000,China Tel:+(86)0755-82591330|E-mail:[email protected]|Web:www.lcs-cert.com Scancodetocheckauthenticity RFExposureEvaluation ReportReferenceNo......................:LCSA05296021EB DateofIssue.......................................:July24,2026 TestingLaboratoryName..............:ShenzhenLCSComplianceTestingLaboratoryLtd. Address................................................: 101,201BldgA&301BldgC,JujiIndustrialParkYabianxueziwei, ShajingStreet,BaoanDistrict,Shenzhen,518000,China TestingLocation/Procedure............ : FullapplicationofHarmonisedstandardsâ–  PartialapplicationofHarmonisedstandardsâ–ˇ Otherstandardtestingmethodâ–ˇ Applicant’sName.............................: ZhongshanDottsunElectronicCo.,Ltd Address................................................: 2ndroadofguanglong,jinlongindustrialparkZhongshanCity, Guangdong,China TestSpecification Standard..............................................:FCCKDBpublication447498D01GeneralRFExposureGuidancev06 FCCCFR47part11.1310 FCCCFR47part22.1091 TestReportFormNo.........................:TRF-4-E-214A/0 TRFOriginator....................................:ShenzhenLCSComplianceTestingLaboratoryLtd. MasterTRF.........................................:Dated2011-03 ShenzhenLCSComplianceTestingLaboratoryLtd.Allrightsreserved. Thispublicationmaybereproducedinwholeorinpartfornon-commercialpurposesaslongastheShenzhen LCSComplianceTestingLaboratoryLtd.isacknowledgedascopyrightownerandsourceofthematerial. ShenzhenLCSComplianceTestingLaboratoryLtd.takesnoresponsibilityforandwillnotassumeliabilityfor damagesresultingfromthereader'sinterpretationofthereproducedmaterialduetoitsplacementand context. TestItemDescription.....................:WorkLight TradeMark..........................................:N/A TestModel...........................................:FSl90-1680-8K Ratings.................................................:PleaseRefertoPage6 Result..................................................:Pass Compiledby: Supervisedby:Approvedby: NickPeng/Administrator KevinHuang/RFManagerGavinLiang/Manager Page 3 of 9 FCCID:2AXPN90-1680-8KReportNo.:LCSA05296021EB ShenzhenLCSComplianceTestingLaboratoryLtd. Add:101,201BldgA&301BldgC,JujiIndustrialParkYabianxueziwei,ShajingStreet,BaoanDistrict,Shenzhen, 518000,China Tel:+(86)0755-82591330|E-mail:[email protected]|Web:www.lcs-cert.com Scancodetocheckauthenticity RFExposureEvaluation TestResultPass Thetestreportmerelycorrespondstothetestsample. Itisnotpermittedtocopyextractsofthesetestresultwithoutthewrittenpermissionofthetestlaboratory. TestReportNo.:LCSA05296021EB July24,2026 Dateofissue TestModel.............................. : FSl90-1680-8K EUT......................................... : WorkLight Applicant...............................:ZhongshanDottsunElectronicCo.,Ltd Address...................................:2ndroadofguanglong,jinlongindustrialparkZhongshan City,Guangdong,China Telephone...............................:/ Fax..........................................:/ Manufacturer.........................:FreshSourceInternational(Cambodia)Co.,Ltd Address...................................: NationalRoadNo.3,ChamPolVillage,Popel Commune,TramKak,District,TakeoProvince, KingdomofCambodia. Telephone...............................:/ Fax..........................................:/ Factory...................................: FreshSourceInternational(Cambodia)Co.,Ltd Address...................................: NationalRoadNo.3,ChamPolVillage,Popel Commune,TramKak,District,TakeoProvince, KingdomofCambodia. Telephone...............................:/ Fax..........................................:/ Page 4 of 9 FCCID:2AXPN90-1680-8KReportNo.:LCSA05296021EB ShenzhenLCSComplianceTestingLaboratoryLtd. Add:101,201BldgA&301BldgC,JujiIndustrialParkYabianxueziwei,ShajingStreet,BaoanDistrict,Shenzhen, 518000,China Tel:+(86)0755-82591330|E-mail:[email protected]|Web:www.lcs-cert.com Scancodetocheckauthenticity RevisionHistory ReportVersionIssueDateRevisionContentRevisedBy 000July24,2026InitialIssue--- Page 5 of 9 FCCID:2AXPN90-1680-8KReportNo.:LCSA05296021EB ShenzhenLCSComplianceTestingLaboratoryLtd. Add:101,201BldgA&301BldgC,JujiIndustrialParkYabianxueziwei,ShajingStreet,BaoanDistrict,Shenzhen, 518000,China Tel:+(86)0755-82591330|E-mail:[email protected]|Web:www.lcs-cert.com Scancodetocheckauthenticity TABLEOFCONTENTS DescriptionPage 1.ProductInformation...................................................................................................................................6 2.EvaluationMethod.....................................................................................................................................7 3.Limit................................................................................…

Text truncated - open the document above for the full version.

Test Report

Inverted F Antenna Specification Summary ITEMANT SPEC Model Name 2.4G ANT HorizontalVertical 2400MHz 2450MHz 2500MHz2400MHz 2450MHz 2500MHz Center Frequency -1.26 -0.76 -0.58 -5.25 -2.46 -1.86 MAX. Gain -0.58dBi PolarizationHorizontal and Vertical Azimuth Beam Pattern Omni-directional Impedance50 Ohm Antenna Length 38.20mm Manufacture ZHUHAI JIELI TECHNOLOGY CO.,LTD Antenna Photo & Length (mm) Address No. 333, Kexing Road, Xiangzhou District, Zhuhai City Horizontal: 2400 MHz 2450 MHz 2500 MHz Power (dBm) Max: 0 Min: -40 Scale: 5/div Gain (dB) Frequency (MHz) MaxMinAvg 2400-1.26174-30.0801-7.18716 2450-0.765802-36.5604-7.48023 2500-0.585582-22.0315-6.59127 Vertical: 2400 MHz 2450 MHz 2500 MHz Power (dBm) Max: 0 Min: -30 Scale: 5/div Gain(dB) Frequency (MHz) Max Min Avg 2400 -5.2537 -22.1424 -12.4294 2450 -2.4652 -24.5837 -10.4702 2500 -1.86120 -29.5214 -9.20432 ANT Test Labs:Attestation of Global Compliance Co., Ltd.

Test Report

Page 1 of 60 FCC ID: 2AXPN90-1680-8K Report No.: LCSA05296021EA Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity Appendix A RF Test Data for BT (Conducted Measurement) Product Name: Work Light Test Model: FSl 90-1680-8K Environmental Conditions Temperature: 23.7ď‚°C Relative Humidity: 51.9% ATM Pressure: 100.0 kPa Test Engineer: Jerry Chu Supervised by: Can Kun Page 2 of 60 FCC ID: 2AXPN90-1680-8K Report No.: LCSA05296021EA Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity A.1 -20dB Bandwidth Condition Mode Frequency (MHz) Antenna -20 dB Bandwidth (MHz) Limit -20 dB Bandwidth (MHz) Verdict NVNT 1-DH5 2402 Ant1 0.9517 No Limit Pass NVNT 1-DH5 2441 Ant1 0.9411 No Limit Pass NVNT 1-DH5 2480 Ant1 0.9885 No Limit Pass NVNT 2-DH5 2402 Ant1 1.287 No Limit Pass NVNT 2-DH5 2441 Ant1 1.277 No Limit Pass NVNT 2-DH5 2480 Ant1 1.282 No Limit Pass NVNT 3-DH5 2402 Ant1 1.289 No Limit Pass NVNT 3-DH5 2441 Ant1 1.301 No Limit Pass NVNT 3-DH5 2480 Ant1 1.291 No Limit Pass Page 3 of 60 FCC ID: 2AXPN90-1680-8K Report No.: LCSA05296021EA Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity -20dB Bandwidth NVNT 1-DH5 2402MHz Ant1 -20dB Bandwidth NVNT 1-DH5 2441MHz Ant1 Page 4 of 60 FCC ID: 2AXPN90-1680-8K Report No.: LCSA05296021EA Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity -20dB Bandwidth NVNT 1-DH5 2480MHz Ant1 -20dB Bandwidth NVNT 2-DH5 2402MHz Ant1 Page 5 of 60 FCC ID: 2AXPN90-1680-8K Report No.: LCSA05296021EA Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity -20dB Bandwidth NVNT 2-DH5 2441MHz Ant1 -20dB Bandwidth NVNT 2-DH5 2480MHz Ant1 Page 6 of 60 FCC ID: 2AXPN90-1680-8K Report No.: LCSA05296021EA Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity -20dB Bandwidth NVNT 3-DH5 2402MHz Ant1 -20dB Bandwidth NVNT 3-DH5 2441MHz Ant1 Page 7 of 60 FCC ID: 2AXPN90-1680-8K Report No.: LCSA05296021EA Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity -20dB Bandwidth NVNT 3-DH5 2480MHz Ant1 Page 8 of 60 FCC ID: 2AXPN90-1680-8K Report No.: LCSA05296021EA Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity A.2 Maximum Peak Conducted Output Power Condition Mode Frequency (MHz) Antenna Conducted Power (dBm) Limit Conducted(dBm) Verdict NVNT 1-DH5 2402 Ant1 -2.53 30 Pass NVNT 1-DH5 2441 Ant1 0.53 30 Pass NVNT 1-DH5 2480 Ant1 -0.33 30 Pass NVNT 2-DH5 2402 Ant1 -3.19 30 Pass NVNT 2-DH5 2441 Ant1 -0.11 30 Pass NVNT 2-DH5 2480 Ant1 -0.83 30 Pass NVNT 3-DH5 2402 Ant1 -2.79 30 Pass NVNT 3-DH5 2441 Ant1 0.28 30 Pass NVNT 3-DH5 2480 Ant1 -0.49 30 Pass Page 9 of 60 FCC ID: 2AXPN90-1680-8K Report No.: LCSA05296021EA Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity Peak Power NVNT 1-DH5 2402MHz Ant1 Peak Power NVNT 1-DH5 2441MHz Ant1 Page 10 of 60 FCC ID: 2AXPN90-1680-8K Report No.: LCSA05296021EA Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity Peak Power NVNT 1-DH5 2480MHz Ant1 Peak Power NVNT 2-DH5 2402MHz Ant1 Page 11 of 60 FCC ID: 2AXPN90-1680-8K Report No.: LCSA05296021EA Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity Peak Power NVNT 2-DH5 2441MHz Ant1 Peak Power NVNT 2-DH5 2480MHz Ant1 Page 12 of 60 FCC ID: 2AXPN90-1680-8K Report No.: LCSA05296021EA Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authentic…

Text truncated - open the document above for the full version.

Test Report

Page 1 of 37 FCCID:2AXPN90-1680-8KReportNo.:LCSA05296021EA ShenzhenLCSComplianceTestingLaboratoryLtd. Add:101,201BldgA&301BldgC,JujiIndustrialParkYabianxueziwei,ShajingStreet,BaoanDistrict,Shenzhen, 518000,China Tel:+(86)0755-82591330|E-mail:[email protected]|Web:www.lcs-cert.com Scancodetocheckauthenticity FCCTESTREPORT FOR ZhongshanDottsunElectronicCo.,Ltd WorkLight TestModel:FSl90-1680-8K AdditionalModelNo.:PleaseRefertoPage6 Preparedfor:ZhongshanDottsunElectronicCo.,Ltd Address: 2ndroadofguanglong,jinlongindustrialparkZhongshanCity, Guangdong,China Preparedby:ShenzhenLCSComplianceTestingLaboratoryLtd. Address: 101,201BldgA&301BldgC,JujiIndustrialParkYabianxueziwei, ShajingStreet,BaoanDistrict,Shenzhen,518000,China Tel:(+86)755-82591330 Fax:(+86)755-82591332 Web:www.LCS-cert.com Mail:[email protected] Dateofreceiptoftestsample:July14,2026 Numberoftestedsamples:2 SampleNo.:B260622027-1,B260622027-2 Serialnumber:Prototype DateofTest:July14,2026~July23,2026 DateofReport:July24,2026 Page 2 of 37 FCCID:2AXPN90-1680-8KReportNo.:LCSA05296021EA ShenzhenLCSComplianceTestingLaboratoryLtd. Add:101,201BldgA&301BldgC,JujiIndustrialParkYabianxueziwei,ShajingStreet,BaoanDistrict,Shenzhen, 518000,China Tel:+(86)0755-82591330|E-mail:[email protected]|Web:www.lcs-cert.com Scancodetocheckauthenticity FCCTESTREPORT FCCCFR47PART15C(15.247) ReportReferenceNo......................:LCSA05296021EA DateofIssue.......................................:July24,2026 TestingLaboratoryName..............:ShenzhenLCSComplianceTestingLaboratoryLtd. Address................................................: 101,201BldgA&301BldgC,JujiIndustrialParkYabianxueziwei, ShajingStreet,BaoanDistrict,Shenzhen,518000,China TestingLocation/Procedure............ : FullapplicationofHarmonisedstandardsâ–  PartialapplicationofHarmonisedstandardsâ–ˇ Otherstandardtestingmethodâ–ˇ Applicant’sName.............................:ZhongshanDottsunElectronicCo.,Ltd Address................................................: 2ndroadofguanglong,jinlongindustrialparkZhongshanCity, Guangdong,China TestSpecification Standard..............................................:FCCCFR47PART15C(15.247) TestReportFormNo.........................:TRF-4-E-148A/0 TRFOriginator....................................:ShenzhenLCSComplianceTestingLaboratoryLtd. MasterTRF.........................................:Dated2011-03 ShenzhenLCSComplianceTestingLaboratoryLtd.Allrightsreserved. Thispublicationmaybereproducedinwholeorinpartfornon-commercialpurposesaslongasthe ShenzhenLCSComplianceTestingLaboratoryLtd.isacknowledgedascopyrightownerandsourceofthe material.ShenzhenLCSComplianceTestingLaboratoryLtd.takesnoresponsibilityforandwillnot assumeliabilityfordamagesresultingfromthereader'sinterpretationofthereproducedmaterialduetoits placementandcontext. TestItemDescription.....................:WorkLight TradeMark..........................................:N/A TestModel...........................................:FSl90-1680-8K Ratings:PleaseRefertoPage6 Result..................................................:PASS Compiledby:Supervisedby:Approvedby: Nic…

Text truncated - open the document above for the full version.

Contact Information

Applicant

July Meng
[email protected]Fax: 0760 88552060

Technical Contact

HOORAY INDUSTRY LLCCindy Wu
[email protected]

1408 Pinon Place Fullerton, · California, 92835 · United States

Test Firm

Shenzhen LCS Compliance Testing Laboratory Ltd.Gavin Liang
[email protected]Fax: 0755-82591132

Technical Specifications

#Rule PartsFrequency RangePower Output
115C2.40 GHz - 2.48 GHz1.10 mW
Confidentiality
Long Term
Grant Notes
Power listed is maximum peak conducted output power. The product must be installed such that its antenna(s) can provide a separation distance of at least 20 cm from all persons and must not transmit simultaneously with any other transmitter, except in accordance with FCC multi-transmitter product procedures or as described in this filing.