2AXRGOCPICSDSCMATM protection

Oberthur Cash Protection

Application Details

Equipment Class
DXX - Part 15 Low Power Communication Device Transmitter
Date of Grant
Dec 20, 2020
Application Purpose
Original Equipment
Date of Application
Dec 20, 2020
Equipment Note
ATM protection
Frequency Range
915.02500000 - 915.62500000
Company
Oberthur Cash Protection
Country
France

Documents & Files

Select a file to view

Cover Letter(s)

↗
↗
↗

External Photos

ID Label/Location Info

↗
↗

Test Report

↗

Test Setup Photos

↗

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

Cover Letter(s)

ETABLISSEMENT PRINCIPAL (PLACE OF BUSINESS) : 3 BIS RUE DU DOCTEUR QUIGNARD – BP 67907 21079 DIJON CEDEX Tél. : + 33 (0)3 80 60 43 00 – Fax : + 33 (0)3 80 70 08 92 www.oberthurcp.com Siège social (Headquarters) : 7, avenue de Messine 75008 PARIS – France Tél. : + 33 (0)1 42 99 77 00 – Fax : + 33 (0)1 42 99 77 98 S.A. au capital de 2.445.000 € - RCS PARIS B 332 059 518 – SIRET 332 059 518 00057 APE 2630Z – TVA FR 12 332 059 Attn: TIMCO Engineering Inc. 849 N.W. State Road 45 P.O. Box 370 Newberry, Florida 32669 Authority to Act as Agent On our behalf, I appoint M. Olivier HEYER from Emitech Montpellier – 145 rue du Massacan – 34741 VENDARGUES CEDEX FRANCE, to act as our agent in the preparation of this application for equipment certification. I certify that submitted documents properly describe the device or system for which equipment certification is sought. I also certify that each unit manufactured, imported or marketed, as defined in the Federal Communications Commission’s regulations will have affixed to it a label identical to that submitted for approval with this application. For instances where our authorized agent signs the application for certification on our behalf, I acknowledge that all responsibility for complying with the terms and conditions for certification, as specified by TIMCO Engineering Inc., still resides with OBERTHUR CASH PROTECTION, 3bis rue docteur QUIGNARD, 21000 DIJON – FRANCE. This authorization is valid until further written notice from OBERTHUR CASH PROTECTION. The December 1 st 2020 By EZERZER Hugo, Embedded firmware manager

Cover Letter(s)

ETABLISSEMENT PRINCIPAL (PLACE OF BUSINESS) : 3 BIS RUE DU DOCTEUR QUIGNARD – BP 67907 21079 DIJON CEDEX Tél. : + 33 (0)3 80 60 43 00 – Fax : + 33 (0)3 80 70 08 92 www.oberthurcp.com Siège social (Headquarters) : 7, avenue de Messine 75008 PARIS – France Tél. : + 33 (0)1 42 99 77 00 – Fax : + 33 (0)1 42 99 77 98 S.A. au capital de 2.445.000 € - RCS PARIS B 332 059 518 – SIRET 332 059 518 00057 APE 2630Z – TVA FR 12 332 059 518 Federal Communications Commission Authorization and Evaluation Division Dijon – France, December 1 st 2020 Subject: Confidentiality Request regarding application for certification of FCC ID: 2AXRGOCPICSDSCM Applicant: EZERZER Hugo Product: OCP_G0289 Model: OCPICSDSCM To Whom It May Concern: Pursuant to Sections 0.457 and 0.459 of the Commission’s Rules, we hereby request confidential treatment of information accompanying this application as outlined below: Exhibit Type File Name Block Diagram OCPICSDSCM BlkDia.pdf Schematics OCPICSDSCM Schem.pdf Operational Description OCPICSDSCM Opdes.pdf NDA OCPICSDSCM Opdes1.pdf Parts List OCPICSDSCM PartsLst.pdf User Manual OCPICSDSCM UserMan.pdf Internal Photo OCPICSDSCM IntPho.pdf The above materials contain trade secrets and proprietary information not customarily released to the public. The public disclosure of these materials may be harmful to the applicant and provide unjustified benefits to its competitors. According to User Manual confidentiality, our aim is to get a long term one, in order to protect our knowhow:  Since our business is to secure ATM safe part and especially banknotes, it is really important that installation and user manual of such devices do not fall under a public access.  By the way, it could be helpful for thieves to have in their hands any information about which secure elements are provided to secure ATMs.  This document provides technical details on how the ATM are secured against criminal activities. Having such information made public would obviously weaken the protection we are offering our clients.  Moreover, such a document is not shared with any of our contacts unless a proper and signed NDA agreement has been signed before between both parties.  An example of NDA form is available on ‘OCPICSDSCM Opdes1.pdf’ file. ETABLISSEMENT PRINCIPAL (PLACE OF BUSINESS) : 3 BIS RUE DU DOCTEUR QUIGNARD – BP 67907 21079 DIJON CEDEX Tél. : + 33 (0)3 80 60 43 00 – Fax : + 33 (0)3 80 70 08 92 www.oberthurcp.com Siège social (Headquarters) : 7, avenue de Messine 75008 PARIS – France Tél. : + 33 (0)1 42 99 77 00 – Fax : + 33 (0)1 42 99 77 98 S.A. au capital de 2.445.000 € - RCS PARIS B 332 059 518 – SIRET 332 059 518 00057 APE 2630Z – TVA FR 12 332 059 518 We also require keeping internal photo file as confidential to permit to keep electronic parts and designs as secure as possible. The applicant understands that pursuant to Section 0.457 of the Rules, disclosure of this application and all accompanying documentation will not be made before the date of the Grant for this application. If you have any queries, please do not hesitate to contact us. Regards, EZERZER Hugo, December 1 st 2020

Cover Letter(s)

ETABLISSEMENT PRINCIPAL (PLACE OF BUSINESS) : 3 BIS RUE DU DOCTEUR QUIGNARD – BP 67907 21079 DIJON CEDEX Tél. : + 33 (0)3 80 60 43 00 – Fax : + 33 (0)3 80 70 08 92 www.oberthurcp.com Siège social (Headquarters) : 7, avenue de Messine 75008 PARIS – France Tél. : + 33 (0)1 42 99 77 00 – Fax : + 33 (0)1 42 99 77 98 S.A. au capital de 2.445.000 € - RCS PARIS B 332 059 518 – SIRET 332 059 518 00057 APE 2630Z – TVA FR 12 332 059 518 Dijon, December 1 st 2020 Subject: RADIO Certification of OCP_G0289 Applicant: EZERZER Hugo Product (PMN): OCP_G0289 Model (HVIN): OCPICSDSCM FCC ID: 2AXRGOCPICSDSCM IC ID: 26545-OCPICSDSCM To Whom It May Concern: We would like to submit the above product for Certification concerning FCC and Canadian rules. Please review all required documents enclosed. This application is dedicated to ATM protection range of products: based on ink staining solutions, it permits to reduce to zero the benefits of any kind of ATM attacks. . Compliance for RF exposure requirement was demonstrated in this test report. If you have any queries, please do not hesitate to contact us. Regards, EZERZER Hugo, December 1 st 2020

ID Label/Location Info

ETABLISSEMENT PRINCIPAL (PLACE OF BUSINESS) : 3 BIS RUE DU DOCTEUR QUIGNARD – BP 67907 21079 DIJON CEDEX Tél. : + 33 (0)3 80 60 43 00 – Fax : + 33 (0)3 80 70 08 92 www.oberthurcp.com Siège social (Headquarters) : 7, avenue de Messine 75008 PARIS – France Tél. : + 33 (0)1 42 99 77 00 – Fax : + 33 (0)1 42 99 77 98 S.A. au capital de 2.445.000 € - RCS PARIS B 332 059 518 – SIRET 332 059 518 00057 APE 2630Z – TVA FR 12 332 059 518 On main board - HVIN : OCPICSDSCM  Stick on the bottom face of the electronic board On Host - HMV : OCP_SCM  Stick on the upper face of the board housing

ID Label/Location Info

ETABLISSEMENT PRINCIPAL (PLACE OF BUSINESS) : 3 BIS RUE DU DOCTEUR QUIGNARD – BP 67907 21079 DIJON CEDEX Tél. : + 33 (0)3 80 60 43 00 – Fax : + 33 (0)3 80 70 08 92 www.oberthurcp.com Siège social (Headquarters) : 7, avenue de Messine 75008 PARIS – France Tél. : + 33 (0)1 42 99 77 00 – Fax : + 33 (0)1 42 99 77 98 S.A. au capital de 2.445.000 € - RCS PARIS B 332 059 518 – SIRET 332 059 518 00057 APE 2630Z – TVA FR 12 332 059 518 Label stuck on the PCB: Label stuck on the final product:

Test Report

Siège Social : Em i t ec h - 3, avenue des Coudrie rs - Z.A. de l ’Observatoire - 78180 MONTIGNY LE BX - Fr a nc e Siret : 344 545 645 00022 - Tél. : 33 (0)1 30 57 55 55 - Fax : 33 (0)1 30 43 74 48 - E-ma i l : c on ta ct @emit ec h. fr - URL : www.emitech.fr SAS au capital de 1 560 000 € - R.C.S. VERSAILLES 344 545 6 45 - APE 7112B RR410-20-103551-1A Ed.0 Duplication of this test report is only permitted for an integral photographic facsimile. It includes the numb er of pages referenced here ab ove. This document is the result of testing a specimen or a sample of the product sub mitted. It does not imply an assessment of the conformity of the whole manufactured products of the tested sample. LISTE DES SITES ACCREDITES ET PORTEES D IS PO N IBL ES S U R W W W .CO FRAC.FR ACCRE D IT AT IO N S N ° 1- 0107, 1-0826, 1-0827, 1-1925, 1- 2069,1-2070, 1-2206, 1-2376 & 1- 6086 Test report issued under the responsibility of: EMITECH MONTPELLIER laboratory MRA US-EU Designation Number: FR0006 (FCC#: 954701) Canadian CAB Identifier: FR0003 (ISED#: 4379C) RADIO TEST REPORT FCC part 15.249 RSS-210, issue 10, April 2020 Company...................................... : Oberthur Cash Protection Address......................................... : 3 Bis rue du Docteur Quignard 21000 DIJON FRANCE Test item description. .................. : IBNS ATM de vice s Trad e Ma rk. ................................... : Oberthur Cash Protection Manufacturer. ................................ : Oberthur Cash Protection Model/ Type reference..................... : OCPICSDSCM / OCP_SCM FCC ID .......................................... : 2AXRGOCPICS DS CM IC. ................................................. : 26545-OCPICSDS CM Ratings.......................................... : 99Vac/60Hz to 121Vac/60Hz + 6Vdc to 7,2Vdc (internal battery) Testing Laboratory....................... : EMITECH MONTPELLIER laboratory Address......................................... : 145 rue de Massacan 34740 VENDARGUES FRANCE Report Reference No. ................... : RR410-20-103551-1A Test procedure............................... : FCC IC Certification Diffusion. ....................................... : Mr. EZERZER Applicant’s nam e............................ : Oberthur Cash Protection Date of issue. ................................ : December 2, 2020 Total num ber of pages.................... : 54 Revision. ....................................... : 0 Modi fied page(s). ........................... : Creation Com piled by. ................................. : Olivier AELBRECHT Approved by (+ signat ure). ............. : David MONTAULON (Technical Manager) RR410-20-103551-1A Ed.0 Page 2 on 54 REP ORT INDEX: 1. GENERAL INF ORMATIO NS ................................................................................................................. 3 2. REF ERENCE DO CUM ENT(S)............................................................................................................... 4 3. EQ UIPM ENT T ECHNICAL DES CRIPTIO N ............................................................................................ 5 3.1. TES T CO ND IT IO NS ......................................................................................................................... 5 3.2. EUT GE N ERA L VI EW...................................................................................................................... 5 3.3. EUT GEN ERA L WIT H ALL SENS ORS A N D POW ER S U PPLY CO NN EC T ED ................................................... 6 3.4. EUT MA RKING PLATE .................................................................................................................... 6 3.5. EUT MECHA N ICA L A ND ELECT R ICA L DES IG N ..................................................................................... 7 3.6. EUT IN PUT/OUT PUT PO RTS ............................................................................................................ 8 3.7. SU PPO RT ING EQUIPMENT US ED DURING TES T ................................................................................... 9 3.8. EUT RA D IO SPEC I F ICA T IO NS......................................................................................................... 10 4. OPINION(S) AND INT ERP R ET ATIO N(S)............................................................................................. 10 5. RESULT SUMMARY .......................................................................................................................... 11 6. MEASUREM ENT UNCERTAINT Y ....................................................................................................... 12 7. TEST CONDITIO NS AND RES ULTS ................................................................................................... 13 7.1. CO ND U CT ED EMISS ION (MEA SUREMENT) ......................................................................................... 13 7.2. DUTY CY CL E OF TEST SIG NA L ....................................................................................................... 16 7.3. TRA NS MIT T ER RA D IA T ED S PURIOUS EMISS IONS AT FREQUENCIES <30MHZ ........................................... 18 7.4. TRA NS MIT T ER RA D IA T ED S PURIOUS EMISS IONS AT FREQUENCIES >30MHZ ........................................... 23 7.5. BA ND-E DG E CO M PL IA N C E ............................................................................................................. 33 7.6. EFFECTIV E ISOTOROPIC RA D IA T ED POW ER....................................................................................... 38 7.7. OC CU PIED BA N DW IDT H ................................................................................................................ 46 7.8. FREQUENCY ERROR ..................................................................................................................... 51 REV ISION HIST ORY: Revision Da te Modified pages Modifications 0 December 2, 2020 / Creation RR410-20…

Text truncated - open the document above for the full version.

Test Setup Photos

RR410-20-103551-1A Ed.0 Page 14 on 54 CONDUC T ED EM ISSION (M EA S UREM ENT) - TA BUL A T ED RESULTS ALIMENTATION AC / 110VAC/60HZ EMI4729 Terminal T e st Frequency (MHz) Meter Reading dB (μV) De te ctor (Pk/QP/Av) Gain/Loss Factor (dB) Level dB (μV) Limit dB (μV) Margin (dB) / / / / / / / / Supplementary information: No spurious emissions were detected. TEST SETUP PHOT O(S) RR410-20-103551-1A Ed.0 Page 19 on 54 TRA NSM IT T ER RA DIA T ED SPURIOUS EM ISSIONS AT FREQUENC I ES <30MHZ - TA BUL A T ED RESULTS Frequency (MHz) Antenna Position Level (dBμA/m) Limit (dBμA/m) N/A N/A N/A N/A No spurious emissions were detected. TEST SETUP PHOT O(S) – EUT POSITION TEST SETUP PHOT O(S) RR410-20-103551-1A Ed.0 Page 27 on 54 TEST SETUP PHOT O(S) – EUT POSITION FOR FREQ < 1GHZ TEST SETUP PHOT O(S) – EUT POSITION FOR FREQ > 1GHZ RR410-20-103551-1A Ed.0 Page 28 on 54 TEST SETUP PHOT O(S) – 30MHZ < FOR FREQ < 200MHZ TEST SETUP PHOT O(S) - 200MHZ < FOR FREQ < 1GHZ RR410-20-103551-1A Ed.0 Page 29 on 54 TEST SETUP PHOT O(S) - FOR FREQ > 1GHZ

Contact Information

Applicant

Hugo EZERZER(Embedded firmware manager)
[email protected]0380604303Fax: +33380700892

Test Firm

EMITECH MontpellierOlivier HEYER
[email protected]33-4-67-871102Fax: 33-4-67-709455

Technical Specifications

#Rule PartsFrequency RangePower Output
115C915.025 MHz - 915.625 MHz-
Confidentiality
Long Term