Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.
Doc. Nr.: 20210205001 Version: 1.2 Status: REVIEW Classification: PUBLIC © 2021 Hardstrasse 201 8005 Zürich, Switzerland Telephone: +41 44 275 51 51 Email: [email protected] www.nexxiot.com Technical Data Installation Manual Certificates This manual is an application example of the Loadtracker for a freight wagon with the UIC standard bogie type Y25 with I-beam profile. Other bogie types may have a different mounting position and may require additional mounting material. Before equipping a wagon according to these instructions, the procedure must be agreed with the person responsible entity in charge of maintenance (ECM) of the wagon. Loadtracker 1.0 Empty-Full Sensor User Manual - - Loadtracker 1.0 Empty-Full Sensor - User Manual © 2021 nexxiot.com Doc. Nr.: 20210205001 Version: 1.2 Status: REVIEW Classification: PUBLIC - 2 - Table of Contents 1 Revision History ........................................................................................................................................................................................................................ 3 2 Technical Data ........................................................................................................................................................................................................................... 4 3 Certifications................................................................................................................................................................................................................................ 5 4 Important .......................................................................................................................................................................................................................................6 5 Product Information ............................................................................................................................................................................................................... 7 5.1 Safety Notice ................................................................................................................................................................................................................ 7 5.2 Device Identification EU Version.................................................................................................................................................................... 7 5.3 Functional Description........................................................................................................................................................................................... 8 5.4 Warning Label ............................................................................................................................................................................................................. 8 5.5 Installation Instruction ............................................................................................................................................................................................ 9 5.6 Maintenance Instruction ....................................................................................................................................................................................... 9 5.7 Cleaning ........................................................................................................................................................................................................................... 9 5.8 Device Replacement Instructions ................................................................................................................................................................. 9 5.9 Decommissioning an Old Device .................................................................................................................................................................. 9 6 Installation and Mounting Guide................................................................................................................................................................................ 10 6.1 Important Safety Notice .................................................................................................................................................................................... 10 6.2 Material Lists (Mounting Kit) ........................................................................................................................................................................... 10 6.3 Workshop Equipment ......................................................................................................................................................................................... 10 6.4 Required Tools ......................................................................................................................................................................................................... 10 6.5 Consumables ............................................................................................................................................................................................................ 10 6.6 Explanation Coordinate System Freight Railcar - Indicators .................................................................................................. 11 7 Notes on the Devices ......................................................................................................................................................................................................... 12 7.1 Loadtracker ................................................................................................................................................................................................................. 12 7.2 Rotary Brush.........................................................................…
Text truncated - open the document above for the full version.
Hardstrasse 201 8005 Zürich, Switzerland Telephone: +41 44 275 51 51 Email: [email protected] www.nexxiot.com RE: CONFIDENTIALITY REQUEST FOR LOADTRACKER 1.0 EX / A SL.1 A, FCC ID: 2AXRX-ASL1A To Whom It May Concern: This letter serves as an official request for confidentiality under sections 0.457 and 0.459 of CFR 47. We have requested that the Block Diagram, Schematics, Internal Photos and Operational Description required to be submitted with this application be permanently withheld from public review. The product uses high-end technology with customized components to fulfill European and North American hazardous location, radio equipment and harsh environment requirements. As such, it is a unique product. The above-mentioned documents contain detailed system and equipment descriptions and proprietary information about the product that should never get into the possession of our competition. The information contained in the Internal Photos exhibit is restricted from disclosure to non- consumers. The interior of the final product is encapsulated and enclosed. The provided internal photos show a non-encapsulated interior which is proprietary information. Please contact me if there is any information you may need. Sincerely, Dominik Dumančić (Certification Engineer) 26th March 2021 Eurofins E&E North America 914 West Patapsco Avenue Baltimore, MD 21230
Hardstrasse 201 8005 Zürich, Switzerland Telephone: +41 44 275 51 51 Email: [email protected] www.nexxiot.com RE: Short Term Confidentiality Request For LOADTRACKER 1.0 EX / A SL.1 A, FCC ID: 2AXRX-ASL1A To Whom It May Concern: This letter serves as an official request for confidentiality under sections 0.457 and 0.459 of CFR 47, Nexxiot requests short-term Confidentiality of following sections of this application for a period of 180 days after grant is issued. External Photos Test Setup Photos User Manual These documents contain detailed system and equipment descriptions and related information about the product, which Nexxiot considers to be proprietary, confidential, and a custom design and otherwise, would not release to the general public. Since this design is a basis from which future technological products will evolve, Nexxiot feels that this information would be of benefit to its competitors, and that the disclosure of the information in these documents would give our competitors an unfair advantage in the market. Please contact me if there is any information you may need. Sincerely, Dominik Dumančić (Certification Engineer) 26th March 2021 Eurofins E&E North America 914 West Patapsco Avenue Baltimore, MD 21230
LOADTRACKER 1.0 EX ASL.1A SERIAL NUMBER 2018/000000000 HARDSTRASSE 201, CH-8005 ZURICH, SWITZERLAND WARNING: POTENTIAL ELECTROSTATIC DISCHARGE RISK - SEE MANUAL. DO NOT OPEN EPT 20 ATEX 3600 X IECEx EUT 20.0004 X II 2 GD 1258 Ex ib IIC T4 Gb Ex ib IIIC T135°C Db IP Rating: IP66/67 T. Amb.: -35°C ... +60°C Class I Zone 1 AEx ib IIC T4 Class II Zone 21 AEx ib IIIC T135°C Gb Db Class I, II, III, Division 2 Groups A, B, C, D, F, G, T4 Electrical and Hazardous Location Safety E000000 FCC ID: 2AXRX-ASL1A IC: 26682-ASL1A
Nexxiot Maximum Permissible Exposure Loadtracker 1.0 EX CFR Title 47 Part 1 Report: WIRS111879-FCC-RF Exposure Rev. 2 © 2021, Eurofins E&E North America Page 1 of 1 Maximum Permissible Exposure RF Exposure Requirements: §1.1307(b)(1) and §1.1307(b)(2): Systems operating under the provisions of this section shall be operated in a manner that ensures that the public is not exposed to radio frequency energy levels in excess of the Commission’s guidelines. RF Radiation Exposure Limit: §1.1310: As specified in this section, the Maximum Permissible Exposure (MPE) Limit shall be used to evaluate the environmental impact of human exposure to radiofrequency (RF) radiation as specified in Sec. 1.1307(b), except in the case of portable devices which shall be evaluated according to the provisions of Sec. 2.1093 of this chapter. RF Exposure Limits S = PG / 4π ππ πR 2 or R = √(PG / 4π ππ πS) where, S = Power Density (mW/cm 2 ) P = Power Input to antenna (mW) G = Antenna Gain (numeric value) R = Distance (cm) For Antenna Gain dBi = 10log(Numeric) Bands covered under FCC Part 15.247 Test Results: Band Frequency (MHz) Maximum Conducted Power (dBm) Conducted Power (mW) Antenna Gain (dBi) Antenna Gain (Numeric) Power Density (mW/cm2) Limit (mW/cm2) Margin Distance (cm) Result ZigBee 2405 4.749 2.984 3.50 2.238 0.0013 1 -0.998 20 Pass MPE Calculation for Bands under Part 15.247 The safe distance where Power Density is less than the MPE limit listed above was found to be 20 cm.
HEADQUARTERS: 914 WEST PATAPSCO AVENUE • BALTIMORE, MARYLAND 21230 • PHONE (410) 354-3300 • FAX (410) 354-3313 Maryland | California | Texas www.metlabs.com May 14, 2021 Nexxiot Prime Tower Hardstrasse 201 Zurich, Switzerland 8005 Dear Dominik Dumancic, Enclosed is the EMC Wireless test report for compliance testing of the Nexxiot, Loadtracker 1.0 EX as tested to the requirements of Title 47 of the CFR, Ch. 1 (10-1-06 ed.), Part 15 Subpart C for Intentional Radiators. Thank you for using the services of Eurofins E&E North America. If you have any questions regarding these results or if we can be of further service to you, please feel free to contact me. Sincerely yours, EUROFINS E&E NORTH AMERICA Michelle Tawmging Documentation Department Reference: (\Nexxiot\WIRS111879-FCC-247 ZigBee Rev.2) Certificates and reports shall not be reproduced except in full, without the written permission of Eurofins E&E North America. While use of the A2LA logo in this report reflects MET accreditation under these programs, the report must not be used by the client to claim product certification, approval, or endorsement by A2LA or any agency of the Federal Government. This letter of transmittal is not a part of the attached report. Eurofins MET Laboratories Inc. (Eurofins E&E North America) is part of the Eurofins Electrical & Electronics (E&E) global compliance HEADQUARTERS: 914 WEST PATAPSCO AVENUE • BALTIMORE, MARYLAND 21230 • PHONE (410) 354-3300 • FAX (410) 354-3313 Report: WIRS111879-FCC-247 ZigBee Rev. 2 © 2021, Eurofins E&E North America Page ii of vi Electromagnetic Compatibility Criteria Test Report for the Nexxiot Loadtracker 1.0 EX Tested under the FCC Certification Rules contained in 15.247 Subpart C for Intentional Radiators Report: WIRS111879-FCC-247 ZigBee Rev. 2 May 14, 2021 Prepared For: Nexxiot Prime Tower Hardstrasse 201 Zurich, Switzerland 8005 Prepared By: Eurofins E&E North America 3162 Belick Street Santa Clara, CA 95054 Nexxiot Electromagnetic Compatibility Loadtracker 1.0 EX CFR Title 47, Part 15.247 Report: WIRS111879-FCC-247 ZigBee Rev. 2 © 2021, Eurofins E&E North America Page iii of vi Electromagnetic Compatibility Criteria Test Report for the Nexxiot Loadtracker 1.0 EX Tested under the FCC Certification Rules contained in 15.247 Subpart C for Intentional Radiators Arsalan Hasan Manager, Wireless Laboratory Engineering Statement: The measurements shown in this report were made in accordance with the procedures indicated, and the emissions from this equipment were found to be within the limits applicable. I assume full responsibility for the accuracy and completeness of these measurements, and for the qualifications of all persons taking them. It is further stated that upon the basis of the measurements made, the equipment tested is capable of operation in accordance with the requirements of the FCC Rules Part 15.247 under normal use and maintenance. Eleazar Zuniga, PhD. Director, Wireless Technologies Nexxiot Electromagnetic Compatibility Loadtracker 1.0 EX CFR Title 47, Part 15.247 Report: WIRS111879-FCC-247 ZigBee Rev. 2 © 2021, Eurofins E&E North America Page iv of vi Report Status Sheet Revision Report Date Reason for Revision ∅ April 22, 2021 Initial Issue. 1 May 11, 2021 TCB Updates. 2 May 14, 2021 TCB Updates. Nexxiot Electromagnetic Compatibility Loadtracker 1.0 EX CFR Title 47, Part 15.247 Report: WIRS111879-FCC-247 ZigBee Rev. 2 © 2021, Eurofins E&E North America Page v of vi Table of Contents I. Executive Summary ................................................................................................................................................ 1 A. Purpose of Test ................................................................................................................................................... 2 B. Executive Summary ........................................................................................................................................... 2 II. Equipment Configuration ....................................................................................................................................... 3 A. Overview ............................................................................................................................................................ 4 B. References .......................................................................................................................................................... 4 C. Test Site.............................................................................................................................................................. 5 D. Measurement Uncertainty .................................................................................................................................. 5 E. Description of Test Sample ................................................................................................................................ 5 F. Equipment Configuration ................................................................................................................................... 5 G. Support Equipment ............................................................................................................................................. 6 H. Ports and Cabling Information ........................................................................................................................... 6 I. Mode of Operation During Testing .................................................................................................................... 6 J. Method of Monitoring EUT Operation .............................................................................................................. 6 K. Modifications ..................................................................................................................................................... 6 a) Modifications to EUT ...................................…
Text truncated - open the document above for the full version.
Nexxiot Electromagnetic Compatibility Loadtracker 1.0 EX CFR Title 47, Part 15.247 & RSS.247, Issue 2, February 2017 Report: WIR111879 Test Setup Photos Rev. 1 © 2021, Eurofins E&E North America Page 1 of 1 Radiated Spurious Emissions, Below 1GHz, Test Setup Radiated Spurious Emissions, Above 1GHz, Test Setup
Hardstrasse 201 · Zurich · Switzerland
| # | Rule Parts | Frequency Range | Power Output |
|---|---|---|---|
| 1 | 15C | 2.40 GHz - 2.48 GHz | 2.90 mW |

Tracker device
Equipment Class
JAB - Part 15 Class B Digital Device
Globehopper Crossmodal 3.0
Equipment Class
DTS - Digital Transmission System