2AXVDMW-0172Microwave sensor module

Huizhou Yuansheng Technology Co.,Ltd
Microwave sensor module - FCC ID 2AXVDMW-0172 - Huizhou Yuansheng Technology Co.,Ltd
Click to zoom

Application Details

Equipment Class
DXX - Part 15 Low Power Communication Device Transmitter
Date of Grant
Nov 09, 2020
Application Purpose
Original Equipment
Date of Application
Nov 09, 2020
Equipment Note
Microwave sensor module
Frequency Range
5850.00000000 - 5875.00000000
Company
Huizhou Yuansheng Technology Co.,Ltd
Country
China

Documents & Files

Select a file to view

Users Manual

↗

Cover Letter(s)

↗
↗
↗

External Photos

↗

ID Label/Location Info

↗

Internal Photos

↗

Test Report

↗

Test Setup Photos

↗

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

Users Manual

File no.: QR004 REV.A Huizhou Yuansheng Technology Co.,Ltd Address: Zhongkai High-tech Zones on 16th. HuiFengEast No. 2 road, Building B Room 516,518, Huizhou city, Guangdong Province, China Tel.: +86-752-3133399 Fax: +86-752-3228395 Website: www.cnmicrowavesensor.com 1 / 5 To be the most professional digital switches manufacturer that provides best service! SPECIFICATION FOR APPROVAL Part name: Microwave sensor module Model no.: MW-0172 Date: 2020-9- 19 Signed by customer Made by Signed by R&D dept. Signed by Sales dept. Approved by File no.: QR004 REV.A Huizhou Yuansheng Technology Co.,Ltd Address: Zhongkai High-tech Zones on 16th. HuiFengEast No. 2 road, Building B Room 516,518, Huizhou city, Guangdong Province, China Tel.: +86-752-3133399 Fax: +86-752-3228395 Website: www.cnmicrowavesensor.com 2 / 5 To be the most professional digital switches manufacturer that provides best service! Revision Model No. Modifications Processing stage Date A0 MW-0172 / MP 2019/09/19 Part picture Part description ā—That Doppler technology helps to catch tiny actions and the lights can turn on or off lights automatically based on your setting. It can be hidden in the lights made from various non-metal materials without damaging the exterior of the lights. This advantage helps to upgrade the traditional light into digital light to achieve the purpose of operation convenience and energy saving. ā—Working diagram: Power supply No power supply Output 1S 1S Start working File no.: QR004 REV.A Huizhou Yuansheng Technology Co.,Ltd Address: Zhongkai High-tech Zones on 16th. HuiFengEast No. 2 road, Building B Room 516,518, Huizhou city, Guangdong Province, China Tel.: +86-752-3133399 Fax: +86-752-3228395 Website: www.cnmicrowavesensor.com 3 / 5 To be the most professional digital switches manufacturer that provides best service! Electrical parameters Frequency 5850MHz~5875MHz Rated Voltage Input:7-12V~, <50mA Output:5V~,>2mA Output PWM Driving current 40mA Radiated power <1mW Detection range Frontal 4M±1M Operating temperature -25°C~+75°C Storage temperature -30°C~+80°C Environmental protection IP20 Life time Minx. 5 years Criteria CE/TUV/ETL/FCC Dimension 20MM*20MM*5MM(±0.5MM) Wiring: Groun PWM Power supply 5V DC±5% Pin description G for Ground 0 for PWM V for Power supply File no.: QR004 REV.A Huizhou Yuansheng Technology Co.,Ltd Address: Zhongkai High-tech Zones on 16th. HuiFengEast No. 2 road, Building B Room 516,518, Huizhou city, Guangdong Province, China Tel.: +86-752-3133399 Fax: +86-752-3228395 Website: www.cnmicrowavesensor.com 4 / 5 To be the most professional digital switches manufacturer that provides best service! Product Usage Notes: 1.It is not recommended for outdoor use. It will cause false triggering when it rains. 2.The detection range and angle will be affected by the surrounding environment. Please make the sensor away from working instruments, fans, moving gutter, etc. 3.The greater the density of object at a same size is, the more sensitive is. 4.Induction of objects moving at a uniform speed will deteriorate. Walk and stop is suggested. The most sensitivity is based on the movement with a speed of 0.3-1m/second. 5.The detection performance at front is better than either side of sensor. 6.The installation position cannot have vibration. 7.Requires the power supply ripple is less than 100mV. 8.There is a big tolerance of the lux value for the different standard of light source. The ambient light needs to be under the setting value, and the daylight function can be tested. 9.To avoid the possible interference and ensure the effect of testing, please keep two or more microwave sensors with a distance of over 1m. 10.Microwave can have penetration effect, but cannot penetrate reinforced concrete walls and metal objects. Please make sure the room for testing is sufficient for the detection range. 11. Microwave sensor module for lamps, cameras, billboards, smart mirrors, smart toilets, smart home products. Room wall Room wall File no.: QR004 REV.A Huizhou Yuansheng Technology Co.,Ltd Address: Zhongkai High-tech Zones on 16th. HuiFengEast No. 2 road, Building B Room 516,518, Huizhou city, Guangdong Province, China Tel.: +86-752-3133399 Fax: +86-752-3228395 Website: www.cnmicrowavesensor.com 45/ 5 To be the most professional digital switches manufacturer that provides best service! FCC Warning This device complies with part 15 of the FCC rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any inte rference received, including interference that may cause undesired operation. Changes or modifications not expressly approved by the party responsible for compliance could void the user's authority to operate the equipment. NOTE: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interferenceto radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures: • Reorient or relocate the receiving antenna. • Increase the separation between the equipment and receiver. • Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. • Consult the dealer or an experienced radio/TV technician for help. Radiation Exposure Statement This equipment complies with FCC radiation exposure limits set forth for an uncontrolled environment. This equ…

Text truncated - open the document above for the full version.

Cover Letter(s)

HuizhouYuanshengTechnologyCo.,Ltd AgentAuthorization Company:HuizhouYuanshengTechnologyCo.,Ltd Address:ZhongkaiHigh-techZoneson16th.HuiFengEastNo.2road,BuildingB Room516,518,Huizhoucity,GuangdongProvince,China ProductName:Microwavesensormodule TradeMark:N/A ModelNumber(s):MW-0172 FCCID:2AXVDMW-0172 WeauthorizeMiCOMLabsInc.,575BoulderCourt,Pleasanton,California94566,USA, toactonourbehalfonallmattersconcerningthecertificationofabovenamed equipment. WedeclarethatMiCOMLabsInc.isallowedtoforwardallinformationrelatedtothe approvalandcertificationofequipmenttotheregulatoryagenciesasrequiredandto discussanyissuesconcerningtheapprovalapplication.Anyandallactscarriedoutby MiCOMLabsonourbehalfshallhavethesameeffectasactsofourown. Signature:Date:2020-11-05 Name:ChunHuaWu Title:Manager Company:HuizhouYuanshengTechnologyCo.,Ltd

Cover Letter(s)

HuizhouYuanshengTechnologyCo.,Ltd FCCModularApprovalRequestRev3.0 FederalCommunicationsCommission EquipmentAuthorizationDivision 7435OaklandMillsRoad Columbia,MD21046 USA Date: Subject;ModularTransmitterApplication Companyname:HuizhouYuanshengTechnologyCo.,Ltd FCCID:2AXVDMW-0172 DearSir/Madam, ThisletterincludestheFCCapplicationrequirementsforModularTransmitterApprovalRequest for;- FCCKDB996369D01ā€˜ModuleCertificationGuidev02;and FCCKDB996369D03OEMManualv01 Inaccordancewith47CFR15.212ModularTransmittersandKDB996369D01ā€˜ModuleEquip AuthGuidev02’.FCCID2AXVDMW-0172hasbeenexaminedagainstthefollowing requirements. Requirementper15.212andKDB996369D01ExplanationfromGrantee (donotwriteyes/no,butexplainwhyproduct complies/howitisachieved) Theradioelementsmusthavetheradiofrequencycircuitry shielded.Physicalcomponentsandtuningcapacitor(s)maybe locatedexternaltotheshield,butmustbeonthemodule assembly. NO Themodulemusthavebufferedmodulation/datainputstoensure thatthedevicewillcomplywithPart15requirementswithanytype ofinputsignal. NO Themodulemustcontainpowersupplyregulationonthemodule. YES Themodulemustcontainapermanentlyattachedantenna,or containauniqueantennaconnector,andbemarketedand operatedonlywithspecificantenna(s),per§§15.203,15.204(b), 15.204(c),15.212(a),2.929(b). YES Themodulemustdemonstratecomplianceinastand-alone configuration. YES ThemodulemustbelabeledwithitspermanentlyaffixedFCCID label,oruseanelectronicdisplay(seeKDBPublication784748). NO Themodulemustcomplywithallspecificrulesapplicabletothe transmitter,includingalltheconditionsprovidedintheintegration instructionsbythegrantee. YES ThemodulemustcomplywithRFexposurerequirements TES HuizhouYuanshengTechnologyCo.,Ltd FCCModularApprovalRequestRev3.0 IntegrationInstructionsforhostproductmanufacturers ThefollowingitemsaresubmittedinsupportofapplicationforModularTransmitterFCCIDas notedaboveasrequiredbytheFCCKDB996369D03OEMManualv01. Theseitemsareprovidedasintegrationinstructionsforhostproductmanufacturers(e.g.,OEM instructionmanual)tousewhenintegratingamoduleinahostproduct. AnyrequirementsthatarenotapplicabletotheModuleareasindicatedbelow. SummaryofrequirementsandChecklist.RefertotheKDBfordescriptionofthecompleterequirements; KDB RefSect RequirementsofKDB996369D03UserManualPageNumber reference 2.2ListofapplicableFCCrules 2.3Summarizethespecificoperationaluseconditions 2.4Limitedmoduleprocedures 2.5Traceantennadesigns 2.6RFexposureconsiderations 2.7Antennas 2.8Labelandcomplianceinformation 2.9Informationontestmodesandadditionaltesting requirements 2.10Additionaltesting,Part15SubpartBdisclaimer Name:ChunHuaWuDate:2020-11-05 Title:Manager Signatureofapplicant

Cover Letter(s)

HuizhouYuanshengTechnologyCo.,Ltd OfficeofEngineeringTechnology FederalCommunicationsCommission 7435OaklandMillsRoad Columbia,MD21046 USA Date:2020-11-05 Subject;RequestforConfidentiality FCCID:2AXVDMW-0172 ToWhomItMayConcern, PursuanttotheprovisionsoftheCommission’srulesTitle47Sections§0.457and§0.459,we arerequestingtheCommissiontowithholdthefollowingattachment(s)asconfidential documentsfrompublicdisclosureindefinitely. Thesedocumentscontaindetailedsystemandequipmentdescriptionsandareconsideredas proprietaryinformationinoperationoftheequipment.Thepublicdisclosureofthesedocuments mightbeharmfultoourcompanyandwouldgivecompetitorsanunfairadvantageinthemarket. SchematicDiagram BlockDiagram PartsList OperationalDescription Tune-upProcedure Inadditionaltoabovementioneddocuments,inordertocomplywiththemarketingregulations inTitle47CFR§2.803andtheimportationrulesinTitle47CFR§2.1204,whileensuringthat businesssensitiveinformationremainsconfidentialuntiltheactualmarketingofnewly authorizeddevices,werequestShortTermConfidentialityofthefollowingattachment(s); ExternalPhotos TestSetupPhotos InternalPhotos UserManual For45days,pursuanttoPublicNoticeDA04-1705. OR For180dayspursuanttoKDB726920D01. Itisourunderstandingthatallmeasurementtestreports,FCCIDlabelformatand correspondenceduringthecertificationreviewprocesscannotbegrantedasconfidential documentsandthisinformationwillbeavailableforpublicreviewoncethegrantofequipment authorizationisissued. Sincerely, Signature: Name:ChunHuaWu Title:Manager

External Photos

SHENZHENLCSCOMPLIANCETESTINGLABORATORYLTD.FCCID:2AXVDMW-0172 Thisreportshallnotbereproducedexceptinfull,withoutthewrittenapprovalofShenzhenLCSComplianceTestingLaboratoryLtd. Page1of2 ExternalPhotosoftheEUT Fig.1 Fig.2 SHENZHENLCSCOMPLIANCETESTINGLABORATORYLTD.FCCID:2AXVDMW-0172 Thisreportshallnotbereproducedexceptinfull,withoutthewrittenapprovalofShenzhenLCSComplianceTestingLaboratoryLtd. Page2of2 Fig.3 Fig.4 Antenna(5850MHz~5875MHz)

ID Label/Location Info

SHENZHENLCSCOMPLIANCETESTINGLABORATORYLTD.FCCID:2AXVDMW-0172 Thisreportshallnotbereproducedexceptinfull,withoutthewrittenapprovalofShenzhenLCSComplianceTestingLaboratoryLtd. Page 1 of1 LabelandLocation Size:L:0.15cm*W:0.15cm LabelandLocation FCCID:2AXVDMW-0172

Internal Photos

SHENZHENLCSCOMPLIANCETESTINGLABORATORYLTD.FCCID:2AXVDMW-0172 Thisreportshallnotbereproducedexceptinfull,withoutthewrittenapprovalofShenzhenLCSComplianceTestingLaboratoryLtd. Page1of1 InternalPhotosoftheEUT Fig.1 Fig.2

Test Report

SHENZHENLCSCOMPLIANCETESTINGLABORATORYLTD.FCCID:2AXVDMW-0172ReportNo.:LCS200828080AEA Thisreportshallnotbereproducedexceptinfull,withoutthewrittenapprovalofShenzhenLCSComplianceTestingLaboratoryLtd. Page1of30 FCCTESTREPORT FOR HuizhouYuanshengTechnologyCo.,Ltd Microwavesensormodule TestModel:MW-0172 Preparedfor:HuizhouYuanshengTechnologyCo.,Ltd Address: ZhongkaiHigh-techZoneson16th.HuiFengEastNo.2road,BuildingBRoom 516,518,Huizhoucity,GuangdongProvince,China Preparedby:ShenzhenLCSComplianceTestingLaboratoryLtd. Address: 101,201BldgA&301BldgC,JujiIndustrialParkShajingStreet,Baoan District,Shenzhen,China Tel:(+86)755-82591330 Fax:(+86)755-82591332 Web:www.LCS-cert.com Mail:[email protected] Dateofreceiptoftestsample:September26,2020 Numberoftestedsamples:1 DateofTest:September26,2020~October14,2020 DateofReport:October16,2020 SHENZHENLCSCOMPLIANCETESTINGLABORATORYLTD.FCCID:2AXVDMW-0172ReportNo.:LCS200828080AEA Thisreportshallnotbereproducedexceptinfull,withoutthewrittenapprovalofShenzhenLCSComplianceTestingLaboratoryLtd. Page2of30 FCCTESTREPORT FCCCFR47PART15C(15.249) ReportReferenceNo..........................:LCS200828080AEA DateofIssue.........................................:October16,2020 TestingLaboratoryName..................:ShenzhenLCSComplianceTestingLaboratoryLtd. Address.................................................: 101,201BldgA&301BldgC,JujiIndustrialParkShajingStreet,Baoan District,Shenzhen,China TestingLocation/Procedure................. : FullapplicationofHarmonisedstandardsā–  PartialapplicationofHarmonisedstandardsā–” Otherstandardtestingmethodā–” Applicant’sName................................:HuizhouYuanshengTechnologyCo.,Ltd Address.................................................: ZhongkaiHigh-techZoneson16th.HuiFengEastNo.2road,BuildingB Room516,518,Huizhoucity,GuangdongProvince,China TestSpecification Standard................................................:FCCCFR47PART15C(15.249)/ANSIC63.10:2013 TestReportFormNo............................:LCSEMC-1.0 TRFOriginator.....................................:ShenzhenLCSComplianceTestingLaboratoryLtd. MasterTRF...........................................:Dated2011-03 ShenzhenLCSComplianceTestingLaboratoryLtd.Allrightsreserved. Thispublicationmaybereproducedinwholeorinpartfornon-commercialpurposesaslongastheShenzhenLCS ComplianceTestingLaboratoryLtd.isacknowledgedascopyrightownerandsourceofthematerial.ShenzhenLCS ComplianceTestingLaboratoryLtd.takesnoresponsibilityforandwillnotassumeliabilityfordamagesresulting fromthereader'sinterpretationofthereproducedmaterialduetoitsplacementandcontext. TestItemDescription.........................:Microwavesensormodule TradeMark...........................................:/ TestModel............................................:MW-0172 Ratings..................................................: Input:7-12V~,<50mA Output:5V,>2mA Result....................................................: Positive Compiledby:Supervisedby:Approvedby: JackLiu/FileadministratorsJinWang/TechniqueprincipalGavinLiang/Manager SHENZHENLCSCOMPLIANCETESTINGLABORATORYLTD.FCCID:2AXVDMW-0172ReportNo.:LCS200828080AEA Thisreportshallnotbereproducedexceptinfull,withoutthewrittenapprovalofShenzhenLCSComplianceTestingLaboratoryLtd. Page3of30 FCC--TESTREPORT TestResultPositive Thetestreportmerelycorrespondstothetestsample. Itisnotpermittedtocopyextractsofthesetestresultwithoutthewrittenpermissionofthetestlaboratory. TestReportNo.:LCS200828080AEA October16,2020 Dateofissue TestModel..............................:MW-0172 EUT.........................................:Microwavesensormodule Applicant...............................:HuizhouYuanshengTechnologyCo.,Ltd Address..................................: ZhongkaiHigh-techZoneson16th.HuiFengEastNo.2road,BuildingB Room516,518,Huizhoucity,GuangdongProvince,China Telephone...............................:/ Fax..........................................:/ Manufacturer........................:HuizhouYuanshengTechnologyCo.,Ltd Address...................................: ZhongkaiHigh-techZoneson16th.HuiFengEastNo.2road,BuildingB Room516,518,Huizhoucity,GuangdongProvince,China Telephone...............................:/ Fax..........................................:/ Factory...................................:/ Address...................................:/ Telephone...............................:/ Fax..........................................:/ SHENZHENLCSCOMPLIANCETESTINGLABORATORYLTD.FCCID:2AXVDMW-0172ReportNo.:LCS200828080AEA Thisreportshallnotbereproducedexceptinfull,withoutthewrittenapprovalofShenzhenLCSComplianceTestingLaboratoryLtd. Page4of30 RevisionHistory RevisionIssueDateRevisionsRevisedBy 000October16,2020InitialIssueGavinLiang SHENZHENLCSCOMPLIANCETESTINGLABORATORYLTD.FCCID:2AXVDMW-0172ReportNo.:LCS200828080AEA Thisreportshallnotbereproducedexceptinfull,withoutthewrittenapprovalofShenzhenLCSComplianceTestingLaboratoryLtd. Page5of30 TABLEOFCONTENTS 1.GENERALINFORMATION.................................................................................................6 1.1DescriptionofDevice(EUT)...........................................................................................................6 1.2.SupportEquipmentList..................................................................................................................6 1.3.ExternalI/O.....................................................................................................................................6 1.4.DescriptionofTestFacility.............................................................................................................7 1.5.Statementofthemeasurementuncertainty.....................................................................................7 1.6.MeasurementUncertainty...............................................................................................................7 1.7.DescriptionofTestModes..........................................................................…

Text truncated - open the document above for the full version.

Test Setup Photos

SHENZHENLCSCOMPLIANCETESTINGLABORATORYLTD.FCCID:2AXVDMW-0172 _______________________________________________________________________________________________ Thisreportshallnotbereproducedexceptinfull,withoutthewrittenapprovalofShenzhenLCSComplianceTestingLaboratoryLtd. Page 1 of 2 TestSetupPhotosoftheEUT TestSetupPhoto(s)ofRadiatedEmissionsMeasurement Fig.1 Fig.2 SHENZHENLCSCOMPLIANCETESTINGLABORATORYLTD.FCCID:2AXVDMW-0172 _______________________________________________________________________________________________ Thisreportshallnotbereproducedexceptinfull,withoutthewrittenapprovalofShenzhenLCSComplianceTestingLaboratoryLtd. Page 2 of 2 ConductedEmission-ACadapterchargemode ConductedEmission

Contact Information

Applicant

Chun Hua Wu(Manager)
[email protected]086-752-3133399Fax: 086-752-3228395

Technical Contact

Huizhou Yuansheng Technology Co.,Ltd
[email protected]

China

Test Firm

Shenzhen LCS Compliance Testing Laboratory Ltd.Gavin Liang
[email protected]0755-82591330Fax: 0755-82591132

Technical Specifications

#Rule PartsFrequency RangePower Output
115C5.85 GHz - 5.88 GHz-
Modular Type
Limited Single Modular Approval
Confidentiality
Long Term
Grant Notes
Limited Single Modular Approval. OEM integrators must be provided with antenna installation instructions. The OEM integrators must be instructed to ensure that the end user has no manual instructions to remove or install the device.OEM integrators and end-users must be provided with transmitter operation conditions for satisfying RF exposure compliance. Only those antennas tested with the device or similar antennas with equal or lesser gain may be used with this transmitter.