WHITOP MeijiaIntelligentTech(Guangzhou)Co.,Ltd. Address:8,ShenshanAvenueEast,BaiyunDistrict,Guangzhou Hotline:400-020-1388 PostalCode:510460 Web:www.meijiazn.com WHITOP WHITOP OperatingInstructions SafetyPrecautions Pleasereadthisinformationcarefullybeforeuseandkeepitproperlyforfuture reference. Warning ★PreventionofAccidents Pleasestoretheproductoutsidethereachofchildrenandinfants.In addition,donotletthemtouchoroperatethisproduct. -Otherwise,accidentsorinjuriesmaybecausedbybeinginhaledintothe movingparts. Pleasehandlethepackagingbagofthisproductproperlytokeepitaway frominfants. -Otherwise,itmayleadtoaccidentssuchasasphyxiatoinfants. ★Powersupply Donotusewethandstoconnecttheadapterplugtothehouseholdpower outletorpulltheadapterplugoutofthehouseholdpoweroutlet. -Otherwise,itmaycauseelectricshockorinjury. Pleaseselecttheadapterorportablemobilepowersupplythatmeetsthe productrequirementstochargetheproduct. Donotuseadapterorotherpowersupplyequipment(5V/1A,USBinterface) thatdoesnotmeettherequirements,otherwisenormalchargingmaybe affected. Donotimmersethechargingstandinwaterorcleanitwithrunningwater. Donotputthechargingstandonornearthewater-filledsinkorbath. Ifthepowercordisdamagedortheconnectionwiththeadapterisloose, donotuseitagain. Donotdamagethepowercordorplug. Donotdamage,modify,bend,pull,twistortiethepowercordorplug.In addition,donotplaceheavyobjectsorsqueezethepowercord. -Otherwise,itmaycauseelectricshockorfireduetoshortcircuit. Donotexceedtheratedvalueofhouseholdpowersocketorwiringduring use. -Iftoomanyplugsareconnectedtoahouseholdpoweroutlettomakeitexceed theratedvalue,itmaycausefireduetooverheating. Whencleaningthechargingstand,besuretounplugtheadapterfromthe householdpoweroutletortheUSBplugfromotherportablemobilepower supply. -Otherwise,itmaycauseelectricshockorinjury. ★Incaseofabnormalityorfailure Incaseofabnormalityorfailure,stopusingimmediatelyandunplugtheadapter plugorUSBinterface. -Otherwise,itmaycausefire,electricshockorinjury. <abnormalityorfailure> Theunit,adapterorpowercordisdeformedorabnormallyheated. Theunit,adapterorpowercordsmellsofburning. Theunit,adapterorpowercordmakesabnormalsoundduringuseor charging. -Pleasecontactcustomerservicecenterimmediately. ★Thetoothbrush Thisproductcontainsabuilt-inrechargeablebattery.Donotputthe productintothefire,heat,orcharge,useorplaceitathightemperature, anddonotimpactorknocktheproduct. -Otherwise,itwillcauseoverheating,fireorexplosion. Donotmodifyorrepairthisproduct. -Otherwise,itmaycauseelectricshock,injuryorfire. Pleasecontactthecustomerservicecenter. Donotdisassembletheproductexceptwhenitisdiscarded. -Otherwise,itmaycauseelectricshock,injuryorfire. ★Inaddition,pleasepayattentiontothemattersbelow: Thisproductshouldnotbeusedbythosewithphysical,sensoryormental disabilities,orthosewholackexperienceandknowledge(including children).Aguardianmustsuperviseandguidetheuseofthisproduct,and beresponsibleforthesafetyofusers,andtakecareofchildrentoensure thattheywillnotplaywiththisproduct. -Otherwise,itmayleadtoaccidentsorinjury. Thechargingstandcannotbereplaced.Ifthechargingstandisdamaged,it shouldbediscardedandreplacedwiththeoriginalchargingstand. -Otherwise,itmayleadtoaccidentsorinjury. Caution Pleaseconsultyourdentistbeforeusingthisproductifyouhavehadoralor gingivalsurgeryintheprevious2months. Thosewithsevereperiodontaldisease,teethundertreatmentorthosewho worriedaboutdiscomfortinthemouthshouldconsultadentistbeforeuse. Pleaseconsultyourdentistifyourgumsbleedheavilyafterusingthis productoriftheystillbleedafter1weekofuse. Pleasealsoconsultyourdentistifyoufeeluncomfortableorpainfulwhen usingthisproduct. TheWHITOPtoothbrushmeetsthesafetystandardofelectromagnetic device.Foranyquestionsaboutpacemakersorotherimplanteddevices, pleaseconsultyourdoctororthedevicemanufactureroftheimplanted devicebeforeuse. ★Precautions Donotwrapthepowercordaroundthechargerwhencharging. -Otherwise,itmaycausethepowercordtobedisconnectedandmaycause electricshockorfirecausedbyshortcircuit. Pleasedisconnecttheproductfromthepowersupplyinadditiontothe timewhentheproductischarged. -Otherwise,itmayleadtoleakageduetothedeclineofinsulationperformance, whichmayleadtoelectricshockorfire. Holdtheadapterpluginsteadofjustthepowercordwhenpullingoutthe adapter. -Otherwise,itmaycauseelectricshockorfireduetoshortcircuit. ★Instructionsforuse Donotusepaintthinner,gasoline,alcoholorotherchemicalstocleantheproduct. Otherwise,itmaycausetheproducttocrackorfade.Useasoftclothslightlydippedin tapwaterorsoapywatertocleanthecover. Afteruse,theproductshouldbeplacedfarawayfromthepool,bathroomorother areasexposedtowaterormoisture,andavoidbeingplacedunderhightemperature ordirectsunlight. ProductIntroduction 1 Toothbrush shaftprotective cover 2 Toothbrush head 3 Unit 4 On/offswitch 5 Hiddenbrushmode indicator 6 Breathingcharging indicator 7 Brushheadcover 8 Chargingstand/USB cable Note:theitemsintheboxmayvaryaccording tothemodelpurchased. Charging Whenbrushingteethnormally,the redlightofthechargingindicator flashes,indicatingthatthepowerof theproductislowandreminding thatitneedstobecharged; Wirelesschargingmodel(with chargingstand):connecttheadapter, plugintheexternalsocket,orUSB interfacedirectlyconnecttothe portablemobilepowersupply,and putthefrontoftheunitstraight forwardonthechargingstand; TYPE-Cdirect-chargingmodel (withUSBcable):plugintheUSB cable,connecttheadapter,pluginthe externalsocket,orconnecttheUSB interfacedirectlytotheportable mobilepowersupply; Pleaserefertotheattachedtablefor thechargingtimeofspecificmodels. Intheprocessofcharging,the powerindicatorchangesfrom flashinginredtogreenlight, indicatingthatthebatteryisfull. WirelesschargingTYPE-Cdirect-charging HowToUse 1.Installthetoothbrushheadcorrectlyonthe toothbrushheadshaft. Alignthefrontoftheunitwiththefrontofthe toothbrushhead.Pressthetoothbrushheaddownon themetalshaftwithproperforceuntilitcannotbe pressed. Thereisasmallgap(about1mm)betweenthe toothbrushheadandtheunit,whichisanecessary gap,notafailure. 2.Wetthebristlesandapplysmallamount…
Text truncated - open the document above for the full version.
GUANGZHOUMEIJIAINTELLIGENT TECHNOLOGYCO.,LTD AgentAuthorization Company:GUANGZHOUMEIJIAINTELLIGENTTECHNOLOGYCO.,LTD Address:NO.8building7ShenshanEastRoadBaiyunDistrict,Guangzhou,P.R.C ProductName:Inductioncharger TradeMark:WHITOP ModelNumber(s):B FCCID:2AXVR-CD-B WeauthorizeMiCOMLabsInc.,575BoulderCourt,Pleasanton,California94566,USA, toactonourbehalfonallmattersconcerningthecertificationofabovenamed equipment. WedeclarethatMiCOMLabsInc.isallowedtoforwardallinformationrelatedtothe approvalandcertificationofequipmenttotheregulatoryagenciesasrequiredandto discussanyissuesconcerningtheapprovalapplication.Anyandallactscarriedoutby MiCOMLabsonourbehalfshallhavethesameeffectasactsofourown. Signature:Date:2021-06-25 Name:QiaomeiYe Title:Metrologybranch Company:GUANGZHOUMEIJIAINTELLIGENTTECHNOLOGYCO.,LTD
GUANGZHOUMEIJIAINTELLIGENTTECHNOLOGYCO.,LTD OfficeofEngineeringTechnology FederalCommunicationsCommission 7435OaklandMillsRoad Columbia,MD21046 USA Date:2021-06-25 Subject;RequestforConfidentiality FCCID:2AXVR-CD-B ToWhomItMayConcern, PursuanttotheprovisionsoftheCommission’srulesTitle47Sections§0.457and§0.459,we arerequestingtheCommissiontowithholdthefollowingattachment(s)asconfidential documentsfrompublicdisclosureindefinitely. Thesedocumentscontaindetailedsystemandequipmentdescriptionsandareconsideredas proprietaryinformationinoperationoftheequipment.Thepublicdisclosureofthesedocuments mightbeharmfultoourcompanyandwouldgivecompetitorsanunfairadvantageinthemarket. SchematicDiagram BlockDiagram PartsList OperationalDescription Tune-upProcedure Inadditionaltoabovementioneddocuments,inordertocomplywiththemarketingregulations inTitle47CFR§2.803andtheimportationrulesinTitle47CFR§2.1204,whileensuringthat businesssensitiveinformationremainsconfidentialuntiltheactualmarketingofnewly authorizeddevices,werequestShortTermConfidentialityofthefollowingattachment(s); ExternalPhotos TestSetupPhotos InternalPhotos UserManual For45days,pursuanttoPublicNoticeDA04-1705. OR For180dayspursuanttoKDB726920D01. Itisourunderstandingthatallmeasurementtestreports,FCCIDlabelformatand correspondenceduringthecertificationreviewprocesscannotbegrantedasconfidential documentsandthisinformationwillbeavailableforpublicreviewoncethegrantofequipment authorizationisissued. Sincerely, Signature: Name:QiaomeiYe Title:Metrologybranch
SHENZHENLCSCOMPLIANCETESTINGLABORATORYLTD.FCCID:2AXVR-CD-B Thisreportshallnotbereproducedexceptinfull,withoutthewrittenapprovalofShenzhenLCSComplianceTestingLaboratoryLtd. Page1of7 ExternalPhotosoftheEUT Fig.1 Fig.2 SHENZHENLCSCOMPLIANCETESTINGLABORATORYLTD.FCCID:2AXVR-CD-B Thisreportshallnotbereproducedexceptinfull,withoutthewrittenapprovalofShenzhenLCSComplianceTestingLaboratoryLtd. Page2of7 Fig.3 Fig.4 SHENZHENLCSCOMPLIANCETESTINGLABORATORYLTD.FCCID:2AXVR-CD-B Thisreportshallnotbereproducedexceptinfull,withoutthewrittenapprovalofShenzhenLCSComplianceTestingLaboratoryLtd. Page3of7 Fig.5 Fig.6 SHENZHENLCSCOMPLIANCETESTINGLABORATORYLTD.FCCID:2AXVR-CD-B Thisreportshallnotbereproducedexceptinfull,withoutthewrittenapprovalofShenzhenLCSComplianceTestingLaboratoryLtd. Page4of7 Fig.7 Fig.8 SHENZHENLCSCOMPLIANCETESTINGLABORATORYLTD.FCCID:2AXVR-CD-B Thisreportshallnotbereproducedexceptinfull,withoutthewrittenapprovalofShenzhenLCSComplianceTestingLaboratoryLtd. Page5of7 Fig.9 Fig.10 SHENZHENLCSCOMPLIANCETESTINGLABORATORYLTD.FCCID:2AXVR-CD-B Thisreportshallnotbereproducedexceptinfull,withoutthewrittenapprovalofShenzhenLCSComplianceTestingLaboratoryLtd. Page6of7 Fig.11 Fig.12 SHENZHENLCSCOMPLIANCETESTINGLABORATORYLTD.FCCID:2AXVR-CD-B Thisreportshallnotbereproducedexceptinfull,withoutthewrittenapprovalofShenzhenLCSComplianceTestingLaboratoryLtd. Page7of7 Fig.13 Fig.14
SHENZHENLCSCOMPLIANCETESTINGLABORATORYLTD.FCCID:2AXVR-CD-B Thisreportshallnotbereproducedexceptinfull,withoutthewrittenapprovalofShenzhenLCSComplianceTestingLaboratoryLtd. Page 1 of1 LabelandLocation Size:L:1.5cm*W:1.5cm LabelLocation
SHENZHENLCSCOMPLIANCETESTINGLABORATORYLTD.FCCID:2AXVR-CD-B Thisreportshallnotbereproducedexceptinfull,withoutthewrittenapprovalofShenzhenLCSComplianceTestingLaboratoryLtd. Page1of4 InternalPhotosoftheEUT Fig.1 Fig.2 CoilAntenna SHENZHENLCSCOMPLIANCETESTINGLABORATORYLTD.FCCID:2AXVR-CD-B Thisreportshallnotbereproducedexceptinfull,withoutthewrittenapprovalofShenzhenLCSComplianceTestingLaboratoryLtd. Page2of4 Fig.3 Fig.4 SHENZHENLCSCOMPLIANCETESTINGLABORATORYLTD.FCCID:2AXVR-CD-B Thisreportshallnotbereproducedexceptinfull,withoutthewrittenapprovalofShenzhenLCSComplianceTestingLaboratoryLtd. Page3of4 Fig.5 Fig.6 SHENZHENLCSCOMPLIANCETESTINGLABORATORYLTD.FCCID:2AXVR-CD-B Thisreportshallnotbereproducedexceptinfull,withoutthewrittenapprovalofShenzhenLCSComplianceTestingLaboratoryLtd. Page4of4 Fig.7
SHENZHENLCSCOMPLIANCETESTINGLABORATORYLTD.FCCID:2AXVR-CD-B ___________________________________________________________________________ Thisreportshallnotbereproducedexceptinfull,withoutthewrittenapprovalofShenzhenLCSComplianceTestingLaboratoryLtd. Page 1 of 11 RFExposureEvaluationReport 1.ProductInformation FCCID:2AXVR-CD-B ProductNameInductioncharger ModelNumberB PowerSupply5V,5W MaximumRatedPowerofWPT5W ModulationTypeContinuousWave FrequencyRange110.0-205KHz OperationFrequency125.0KHz AntennaTypeCoilAntenna Hardwareversion AHX-9102-TX-V0.21 Softwareversion JDS9102A/SOP-14 ExposurecategoryGeneralpopulation/uncontrolledenvironment EUTTypeProductionUnit DeviceTypeMobileDevice 2.EvaluationMethod PerKDB680106D01Section3.RFExposureRequirements; 1)ConsumerwirelesspowertransferdevicesapprovedunderPart18insome caseshavetodemonstratecompliancewithRFexposurerequirements.Thepotentialforexposure mustbeassessedaccordingtotheoperatingconfigurationsofthewirelesssystemandtheexposure conditionsofusersandbystanders.RFexposuremustbeevaluatedwiththeclientdevice(s)being chargedbytheprimaryatmaximumoutputpower.TheRFexposurerequirementsmustbe determinedinconjunctionwiththedeviceoperatingcharacteristics,accordingtothemobileand portableexposurerequirementsinSection2.1091andSection2.1093oftherules.SARandMPElimits donotcoverthefrequencyrangeforwirelesspowertransferapplicationswhichoperatebelow100 kHzand300kHzrespectively;therefore,RFexposurecomplianceneedstobedeterminedwithrespect to1.1307(c)and(d)oftheFCCrules. 2)Basedonthedesignandimplementationofthepowertransferapplication, itmustbeclearlyidentifiedifmobileorportableRFexposureconditionsapply.Devicesthatare installedtoprovideseparationofatleast20cmfromusersandbystandersmayqualifyformobile exposureconditions.Forsomeconditionswhereusersandbystandersmaybeexposedatcloserthan 20cm,section2.1091(d)(4)oftherulesmayapply. 3)Fordevicesdesignedfortypicaldesktopapplications,suchawireless chargingpads,RFexposureevaluationshouldbeconductedassumingauserseparationdistanceof15 cm.EandHfieldstrengthmeasurementsornumericalmodelingmaybeusedtodemonstrate compliance.Measurementsshouldbemadefromallsidesandthetopoftheprimary/clientpair,with the15cmmeasuredfromthecenteroftheprobe(s)totheedgeofthedevice.Emissionsbetween100 kHzto300kHzshouldbeassessedversusthelimitsat300kHzinTable1ofSection1.1310:614V/m and1.63A/m.AKDBinquiryisrequiredtodeterminetheapplicableexposurelimitsbelow100kHz. 4)Portableexposureconditionsfrom100kHzto6GHzaredeterminedwith respecttoSARrequirements.ExistingSARsystemsandtestproceduresaregenerallyintendedfor measurementsabove100MHz.Whilenumericalmodelingcanbeanalternative,theconstraintsof SHENZHENLCSCOMPLIANCETESTINGLABORATORYLTD.FCCID:2AXVR-CD-B ___________________________________________________________________________ Thisreportshallnotbereproducedexceptinfull,withoutthewrittenapprovalofShenzhenLCSComplianceTestingLaboratoryLtd. Page 2 of 11 substantialcomputationalresourcesatlowfrequenciescouldintroducefurtherlimitations.Under thesecircumstances,includingoperationsbelow100kHz,theCommissionmayconsideracombination ofanalyticalanalysis,fieldstrength,radiatedandconductedpowermeasurements,inconjunctionwith somelimitednumericalmodelingtoassesscompliance. 5)Dependingontheoperatingfrequency,existingSARandMPEmeasurement proceduresmaybeadaptedtoevaluatewirelesspowertransferdevicesforcompliancewithrespectto mobileorportableexposureconditions.IfthegranteeoritstestlabhaveanyquestionsregardingRF exposureevaluationtheyshouldcontacttheFCCLaboratorywithsufficientsystemoperating configurationdetailstodetermineifRFexposureevaluationisnecessaryand,ifrequired,howtoapply specifictestprocedures.Below100MHz,whenSARtestingisrequiredandthedeviceisoperatingat closeproximitytopersons,informationondevicedesign,implementation,operatingconfigurations, exposureconditionsofusersandbystandersareneededtodeterminetheevaluationandtesting requirements.Inaddition,theinfluenceofnearbyobjectsmayalsoneedconsiderationaccordingto thewirelesspowertransfersystemimplementation;forexample,theeffectsofplacingthedevice,its coilsorradiatingelementsonornearmetallicsurfaces 6)AccordingtoApril2018TCBWorkshop,NoneedtoreportE-field measurements.OnlyH-fieldrequired. 3.EvaluationLimit 3.1ReferEvaluationMethod ANSIC95.1–1999:IEEEStandardforSafetyLevelswithRespecttoHumanExposuretoRadioFrequency ElectromagneticFields,3kHzto300GHz. FCCKDBpublication680106D01RFExposureWirelessChargingAppsv03:RFExposureConsiderations forLowPowerConsumerWirelessPowerTransferApplications FCCCFR47part11.1310:Radiofrequencyradiationexposurelimits. FCCCFR47part22.1091:Radiofrequencyradiationexposureevaluation:mobiledevices FCCCFR47part18.107:Indusial,Scientific,andMedicalEquipment 3.2Limit LimitsforMaximumPermissibleExposure(MPE)/ControlledExposure Frequency Range(MHz) ElectricField Strength(V/m) MagneticField Strength(A/m) PowerDensity (mW/cm²) AveragingTime (minute) LimitsforOccupational/ControlledExposure 0.3-3.06141.63*1006 3.0-301842/f4.89/f*900/f 2 6 30-30061.40.1631.06 300-1,500//f/3006 1,500-100,000//56 SHENZHENLCSCOMPLIANCETESTINGLABORATORYLTD.FCCID:2AXVR-CD-B ___________________________________________________________________________ Thisreportshallnotbereproducedexceptinfull,withoutthewrittenapprovalofShenzhenLCSComplianceTestingLaboratoryLtd. Page 3 of 11 LimitsforMaximumPermissibleExposure(MPE)/UncontrolledExposure Frequency Range(MHz) ElectricField Strength(V/m) MagneticField Strength(A/m) PowerDensity (mW/cm²) AveragingTime (minute) LimitsforGeneralPopulation/UncontrolledExposure 0.3-1.346141.63*10030 1.34-30824/f2.19/f*180/f 2 30 30-30027.50.0730.230 300-1,500//f/150030 1,500-100,000//1.030 F=frequencyinMHz *=Plane-waveequivalentpowerdensity AccordingtoFCCKDB680106D01Section3.RFExposureRequirementsclause3theEmission-Limits inthefrequencyrangefrom100KHzto300KHzshouldbeassessedversusthelimitsat300KHzin Table1ofCFR47–Section1.310asfollowing(measureddistanceshallbe15cmfromthecenterof theprobetotheedgeofthedevice): E-Field*/*B-Field Fre…
Text truncated - open the document above for the full version.
SHENZHENLCSCOMPLIANCETESTINGLABORATORYLTD.FCCID:2AXVR-CD-BReportNo.:LCS200926017AEA Thisreportshallnotbereproducedexceptinfull,withoutthewrittenapprovalofShenzhenLCSComplianceTestingLaboratoryLtd. Page1of21 FCCTESTREPORT For GUANGZHOUMEIJIAINTELLIGENTTECHNOLOGYCO.,LTD Inductioncharger TestModel:B Preparedfor: GUANGZHOUMEIJIAINTELLIGENTTECHNOLOGYCO., LTD Address: NO.8building7ShenshanEastRoadBaiyunDistrict, Guangzhou,P.R.C Preparedby:ShenzhenLCSComplianceTestingLaboratoryLtd. Address: 101,201BldgA&301BldgC,JujiIndustrialParkShajing Street,BaoanDistrict,Shenzhen,China Tel:(+86)755-82591330 Fax:(+86)755-82591332 Web:www.LCS-cert.com Mail:[email protected] Dateofreceiptoftestsample:September27,2020 Numberoftestedsamples:1 Serialnumber:Prototype DateofTest:September27,2020~October10,2020 DateofReport:October14,2020 SHENZHENLCSCOMPLIANCETESTINGLABORATORYLTD.FCCID:2AXVR-CD-BReportNo.:LCS200926017AEA Thisreportshallnotbereproducedexceptinfull,withoutthewrittenapprovalofShenzhenLCSComplianceTestingLaboratoryLtd. Page2of21 FCCTESTREPORT FCCCFR47PART18 ReportReferenceNo......................:LCS200926017AEA DateOfIssue......................................:October14,2020 TestingLaboratoryName..............:ShenzhenLCSComplianceTestingLaboratoryLtd. Address................................................: 101,201BldgA&301BldgC,JujiIndustrialParkShajingStreet, BaoanDistrict,Shenzhen,China TestingLocation/Procedure............ : FullapplicationofHarmonisedstandards■PartialapplicationofHarmonisedstandards□ Otherstandardtestingmethod□ Applicant’sName.............................:GUANGZHOUMEIJIAINTELLIGENTTECHNOLOGYCO.,LTD Address................................................: NO.8building7ShenshanEastRoadBaiyunDistrict,Guangzhou, P.R.C TestSpecification Standard..............................................:FCCCFR47PART18 TestReportFormNo.........................:LCSEMC-1.0 TRFOriginator....................................:ShenzhenLCSComplianceTestingLaboratoryLtd. MasterTRF.........................................:Dated2011-03 ShenzhenLCSComplianceTestingLaboratoryLtd.Allrightsreserved. Thispublicationmaybereproducedinwholeorinpartfornon-commercialpurposesaslongasthe ShenzhenLCSComplianceTestingLaboratoryLtd.isacknowledgedascopyrightownerandsourceof thematerial.ShenzhenLCSComplianceTestingLaboratoryLtd.takesnoresponsibilityforandwillnot assumeliabilityfordamagesresultingfromthereader'sinterpretationofthereproducedmaterialdueto itsplacementandcontext. TestItemDescription.....................:Inductioncharger TradeMark..........................................:WHITOP TestModel...........................................:B PowerSupply......................................: 5V,5W Result..................................................: Positive Compiledby:Supervisedby:Approvedby: JackLiu/AdministratorsJinWang/TechniqueprincipalGavinLiang/Manager SHENZHENLCSCOMPLIANCETESTINGLABORATORYLTD.FCCID:2AXVR-CD-BReportNo.:LCS200926017AEA Thisreportshallnotbereproducedexceptinfull,withoutthewrittenapprovalofShenzhenLCSComplianceTestingLaboratoryLtd. Page3of21 FCCTESTREPORT TestResultPositive Thetestreportmerelycorrespondstothetestsample. Itisnotpermittedtocopyextractsofthesetestresultwithoutthewrittenpermissionofthetest laboratory. TestReportNo.:LCS200926017AEA October14,2020 Dateofissue TestModel..............................:B EUT.........................................:Inductioncharger Applicant...............................:GUANGZHOUMEIJIAINTELLIGENTTECHNOLOGYCO.,LTD Address..................................: NO.8building7ShenshanEastRoadBaiyunDistrict,Guangzhou, P.R.C Telephone...............................:/ Fax..........................................:/ Manufacturer........................:GUANGZHOUMEIJIAINTELLIGENTTECHNOLOGYCO.,LTD Address...................................: NO.8building7ShenshanEastRoadBaiyunDistrict,Guangzhou, P.R.C Telephone...............................:/ Fax..........................................:/ Factory...................................:GUANGZHOUMEIJIAINTELLIGENTTECHNOLOGYCO.,LTD Address...................................: NO.8building7ShenshanEastRoadBaiyunDistrict,Guangzhou, P.R.C Telephone...............................:/ Fax..........................................:/ SHENZHENLCSCOMPLIANCETESTINGLABORATORYLTD.FCCID:2AXVR-CD-BReportNo.:LCS200926017AEA Thisreportshallnotbereproducedexceptinfull,withoutthewrittenapprovalofShenzhenLCSComplianceTestingLaboratoryLtd. Page4of21 RevisionHistory RevisionIssueDateRevisionsRevisedBy 000October14,2020InitialIssueGavinLiang SHENZHENLCSCOMPLIANCETESTINGLABORATORYLTD.FCCID:2AXVR-CD-BReportNo.:LCS200926017AEA Thisreportshallnotbereproducedexceptinfull,withoutthewrittenapprovalofShenzhenLCSComplianceTestingLaboratoryLtd. Page5of21 TABLEOFCONTENTS 1.GENERALINFORMATION ............................................................................................... 6 1.1DescriptionofDevice(EUT) ..................................................................................................... 6 1.2SupportequipmentList ............................................................................................................. 6 1.3ExternalI/OCable ...................................................................................................................... 6 1.4DescriptionofTestFacility ........................................................................................................ 7 1.5StatementoftheMeasurementUncertainty .......................................................................... 7 1.6MeasurementUncertainty ......................................................................................................... 7 1.7DescriptionofTestModes ........................................................................................................ 8 2.TESTMETHODOLOGY ..................................................................................................... 9 2.1EUTConfiguration .................…
Text truncated - open the document above for the full version.
SHENZHENLCSCOMPLIANCETESTINGLABORATORYLTD.FCCID:2AXVR-CD-B _______________________________________________________________________________________________ Thisreportshallnotbereproducedexceptinfull,withoutthewrittenapprovalofShenzhenLCSComplianceTestingLaboratoryLtd. Page 1 of 1 AppendixA PhotographsofTestSetup ConductedEmission-ACadapterchargemode RadiatedEmissionbelow30MHz-DCadapterchargemode
| # | Rule Parts | Frequency Range | Power Output |
|---|---|---|---|
| 1 | 18 | 0.11 MHz - 0.205 MHz | - |