the user's authority to operate this equipment FCC Caution: Any changes or modifications not expressly approved by the party responsible for compliance could void Such modifications could void the user's authority to operate the equipment. 66 Studios Co., Ltd is not responsible for any changes or modifications not expressly approved by 66 Studios Co., Ltd. compromettre le fonctionnement." l'utilisateur de l'appareil doit accepter tout brouillage radioélectrique subi, même si le brouillage est susceptible d'en L'exploitation est autorisée aux deux conditions suivantes : (1) l'appareil ne doit pas produire de brouillage, et (2) “Le présent appareil est conforme aux CNR d'Industrie Canada applicables aux appareils radio exempts de licence. interference that may cause undesired operation of the device. conditions: (1) this device may not cause interference, and (2) this device must accept any interference, including This device complies with Industry Canada license-exempt RSS standard (s). Operation is subject to the following two Industry Canada (IC) Compliance Statement for Canada contrôlé. Cet équipement est conforme aux limites d'exposition aux radiations de la IC définies pour un environnement non This equipment complies with FCC radiation exposure limits set forth for an uncontrolled environment. — Consult the dealer or an experienced radio/TV technician for help. — Connect the equipment into an outlet on a circuit dierent from that to which the receiver is connected. — Increase the separation between the equipment and receiver. — Reorient or relocate the receiving antenna. try to correct the interference by one or more of the following measures: to radio or television reception, which can be determined by turning the equipment o and on, the user is encouraged to guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference accordance with the instructions, may cause harmful interference to radio communications. However, there is no installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of NOTE that may cause undesired operation. may not cause harmful interference, and (2) this device must accept any interference received, including interference This device complies with part 15 of the FCC rules. Operation is subject to the following two conditions: (1) This device Federal Communications Commission (FCC) Compliance Statement for USA EnigmaBot CAN ICES-3 (B)/NMB-3(B). IC: 26754-RS0001 FCC ID: 2AYDL-RS0001 Model: EnigmaBot-E1
Report No.: 2011RSU059-UE 1 of 3 EUT External Photograph (1) EUT Photo (2) EUT Photo Report No.: 2011RSU059-UE 2 of 3 (3) EUT Photo (4) EUT Photo Report No.: 2011RSU059-UE 3 of 3 (5) EUT Photo (6) EUT Photo
Report No.: 2011RSU059-UE 1 of 5 EUT Internal Photograph (1) EUT Photo (2) EUT Photo Report No.: 2011RSU059-UE 2 of 5 (3) EUT Photo (4) EUT Photo Report No.: 2011RSU059-UE 3 of 5 (5) EUT Photo (6) EUT Photo Report No.: 2011RSU059-UE 4 of 5 (7) EUT Photo (8) EUT Photo Report No.: 2011RSU059-UE 5 of 5 (9) EUT Photo
MRT Technology (Suzhou) Co., Ltd Report No.: 2011RSU059-U2 Phone: +86-512-66308358 Report Version: V01 Web: www.mrt-cert.com Issue Date: 03-02-2021 1 of 9 RF Exposure Evaluation Declaration FCC ID: 2AYDL-RS0001 Applicant: 66 Studios Co., Ltd Application Type: Certification Product: EnigmaBot Model No.: EnigmaBot-E1 FCC Rule(s): FCC Part 2.1093 KDB 447498 D01 General RF Exposure Guidance v06 Reviewed By: Vincent Yu Approved By: Robin Wu The test results relate only to the samples tested. The test results shown in the test report are traceable to the national/international standards through the calibration of the equipment and evaluated measurement uncertainty herein. The test report shall not be reproduced except in full without the written approval of MRT Technology (Suzhou) Co., Ltd. Report No.: 2011RSU059-U2 2 of 9 Revision History Report No. Version Description Issue Date Note 2011RSU059-U2 Rev. 01 Initial Report 03-02-2021 Valid Report No.: 2011RSU059-U2 3 of 9 CONTENTS Description Page 1. General Information ................................................................................................... 4 1.1. Applicant ................................................................................................................... 4 1.2. Manufacturer ............................................................................................................ 4 1.3. Testing Facility ......................................................................................................... 4 2. Product Information ................................................................................................... 5 2.1. Equipment Description ........................................................................................... 5 2.2. Product Specification Subjective to this report ................................................... 5 2.3. Working Frequencies for this report ..................................................................... 5 3. RF Exposure Evaluation ............................................................................................ 6 3.1. Limits ......................................................................................................................... 6 3.2. Test Procedure ......................................................................................................... 7 3.3. Test Result of RF Exposure Evaluation ............................................................... 8 Appendix - EUT Photograph ............................................................................................. 9 Report No.: 2011RSU059-U2 4 of 9 1. General Information 1.1. Applicant 66 Studios Co., Ltd Room 301C, C-2 Bldg., No. 66, Xixiaokou Rd, Haidian Dist., Beijing, China. 1.2. Manufacturer 66 Studios Co., Ltd Room 301C, C-2 Bldg., No. 66, Xixiaokou Rd, Haidian Dist., Beijing, China. 1.3. Testing Facility Test Site – MRT Suzhou Laboratory Laboratory Location (Suzhou - Wuzhong) D8 Building, No.2 Tian’edang Rd., Wuzhong Economic Development Zone, Suzhou, China Laboratory Location (Suzhou - SIP) 4b Building, Liando U Valley, No.200 Xingpu Rd., Shengpu Town, Suzhou Industrial Park, China Laboratory Accreditations A2LA: 3628.01 CNAS: L10551 FCC: CN1166 ISED: CN0001 VCCI: R-20025, G-20034, C-20020, T-20020 Test Site – MRT Shenzhen Laboratory Laboratory Location (Shenzhen) 1G, Building A, Junxiangda Building, Zhongshanyuan Road West, Nanshan District, Shenzhen, China Laboratory Accreditations A2LA: 3628.02 CNAS: L10551 FCC: CN1284 ISED: CN0105 Test Site – MRT Taiwan Laboratory Laboratory Location (Taiwan) No. 38, Fuxing 2nd Rd., Guishan Dist., Taoyuan City 333, Taiwan (R.O.C.) Laboratory Accreditations TAF: L3261-190725 FCC: 291082, TW3261 ISED: TW3261 Report No.: 2011RSU059-U2 5 of 9 2. Product Information 2.1. Equipment Description 2.2. Product Specification Subjective to this report Note: Above information is declared by manufacturer. 2.3. Working Frequencies for this report Channel Frequency Channel Frequency Channel Frequency 00 2402 MHz 01 2404 MHz 02 2406 MHz 03 2408 MHz 04 2410 MHz 05 2412 MHz 06 2414 MHz 07 2416 MHz 08 2418 MHz 09 2420 MHz 10 2422 MHz 11 2424 MHz 12 2426 MHz 13 2428 MHz 14 2430 MHz 15 2432 MHz 16 2434 MHz 17 2436 MHz 18 2438 MHz 19 2440 MHz 20 2442 MHz 21 2444 MHz 22 2446 MHz 23 2448 MHz 24 2450 MHz 25 2452 MHz 26 2454 MHz 27 2456 MHz 28 2458 MHz 29 2460 MHz 30 2462 MHz 31 2464 MHz 32 2466 MHz 33 2468 MHz 34 2470 MHz 35 2472 MHz 36 2474 MHz 37 2476 MHz 38 2478 MHz 39 2480 MHz -- -- -- -- Product Name EnigmaBot Model No. EnigmaBot-E1 HVIN EnigmaBot-E1 PMN EnigmaBot-E1 Sample ID 20201123Sample#07 (Conducted) 20201123Sample#10 (Radiated) Frequency Range 2402 ~ 2480MHz Bluetooth Specification v5.1 (BLE Only) Data Rate 1Mbps Modulation GFSK Antenna Type Chip Antenna Antenna Gain 0.44dBi Report No.: 2011RSU059-U2 6 of 9 3. RF Exposure Evaluation 3.1. Limits SAR Test Exclusion Thresholds for 100 MHz – 6 GHz and ≤ 50 mm Approximate SAR Test Exclusion Power Thresholds at Selected Frequencies and Test Separation Distances are illustrated in the following Table. The equation and threshold in Note 1 must be applied to determine SAR test exclusion. MHz 5 10 15 20 25 mm 150 39 77 116 155 194 SAR Test Exclusion Threshold (mW) 300 27 55 82 110 137 450 22 45 67 89 112 835 16 33 49 66 82 900 16 32 47 63 79 1500 12 24 37 49 61 1900 11 22 33 44 54 2450 10 19 29 38 48 3600 8 16 24 32 40 5200 7 13 20 26 33 5400 6 13 19 26 32 5800 6 12 19 25 31 MHz 30 35 40 45 50 mm 150 232 271 310 349 387 SAR Test Exclusion Threshold (mW) 300 164 192 219 246 274 450 134 157 179 201 224 835 98 115 131 148 164 900 95 111 126 142 158 1500 73 86 98 110 122 1900 65 76 87 98 109 2450 57 67 77 86 96 3600 47 55 63 71 79 5200 39 46 53 59 66 5400 39 45 52 58 65 5800 37 44 50 56 62 Report No.: 2011RSU059-U2 7 of 9 Note: The 1-g and 10-g SAR test exclusion thresholds for 100 MHz to 6 GHz at test separation distances ≤ 50 mm are determined by: [(max. power of channel, inc…
Text truncated - open the document above for the full version.
MRT Technology (Suzhou) Co., Ltd Report No.: 2011RSU059-U1 Phone: +86-512-66308358 Report Version: V01 Web: www.mrt-cert.com Issue Date: 03-02-2021 1 of 55 FCC ID: 2AYDL-RS0001 IC: 26754-RS0001 Applicant: 66 Studios Co., Ltd Application Type: Certification Product: EnigmaBot Model No.: EnigmaBot-E1 FCC Classification: Digital Transmission System (DTS) FCC Rule Part(s): Part 15 Subpart C (Section 15.247) ISED Rule Part(s): RSS-247 Issue 2, RSS-GEN Issue 5 Test Procedure(s): ANSI C63.10-2013 Test Date: November 26 ~ December 26, 2020 Reviewed By: Vincent Yu Approved By: Robin Wu MEASUREMENT REPORT FCC PART 15.247 / RSS-247 Bluetooth LE The test results relate only to the samples tested. This equipment has been shown to be capable of compliance with the applicable technical standards as indicated in the measurement report and was tested in accordance with the measurement procedures specified in ANSI C63.10-2013. Test results reported herein relate only to the item(s) tested. The test report shall not be reproduced except in full without the written approval of MRT Technology (Suzhou) Co., Ltd. Report No.: 2011RSU059-U1 2 of 55 Revision History Report No. Version Description Issue Date Note 2011RSU059-U1 Rev. 01 Initial Report 03-02-2021 Valid Report No.: 2011RSU059-U1 3 of 55 CONTENTS Description Page 1. GENERAL INFORMATION ........................................................................................................ 5 1.1. Applicant .......................................................................................................................... 5 1.2. Manufacturer ................................................................................................................... 5 1.3. Testing Facility ................................................................................................................ 5 2. PRODUCT INFORMATION ........................................................................................................ 6 2.1. Feature of Equipment under Test .................................................................................... 6 2.2. Product Specification Subjective to this report ................................................................ 6 2.3. Working Frequencies for this report ................................................................................ 7 2.4. Test Mode ....................................................................................................................... 7 2.5. Test Environment Condition ............................................................................................ 7 2.6. Test Software .................................................................................................................. 7 2.7. Description of Test Configuration .................................................................................... 8 2.8. Test System Details ........................................................................................................ 8 2.9. Duty Cycle ....................................................................................................................... 9 3. ANTENNA REQUIREMENTS .................................................................................................. 10 4. TEST EQUIPMENT CALIBRATION DATE .............................................................................. 11 5. MEASUREMENT UNCERTAINTY ........................................................................................... 13 6. TEST RESULT ......................................................................................................................... 14 6.1. Summary ....................................................................................................................... 14 6.2. Occupied Bandwidth Measurement .............................................................................. 15 6.2.1. Test Limit ................................................................................................................... 15 6.2.2. Test Procedure used ................................................................................................. 15 6.2.3. Test Setting ................................................................................................................ 15 6.2.4. Test Setup ................................................................................................................. 16 6.2.5. Test Result ................................................................................................................. 17 6.3. Output Power Measurement ......................................................................................... 19 6.3.1. Test Limit ................................................................................................................... 19 6.3.2. Test Procedure Used ................................................................................................. 19 6.3.3. Test Setting ................................................................................................................ 19 6.3.4. Test Setup ................................................................................................................. 20 6.3.5. Test Result of Output Power ...................................................................................... 21 6.4. Power Spectral Density Measurement .......................................................................... 22 6.4.1. Test Limit ................................................................................................................... 22 6.4.2. Test Procedure Used ................................................................................................. 22 Report No.: 2011RSU059-U1 4 of 55 6.4.3. Test Setting ................................................................................................................ 22 6.4.4. Test Setup .........................................…
Text truncated - open the document above for the full version.
Report No.: 2011RSU059-UT 1 of 3 Test Setup Photograph Description: Front View of Conducted Emission Test Setup Description: Back View of Conducted Emission Test Setup Report No.: 2011RSU059-UT 2 of 3 Description: Radiated Emission Test Setup for below 1GHz Description: Radiated Emission Test Setup for above 1GHz Report No.: 2011RSU059-UT 3 of 3 Description: RF Conducted Measurement Test Setup
| # | Rule Parts | Frequency Range | Power Output |
|---|---|---|---|
| 1 | 15C | 2.40 GHz - 2.48 GHz | 1.20 mW |

EnigmaBot
Equipment Class
DTS - Digital Transmission System