FCCID.CO- FCC ID Database
HomeCompaniesEquipment ClassesSearch

© 2026 FCC ID Database. All rights reserved.

AboutContactData sourced from FCC public records
  1. Home/
  2. Jiangsu Tellus Power Co., Ltd./
  3. 2AYGV-TP-CCSI-30KW

2AYGV-TP-CCSI-30KWDC Charger Station

Jiangsu Tellus Power Co., Ltd.
DC Charger Station - FCC ID 2AYGV-TP-CCSI-30KW - Jiangsu Tellus Power Co., Ltd.
Click to zoom

Application Details

Equipment Class
DXX - Part 15 Low Power Communication Device Transmitter
Date of Grant
Dec 17, 2020
Application Purpose
Original Equipment
Date of Application
Dec 17, 2020
Equipment Note
DC Charger Station
Frequency Range
13.56000000 - 13.56000000
Company
Jiangsu Tellus Power Co., Ltd.
Country
China

Documents & Files

Select a file to view

Users Manual

↗

Attestation Statements

↗

Cover Letter(s)

↗
↗

External Photos

↗

ID Label/Location Info

↗

Internal Photos

↗

Test Report

↗

Test Setup Photos

↗

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

Users Manual

1. General description NXP Semiconductors has developed the MIFARE Classic MF1S50yyX/V1 to be used in a contactless smart card according to ISO/IEC 14443 Type A. The MIFARE Classic EV1 1K MF1S50yyX/V1 IC is used in applications like public transport ticketing and can also be used for various other applications. 1.1 Anticollision An intelligent anticollision function allows to operate more than one card in the field simultaneously. The anticollision algorithm selects each card individually and ensures that the execution of a transaction with a selected card is performed correctly without interference from another card in the field. 1.2 Simple integration and user convenience The MF1S50yyX/V1 is designed for simple integration and user convenience which allows complete ticketing transactions to be handled in less than 100 ms. 1.3 Security and privacy • Manufacturer programmed 7-byte UID or 4-byte NUID identifier for each device •Random ID support •Mutual three pass authentication (ISO/IEC DIS 9798-2) •Individual set of two keys per sector to support multi-application with key hierarchy MF1S50yyX/V1 MIFARE Classic EV1 1K - Mainstream contactless smart card IC for fast and easy solution development Rev. 3.0 — 3 March 2014 279230 Product data sheet COMPANY PUBLIC Fig 1.Contactless MIFARE system 001aam199 MIFARE CARD PCD energy data MF1S50yyX_V1All information provided in this document is subject to legal disclaimers.© NXP Semiconductors N.V. 2014. All rights reserved. Product data sheet COMPANY PUBLIC Rev. 3.0 — 3 March 2014 279230 2 of 40 NXP Semiconductors MF1S50yyX/V1 MIFARE Classic EV1 1K - Mainstream contactless smart card IC 1.4 Delivery options • 7-byte UID, 4-byte NUID •Bumped die on sawn wafer •MOA4 and MOA8 contactless module 2.Features and benefits 2.1 EEPROM 3. Applications 4.Quick reference data [1]T amb =22°C, f=13,56Mhz, V LaLb = 1,5 V RMS Contactless transmission of data and en ergy supply Operating distance up to 100 mm de pending on antenna geometry a nd r eader configuration Operating frequency of 13.56 MHzData transfer of 106 kbit/s Data integrity of 16-bit CRC, parity , bit co ding, bit counting Anticollision Typical ticketing transaction time of < 100 ms (including backup management) 7 Byte UID or 4 Byte NUID Random ID support (7 Byte UID version)NXP Originality Check support 1 kB, organized in 16 sector s of 4 blocks ( one block consists of 16 byte) User definable access conditions for each memory block Data retention time of 10 yearsWrite endurance 200000 cycles Public transportationAccess management Electronic toll collectionCar parking School and campus cardsEmployee cards Internet cafésLoyalty Table 1.Quick reference data SymbolParameterConditionsMinTypMaxUnit C i input capacitance [1] 14.916.919.0pF f i input frequency-13.56- MHz EEPROM characteristics t ret retention timeT amb = 22 C10--year N endu(W) write enduranceT amb = 22 C100000200000-cycle MF1S50yyX_V1All information provided in this document is subject to legal disclaimers.© NXP Semiconductors N.V. 2014. All rights reserved. Product data sheet COMPANY PUBLIC Rev. 3.0 — 3 March 2014 279230 3 of 40 NXP Semiconductors MF1S50yyX/V1 MIFARE Classic EV1 1K - Mainstream contactless smart card IC 5. Ordering information 6. Block diagram Table 2.Ordering information Type numberPackage NameDescriptionVersion MF1S5001XDUD/V1 FFC Bump 8 inch wafer, 120 m thickness, on film frame carrier, electronic fail die marking according to SECS-II format), Au bumps, 7-byte UID - MF1S5001XDUF/V1 FFC Bump 8 inch wafer, 75 m thickness, on film frame carrier, electronic fail die marking according to SECS-II format), Au bumps, 7-byte UID - MF1S5000XDA4/V1 MOA4plastic leadless module carrier package; 35 mm wide tape, 7-byte UIDSOT500-2 MF1S5000XDA8/V1 MOA8plastic leadless module carrier package; 35 mm wide tape, 7-byte UIDSOT500-4 MF1S5031XDUD/V1 FFC Bump 8 inch wafer, 120 m thickness, on film frame carrier, electronic fail die marking according to SECS-II format), Au bumps, 4-byte non-unique ID - MF1S5031XDUF/V1 FFC Bump 8 inch wafer, 75 m thickness, on film frame carrier, electronic fail die marking according to SECS-II format), Au bumps, 4-byte non-unique ID - MF1S5030XDA4/V1 MOA4plastic leadless module carrier package; 35 mm wide tape, 4-byte non-unique ID SOT500-2 MF1S5030XDA8/V1 MOA8plastic leadless module carrier package; 35 mm wide tape, 4-byte non-unique ID SOT500-4 Fig 2.Block diagram of MF1S50yyX/V1 001aan006 RF INTERFACE UART ISO/IEC 14443 TYPE A LOGIC UNIT RNG CRC EEPROM CRYPTO1 POWER ON RESET VOLTAGE REGULATOR CLOCK INPUT FILTER RESET GENERATOR CRYSTAL LOGIC UNIT 27.12MHZ MF1S50yyX_V1All information provided in this document is subject to legal disclaimers.© NXP Semiconductors N.V. 2014. All rights reserved. Product data sheet COMPANY PUBLIC Rev. 3.0 — 3 March 2014 279230 4 of 40 NXP Semiconductors MF1S50yyX/V1 MIFARE Classic EV1 1K - Mainstream contactless smart card IC 7. Pinning information 7.1 Pinning The pinning for the MF1S50yyX/V1DAx is shown as an example in Figure 3 for the MOA4 contactless module. For the contactless module MOA8, the pinning is analogous and not explicitly shown. Fig 3.Pin configuration for SOT500-2 (MOA4) Table 3.Pin allocation table PinSymbol LALAAntenna coil connection LA LBLBAntenna coil connection LB 001aan002 LALBtop view MF1S50yyX_V1All information provided in this document is subject to legal disclaimers.© NXP Semiconductors N.V. 2014. All rights reserved. Product data sheet COMPANY PUBLIC Rev. 3.0 — 3 March 2014 279230 5 of 40 NXP Semiconductors MF1S50yyX/V1 MIFARE Classic EV1 1K - Mainstream contactless smart card IC 8. Functional description 8.1 Block description The MF1S50yyX/V1 chip consists of a 1 kB EEPROM, RF interface and Digital Control Unit. Energy and data are transferred via an antenna consisting of a coil with a small number of turns which is directly connected to the MF1S50yyX/V1. No further external components are necessary. Refer to the documen…

Text truncated - open the document above for the full version.

Attestation Statements

Model difference declaration letter Differences Description We Jiangsu Tellus Power Co., Ltd. state: Product: DC Charger Station Model Name: TP-CCSI-30KW,TP-CCS1,CHAdeMO-60KW, TP-CCS1,CHAdeMO-120KW The above product with same circuit, PCB layout, electrical parts, materials and wiring structures, Appearance shape, the materials of decorative accessories is same, only different color, Signatory Date: 12-16-2020 Signature : Name: Peter Pang Title:Engineer Company: Jiangsu Tellus Power Co., Ltd. Address:Rm.409,Bldg.1,No.69,South Donghuan Road,Ecnomic and Technological Development Zone,Yancheng

Cover Letter(s)

C5266091_X8_Ed.1 1/1 Jiangsu Tellus Power Co., Ltd. Company: Jiangsu Tellus Power Co., Ltd. Address: Rm.409,Bldg.1,No.69,South Donghuan Road,Ecnomic and Technological Development Zone,Yancheng Product Name:DC Charger Station Model Number:TP-CCSI-30KW,TP-CCS1,CHAdeMO-60KW, TP-CCS1,CHAdeMO-120KW FCC Identifier:2AYGV-TP-CCSI-30KW We authorize LGAI Technological Center S.A., Ronda de la Font del Carme, s/n, 08193 Bellaterra, Spain, to act on our behalf on all matters concerning the above named equipment. Any individual within LGAI Technological Center S.A. is authorized to act on our behalf and take action on the application. We declare that authorize LGAI Technological Center S.A., Ronda de la Font del Carme, s/n, 08193 Bellaterra, Spain, is allowed to forward all information related to the approval project to the Federal Communication Commission and to discuss any issues concerning the approval application. Any and all acts carried out by LGAI Technological Center S.A. on our behalf shall have the same effect as acts of our own. Name: Peter Pang Date:17 Dec ,2020 Title: Engineer Signature of applicant:

Cover Letter(s)

C5266091_X10_Ed.2 1/1 Jiangsu Tellus Power Co., Ltd. Office of Engineering Technology Federal Communications Commission 7435 Oakland Mills Road Columbia, MD 21046 Date: 17 Dec, 2020 Subject: Request for Confidentiality FCC ID: 2AYGV-TP-CCSI-30KW To Whom It May Concern, Pursuant to the provisions of Sections 0.457 and 0.459 of Commission's rules (47CFR0.457, 0.459), we are requesting the Commission to withhold the following attachment(s) as confidential document from public disclosure. Exhibits Long-Term Confidentiality Short-Term Confidentiality NOTE 2 ID Label/Location No No Attestation Statement No No External Photos No ☐ Block Diagram ☒ ☐ Schematics ☒ ☐ Test Report No No Test Setup Photos No ☐ User’s Manual ☐ NOTE 1 ☐ Internal Photos ☐ NOTE 1 ☐ Parts List / Tune Up ☐ ☐ RF Exposure Info No No Operational Description ☒ ☐ Cover Letter(s) No No SDR Software / Security Info ☐ No NOTE 1: Long-Term Confidentiality may be permitted under special conditions (See II. LONG-TERM CONFIDENTIALITY, Section 3 of KDB 726920, use last in force) NOTE 2: Short-Term Confidentiality can be requested for a maximum of 180 days from the date of the grant. Above mentioned document contains detailed system and equipment description are considered as proprietary information in operation of the equipment. The public disclosure of above documents might be harmful to our company and would give competitor an unfair advantage in the market. In case of short-term Confidentiality, the applicant requests the exhibits selected above are withheld from public view for a period of ______ days from the date of the Grant of Equipment Authorization and prior to marketing. It is our understanding that all measurement test reports, FCC ID label format and correspondent during certification review process cannot be granted as confidential documents and those information will be available for public review once the grant of equipment authorization is issued. C5266091_X10_Ed.2 1/1 Sincerely, Signature: Name: Peter Pang Title: Engineer

External Photos

Page 1 of 3 Report No.:FCS202011005 External&Internal photos Photo 1 Photo 2 Model: TP-CCSI-30KW Page 2 of 3 Report No.:FCS202011005 Photo 3 Photo 4 Page 3 of 3 Report No.:FCS202011005 Photo 5 Photo 6

ID Label/Location Info

Label and Label Location FCC ID: 2AYGV-TP-CCSI-30KW L*W: 10mm*5mm White label and black font

Internal Photos

Page 1 of 3 Report No.:FCS202011005 External&Internal photos Photo 1 Photo 2 Model: TP-CCSI-30KW Page 2 of 3 Report No.:FCS202011005 Photo 3 Photo 4 Page 3 of 3 Report No.:FCS202011005 Photo 5 Photo 6

Test Report

Flux Compliance Service Laboratory Room 105 Floor Bao hao Technology Building 1 NO.15 Gong ye West Road Hi-Tech Industrial, Song shan lake Dongguan Tel: 769-27280901 Fax:769-27280901 http://www.FCS-lab.com RF Test Report Report No: FCS202011005W01 Issued for Applicant: Jiangsu Tellus Power Co., Ltd. Address: Rm.409,Bldg.1,No.69,South Donghuan Road,Ecnomic and Technological Development Zone,Yancheng Product Name: DC Charger Station Brand Name: N/A Model Name: TP-CCSI-30KW Series Model: TP-CCS1,CHAdeMO-60KW,TP-CCS1,CHAdeMO-120KW FCC ID: 2AYGV-TP-CCSI-30KW Issued By: Flux Compliance Service Laboratory Add: Room 105 Floor Bao hao Technology Building 1 NO.15 Gong ye West Road Hi-Tech Industrial, Song shan lake Dongguan Tel: 769-27280901 Fax:769-27280901 http://www.FCS-lab.com Page 2 of 26 Report No.:FCS202011005W01 Flux Compliance Service Laboratory Room 105 Floor Bao hao Technology Building 1 NO.15 Gong ye West Road Hi-Tech Industrial, Song shan lake Dongguan Tel: 769-27280901 Fax:769-27280901 http://www.FCS-lab.com TEST RESULT CERTIFICATION Applicant’s Name ................... : Jiangsu Tellus Power Co., Ltd. Address ................................. : Rm.409,Bldg.1,No.69,South Donghuan Road,Ecnomic and Technological Development Zone,Yancheng Manufacture's Name .............. : Jiangsu Tellus Power Co., Ltd. Address ................................. : Rm.409,Bldg.1,No.69,South Donghuan Road,Ecnomic and Technological Development Zone,Yancheng Product Description Product Name ........................ : DC Charger Station Model Name .......................... : TP-CCSI-30KW Series Model .......................... : TP-CCS1,CHAdeMO-60KW,TP-CCS1,CHAdeMO-120KW Test Standards ....................... : FCC Rules and Regulations Part 15 Subpart C, Section 225 Test Procedure....................... : ANSI C63.10:2013 This device described above has been tested FCS, the test results show that the equipment under test (EUT) is in compliance with the FCC requirements. And it is applicable only to the tested sample identified in the report. This report shall not be reproduced except in full, without the written approval of FCS, this document may be altered or revised by FCS, personal only, and shall be noted in the revision of the document.. Date of Test .............................. : Date (s) of performance of tests . : Nov. 19, 2020 ~ Dec. 04, 2020 Date of Issue ............................ : Dec. 04, 2020 Test Result ................................ : Pass Tested by : (Scott Shen) Reviewed by : (Duke Qian) Approved by : (Kait Chen) Page 3 of 26 Report No.:FCS202011005W01 Flux Compliance Service Laboratory Room 105 Floor Bao hao Technology Building 1 NO.15 Gong ye West Road Hi-Tech Industrial, Song shan lake Dongguan Tel: 769-27280901 Fax:769-27280901 http://www.FCS-lab.com Table of Contents Page 1. SUMMARY OF TEST RESULTS 6 1.1 TEST FACTORY 7 1.2 MEASUREMENT UNCERTAINTY 7 2. GENERAL INFORMATION 8 2.1 GENERAL DESCRIPTION OF THE EUT 8 2.2 DESCRIPTION OF THE TEST MODES 9 2.3 DESCRIPTION OF NECESSARY ACCESSORIES AND SUPPORT UNITS 10 2.4 EQUIPMENTS LIST 11 3 CONDUCTED EMISSION MEASUREMENT 12 3.1 LIMIT 12 3.2 TEST PROCEDURE 12 3.3 TEST SETUP 13 3.4 TEST RESULTS 13 4. RADIATED EMISSION MEASUREMENT 14 4.1 LIMIT 14 FCC §15.225(A), (B), (C); RSS-GEN B.6, FCC §15.225(D) 14 4.2 TEST PROCEDURE 15 4.3 TEST SETUP 16 4.4 TEST RESULTS 17 FOR FIELD STRENGTH OF THE FUNDAMENTAL SIGNAL 17 (30MHZ-1000MHZ) 19 5. 20 DB BANDWIDTH TEST 21 5.1 TEST PROCEDURE 21 FCC §2.1049&15.215(C); RSS-GEN 21 5.2 TEST SETUP 21 5.3 TEST RESULTS 22 6 FREQUENCY STABILITY MEASUREMEN 24 6.1 LIMIT 24 BE PERFORMED USING A NEW BATTERY 24 6.2 TEST PROCEDURE 24 6.3TEST RESULTS 25 7 ANTENNA REQUIREMENT 26 Page 4 of 26 Report No.:FCS202011005W01 Flux Compliance Service Laboratory Room 105 Floor Bao hao Technology Building 1 NO.15 Gong ye West Road Hi-Tech Industrial, Song shan lake Dongguan Tel: 769-27280901 Fax:769-27280901 http://www.FCS-lab.com Table of Contents Page 7.1 STANDARD REQUIREMENT 26 7.2 EUT ANTENNA 26 Page 5 of 26 Report No.:FCS202011005W01 Flux Compliance Service Laboratory Room 105 Floor Bao hao Technology Building 1 NO.15 Gong ye West Road Hi-Tech Industrial, Song shan lake Dongguan Tel: 769-27280901 Fax:769-27280901 http://www.FCS-lab.com Revision History Rev. Issue Date Effect Page Contents 00 Dec. 04, 2020 All Initial Issue Page 6 of 26 Report No.:FCS202011005W01 Flux Compliance Service Laboratory Room 105 Floor Bao hao Technology Building 1 NO.15 Gong ye West Road Hi-Tech Industrial, Song shan lake Dongguan Tel: 769-27280901 Fax:769-27280901 http://www.FCS-lab.com 1. SUMMARY OF TEST RESULTS Test Summary FCC part No. Test Item Judgment Remark 15.207 Conducted Emission NA -- 15.225(d) &15.209 Radiated Emission PASS -- 15.225(a) Field Strength of Fundamental Emissions PASS 2.1049 20dB Bandwidth PASS 15.225(e) Frequency Stability PASS 15.203 Antenna Requirement PASS -- NOTE: (1)” N/A” denotes test is not applicable in this Test Report (2) All tests are according to ANSI C63.10-2013 Page 7 of 26 Report No.:FCS202011005W01 Flux Compliance Service Laboratory Room 105 Floor Bao hao Technology Building 1 NO.15 Gong ye West Road Hi-Tech Industrial, Song shan lake Dongguan Tel: 769-27280901 Fax:769-27280901 http://www.FCS-lab.com 1.1 TEST FACTORY Company Name: Flux Compliance Service Laboratory Address: Room 105 Floor Bao hao Technology Building 1 NO.15 Gong ye West Road Hi-Tech Industrial, Song shan lake Dongguan Telephone: +86-769-27280901 Fax: +86-769-27280901 FCC Test Firm Registration Number: 514908 Designation number: CN0127 A2LA accreditation number:5545.01 1.2 MEASUREMENT UNCERTAINTY The reported uncertainty of measurement y ±U, where expended uncertainty U is based on a standard uncertainty multiplied by a coverage factor of k=2, providing a level of confidence of approximately 95 %. No. Item Uncertainty 1 RF output power, conducted ±0.71dB 2 Unwanted Emissions, conducted ±2.98 dB 3 Conducted Emission (9KHz-150KHz) ±4.13 dB 4 Conduct…

Text truncated - open the document above for the full version.

Test Setup Photos

Page 1 of 1 Report No.:FCS202011005W01 9K-30MHz for radiated emission test setup 30MHZ- 1GHz for radiated emission test setup Model: TP-CCSI-30KW

Contact Information

Applicant

Peter Pang(Engineer)
[email protected]15818718994Fax: 15818718994

Technical Contact

Flux Compliance Service LaboratoryAndy Yue
[email protected]86-769-27280901

Dongguan · China

Non-Technical Contact

Flux Compliance Service LaboratoryAndy Yue
[email protected]86-769-27280901

Test Firm

Flux Compliance Service LaboratoryAndy Yue
[email protected]13510297284

Technical Specifications

#Rule PartsFrequency RangePower Output
115C13.56 MHz - 13.56 MHz-
Confidentiality
Long Term