Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.
Overview of the system Wittra’s sensor tags, mesh-routers and gateway together form a mesh network based on 6LoWPAN (IPv6 over Low-Power Wireless Personal Area Networks). The network is IP-enabled down to the sensor tags, where data is communicated wirelessly over IEEE 802.15.4g radios in the Sub-GHz RF band. The data can easily be accessed via our Wittra portal by adding an integration; For further information please have a look at Accessing your data. Mesh network In a mesh network, data can be routed from one node to another to reach the end destination (in our case a gateway). In comparison, in a star network all nodes would communicate directly with a central hub. By using a mesh network we extend the range of a network further than one single hop. Mesh networks are self-healing in the sense that data can be re-routed when nodes fail along the path. In our mesh network we have sensor tags, mesh-routers and a border-router (attached to a gateway). A sensor tag acts as a leaf node in a mesh network topology, which means that it will only produce and send data but not forward data packets from other devices. Thus, the radio of a tag does not need to be turned on all the time which decreases power consumption and - as a consequence - increases operational lifetime. A mesh-router - in contrast - has the main purpose of forwarding data packets. This is the reason why it needs to be powered all the time. A border-router sits inside a gateway. It is the end destination of data packets in a mesh network. The border-router conveys the data to the gateway which then sends the data up securely, via HTTPS, to our Wittra portal. Network settings Channels Our solution operates in the Sub-GHz frequency band, and uses Frequency Hopping (FH) for increased reliability. The devices switch frequency several times per second, to mitigate the impact of any individual bad channel. When a transmission fails on a bad channel, new attempts will be performed over di erent channels, increasing the likelihood to eventually succeed. Note that the Sub-GHz band is much less prone to interference than the 2.4 GHz band, since there are fewer products on the market that uses this spectrum and at the same time government regulations impose limits on the radio usage per device. However, interference still exists and that is why FH is key to building robust networks. We will soon o er the ability to configure the channel set for any given system. This way, you will be able to exclude any channel that you want or must keep unused to various administrative reasons. You will also be able to isolate multiple Wittra systems if desired, by selecting non- overlapping channel sets. PAN ID The PAN ID is a unique ID for a group of physically co-located IEEE 802.15.4 devices, each local network should have its own ID. Networks near each other mustn't have the same PAN ID. It is randomly selected at deployment but can be changed at any point of time in the Wittra portal. The PAN ID can be used to connect two networks, so a tag can move in between sites. Expected range The radio in the sensor tag, mesh-router and border-router runs Sub-GHz in the industrial, scientific and medical (ISM) frequency band. By communicating in this frequency domain you have a better range than for example the higher frequency band of 2.4 GHz. You also have a better penetration meaning you can communicate in harsher radio environments such as construction sites and in cities, where line of sight is not an option. The expected range of the system depends if you have line of sight or non-line of sight and how high up you can put the mesh-routers. But in average the range is around 100-200m. Secure system We use a Secure-by-design approach where we incorporate security from the early architecture design stage and throughout the evolution of the products. The key protections we have are summarized below: Spoofing is mitigated using an authentication process utilizing JWTs that are signed by a private key stored in a TPM on the gateway which are checked in registered devices on our cloud service, where the respective public key is stored. Tampering is mitigated using DTLS/TLS to encrypt the data sent between sensor tag and gateway, and between gateway and Wittra portal. One caveat is that with the current protocol bridging between CoAP and HTTP in the gateway, the gateway has to be a trusted device. Confidentiality is obtained by running CoAP over DTLS from sensor tag to gateway and by running HTTP over TLS from gateway to Wittra cloud service. The HTTP/TLS link is verified using an X.509 certificate provided by the server (in this case Google Cloud Platform) and issued by a trusted authority. The CoAP/DTLS link is verified with a Pre-Shared Key (PSK) which is randomly generated at deployment. This key must be kept secret and therefore the gateway has to be treated as a trusted device. See Updating security settings for more information. Elevation of Privileges is handled by standard Linux account authentication and authorization mechanisms in the gateway. On our Wittra cloud service it is handled by Googles Cloud Identity and Access Management (IAM). Overview of Wittra portal Wittra portals provide a rich user interface for administration and maintenance of Wittra solutions. The following screenshot gives you an overview of the Wittra portal portal. Top bar Indicates the name of the organization(s). You can also search through the list using the search functionality. On the top right there is a ?symbol with quick links to guides and walkthroughs. On the very right you can find your account related information. Here you can edit your user profile information and log out of the portal. Side panel Shows the list of projects that is under the current organization. You can also search through the list using the search functionality. On the bottom le you have an admin view where you can manage your user permissions, organization information and billing. Project Das…
Text truncated - open the document above for the full version.
Request for Confidentiality (FCC) Wittra Sweden AB Org.nr: 556932-0988 Rosenlundsgatan 40, 11853 Stockholm SWEDEN www.wittra.se Date: 2021-03-31 Subject: Confidentiality Request for : Wittra Gateway (WITTRA GATEWAY 1.0 US) Pursuant to FCC 47 CRF 0.457(d) and 0.459, the applicant requests that a part of the subject FCC application be held confidential. Type of Confidentiality Requested Exhibit ☐ Short Term ☑ Permanent Block Diagrams ☐ Short Term External Photos ☐ Short Term ☐ Permanent Internal Photos ☐ Short Term ☑ Permanent Operation Description/Theory of Operation ☐ Short Term ☑ Permanent Part List/Tune-Up Procedure ☐ Short Term ☑Permanent Schematics ☐ Short Term Test Setup Photos ☐ Short Term ☐ Permanent User’s Manual Wittra Sweden AB has spent substantial effort in developing this product and it is one of the first of its kind in industry. Having the subject information easily available to "competition" would negate the advantage they have achieved by developing this product. Not protecting the details of the design will result in financial hardship. Permanent Confidentiality: The applicant requests the exhibits listed above as permanently confidential be permanently withheld from public review due to materials that contain trade secrets and proprietary information not customarily released to the public. Short-Term Confidentiality: The applicant requests the exhibits selected above as short term confidential be withheld from public view for a period of 180 days from the date of the Grant of Equipment Authorization and prior to marketing. This is to avoid premature release of sensitive information prior to marketing or release of the product to the public. Applicant is also aware that they are responsible to notify TUV Rheinland in the event information regarding the product or the product is made available to the public. TUV Rheinland will then release the documents listed above for public disclosure pursuant to FCC Public Notice DA 04-1705. Sincerely, CTO By: Warwick Taws (Signature/Title) (Print name)
Agency Authorization (FCC) Wittra Sweden AB Org.nr: 556932-0988 Rosenlundsgatan 40, 11853 Stockholm SWEDEN www.wittra.se Authority to Act as Agent Date: 2021-04-01 TUV Rheinland Group 762 Park Avenue Youngsville, NC 27596 To Whom It May Concern: I appoint TUV Rheinland (Shenzhen) Co., Ltd. to act as our agent in the preparation of this application for equipment certification. I certify that submitted documents properly describe the device or system for which equipment certification is sought. I also certify that each unit manufactured, imported or marketed, as defined in the FCC or Industry Canada’s regulations will have affixed to it a label identical to that submitted for approval with this application. For instances where our authorized agent signs the application for certification on our behalf, I acknowledge that all responsibility for complying with the terms and conditions for Certification, as specified by TUV Rheinland Group, still resides with Wittra Sweden AB, of Rosenlundsgatan 40, 11853 Stockholm, Sweden. For TCB applications, we certify that we are not subject to denial of federal benefits, that includes FCC benefits, pursuant to Section 5301 of the Anti-Drug Abuse Act of 1988, 21 U.S.C. 862. Further, no party, as defined in 47 CFR 1.2002 (b), to the application is subject to denial of federal benefits, that includes FCC benefits. Thank you, Agency Agreement Expiration Date: 12 months By : Warwick Taws (Signature) (Print Name) Title : CTO Telephone : +46 735 23 25 77 On behalf of : Wittra Sweden AB (Company Name)
Prüfbericht - Produkte Test Report – Products Prüfbericht-Nr.: Test report no.: 60440989-001 Auftrags-Nr.: Order no.: 23870482 030 Seite 1 von 7 Page 1 of 7 Kunden-Referenz-Nr.: Client reference no.: 2311184 Auftragsdatum: Order date: 2020.12.09 Auftraggeber: Client: Wittra Sweden AB Prüfgegenstand: Test item: Gateway 1.0 US Bezeichnung / Typ-Nr.: Identification / Type no.: Gateway 1.0 / FCC ID:2AYHX00347 Auftrags-Inhalt: Order content: RF Exposure Evaluation Prüfgrundlage: Test specification: FCC 47 CFR 2.1091 IEEE Std. C95.1:2005 Wareneingangsdatum: Date of sample receipt: N/A Prüfmuster-Nr.: Test sample no: N/A Prüfzeitraum: Testing period: N/A - Ort der Prüfung: Place of testing: Lund, Sweden Prüflaboratorium: Testing laboratory: TÜV Rheinland Sweden Prüfergebnis*: Test result*: Siehe Sonstiges / See Other überprüft von: reviewed by: X Signed by: Niall Forrester genehmigt von: authorized by: X Signed by: Per Isacsson Datum: 2021.04.16 Date: Datum: 2021.04.16 Date: Stellung / Position: Senior Technical Expert Stellung / Position: Senior Technical Expert Sonstiges / Other: See below for details Zustand des Prüfgegenstandes bei Anlieferung: Condition of the test item at delivery: Prüfmuster vollständig und unbeschädigt Test item complete and undamaged * Legende: 1 = sehr gut 2 = gut 3 = befriedigend 4 = ausreichend 5 = mangelhaft P(ass) = entspricht o.g. Prüfgrundlage(n) F(ail) = entspricht nicht o.g. Prüfgrundlage(n) N/A = nicht anwendbar N/T = nicht getestet * Legend: 1 = very good 2 = good 3 = satisfactory 4 = sufficient 5 = poor P(ass) = passed a.m. test specification(s) F(ail) = failed a.m. test specification(s) N/A = not applicable N/T = not tested Dieser Prüfbericht bezieht sich nur auf das o.g. Prüfmuster und darf ohne Genehmigung der Prüfstelle nicht auszugsweise vervielfältigt werden. Dieser Bericht berechtigt nicht zur Verwendung eines Prüfzeichens. This test report only relates to the a. m. test sample. Without permission of the test center this test report is not permitted to be duplicated in extracts. TÜV Rheinland Sweden AB. Mobilvägen 10, 223 62 Lund, Sweden Phone.: +46 46 272 57 46 Mail: [email protected] Web: www.tuv.com Prüfbericht – Produkte Prüfbericht-Nr.: / Test Report No.: Test Report – Products 60440989-001 Seite 2 von 7 Page 2 of 7 TÜV Rheinland Sweden AB. Mobilvägen 10, 223 62 Lund, Sweden Phone.: +46 46 272 57 46 Mail: [email protected] Web: www.tuv.com Revision History60440989-00160440989-001 Revision Date Remarks Author 001 2021.04.16 First Release Niall Forrester Note: Latest revision report will replace all previous reports This report based on RF Exposure FCC 47CR 2-1091 IEEE C95 Template version 1.1 Statement of Compliance Evaluation was performed based on FCC 47 CFR 2.1091 and IEEE C95.1:2005, together with the “General Population / Uncontrolled” requirements set out in FCC 47 CFR 1.1310 Table 1 (B) The calculations below show that the Gateway 1.0 / FCC ID:2AYHX00347 device is compliant with these requirements at a distance of 20cm for all supported wireless transmitter technologies Table of Contents 1. GENERAL INFORMATION ................................................................................................................................... 3 1.1 Test Site ........................................................................................................................................................ 3 1.2 Client Information .......................................................................................................................................... 3 2. PRODUCT INFORMATION................................................................................................................................... 4 2.1 General Description ...................................................................................................................................... 4 2.2 Device Usage and Evaluation Distance ....................................................................................................... 4 2.3 Wireless Technologies and Bands Supported by the EUT .......................................................................... 4 2.4 Simultaneous Transmission Configurations ................................................................................................. 5 2.5 Conducted Power and Antenna Gain ........................................................................................................... 5 3. TEST METHODS .................................................................................................................................................. 6 3.1 Test Standards .............................................................................................................................................. 6 3.2 Additional references .................................................................................................................................... 6 3.3 Limits ............................................................................................................................................................. 6 4. EVALUATION DETAILS ........................................................................................................................................ 7 4.1 Power Density (S) at 20cm Distance for Each Band and Technology ......................................................... 7 Prüfbericht – Produkte Prüfbericht-Nr.: / Test Report No.: Test Report – Products 60440989-001 Seite 3 von 7 Page 3 of 7 TÜV Rheinland Sweden AB. Mobilvägen 10, 223 62 Lund, Sweden Phone.: +46 46 272 57 46 Mail: [email protected] Web: www.tuv.com 1. GENERAL INFORMATION 1.1 Test Site Test Facility: TÜV Rheinland Sweden AB Address: Mobilvägen 10 223 62 Lund Sweden Swedac Registration Number: FCC Test Firm Registration Number: ISED Test Site Registration Number: 10325 517458 24753 1.2 Client Information Company Name: Wittra Sweden AB Address: Rosenlundsgatan 40 0TR Sto…
Text truncated - open the document above for the full version.
Prüfbericht - Produkte Test Report – Products Prüfbericht-Nr.: Test report no.: 60440947-003 Auftrags-Nr.: Order no.: 23870482 030 Seite 1 von 55 Page 1 of 55 Kunden-Referenz-Nr.: Client reference no.: 2311184 Auftragsdatum: Order date: 2020.12.09 Auftraggeber: Client: Wittra Sweden AB Prüfgegenstand: Test item: Gateway 1.0 US Bezeichnung / Typ-Nr.: Identification / Type no.: Gateway 1.0 / FCC ID:2AYHX00347 Auftrags-Inhalt: Order content: Accrediated test according to FCC Part 15C Prüfgrundlage: Test specification: FCC 47 CFR Part 15.247 with parts 15.207 & 15.209 ANSI C63.10: 2013 Wareneingangsdatum: Date of sample receipt: 2020.12.09 Prüfmuster-Nr.: Test sample no: See section 2.3 Prüfzeitraum: Testing period: 2021.01.22 – 2021.06.24 Ort der Prüfung: Place of testing: Lund, Sweden Prüflaboratorium: Testing laboratory: TÜV Rheinland Sweden Prüfergebnis*: Test result*: Pass überprüft von: reviewed by: X Signed by: Niall Forrester genehmigt von: authorized by: X Signed by: Per Isacsson Datum: 2021.06.24 Date: Datum: 2021.06.24 Date: Stellung / Position: Senior Technical Expert Stellung / Position: Lab Manager Sonstiges / Other: Note: This report contains information for IEEE 802.15.4 measurements only. Conducted RF testing was performed on “Sensor tag 1.0” devices (FCC ID 2AYHX00348) which are functionally and electronically identical to the hardware contained in the Gateway device for the purposes of the testing in this report. Zustand des Prüfgegenstandes bei Anlieferung: Condition of the test item at delivery: Prüfmuster vollständig und unbeschädigt Test item complete and undamaged * Legende: 1 = sehr gut 2 = gut 3 = befriedigend 4 = ausreichend 5 = mangelhaft P(ass) = entspricht o.g. Prüfgrundlage(n) F(ail) = entspricht nicht o.g. Prüfgrundlage(n) N/A = nicht anwendbar N/T = nicht getestet * Legend: 1 = very good 2 = good 3 = satisfactory 4 = sufficient 5 = poor P(ass) = passed a.m. test specification(s) F(ail) = failed a.m. test specification(s) N/A = not applicable N/T = not tested Dieser Prüfbericht bezieht sich nur auf das o.g. Prüfmuster und darf ohne Genehmigung der Prüfstelle nicht auszugsweise vervielfältigt werden. Dieser Bericht berechtigt nicht zur Verwendung eines Prüfzeichens. This test report only relates to the a. m. test sample. Without permission of the test center this test report is not permitted to be duplicated in extracts. TÜV Rheinland Sweden AB. Mobilvägen 10, 223 62 Lund, Sweden Phone.: +46 46 272 57 46 Mail: [email protected] Web: www.tuv.com Prüfbericht – Produkte Prüfbericht-Nr.: / Test Report No.: Test Report – Products 60440947-003 Seite 2 von 55 Page 2 of 55 TÜV Rheinland Sweden AB. Mobilvägen 10, 223 62 Lund, Sweden Phone.: +46 46 272 57 46 Mail: [email protected] Web: www.tuv.com Revision History60440947-00360440947-003 REVISION DATE REMARKS AUTHOR 001 2021.04.16 First release Niall Forrester 002 2021.05.12 Corrected table in 4.7.1 image in 4.7.2 & added plots to section 4.11.2 Niall Forrester 003 2021.06.24 Corrected gain figures, 20dB BW and typos Niall Forrester Note: Latest revision report will replace all previous reports This report based on FCC Part 15.247 Template version 1.2 Summary of Test Results FCC 47 CFR Rule Part Test Description Applicability Report Section RESULT REMARKS 15.207 AC Power Line Conducted Emissions (Intentional Radiators) YES 4.1 PASS 15.209 Radiated Emissions (Intentional Radiators) YES 4.2 PASS 15.247 (d) Antenna Conducted Emissions NO 4.3 N/A Radiated testing performed 15.247 (d) Band Edge Compliance (Authorized Band) YES 4.4 PASS 15.247 (d) Band Edge Compliance (Restricted Band) YES 4.5 PASS 15.247 (a)(1) 20dB Bandwidth YES 4.6 PASS 15.247 (a)(1) Carrier (Hopping Channel) Separation YES 4.7 PASS 15.247 (a)(1) Number of Hopping Channels YES 4.8 PASS 15.247 (a)(1) Time of Occupancy (Dwell Time) YES 4.9 PASS 15.247 (a)(2) 6dB Bandwidth NO 4.10 N/A Frequency Hopping Device 15.247 (b) Peak Conducted Output Power YES 4.11 PASS 15.247 (e) Power Spectral Density NO 4.12 N/A Frequency Hopping Device Possible test case verdicts: - Test case does not apply to the test object: N/A - Test object complies with the requirement: PASS or COMPLIANT - Test object does not meet the requirement: FAIL or NOT COMPLIANT - Test case not performed on the test object: N.P. Note 1: the device includes pre-certified modules as described in section 2.1 below Prüfbericht – Produkte Prüfbericht-Nr.: / Test Report No.: Test Report – Products 60440947-003 Seite 3 von 55 Page 3 of 55 TÜV Rheinland Sweden AB. Mobilvägen 10, 223 62 Lund, Sweden Phone.: +46 46 272 57 46 Mail: [email protected] Web: www.tuv.com Table of Contents 1. GENERAL INFORMATION ................................................................................................................................... 4 1.1 Test Site ............................................................................................................................................................................................ 4 1.2 Client Information .............................................................................................................................................................................. 4 2. PRODUCT INFORMATION................................................................................................................................... 5 2.1 General Description........................................................................................................................................................................... 5 2.2 Device Characteristics ....................................................................................................................................................................... 5 2.3 Test Samples .................................................................................................................................................................................... 6 2.4 Wireless Technologies and Bands …
Text truncated - open the document above for the full version.
Prüfbericht - Produkte Test Report – Products Prüfbericht-Nr.: Test report no.: 60440951-001 Auftrags-Nr.: Order no.: 23870482 030 Seite 1 von 20 Page 1 of 20 Kunden-Referenz-Nr.: Client reference no.: 2311184 Auftragsdatum: Order date: 2020.12.09 Auftraggeber: Client: Wittra Sweden AB Prüfgegenstand: Test item: Gateway 1.0 US Bezeichnung / Typ-Nr.: Identification / Type no.: Gateway 1.0 / FCC ID:2AYHX00347 Auftrags-Inhalt: Order content: Accredited testing according to FCC Part 15B Prüfgrundlage: Test specification: FCC 47 CFR Part 15B with parts 15.107 & 15.109 ANSI C63.4: 2014 Wareneingangsdatum: Date of sample receipt: 2020.12.09 Prüfmuster-Nr.: Test sample no: See section 2.3 Prüfzeitraum: Testing period: 2021.01.22 – 2021.02.23 Ort der Prüfung: Place of testing: Lund, Sweden Prüflaboratorium: Testing laboratory: TÜV Rheinland Sweden Prüfergebnis*: Test result*: Pass überprüft von: reviewed by: X Signed by: Niall Forrester genehmigt von: authorized by: X Signed by: Per Isacsson Datum: 2021.04.16 Date: Datum: 2021.04.16 Date: Stellung / Position: Senior Technical Expert Stellung / Position: Lab Manager Sonstiges / Other: Zustand des Prüfgegenstandes bei Anlieferung: Condition of the test item at delivery: Prüfmuster vollständig und unbeschädigt Test item complete and undamaged * Legende: 1 = sehr gut 2 = gut 3 = befriedigend 4 = ausreichend 5 = mangelhaft P(ass) = entspricht o.g. Prüfgrundlage(n) F(ail) = entspricht nicht o.g. Prüfgrundlage(n) N/A = nicht anwendbar N/T = nicht getestet * Legend: 1 = very good 2 = good 3 = satisfactory 4 = sufficient 5 = poor P(ass) = passed a.m. test specification(s) F(ail) = failed a.m. test specification(s) N/A = not applicable N/T = not tested Dieser Prüfbericht bezieht sich nur auf das o.g. Prüfmuster und darf ohne Genehmigung der Prüfstelle nicht auszugsweise vervielfältigt werden. Dieser Bericht berechtigt nicht zur Verwendung eines Prüfzeichens. This test report only relates to the a. m. test sample. Without permission of the test center this test report is not permitted to be duplicated in extracts. TÜV Rheinland Sweden AB. Mobilvägen 10, 223 62 Lund, Sweden Phone.: +46 46 272 57 46 Mail: [email protected] Web: www.tuv.com Prüfbericht – Produkte Prüfbericht-Nr.: / Test Report No.: Test Report – Products 60440951-001 Seite 2 von 20 Page 2 of 20 TÜV Rheinland Sweden AB. Mobilvägen 10, 223 62 Lund, Sweden Phone.: +46 46 272 57 46 Mail: [email protected] Web: www.tuv.com Revision History60440951-00160440951-001 REVISION DATE REMARKS AUTHOR 001 2021.04.16 First release Nial Forrester Note: Latest revision report will replace all previous reports This report based on FCC Part 15B no JBP Template version 1.2 Summary of Test Results FCC 47 CFR Rule Part Test Description Applicability Report Section RESULT REMARKS 15.107 AC Power Line Conducted Emissions (Unintentional Radiators) YES 4.1 PASS 15.109 Radiated Emissions (Unintentional Radiators) YES 4.2 PASS Possible test case verdicts: - Test case does not apply to the test object: N/A - Test object complies with the requirement: PASS or COMPLIANT - Test object does not meet the requirement: FAIL or NOT COMPLIANT - Test case not performed on the test object: N.P. Prüfbericht – Produkte Prüfbericht-Nr.: / Test Report No.: Test Report – Products 60440951-001 Seite 3 von 20 Page 3 of 20 TÜV Rheinland Sweden AB. Mobilvägen 10, 223 62 Lund, Sweden Phone.: +46 46 272 57 46 Mail: [email protected] Web: www.tuv.com Table of Contents 1. GENERAL INFORMATION ................................................................................................................................... 4 1.1 Test Site ............................................................................................................................................................................................ 4 1.2 Client Information .............................................................................................................................................................................. 4 2. PRODUCT INFORMATION................................................................................................................................... 5 2.1 General Description........................................................................................................................................................................... 5 2.2 Device Characteristics ....................................................................................................................................................................... 5 2.3 Test Samples .................................................................................................................................................................................... 5 2.4 Wireless Technologies and Bands Supported by the EUT ................................................................................................................. 6 2.5 Antenna Information .......................................................................................................................................................................... 6 2.6 Simultaneous Transmission Capabilities ........................................................................................................................................... 6 2.7 Wireless Technology Details ............................................................................................................................................................. 7 2.8 Ancillary Equipment........................................................................................................................................................................... 7 2.9 EUT Diagrams................................................................................................................................................................................... 7 3. TEST METHODS ..................................................…
Text truncated - open the document above for the full version.
Prüfbericht - Produkte Test Report – Products Prüfbericht-Nr.: Test report no.: 60440947-001 Appendix 1 Auftrags-Nr.: Order no.: 23870482 030 Seite 1 von 13 Page 1 of 13 Kunden-Referenz-Nr.: Client reference no.: 2311184 Auftragsdatum: Order date: 2020.12.09 Auftraggeber: Client: Wittra Sweden AB Prüfgegenstand: Test item: Gateway 1.0 US Bezeichnung / Typ-Nr.: Identification / Type no.: Gateway 1.0 / FCC ID:2AYHX00347 Auftrags-Inhalt: Order content: Accredited testing according to FCC Part 15C Prüfgrundlage: Test specification: FCC 47 CFR Part 15.247 with parts 15.207 & 15.209 ANSI C63.10: 2013 Wareneingangsdatum: Date of sample receipt: 2020.12.09 Prüfmuster-Nr.: Test sample no: See section 2.3 Prüfzeitraum: Testing period: 2021.01.22 – 2021.04.14 Ort der Prüfung: Place of testing: Lund, Sweden Prüflaboratorium: Testing laboratory: TÜV Rheinland Sweden Prüfergebnis*: Test result*: Pass überprüft von: reviewed by: X Signed by: Niall Forrester genehmigt von: authorized by: X Signed by: Per Isacsson Datum: 2021.05.12 Date: Datum: 2021.05.12 Date: Stellung / Position: Senior Technical Expert Stellung / Position: Lab Manager Sonstiges / Other: Note: This report contains information for IEEE 802.15.4 measurements only. Zustand des Prüfgegenstandes bei Anlieferung: Condition of the test item at delivery: Prüfmuster vollständig und unbeschädigt Test item complete and undamaged * Legende: 1 = sehr gut 2 = gut 3 = befriedigend 4 = ausreichend 5 = mangelhaft P(ass) = entspricht o.g. Prüfgrundlage(n) F(ail) = entspricht nicht o.g. Prüfgrundlage(n) N/A = nicht anwendbar N/T = nicht getestet * Legend: 1 = very good 2 = good 3 = satisfactory 4 = sufficient 5 = poor P(ass) = passed a.m. test specification(s) F(ail) = failed a.m. test specification(s) N/A = not applicable N/T = not tested Dieser Prüfbericht bezieht sich nur auf das o.g. Prüfmuster und darf ohne Genehmigung der Prüfstelle nicht auszugsweise vervielfältigt werden. Dieser Bericht berechtigt nicht zur Verwendung eines Prüfzeichens. This test report only relates to the a. m. test sample. Without permission of the test center this test report is not permitted to be duplicated in extracts. TÜV Rheinland Sweden AB. Mobilvägen 10, 223 62 Lund, Sweden Phone.: +46 46 272 57 46 Mail: [email protected] Web: www.tuv.com Prüfbericht – Produkte Prüfbericht-Nr.: / Test Report No.: Test Report – Products 60440947-001 Appendix 1 …
Text truncated - open the document above for the full version.
Vastra Jarnvagsgatan 3 · Stockholm · Sweden
| # | Rule Parts | Frequency Range | Power Output |
|---|---|---|---|
| 1 | 15C | 902.2 MHz - 927.8 MHz | 8.50 mW |
Wireless Asset Tag
Equipment Class
DTS - Digital Transmission System